| Sl. No. | Item Description |
| 1 | M&L for preparation of old decorated surfaces of walls and applying one coat of oil emulsiondistempercomplete all as specified and directed all as specified. |
| 2 | M&L for preparation of old decoratedsurfaces of ceiling and applying one coat of oil emulsion distempercomplete all as specified and directed all as specified and directed. |
| 3 | M&L for preperation of old painted external surface of wall, facia etc and applying one coat of 100% acrylic exterior weather proof emulsion paint of requied shade with anti-algae and anti-fungal properties including, scaffolding, curing and saftey arrangments, etc. complete all as specified and directed as per manufacturer’s specification and direction of engineer in Charge. |
| 4 | M&L for preperation of old painted external surface of ceilingand applying one coat of 100% acrylic exterior weatherproof emulsion paint of requied shade with anti-algae and anti-fungal properties, over one coat of primer, includingscaffolding, curing, and safety arrangement etc. complete all as specified and directed as per manufacturer’s specification and direction of Engineer in Charge. |
| 5 | M&L for preperation of old painted external surface of wall, facia etc and applying two coat of 100% acrylic exterior weather proof emulsion paint of requied shade with anti-algae and anti-fungal properties including, scaffolding, curing and saftey arrangments, etc. complete all as specified and directed as per manufacturer’s specification and direction of engineer in Charge. |
| 6 | M&L for preparation of oldwooden surface of any description and applying one or more coat french polish till achiving desired finishall as specified and directed. |
| 7 | M&L for preparation of old painted steel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint with necessory scafolding and sfety measures etc , complete all as specified and directed all as specified and directed. |
| 8 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coatof synthetic enamel paint, complete all as specified and directed all as specified and directed. |
| 9 | M & L for washing, rubbing down and stopping of distempered and painted old plastered surfaces of wallsand apply two coats ofdistemper oil emulsion over a coat of alkali resistantprimer over a coat 2 mm thick wall care putty, complete all as specified and directed all as specified. |
| 10 | M&L for complete all as specified and directed removal of existing treatment on ceiling surfaces and applying two coats of oil emelsion distemper over a coat of alkali resistantprimer over t 2 mm thick wall care putty complete all as specified and directed all as specified and directed. |
| 11 | M&L for preperation of old painted external surface of wall, facia etcand applying two coats of 100% acrylic exterior weatherproof emulsion paintwith anti-algae and anti-fungal properties, over one coat of primer, includingscaffolding, curing, and safety arrangement etc. complete all as specified and directed as per manufacturer’s specification and direction of Engineer in Charge. |
| 12 | M&L for cleaning of PCC paver block, chequred tiles and any type of PCC flooring by water spray and apply Two coat of acrylic emulsion paint suitable for floor by using brush, complete all as specified and directed all as specified. |
| 13 | M&L for Cutting out & removal of plants, roots, shurbs etc from the roof, brick/stone wall built in cement mortar & applying chemical GLYPHOSATE 41% SL (Soluble Liquid) mixed with water in the proportion of 1: 75, at the place to avoid re-growing of plants/roots & making good the disturbed portion of roof, wall with brick works in CM 1:3 at wall portion & PCC 1:2:4 at roof slab & matching the surface to existing finish ie any type of paintover 15mm thick rendering inCM 1:4 including disposal of demolished material/ waste out of M D land of high rise bldgs/walls complete all as specified and directed all as specified and directed.. |
| 14 | M&L for gentaly cleaning the surface of the stone masonary/ stone chips and piers with specialized eater misting techniques employing air water jet using a fine nozzle sprinkling system calibrated to spray a fine mist along the stone surface without over wetting followed up by gentle brushing with soft nylon brushes as specified and milded. Gentle surface cleaning may include using water misting and PH balanced surfactants as specified for indicated areas to remove surface dirt grit surface accretions, lime wash painting etc, fininshes similar type as the adjcent wall surface complete all as specified and directed all as specified and as directed Note : Quoted rate shall be inclusive of removing vegetation on wall surfaces. |
| 15 | Taking down chowkats or frameswith shutters (without taking off shutters from the frame) n exc 1.5 sqm each complete all as specified and directed all as specified and directed. |
| 16 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each but n.exc 4 sqm each complete all as specified and directed all as specified and directed. |
| 17 | Taking down shutters of any description not exceeding1 sqmeach,complete all as specified and directed all as specified and directed. |
