| 1 | M&L for carrying periodical maintenance of DG set of any capacity ( 10 to 30 KVA ) at various location, check as per recommendations of manufacturer including replacement of necessary filters any type such as oil filters, fuel filters, screen filter, Eng lubricating oil, topping up radiator coolent and battery water etc. all as directed by Engr-in-charge.Note 1.Periodicity/ location of the DG set shall be intimated by the Engr-in-charge as and when required. 2. Work shall be carried out at site at different installation. |
| 2 | All as per serial item No 01 above but for 40 to 63 KVA DG Set |
| 3 | All as per serial item No 01 above but for 75 to 100 KVA DG Set |
| 4 | All as per serial item No 01 above but for capacity 160 KVA DG Set |
| 5 | M & Lfor FIP & Nozzle repairing as per standard calibration procedure and norms forDG set of capacity above 10 KVA and upto 30 KVA includingpressure cleaning of fuel nozzles , replacement of minor spares, gasket etc and refixing serviceable items including transportation the pump set from site to workshop and workshop to site alongwith testing at site complete all as specified and directed. |
| 6 | All as per serial item No 05 above but for 40 to 63 KVA DG Set |
| 7 | All as per serial item No 05 above but for 75 to 100 KVA DG Set |
| 8 | Supply and fixing of battery charger from the DG set carefullyand fitting ofcharger kit for DG set of capacity 40KVA and upto 63 KV and testing for smooth functioning complete all as specified and directed. |
| 9 | All as per serial item No 08 above but for 75 to 100 KVA DG Set |
| 10 | M& L for unsv self starter from DG set of capacity 10 to 40 KVA for repair and servicing of the self starter including replacement/rewinding of commutator, carbon brush set with holder king pin holder, armature, choke nut body screen clutch plate assembly and solenoid coil etc incl transportation of the same from site to workshop and workshop to site alongwith testing at site complete all as specified and directed. |
| 11 | All as per serial item No 10 above but for 63 KVA DG Set |
| 12 | All as per serial item No 10 above but for 75 KVA DG Set |
| 13 | M&L for replacing of water hose kit for radiator of DG set of capacity upto 40 KVA complete all as specified and as directed. |
| 14 | All as per serial item No 13 above but for capacity more than 40 KVA to 75 KVA DG Set |
| 15 | M&L for replacing of water hose for radiator with clamp complete all as specified and as directed. |
| 16 | M&L for removing radiator from engine, cleaning and descaling the tanks and fins, reparing the fins / blocking the leaking fins, refixing the same to engine, filling with new coolant to the capacity of radiator, testing complete for DG set of capacity 100 KVA complete all as specified and as directed. |
| 17 | All as per serial item No 16 above but for 62.5/63 KVA DG Set |
| 18 | All as per serial item No 16 above but for 40 KVA DG Set |
| 19 | M&L for preparation of old painted body surface of 10 to 30KVA DG set and applying two coat of synthetic enamel paint as per colour code to the body of DG set and alternator and red colour to the belt guard including writing MES/SM Nos complete all as specified and directed. |
| 20 | All as per serial item No 19 above but for 40 to 75 KVA DG Set |
| 21 | M&L for cleaning of fuel tank of any capacity by draining out diesel and cleaning internally with the help of cleaning agentand compressed air , drain out the sludge/foreign matter deposited inside the diesel tank of DG set from 10 to30 KVA capacity complete complete all as specified and as directed. |
| 22 | All as per serial item No 21 above but for 40 to 63 KVA DG Set |
| 23 | All as per serial item No 21 above but for 75 to 100 KVA DG Set |
| 24 | All as per serial item No 21 above but for capacity 160 KVA DG Set |
| 25 | S&F in repair acid lead battery, for DG set, 12V/100AH complete all as specified and as directed. |
| 26 | M&L for servicing the control pannel of DG sets of 62.5/63 KVAcleaning and adjusting the time setting, cleaning the contact, setting the relays, meters etc and making for smooth functioning of the panel complete all as specified and as directed. |
| 27 | All as per serial item No 26 above but for 75 to 100 KVA DG Set |
| 28 | M&L for repair to alternater complete by dismantling and cutting winding, cleaning, polishing, welding work and re-winding with suitable size and gauge of copper enamelled winding wire complete greasing, replacement of carbon brush, varneshing etc and testing after repair of 10 to 30 KVA DG Set including testing after repair complete all as specified and directed. |
| 29 | All as per serial item No 28 above but for 75 to 100 KVA DG Set |
| 30 | Supply of following spares parts (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing)for 10 to 30 KVA capacity DG Sets:- |
| 31 | Benjo bolt(03.040.06.0.00) |
| 32 | Benjo bolt(34.023.06.0.00) |
| 33 | 1.1 Ltr duel fuel filter |
| 34 | Spin on filter for lubrication oil |
| 35 | Air cleaner safety element |
