| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 2 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 3 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-inCharge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 4 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 5 | Extra for filling ofCement mortar 1:4 (1 cement : 4 coarse sand). |
| 6 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge |
| 7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 8 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 9 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 10 | Providing and fixing of 2mm thick PVC flexible European make homogeneous compacted anti-static floor covering of size 2mtrs x 20 mtrs. having total weight 3250 g/m2. It should feature a stylish non-directional design, with a duotone decoration with marbleised tonal highlight chips, incorporated with specially formulated PUR features a high quality, crosslinked polyurethane reinforcement, UV cured to provide a low cost, polish-free maintenance regime for the lifetime of the flooring and its surface should densely compacted for improving wear and ease of maintenance. It should have Type 1 abrasion resistance as per EN ISO 10581 and complies with the EN 685 (34-43), making it suitable for very heavy commercial and heavy- light industrial use. It should also confirm to class Bfl-s1 in flammability test as per EN13501-1. It should have slip resistance of R9 as per EN 13893 Class DS and very low VOC emission. It should pass all the most stringent international VOC emissions tests, including Ag-BB, Floor Score and Indoor Air Comfort Gold from Euro fins. It should demonstrate from independent tests that it inhibits the growth of MRSA on the floor to prevent any kind of infection. It should also achieve a BRE Global Environmental A + Rating and a Green Tag LCA Rate certified with Green Rate level A- Gold Plus. From independently assessed by the BBA (British Board of Agreement), it should be awarded a 10- year product performance assurance in the recommended use areas. The floor finish should terminate at the room perimeter passing over a concealed cove former and continuing up the wall for 100mm. The joints in the flooring should be sealed by using a PVC welding bar of matching colour to be supplied by the manufacturer, using a hot air gun for fusion of welding bar with flooring. The vinyl sheet shall be laid & fixed with water-based adhesive as per manufacturer’s specification and the entire satisfaction of Engineer-in-charge complete. |
| 11 | Supply & Fixing Of MYK Arment Soloplan 25M Self Leveling. The surface to be leveled mustcomply with the principles of building construction and should fulfill the structural requirements. Any crack, pot holes joints etc should be properly sealed and cured. The surface to be treated should be free from all coatings dust and unsound concrete toppings and surface homogeneous mix, the properly mixed compound should be poured on to the surface and leveled by using of squeegees or broad brushes For layers less than or the same as2-3 mm thick, concrete and cement screeds are to be primed with FloArm Uniprime GE / FloArm Uniprimer K, FloArm Soloplan-25 is applied as soon as the primer has dried. contractor to allow the primer coat to completely dry out (approx. 6- 12 hours) as the absorption capacity of the surface is minimized and the flow behavior of FloArm Soloplan-25is maintained. |