| 18 | Taking down shutters of any description exceeding1 sqm and notexceeding2 sqm each,complete all as specified and directed all as specified and directed. |
| 19 | M&L for 2nd class HW (SAL) Plain, solid, straightchowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints,complete all as specified and directed all as specified and directed. |
| 20 | S&F 35 mm thick factory made 2nd class Hard wood rail & stile plain framed , panelled shutter ( two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed all as specified and directed.. |
| 21 | S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed all as specified and directed. |
| 22 | S&F 30 mm thick 2nd class hardwood glazed and skeleton shuttersopen rebated and prepared to receive glass, gauze, etc. divided in to squares,with plain, chamfered or rounded , mitred and rebatedsash bars,any numbers ; edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified ; supplied and fitted to chowkhats , complete all as specified and directed all as specified and directed. |
| 23 | S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings. |
| 24 | S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading andjointed together with solvent cement supply & fixing in the frame at site. complete all as specified and directed all as specified. |
| 25 | S & F Powder coated aluminium sections (minimum thickness of powder coating 50 micron) for shutters and frame of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required complete all as specified and directed all as specified.Note :-(i)Glass panes shall be measured and paid seperately. (ii) The rate quated shall be inclusive of neoprene beading, glazing clips, screws etc as required but shall not be measured for arriving weight.(iii) The rate shall be inclusive of locking arrangement including complete all as specified and directed packing with silicon gel around contacting surface of aluminium work with matching existing areas. (iv) The size of aluminum section shall be as per HQ CETD drawig No TD/2021/01 to 05 . |
| 26 | S&Fin repairs aluminium grill with and including suitable aluminiumanodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick including all necessory fittings fixed with SS screws all as specified and as directed. |
| 27 | S & F sheet glass4.mm thick ordinary quality arean exceeding 0.5 Sqm in each pane, complete all as specified and directed all as specified. |
| 28 | S & F sheet glass4.mm thick ordinary quality area exceeding 0.5 Sqm in each pane, complete all as specified and directed all as specified. |
| 29 | S&F 3mm thick sheet glass froasted or obscured one side and glazing with oil putty or wooden beads in square area n.exc 0.5 Sqm in each pane complete all as specified and directed.all as specified and directed. |
| 30 | S&F Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed all as specified and directed. |
| 31 | S&F in repair Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed all as specified and directed. |
| 32 | S&F 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts ISI marked complete all as specified and directedall as specified. |
| 33 | S&Fin repair300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts ISI marked complete all as specified and directedall as specified. |
| 34 | S&Fin repair aluminiumanodized barrel tower bolts 200 mm of extruded sectionISI markedcomplete all as specified and directedall as specified. . |
| 35 | S&Faluminiumanodized barrel tower bolts 200 mm of extruded sectionISI markedcomplete all as specified and directedall as specified. . |
| 36 | S&F in repair aluminiumanodized barrel tower bolts 150 mm of extruded sectionISI markedcomplete all as specified and directedall as specified. . |
| 37 | S&F aluminiumanodized barrel tower bolts 150 mm of extruded sectionISI markedcomplete all as specified and directedall as specified. . |
| 38 | S&F aluminium alloy handles, 150 mm sizecast type anodised, ISI markedcomplete all as specified and directedall as specified. . |
| 39 | S&Fin repairaluminium alloy handles, 150 mm sizecast type anodised, ISI markedcomplete all as specified and directedall as specified. . |
| 40 | S&F stainless steel butt hinges 100 mm size, medium weight with SS hinge pin, bright finishedcomplete all as specified and directedall as specified. |
| 41 | S&Fin repairstainless steel butt hinges 100 mm size, medium weight with SS hinge pin, bright finishedcomplete all as specified and directedall as specified. |
| 42 | S&F stainless steel butt hinges 75 mm size, medium weight with SS hinge pin, bright finishedcomplete all as specified and directedall as specified. |
| 43 | S&Fin repairstainless steel butt hinges 75 mm size, medium weight with SS hinge pin, bright finishedcomplete all as specified and directedall as specified. |
| 44 | M & L for Mild steelflat 25 X 5 mm for hold fast. Conforming to Fe-290-0 or Fe-165 complete all as specified and directed. |
| 45 | M& L for cement concrete !;3:6 type C-1 , 20 mm graded stone aggregateas in filling concrete completeall as specified and directed. |
| 46 | S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring ISI marked all as specified |
| 47 | S&F in repair 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring ISI marked all as specified |
