| 1 | 1) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | a) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | b) 1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 2) Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. |
| 5 | a) Cement mortar 1:4 (1 cement :4 coarse sand) |
| 6 | 3) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 7 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | 4) Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 9 | a) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 10 | 5) Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 11 | a) 250x16 mm |
| 12 | 6) Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 13 | a) 200x10 mm |
| 14 | 7) Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 15 | a) 100 mm |
| 16 | 8) Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge.Extruded section profile size 42x50 mm. |
| 17 | 9) Providing and fixing to door frames. |
| 18 | 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 19 | 10) Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. |
| 20 | Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 21 | Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 22 | Two track two panels sliding window made of (small series) frame 52 x 44 mm &s ash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 23 | 11) Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 24 | 12) Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 25 | 13) Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 26 | (i) Single socketed pipes. 110 mm diameter |
| 27 | 14) Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 28 | a) Coupler |
| 29 | i) 110mm |
| 30 | b) Single tee with door |
| 31 | i) 110x110x110 mm |
| 32 | c) Bend 87.5° |
| 33 | i) 110 mm bend |
| 34 | d) Shoe (Plain) |
| 35 | i) 110 mm Shoe |
| 36 | 15) Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 37 | 16) Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 38 | 17) Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 39 | a) Old work ( Two or more Coat applied @1.67 ltr/ 10 sqm) on existing cement paint surface |
| 40 | 18) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 41 | a) One or more coats on old work. |
| 42 | 19) Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 43 | a) With cement mortar 1:4 (1 cement : 4 fine sand). |
| 44 | 20) Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 45 | a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 46 | 21) Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. |
| 47 | 22) Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 48 | a) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 49 | 23) Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 50 | a) W.C. pan with ISI marked white solid plastic seat and lid |
| 51 | 24) Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 52 | 25) Renewal of old putty of glass panes (length) . |
| 53 | 26) Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 54 | a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 55 | b) Nominal concrete 1:4:8 or leneior mix |
| 56 | 27) Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 57 | a) In cement mortar |
| 58 | 28) Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 59 | a) Of area 3 sq. metres and below |
| 60 | 29) Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 61 | a) For thickness of tiles 10 mm to 25 mm |
| 62 | 30) Dismantling C.I. or asbestos or PVC rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 63 | a) 75 to 80 mm dia pipe. |
| 64 | b) 100 mm dia pipe |
| 65 | 31) Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 66 | a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 67 | 32) Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 68 | a) Rectangular shape 453x357 mm |
| 69 | 33) Providing and fixing sanitary fittings/appliances by removing the existing damaged sanitary and water supply fittings and replacing them with these new fittings including necessary white lead/ lead wool etc complete as directed by the engineer in charge. |
| 70 | a)P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe.32 mm dia |
| 71 | b)PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms. |
| 72 | c) PTMT Bib cock15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. of approved quality and colour. |
| 73 | d) PTMT stop cock15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. of approved quality and colour. |
| 74 | e) PTMT grating 100 mm nominal dia.Circular type, of approved quality and colour. |
| 75 | f) Uplasticised PVC connection pipe 15 mm nominal boreand 45 cm length with brass unions : |
| 76 | 34) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 77 | a) 20 mm nominal outer dia. Pipes. |
| 78 | b) 25 mm nominal outer dia .Pipes. |
| 79 | c) 40 mm nominal outer dia .Pipes. |
| 80 | 35) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work |
| 81 | a) 40 mm nominal outer dia. Pipes. |
| 82 | 36) Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 83 | a) 25 to 40 mm nominal bore |
| 84 | 37) Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight RCC precast. cover with frame of 300 x300 mm size (inside) as per standard design: |
| 85 | a) 100x100 mm size P type |
| 86 | i) With common burnt clay F.P.S. (non modular) bricks of class designation 3.5 |
| 87 | 38) Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 88 | a) Inside size 90x80 cm and 45 cm deep including pre-cast R.C.C. manhole cover and frame (LD-2.5) Rectangular shape 600x450 mm internal dimensionsinternal dimensions |
| 89 | i) With common burnt clay F.P.S. (non modular) bricks of class designation 3.5 |
| 90 | 39) Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 91 | a) L D - 2.5 |
| 92 | i) Rectangular shape 600x450 mm internal dimensions |
| 93 | 40) Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading |
| 94 | for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 95 | a) For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 96 | 41) Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 97 | 42) Removal of vegetation at walls/ roofs and floors/ drainage systems/ water supplying stream of the building/ over head tanks or at any location, pouring acid at the effected places and applying any special chemical to affectedarea to prevent future vegetation growth and finishing the same with cement concrete/ repair plaster to match the surface of walls/ floors/ roofs., etc complete as per the directions of Engineer-in-charge. (any cement concrete/repair plasteringdone shall be paid separately) (Uprooting of vegetation alongwith applying/sprayingrequisitechemicalin each location will be measured as one job). |
| 98 | 43) Providing and fixing CPVC ball valve in CPVC pipe line including cutting and jointing with CPVC solvent cement etc complete. |
| 99 | a) 25 mm nominal bore |
| 100 | b) 40 mm nominal bore |
| 101 | 44) Providing and fixing CPVC union in CPVC pipe line including cutting and jointing with CPVC solvent cement etc complete. |
| 102 | a) 25 mm nominal bore |
| 103 | b) 40 mm nominal bore |
| 104 | 45) Providing PVC SWR soil waste and vent pipes conforming to IS : 13592 Type B including jointing with \"T\" shaped seal/rubber ring conforming to IS : 5382 usingsolvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant). (i)Single socketed pipe (couplings, other accesories/Fittingswill be paid seperately)(Any scaffolding required will be paid seperately ) |
| 105 | a) 110mm diameter |
| 106 | b) 75mm diameter |
| 107 | 46) Providing, laying and jointingunplasticised PVC Eco-drain unique wall structure (Number of \"holes\" in the wall thickness in longitudinal direction) pipes/ Manhole chambers/ Gully chambers of Type SN4 of Aashirwad Make or Equivalent conforming to IS : 16098, including joints & fittings with one step CPVC solvent cement, with solvent weld and rubber sealing rings including filling alround pipes up to required thickness with Stone dust/ robo sand/ river sand & testing of joints complete as per direction of Engineer in Charge. |
| 108 | a) Pipes |
| 109 | i) 160 mm diameter |
| 110 | 47)Providing and fixing PVC SWR pipefittings/Accessories conforming to IS : 14735 Type Bincluding cutting & replacing existing damaged CI fittings/accesories and jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. (Any scaffolding required will be paid seperately ) |
| 111 | a) Coupler |
| 112 | i) 110mm |
| 113 | ii) 75mm |
| 114 | b) Plain bend of required degree |
| 115 | i) 110mm bend |
| 116 | ii) 75mm bend |
| 117 | c) Tee with door |
| 118 | i) 110X110X110 |
| 119 | II)75X75X75 |
| 120 | d) Door bend |
| 121 | i) 110mm |
| 122 | ii) 75mm |
| 123 | e) Single Y with door of required degree |
| 124 | i) 110X110X110 |
| 125 | ii) 75X75X75 |
| 126 | 48) Providing and fixing unplasticised -PVC pipe clips of approved design for fixing ofSWR PVCpipesby means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting chases in brick work, fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall with rich cement plaster 1:3etc. complete. |
| 127 | a) 110mm |
| 128 | b) 75mm |
| 129 | 49) Providing and fixing C.P Brass waste with all accessories etc complete as directed by the Engineer-in-Charge |
| 130 | a) 32mm diameter |
| 131 | 50) Providing and fixing sanitary fittings/appliances by removing the existing damaged sanitary and water supply fittings and replacing them with these new fittings including necessary white lead/ lead wool etc complete as directed by the engineer in charge. |
| 132 | i) Providing and fixing PTMT health faucet with PVC pipe including holder complete etc., as directed by the Engineer-in-charge. |
| 133 | ii) C.P. brasstwo in one bib cock 15 mm nominal bore. of approved quality conforming to IS:8931: |
| 134 | 51) Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 135 | 52) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 136 | a) 1:5:10(1 cement:5 Course sand :10 Brick aggregate of 40mm nominal size) layed in layers by consolidating each layer. All complete all as per direction of Engineer in charge |
| 137 | 53) Providing and fixing rectangular shaped urinal framelesspartition with 8mm thickfrosted toughened glassof required sizeincluding patch fittings of CP Brass or SSfor supporting wall and/or flooras per manufacturerspecfications complete as per direction of Engineer-in-charge .a) 450X900mm |
| 138 | 54) Cleaning of existing over head tank/ underground water storage tank by mechanical method of specified TANKCLEAN process in stages: (1) Empty the tank/ sump and make it to near dry, (2) wash the tank internal surfaces and top of the tank with fresh water and clean/ rinse the inside surfaces of side walls, ceiling and floor surfaces perfectly by removing all scalling, fungus etc., with rotary jet mechanism, (3) Removing/ cleaning mud, silt, waste, sludge and garbage from the tankwith sludge pump/ vaccum cleaner and disposing outside the building, (4) After drying applt UV radiation with specified equipment in the tank for 15 minutes to kill the harmfull bacteria etc., complete all as per directions of the Engineer-in-charge. |
| 139 | (The rate includes filling of outlets of tank with cotton during cleaning marking of date of painting on the tanks and cleaning of all the dirt/ waste etc., from the terrace and submission of certificate from specialised agency). |
| 140 | 55) Providing and fixing a pair of aluminium louvers holder for holding glass panes ( Powder coating not less than 50 microns) to ventilators of required height with necessary screws etc complete all as per the directions of Engineer-In-Charge. The glass panes and the aluminium frame shall be paid separately. The pair of aluminium louvers shall be fixed to the aluminium frame. Pair (2 Nos) of louvers fixed to each ventilator shall be measured for payment. |