| 36 | AIr cleaner primary element |
| 37 | Koel care oil 13 litres CAN |
| 38 | Leak off pipe sub assembly |
| 39 | Fuel pipe for feed pump to filter |
| 40 | Flexible pipe(1 mtr long) |
| 41 | Fuel pipe (4 mtr) |
| 42 | Fuel pipe for tank to feed pump |
| 43 | Battery cable assembly |
| 44 | Koel care coolent 5 litre can |
| 45 | Supply of following spares parts (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing) for 40 to 75 KVA capacity DG set:- |
| 46 | Battery cable set |
| 47 | Lub oil filter |
| 48 | Fuel filter |
| 49 | Air filter |
| 50 | V belt |
| 51 | Coolant 1500 |
| 52 | Lub oil 15 Lt pack |
| 53 | UVR 7/6 |
| 54 | AVM pad |
| 55 | Fuel pipe set |
| 56 | Supply of following spares parts (MAKE- Kirloskar/ L&T/ Cummins/ Ashok Leyland/ as existing)for 100 to 160KVA capacity DG Sets:- |
| 57 | Hinges LH |
| 58 | Hinges RH |
| 59 | +ve battery cable 1.4 mtr long |
| 60 | -ve battery cable 1.2 mtr long |
| 61 | Lub oil filter(232V12) |
| 62 | Filt. Element with O ring |
| 63 | FLTR INSRT with O ring |
| 64 | Primary filter element |
| 65 | Secondary filer element |
| 66 | Greaves Lub oil 10 Lt Pack |
| 67 | Coolant additive 5 Lt pack |
| 68 | Cogged belt AX43-1143L |
| 69 | AVRSR7/6-ph(200/250S/250M) |
| 70 | AVM 508G mix 03 blue code |
| 71 | Leak off plastic 4G11 STD |
| 72 | Pipe, FIP oil supply |
| 73 | Plastic pipe for fuel filter |
| 74 | Turbo oil drain pipe(4G11TAG3) |
| 75 | Turbo oil inlet pipe side ope |
| 76 | Fuel pipe-M14 Banjo,1100 L,RB |
| 77 | Combined leak off pipe-FOR |
| 78 | Disconnecting AC supply, dismantling, and openingservo voltage stabilizer having capacity 100 KVA to 250 KVA, servicing, repair/replacement of unserviceable parts found defective during repairing, re-assembling the same after repairing, testing, andcommissioning complete all as per specified and as directed by Engineer-in-charge.NOTE :- Parts replaced of voltage stabilizer shall be measured and paid separetly under respective items. |
| 79 | Supply only following worn out parts of existing size for Servo stabilizer having capacity 30 KVA to 100 KVA. Make: Volina/ Blue Line or equivalent:- |
| 80 | Repair/replacement of indicator of different colour. |
| 81 | Repair/replacement low cut switch suitable size & capacity or as per existing. |
| 82 | Repair/replacement high cut switch suitable size & capacity or as per existing. |
| 83 | Repair/replacement R C network suitable size & capacity or as per existing. |
| 84 | Repair/replacement carbon set suitable size & type or as per existing. |
| 85 | Repair/replacement carbon bush suitable size & type or as per existing. |
| 86 | Repair/replacement/rewinding dimmer suitable size & capacity or as per existing. |
| 87 | Repair/replacement/rewinding buckbook transformer suitable size & capacity or as per existing. |
| 88 | Repair/replacement copper lugs of suitable size or as per existing size. |
| 89 | Repair/replacement PCB of suitable size & capacity or as per existing. |
| 90 | Repair/replacement servo motor of suitable size & capacity or as per existing. |
| 91 | Repair/replacement triger transformer of suitable size & capacity or as per existing. |
| 92 | Repair/replacement digital volt meter. |
| 93 | M & L for repair to ACservo voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating,copper lugs,and nuts and bolts etc and reassembling and testing complete all as specified and directed of capacity 30 KVAvoltage stabilizer complete all as specified and as directed.Note 1.Periodicity/ location of the DG set shall be intimated by the Engr-in-charge as and when required. 2. Work shall be carried out at site at different installation. |
| 94 | M & L for repair to ACservo voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating,copper lugs,and nuts and bolts etc and reassembling and testing complete all as specified and directed of capacity 100 KVAvoltage stabilizer |
| 95 | M & L for repair to ACservo voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating,copper lugs,and nuts and bolts etc and reassembling and testing complete all as specified and directed of capacity 300 KVAvoltage stabilizer |
| 96 | M&L for topping up of transformer oil of dielectric strength more than 50KV in servo voltage stabilizer all as specified and directed. |
| 97 | M & L for repair to AC voltage stabilizer by removing burnt out entire copper winding from coils and rewinding of the same coil with super enameled copper wire of appropriate gauge as per original including providing insulation paper, cotton tape, varnishing heating, reassembling, and testing complete all as specified and directed of capacity 3.0 KVA to 5.0 KVAvoltage stabilizer, complete all as per specified and as directed by Engineer-in-charge. |
| 98 | M&L for minor repair of Voltage Stabilizer of 3 to 5 KVA Capacity of any MAKE including replace-ment ofRelay, Capacitors, Switches, Voltmeters and Testing, etc., complete all as specified and as directed. (MAKE of spare parts- Havells/ L&T/ Siemens/ as existing) |