| 48 | S&F in repairs doorcloser aluminium (Die cast) body hydraulically regulated, designation No 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed complete all as specified and directed all as specified and directed. |
| 49 | S&F in repairs mild steel, 300 mm long ordinary helical door spring incl roller and roller plate complete all as specified and directed aal as specified and directed.. |
| 50 | S&F in repair 25mm Harrison rails, mild steel, chromium plated includingbrackets at both ends , stops, rollers etc. type designe and pattern as approved ,complete all as specified and directed all as specified . |
| 51 | Resecuring or easing & adjusting without taking down shutters of any description n.exc 1 Sqm each , complete all as specified and directed all as specified and directed. |
| 52 | Resecuring or easing & adjusting without taking down shutters of any description exc 1 Sqm but n.exc 2 Sqm each , complete all as specified and directed all as specified and directed. |
| 53 | S & F in repair Roller venetion blinds made out of standard cloth of approved texture with necessary accessories and fixing in positioncomplete all as specified and directed |
| 54 | S&Ftoughened glass 12mm thick, for door shutters, partitions, shelves etc with including fitting and fixtures such as glass handles, ss studs, stand, fittings for door pivots etc complete all as specified and directed. |
| 55 | S & F in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed. |
| 56 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc)/slabs/blankets any thickness including cover fillets etc complete all as specified anddirected. |
| 57 | S&F Anodised aluminium snap grid size 605x605mm frame work for false ceiling complete all as specified and directed. |
| 58 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats complete all as specified and directed. |
| 59 | M&L for false ceiling made out of 600x600x 4 mmthick( non asbestos fiber cement designer/coloured) ceiliing board / tiles deep panel as per approved colour and pattern and fixed position all as specified and directed. |
| 60 | M&L for POP false ceiling using 600X900x12mm thick plaster of paris with gypsum binder sheet decorative type including two coats of plastic emulsion paint and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre, secondary joist of size 75X20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2 M C/C, complete all as specified and directed. |
| 61 | Dismantling ofwall panelling and similar work any typeand pttern complete all as specified |
| 62 | S&F 3mm thick aluminium composite plain panel of approved colour and pattern for cladding , beam/column/slab incircular/ rectangular shape inbcluding cutting, notching, bending to shape as required jointing with silicon gel of approved colour including aluminum tubular hallow section 25 x 25 mm not exceeding 900 mm C/Ccomplete all as specified and directed. |
| 63 | S & F4mm thick bakelite sheet with decorative choice laminated on both side complete all as specified and as directed. |
| 64 | S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall vertically with screws andC/C deistane 30 CMto make PVC frameall as specified and directed. |
| 65 | S & F PVC wall /ceiling panelconsist of 5mm thick plain approved colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame all as specified and directed . |
| 66 | S&F 9 mm thick prelaminated medium density particleboard, interior grade, prelaminated both side with decorative choice laminationfixed with S S screws to aluminium frame work complete all as specified and directed. |
| 67 | S&F 12 mm thick prelaminated medium density particleboard, interior grade, prelaminated both side with decorative choice laminationfixed with S S screws to aluminium frame work complete all as specified and directed. |
| 68 | M&Lfor 12 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work, cabinet ,cup boards, drawers, partitionscomplete all as specified and directed. |
| 69 | M&L for 0.9 mm thick decorative texture finish laminate type 1, of surface finishof approvedcolour and patternfixed with adhesive as per manufacture\"s instruction complete all as specified and as directed. |
| 70 | M&L for 12mm thick marine ply wood suitable for modular kitchen cupboards, drawers, partitions etc fixing to frame complete all as specified and directed. |
| 71 | M&L for 18 mm thick marine ply wood suitable for cupboards, drawers, partition etc offixing to frame complete all as specified and directed. |
| 72 | S&F in repairs Wall paper of fibrious material, nonwoven Vinyl free, making them fixed to wall with dry strips or with approved adhesive. |
| 73 | S&F 2 mm thickLinoleum, plain coloured laid in floors incliding streching, cutting, fitting incl seales down with an approved adhesivecompleteall as specified and directed. |
| 74 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, upto 7th floor of bldg.,complete all as specified and directed all as specified and directed. |
| 75 | Demolition of brick work or stone masonary built in cement mortarincluding all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles including removing debris out side MD land all as specified and directed. |
| 76 | Material andlabour for brick work with sub class \"B\" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed. |
| 77 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick wallsbuilt in CM (1:4), complete all as specified and directed all as specified and directed. |
| 78 | M&L for rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces in patches, surfaces to be finished even and smooth without using extra cement, complete all as specified and directed all as specifiedand directed. |
| 79 | M&L forrendering 05 mm thick in CM 1:3 in ceiling finishing even and smooth without using extra cement, complete all as specified and directed all as specified and directed. |
| 80 | M&L for rendering 20 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fairincluding mixing integral water proofing compound in the proportion as mentioned in manufacturer\"s instructions &complete all as specified and directed . |
| 81 | M&L for applying 4mm thick finished texture mortar in CM 1:2 (Mix one part of white cement & two parts of Dholpuri clear quarts powder of 1 to 2 mm grading) includingtexture finish shall be achieved with the help of hand driven machine ,preparation of oldtreated surface / newly plastered surfaces and making plain surface of stone masonary pattern incld irrection & dismantling of scaffolding to carrying out works complete all as per manufactures instructions complete all as specified and directed. |
| 82 | Supply only integral water proofing compound complete all as specified and directed all as specified and directed. |
| 83 | M&L for applying 1 to 2 mm thick wall care putty for making the surface even & smooth complete all as specified and directed . |
| 84 | M&L for preparation of newlyplastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed. |
| 85 | M&L for preparation of newlyplastered surfaces of ceiling and applying threecoats of white wash on ceilingcomplete all as specified and directed all as specified and directed. |
| 86 | M&l for preperation of newly plastered external surface of wallsand applying two coats of 100% acrylic exterior weatherproof emulsion paint of approved make, with anti-algae and anti-fungal properties, over one coat of alkali resistant primer, includig scaffolding, curing saftey measures, etc. complete all as specified and directed. |
| 87 | M&L for preparation ofsteel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint with necessory scafolding and sfety measures etc , complete all as specified and directed all as specified and directed. |
| 88 | M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coastof synthetic enamel paintover a coat of pink primer , complete all as specified and directed. |
| 89 | Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) including removing debris out side MD land complete all as specified and directed all as specified and directed. |
| 90 | M&L for 75 mm thick cement concrete type C2 1:3:6,40mm graded stone aggregateas in sub base including laying and levellingcomplete all as specified and directed. |
| 91 | Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, including removing debris out side MD land complete all as specified and directed. |
| 92 | Dismantling floor, hearth or wall tiling (fixed at any portion but not backing) including cement mortar bedding and removingrubbish off the premises (outside MD land) complete all as specified and directed. |
| 93 | M&L for coloured non-skid ceramic tiles of approved make 7-8mm thick rectified glossy (square/rectangular) areaof each tiles exceeding 0.06 Sqmbut not exceeding 0.11Sqm in floors , set and jointed in neat cement slurry and pointed in whiteor coloured cement to match incl 15mm thick screed bed (1:6),complete all as specified and directedall as specified and directed. |
| 94 | M&L for coloured non-skid ceramic tiles of approved make 7-8mm thick rectified glossy (square/rectangular) areaof each tiles exceeding 0.11 Sqmbut not exceeding 0.18 Sqm in floors , set and jointed in neat cement slurry and pointed in whiteor coloured cement to match incl 15mm thick screed bed (1:6),complete all as specified and directed . |
| 95 | M&L for Glazed ceramic tiles of approved make coloured of size 450X 300X 7 mm on vertical surface such as dado/skirting over and including cement mortar backing coat,10 mm thick in CM 1:4 set jointed in neat cement slurry and pointed in white or colouredcement complete all as specified and directed . |
| 96 | M&L light shade double chargedvirified tiles of approved make 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchin floor including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 97 | M&L Virified tiles dark shade 10 mm thick of approved make (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchin floor including15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4set and jointed in neat cement slurry and pointed in white or coloured cement to match.complete all as specified and directed. |
| 98 | M&L light shadedouble chargedvitrified ceramic tiles of approved make 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36sqm (600x600mm), but as on vertical surfaces such as skirting/dado including 10mm thick rendering in CM 1:3 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match .complete all as specified and directed. |
| 99 | M&L for 18 - 20mm thick machine cut mirror polishedGranite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table, floors and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granite incl moulding and rounding allall as specifiedand directed. |
| 100 | M&L, for mirror polished machine cut kota stone slab flooring 20 to 25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing as specified in SSR Part I complete all as specified and directed |
| 101 | M&L, for machine cut kota stone slab 22-25mm thickin riser / treads of steps in single piece, skirting, dado and pillar laid over cement screedbed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed |
| 102 | M&L for 18 to 20mm thick machine cut mirror polished green marble (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like incl 15mm screeed in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade. |
| 103 | M & L Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed. |
| 104 | M&L for Grinding and polishing existing floor of any type (kota stone/mossaic/cuddpah stone floor) as specified in SSR Part I complete all as specified and directed all as specified and directed. |
| 105 | M&L for Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade confirming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved colour, laid in required colour and patteren over and including 30 mm thick copacted bed of course sand, filling the joiints with fine sand etc. all as specified and directed. |
| 106 | M&L for moulded Chequered cement concrete tiles 30cm x 30cm x 22-25 mm thick with grey cement & pigments, set, jointed and pointed in neat cement slurry in floors over screed bedor bedding layer of mortar in CM (1:4) 20mm thickincluding dismantling of old tiles, complete all as specified and directed all as specified. |
| 107 | M&L for roughening surfaces of old concrete surfaces by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and directed. |
| 108 | M&L for roughening surfaces of old concrete surfaces by picking, sweeping cleaning and washing down with water to remove dust etc including taking down tarfelt and 15 mm thick screeding in cement mortar 1:4 finished even and smooth without using extra cement including mixed with water proofing compound as per manufacturer instructions (WPC shall be measured and paid separately)complete all as specified and directed. |
| 109 | M&L PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) cement concrete as a leveling courseon roof surfaces and coping complete all as specified and directed.. |
| 110 | M&L for laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not F92 less than 150 gms/sqm) land on a coat of bituminous primer 0.25 Kg/Sqm on prepared surface of plaster as per manufacturer\"s instructions, manufactured by the same agency of APP membrane. The APP membrane shall be laid using torch on application with minimum 100 mm side overlap and 150 mm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. The APP membrane shall be taken upto minimum 200 mm on vertial surfaces. The edge of the membrane shall besealed with sealant complete all as specsified and directed. |
| 111 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, unctions of pipes and masonry with polymer mixed slurry. |
| 112 | M&L for preparation of old concrete surfaces and applying one coat of bitumen primer (Black magic/equivalent) @1 ltr/sqm suitable for arresting leakage/seepage of rainwater, applying with spray or brush and ensure all the cracks should be sealed properly as per manlufacturer\"s instruction etc all as specified and directed. Note : Payment will be made only after testing and executed satisfactorily as per Engr-in-chargecomplete all as specsified and directed. |
| 113 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all specified and directed. |
| 114 | M&L for Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks,gate, hook and pidle hinges,large hasp and staples, clamps , heavy sliding bolt, clamp ties, straps, plate washersand similar work conforming to Fe 290 Gd E-165 all as specified and directed. |
| 115 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable fixing arrangement.complete all as specified and direted. |
| 116 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 117 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and directed all as specified and as directed. |
| 118 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres complete all as specified and directed all as specified and as directed. |
| 119 | Taking down15 mm old steel tubing and connections(Walls, ceiling,floors, etc.), complete all as specified and directed all as specified. |
| 120 | Taking down20 mm old steel tubing and connections(Walls, ceiling,floors, etc.), complete all as specified and directed all as specified. |
| 121 | S&F 15 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittingsconcealed or open on walls/ceiling or laying in floors including fixing of pipes in wall with clampscomplete all as specified and directed all as specified. |
| 122 | S&F 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittingsconcealed or open on walls/ceiling or laying in floors including fixing of pipes in wall with clampscomplete all as specified and directed all as specified. |
| 123 | S&F in repairsvitreous china wash down water closet coloured(pedestal pattern) including plastic seat cover with nuts and bolts etc complete all as specified and directed all as specified and directed. |
| 124 | S&F in repairs water closet squattus pan (Orissa pattern) 580x440mm, white with integral foot rests including connecting to trap and to flushing pipe antisyphonage pipe including \"P\" or \"S\" trapand providing of lime concrete beddingand making good to floor (excluding flushing cistern and flush pipe) complete all as specified and directed all as specified and directed.. |
| 125 | supply onlyPVC (SWR) floor trap 100 mm,includingjointing to connectionpipe fixed in cement concrete 1:2:4 complete all as specified and directed all as specified and directed. |
| 126 | S&F in repair 10 ltr capacity PVC syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connetion to pipe but fixed in repair complete all as specified and directed all as specified. |
| 127 | S&F in repairs, Plastic water closet seat cover coloured, fixing to water closet pedestal pattern including fixtures complete all as specified and directed . |
| 128 | S&F in repairs 32 mm PVC Flush pipe for low and High level flushing cistern and fixed in position and making wall/ floor surface as existing complete all as specified and directed. |
| 129 | S&F in repairs vitreous china wash hand basinflat back of size 550x400mm including bracket, brass chromium plated waste coupling of 32 mm boreand CP pillar tap 15mm borefancy type complete all as specified and directed all as specified and directed. |
| 130 | S&F in repair counter type wash hand basin (oval shape) vitreous china white including32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long ,barss chromium plated pillar tap of 15 mm bore of suitable design etc complete all as specified and directed. |
| 131 | S&F in repair vitreous china urinal, halfstall type white (excluding flushing cistern, flush pipe )but including PVC waste pipe , providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement andfixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern trap and waste pipe)complete all as specified and directed. |
| 132 | S&F in repairs CP stop cock/ angular stop cock 15 mm bore complete all as specified and directed all as specified and directed. |
| 133 | S&F in repairs15mm boreBib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed . |
| 134 | S&F in repairs15mm bore 2 in 1 Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified and directed. |
| 135 | S&F in repairs15mm bore push cockcast copper alloy chromium plated chromium plated, for urinal fised to pipecomplete all as specified and directed. |
| 136 | M&L for urinal spreader15 mm boreCP for fixed to PVC connectioncomplete all as specified and directed. |
| 137 | S&F in repairsfancy type Pillar taps 15mm borecast copper alloy chromium plated withcapstain head scewed down high pressure with long screwed shank and fly nutscrewed for pipe complete all as specified and directed., |
| 138 | S&F in repair Brass chromium plated shower rose 125 mm size with or without swivel joints, including fixing to steel pipe or unionfixed complete all as specified and directed. |
| 139 | S&F in repairs health faucet ABS Body with 15 mm bore 1 mtr flexible tube and wall hook complete all as specified and directed all as specified anddirected. |
| 140 | S&FPVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed all as specified and directed. |
| 141 | S&FPVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed all as specified and directed. |
| 142 | S&F in repairsstain less steel Toilet paper holder of approved quality with flat recessed type ixed with suitable SS screw Complete all as specified and directed. |
| 143 | S&F in repairs32/38 mm bore flexible PVC waste pipe suitable for WHB/urinal /Sink complete all as specified and directed all as specified and directed. |
| 144 | S&F in repairsstain less soap dishholder of approved qualityfixed with suitable SS screwComplete all as specified and directed. |
| 145 | S&F in repairs coner glass shelf of approved quality includingbracket fixed with suitable SS screw complete all as specified and directed. |
| 146 | S&F first quality looking mirror of approved size andquality including teak wood beeding all around complete all as specified and directed. |
| 147 | S&Fin repairs600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed with SS screws and cup washers complete all as specified and directed. |
| 148 | S&F in repairs CP towel rail 600 mm long withround flange fixed with SS screws complete all as specified and as directed |
| 149 | S&F 300 litre capacity rotational moulded polyethylene water storage loft tankshoisted and fixed in position all specified in SSR Part-I, with and includingBall brass valve 20mm bore , high pressure, with polythene float and flynut complete all as specified and directed, screwed for iron pipe or brass ferrule and fixed, screwed for iron/PVC pipes including disconnecting and dismantling/ taking down of existing old unserviceable water storage tankcomplete all as specified and directed . |
| 150 | S&F 500 litre capacity rotational moulded polyethylene water storagetankshoisted and fixed in position all specified in SSR Part-I, with and includingBall brass valve20 mm bore, high pressure, with polythene float and flynut complete all as specified and directed, screwed for iron pipe or brass ferrule and fixed, screwed for iron/PVC pipes including disconnecting and dismantling/ taking down of existing old unserviceable water storage tankcomplete all as specified and directed . |
| 151 | S&F 1000 litre capacity rotational moulded polyethylene water storage tankshoisted and fixed in position all specified in SSR Part-I, with and includingBall brass valve20 mm bore, high pressure, with polythene float and flynut complete all as specified and directed, screwed for iron pipe or brass ferrule and fixed, screwed for iron/PVC pipes including disconnecting and dismantling/ taking down of existing old unserviceable water storage tankcomplete all as specified and directed . |
| 152 | S&F in repairs 15 mm borePTMT Ballvalves, high pressure, with polythene float and flynut complete all as specified and directed, screwed for iron pipe or brass ferrule and fixed |
| 153 | S&F in repairs 20 mm borePTMT Ballvalves, high pressure, with polythene float and flynut complete all as specified and directed, screwed for iron pipe or brass ferrule and fixed |
| 154 | S&F in repairs SS grating 100 mm dia ,fixed with white cement to sides ,complete all as specified and directed |
| 155 | Taking down CI/PVC/ACpipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 100 mmbore pipe complete all as specified and directed. |
| 156 | Taking down CI/PVC/ACpipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 75/80 mmbore pipe complete all as specified and directed. |
| 157 | S &F 110 mm bore PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall with dash throgh fastners and rain water bracket suitable for 160 mm bore pipe spacing 1.5 m c/c as per CE (Navy) mumbai drg No TD/2023/01 or laid in floor complete all as specified and directed all as specified and directed. complete all as specified and directed including ss clamping , scafolding etc all as specified and directed. |
| 158 | S &F 75 mm bore PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall with dash throgh fastners and rain water bracket suitable for 160 mm bore pipe spacing 1.5 m c/c as per CE (Navy) mumbai drg No TD/2023/01 or laid in floor complete all as specified and directed all as specified and directed. complete all as specified and directed including ss clamping , scafolding etc all as specified and directed. |
| 159 | S&FPVC (SWR) bendsany radious 110 mm bore fixed with rubber ring joints complete all as specified and directed all as specified and as directed |
| 160 | S&FPVC (SWR) bends any radious75 mm bore fixed with rubber ring joints complete all as specified and directed all as specified and as directed |
| 161 | S&FPVC (SWR) bends any radious with access door110 mm bore fixed with rubber ring joints complete all as specified and directed all as specified and as directed |
| 162 | S&FPVC (SWR) bends any radius 75 mm bore fixed with rubber ring joints complete all as specified and directed all as specified and as directed |
| 163 | S&F in repairs PVC (SWR) floor trap 75 mm, with grating includingjointing to connectionpipe fixed in cement concrete 1:2:4 complete all as specified and directed all as specified and directed. |
| 164 | Taking down CI/PVC/ACpipes (including all fittings), with spigot and socket ends and lead joints including burning out joints of 150/160 mmbore pipe complete all as specified and directed. |
| 165 | S &F 160 mm bore PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to wall with dash throgh fastners and rain water bracket suitable for 160 mm bore pipe spacing 1.5 m c/c as per CE (Navy) mumbai drg No TD/2023/01 or laid in floor complete all as specified and directed all as specified and directed. complete all as specified and directed including ss clamping , scafolding etc all as specified and directed. |
| 166 | S&FPVC (SWR) bends any radius 160mm bore fixed with rubber ring joints complete all as specified and directed all as specified and as directed |
| 167 | S&F in repair stainless steel sink with drainage board made out of stainless steel1mm thick sheet for kitchen with plug, washers and waste pipe incl bedding in cement mortar to dward wall or incl fixing cantilever brackets and connecting union to pipeoverall size 915 x 460mm and bowl size 410 x 330 x 160mmcomplete all as specified and directed. |
| 168 | Demolition of Cement concrete in ground floor and pavings (below or above ground level) and removal of debris to out side MD land complete all as specified and directed all as specified and directed. |
| 169 | M&L for 75 mm thick cement concrete type C2 1:3:6,40 mm graded stone aggregateas in flooring finished the surface fair andsmooth with out using extra cement complete all as specified and directed. |
| 170 | S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS -1161 1979 grade St-240 |
| 171 | M&L forcement concrete type B-2 , 1:2:4 (40 mm graded stone agg) as in mass concrete finishedsurface even and smooth by with out using extra cement complete all as specified and directed. |
| 172 | M & L forframed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as pecified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail