Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for laying of cables, pipes, erection of poles, structs/stays etc not exceeding 10 sqm and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified. |
| 3 | Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified. |
| 4 | Comprehensive maintenance and servicing including testing of RO Plant of capacity (01 No) including washing, cleaning, sedimentation, filteration, disinfection process, pressure pumping set & chlorine dosing unit at AF Stn Ramgarh area so as to supply qualitative water at permissible level of TDS complete all as specified and directed.Note :- Spares required for replacement will be measured and paid seperately under respective items here-in-this schedule. |
| 5 | S & F in replacement of automatic digital starter suitable for RO Plant of capcity 1000 ltr/Hr fixed in repair complete all as specified and directed. |
| 6 | S & F in replacement of Water flow meter (rotameter) suitable for RO Plant of capacity 1000 Litre/hour fixed as in repair complete all as specified and directed. |
| 7 | S & F in replacement of Jambo micro filter candle for RO Plant (threaded), 4.50\" (Inches) wound complete as per sample all as specified and directed |
| 8 | Supply and pouring antiscalant soluton (suitable for RO plants) complete all as specified and directed. |
| 9 | Supply & pouring PH corrector /Booster for RO plants complete all as specified and directed. |
| 10 | S & F in replacement of Membrane suitable for RO Plant, flow 250 LPH, rejection (%) : 99.67, Model No. CPA2-4040 Nitto of Hydranautics or equivalent of Daw/GE, fixed as in repair complete all as specified and directed. |
| 11 | S & F in replacement ofDozing pump feeder for injecting PH booster, Antiscalent, chlorine with dosing Rate : 6 LPH @ 4 Kg/Sqcm, 400 Max Stroke/ Minute fixed as in repair complete all as specified and directed. Make: Aqua/Aventura or equivalent. |
| 12 | Disconnection of all pressure tubes from the RO Plant and taking out all membranes from pressure tubes cleaning the same with citric acid (low pH) and solium hyppchloride (high pH) and complete washing with RO water and re-assembling the same complete all as specified and directed. |
| 13 | S & F in replacement for UV Lamp for capacity 20 watt for UV Filter sutiable for RO of capacity 1000 LPH fixed as in repair complete all as specified and directed. |
| 14 | S & F in replacement ofPlastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water, suitable for operation through suitable feeder in pressurised line stequa 411E fixed as in repair complete all as specified and directed. Make: Declibac,Potter & Watts/Brio Zingor equivalent |
| 15 | S & F in replacement of500 Litre capacity Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe including disconnecting & taking down the existing water tank complete as specified in SSR Part-I |
| 16 | Testing of RO water sample for chemical examination of drinking water (such as coliform bacteria, nitrates, pH value, sodium, chloride, fluoride, sulphate, iron magnase, hardness etc) by authorised government laboratory complete for Ramgarh RO plant all as specified and directed. Note: Water sample collect and testing to be done every Monthly basis and report of the same to be submitted to Engineer-in-Charge and GE. |
| 17 | M&L for Galvanized steel water tubing medium grade of 15mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed. |
| 18 | M&L for Galvanized steel water tubing medium grade of 20mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 20mm bore, complete all as specified and directed. |
| 19 | M&L for Galvanized steel water tubing medium grade of 25mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 25mm bore, complete all as specified and directed. |
| 20 | M&L for Galvanized steel water tubing medium grade of 40mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed. |
| 21 | M&L for Galvanized steel water tubing medium grade of 50mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 50mm bore, complete all as specified and directed. |
| 22 | M&L for Galvanized steel water tubing medium grade of 80mm bore with & including all necessary fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 80mm bore, complete all as specified and directed. |
| 23 | M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 50mm bore pipe line fixed as in repair complete all as specified & directed. |
| 24 | M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe line fixed as in repair complete all as specified & directed. |
| 25 | M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe line fixed as in repair complete all as specified & directed. |
| 26 | M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 20mm bore pipe line fixed as in repair complete all as specified & directed. |
| 27 | M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 15mm bore pipe line fixed as in repair complete all as specified & directed. |
| 28 | S & F in replacement ofCast iron body sluice valve heavy duty class ‘PN-1.6’, 100mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, gun metal spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing including dismantling of sluice valve complete all as specified & directed. |
| 29 | Preparation/cleaning of old painted steel surface of any description such as suction line, delivery line, priming line or any other pipe line/channel plates complete with scraping out old painted surface and after that marking of flow direction along with painting as per colour code complete all as specified and directed. (Make of Paint : Asian/Berger or equivalent) |
| 30 | Rectification of Leakage 100mm bore CI/DI pipe linesby necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures with D-joint or MS clamp of minimum 6 inch including rubber cushioning, 5mm thick and 100mm wide with hole drilled for nut bolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed.Note:Cost of JCB for lifting of pipe/T&P for removing of water for repair will be part of quoted rates. |
| 31 | Rectification of leakage in water main pipe line including necessary excavation in any type of soil, in any situation including bailing out leakage water by suitable measures, repair to existing Galvanised Iron pipes lines following sizes and cutting threading, for addition & alternation and for insertion of fittings/accessories (bend, elbow & Tee) complete all as specified and directed. (a) 15/20mm bore GI Pipe linesNote:- (i) The rate is deemed to include for one fitting/special (complete unit) as required at site. (ii) Rate quoted shall be deemed to be inclusive of necessary dewatering and excavation (Upto one length of 6 RM) filling making good the existing surfaces with the necessary T&P, accessories of appropriate size as required complete all as directed. |
| 32 | -Ditto- as above item no.31.00 but 25mm bore GI Pipe lines |
| 33 | -Ditto- as above item no.31.00 but 40mm bore GI Pipe lines |
| 34 | -Ditto- as above item no.31.00 but 50mm bore GI Pipe lines |
| 35 | -Ditto- as above item no.31.00 but 80mm bore GI Pipe lines |
| 36 | Opening and reassembling of monoblock pump after rewinding & replacement worn out spare parts including taking out the burnt winding and rewinding of monoblock pump (motor) of capacity 15/20 HP, three phase, 415 volts with solid copper conductor (wire) superior quality of approved make, size and number of wire as per existing including insulation material, minor spares and reassembling the components & testing for function ability, complete all as specified and directed.Note :- Unit rate quoted by the tenderer shall be deemed to be include for all minor spares/extras.The decision of Accepting Officer regarding minor spares/extras shall be final, conclusive and binding. |
| 37 | Opening and reassembling of monoblock pump after rewinding & replacement worn out spare parts including taking out the burnt winding and rewinding of monoblock pump (motor) of capacity 7.5/10 HP, three phase, 415 volts with solid copper conductor (wire) superior quality of approved make, size and number of wire as per existing including insulation material, minor spares and reassembling the components & testing for function ability, complete all as specified and directed.Note :- Unit rate quoted by the tenderer shall be deemed to be include for all minor spares/extras.The decision of Accepting Officer regarding minor spares/extras shall be final, conclusive and binding. |
| 38 | Opening and reassembling of monoblock pump after rewinding & replacement worn out spare parts including taking out the burnt winding and rewinding of monoblock pump (motor) of capacity 2 HP, three phase, 415 volts with solid copper conductor (wire) superior quality of approved make, size and number of wire as per existing including insulation material, minor spares and reassembling the components & testing for function ability, complete all as specified and directed.Note :- Unit rate quoted by the tenderer shall be deemed to be include for all minor spares/extras.The decision of Accepting Officer regarding minor spares/extras shall be final, conclusive and binding. |
| 39 | Maintenance and servicing of DG Set of capacity 160 KVA complete including draining out of Diesel from tank, cleaning the tank throughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber throughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petrolium jelly to battery terminal posts & brass connectors, changing of V-Belts, changing of rubber housing and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc. adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the maufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed.Note :- Cost of diesel for testing shall be deemed to be included in the quoted rate. |
| 40 | Maintenance and servicing of DG Set of capacity 15 to 25 KVA complete including draining out of Diesel from tank, cleaning the tank throughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber throughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petrolium jelly to battery terminal posts & brass connectors, changing of V-Belts, changing of rubber housing and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc. adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the maufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed.Note :- Cost of diesel for testing shall be deemed to be included in the quoted rate. |
| 41 | Taking down of existing u/s street light of any type,any make,any wattage from pole at nay height etc any type complete after removing from existing mounting arrangement/street light bracket etc and refixing the same after necessary repair/replacement of unserviceable light with new fittings/component etc complete all as specified and directed by /engr-in-charge.Note : (i) Replacement and refixing of unserviceable compoent required at site will be measured and paid seperately under relevant item as supply only.(ii) Fitting shall be connected with existing electric wire/cable in case of existing wire/cable found unserviceable shall be measured and paid in relevant items as supply only.(iii) Any type of ladder required for dismantling of light from pole shall be arranged by the contractor.(iv) In case street light not working due to any fault in the cables,carbon in terminals/joints or fault in overheadlines the same shall be cleared by the contractor and thye cost of the same shall deemed to be included in the quoted rate.(v) The contractor shall provide suitable vehicle to tradesman attending complaint of street lights.(vi) The copntractor or his supervisor will obtain complaint from JE/Engr-in-charge on daily basis and compaint shall be attended and rectified within 24 hrs of complaint issued by JE/Engr-in-charge failing which a penal recovery of 2 times of the quoted rates shall be made from RAR for each not attended or rectified complaint. |
| 42 | Supply only electronic driver suitable for street light of capacity 60 watts as per existing complete all as required at site. |
| 43 | Supply & fixing and connecting elastomer insulated flat sheathed muticore industrial flexible cable with bright annealed copper conductor 1100 volts grade cable of size 1.5 Sqmm 3 Core confirming to IS 694-1990 including taking down of old unserviceable connection wire complete all as specified and directed. |
| 44 | Supply and fix junction box made out of FRP with IP 55/IP65 protection of size not less than 200 x 140 x 95 mm (inside dimensions) having 5 terminals mounted on din rail for termination of cable with necessary nuts,bolts,including 02 Nos cable gland,01 No DIN rail mounted of 01 MCB SP 6 amp 10 KA and including taking down of existing U/S junction box of any type all as directed. |
| 45 | Supply & fixing in repair energy efficient LED street light fittings of capacity not less than 60 Watts pressure die cast aluminium housing & toughned glass with IP-66 degree of protection individuals LEDs should have lenses for better throw across & along road range 140-280 Volts fittings should be provided 10 KV surge protection external and apart from this surge arrestor driver should have additional 4 KV surge protector inbuilt in driver formaximum protections,should have lumens output of 110 lumens per watt minimum protection facility in drivers,drivers should be potted type for viberation proof performance & includings making electrical connections all as directed. |
| 46 | Supply & fixing in replacement street light/security light bracket made out of 40 mm dia galvanised steel tubing medium grade 1.5 m long including bending if required as direct,02 Nos clamps made out of MS flat iron 40 x 6mm of suitable size fixed with bolts,nuts and washer including drilling holes and grouting with the same for fixing bolts complete(Rate quoted by contractor shall deemed to include for nuts & bolts) |
| 47 | Supply & fixing of nature switch smart timer based automatic street light control panel.The panel should be suitable enough to take single phase load of 10 Kw with incoming-outgoing MCBs of 63 Amps and contactors & circuit wiring (copper) of 16 Sqmm.Nature switch timer smart timer should be maintenance free in design & settings accessible via a mo0bile app with bluetooth connectivity.The mobile app should allow users to customize on/off timing based on nature light (sensor),local sunset/sunrise (ASTRO) and time.The mobile app should also have facility to set input voltage range.The smart timer along with suitable power contactors and incoming-outgoing MCBs should in enlosed in a pole/wall mountable rust proof,electric shock proof,termite proof and FR grade SMC enclosure confirming to IP-66.The circuit should also have provision for manual operation (sensor bypass option) controlling etc. Model No Navdeep-66-10W1P |
| 48 | Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of UG cable / pole etc and getting out including forming bottom surface to required level and gradient in soft/dense soil complete all as specified and as directed. |
| 49 | Returning filling in, excavated soil including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified. |
| 50 | Removing excavated materials/soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge. |
| 51 | Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 3.5 core x 70 Sqmm complete all as specifed and as directed. Make : Polycab/KEI/HavellsNote: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and paid under appropriate items. |
| 52 | Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 3.5 core x 35 Sqmm complete all as specifed and as directed. Make : Polycab/KEI/HavellsNote: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and paid under appropriate items. |
| 53 | Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 4 core x 25 Sqmm complete all as specifed and as directed. Make : Polycab/KEI/HavellsNote: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and paid under appropriate items. |
| 54 | Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 4 core x 16 Sqmm complete all as specifed and as directed. Make : Polycab/KEI/HavellsNote: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and paid under appropriate items. |
| 55 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed. |
| 56 | M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed.Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for. |
| 57 | Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed. |
| 58 | Taking down old U/S existing DB SPN 8 way & TPN DB 4 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 59 | Disconnecting and taking down unserviceable submain wiring form TPN DB to SPN DB and SPN DB 8 way to SPN DB 4 Way complete & removing U/S items from site complete all as directed by Engineer-in-Charge. |
| 60 | Taking down the old unserviceable Fan regulator from site complete all as directed by Engineer-in-charge. |
| 61 | Taking out carefully earthing set complete of any type including earthing wire & removing U/S items from site complete all as directed by Engineer-in-charge. complete all as specified and directed by Engineer-in-charge. |
| 62 | M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colourto coomon earth dolly laid/drawn into and includingnon metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in& including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed:Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE. One light/fan point (Ceiling Fan/Exhaust Fan) controlled by oneswitch |
| 63 | -Ditto- all item as per Ser No 58 above butOne multi pin socket 5/6Amps,Independent. |
| 64 | -Ditto- all item as per Ser No 58 above One 5/6 amp socket outlet on the same boardcontrolled by another switch. |
| 65 | All as per item No 6 here -in- before but forone 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 sqmm single corePVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed . |
| 66 | S&F switch Modular type, 5/6 Amp, 1 module single pole one way, 230 Volts, Modulartype complete all as specified and as directed by Engr- in -charge. |
| 67 | S&F switch Modular type, 15/16 Amp, 1 module single pole one way, 230 Volts, Modulartype complete all as specified and as directed by Engr- in -charge. |
| 68 | S&F socket outlet 3 Pin5/6 Amps modular type, 2/3 pin combined 2 module230 Voltscomplete all as specified and directed by Engr-in-Charge. |
| 69 | S&F socket outlet 3 Pin6/16 Amps modular type, 2/3 pin combined 2 module230 Voltscomplete all as specified and directed by Engr-in-Charge. |
| 70 | S&F ceiling rose, surface backelite , three terminal AC, 230 voltcomplete all as specified. |
| 71 | Taking down Ceiling fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of ceiling fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge |
| 72 | Supply and fixing fan step regulator modular type,120W -2 module electronicsocket typefive step controlled 230V AC 50 Hz forcomplete all as specified and directed by Engr-In-Charge. |
| 73 | Taking down Exhaust fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of Exhaust fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge |
| 74 | Taking downLED tube light fitting, 1x 20watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 75 | Refixing LED tube light fitting, 1x 20watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 76 | S&F LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. |
| 77 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 78 | M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engr-in-Charge. |
| 79 | Supply and fixing in replacement LED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 80 | S & F in replacement double door, sheet metal enclosure,powder coated for MCB DB SPN 4 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 81 | S & F in replacement double door, sheet metal enclosure,powder coated for MCB DB SPN 8 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 82 | S & F in replacementdouble door, sheet metal enclosure,powder coated for MCB DB TPN DB 4 way fittedwith neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. |
| 83 | S & F in replacement MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 84 | S & F in replacement MCB SPN, 5-32 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 85 | S & F in replacement MCB TPN 40-100Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge. |
| 86 | M&L for submain wiringwith 2 runs of6.0 Sqmm (nominal area) size main cable & 1 runs of 6.0 Sqmm size earth continuity conductor single core PVC insulated unsheathed FRLSH multistranded copper conductor 1100 volt grade ISI marked cable drawn through & including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified & directed.Note :-(i) 02 runs of 6.0 Sqmm size main cable, 01 run of 6.0 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run length for payment purpose.(ii) Cost of cutting/leaving forming chases for conduits and making goodin CM 1:4 shall be included in quoted rate of this item. |
| 87 | M & L for sub main wiring with two single core 4.00 Sqmm PVC insulated unsheathed cable multi-stranded FRLS copper conductor drawn through and including PVC conduit pipe of suitable size not less than 25mm with all fittings and fixing accessories on roof, walls, ceiling etc. including 4.00 Sqmm PVC insulated unsheathed single core solid copper conductor earth wire complete including taking down old sub main wiringall as specified and directed (Note:(i) Two run of single core cable and one run earth wire, pvc Conduit will be measured as one length)(ii) Cost of cutting/leaving forming chases for conduits and making goodin CM 1:4 shall be included in quoted rate of this item. |
| 88 | M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion. |
| 89 | Taking down GI Pipe any grade 15mm dia etc complete |
| 90 | -Ditto - all item as per Sern O 83.00 above but20mm dia |
| 91 | S&Fsteel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm all as spfd |
| 92 | All as per above item but bore of tube20mm |
| 93 | Re-fixing old steel water tubing of 15mm bore and connection in new or old position fixed to the walls, ceiling or laid in floor complete all as specified and directed. |
| 94 | All as per above itembut20mm bore and -ditto- |
| 95 | S& F in repair wash hand basin vitreous chinawash basin white flat back size 550x400 including supplied and fixed angle iron brakets errecting stand compleete all as specified. |
| 96 | S&F in repair sink with drainage board made of stainless steel 1 mm thick with plug and washers and waste pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackt and connacting union to pipe over all size 495 x 420 mm and bowl size 410x330x160 mm compleete all as specified |
| 97 | S&F 500 ltrs capacity rotational moulded polyethylene water storage triple layer white tanks (cylindrical verticle with closed top) hoisted and fixed in position including dismantling old U/S water tank complete all as specified. |
| 98 | S&F 1000 ltrs capacity rotational moulded polyethylene water storage triple layer white tanks (cylindrical verticle with closed top) hoisted and fixed in position including dismantling old U/S water tank complete all as specified. |
| 99 | Cleaning and removing all scale and dirt etc from tanks and mouth and circulating pipes etc, exc 250 ltr & n.exc 500ltrs capacity and marking date of cleaning with paint. |
| 100 | Cleaning and removing all scale and dirt etc from tanks and mouth and circulating pipes etc, exc 500 ltr & n.exc 1000ltrs capacity and marking date of cleaning with paint. |
| 101 | S&F O.H water tanks Cover of 500 litrs /1000 ltrs Capacity including locking arrangements and removing old broken cover |
| 102 | Supply and fixing in repair wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm complete all as specified and directed. |
| 103 | Hacking out old broken glass any thickness size, quality or description from wooden frame glazed with puty or fixed with beads. |
| 104 | Supply and fixing as in repair 3mm thick sheet glass ordinary quality and glazing with oil putty or aluminium beads in square not exc 0.50 sqm in each pane, complete all as specified and directed. |
| 105 | S&F as in repair 4mm thickfigured glass pin head type and glazing with oil putty or aluminium beads and rubber in squares and aluminium beadingn. exc 0.50 Sqmtr each pane complete all as specified and directed by Engr-in-charge. |
| 106 | Demolition of cement concrete in ground floor and paving n.exc. 15cm thickness (below or above ground level) un reinforced. Complete |
| 107 | M&L 75MM thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as sub base. |
| 108 | Factory made chequered cement concrete tiles, 25cm x 25cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 15mm thick screed bed in cement and sand mortar 1:6 cement mortar bedding complete all as specified and directed. |
| 109 | Machine pressed factory made rubber moulded precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cement with pigment including 25mm thick machanicaly compacted thickness of sand bedding below paver tiles laid to required level & slope complete all as specified and directed. |
| 110 | Anodized aluminium snap grid frame work for false ceiling as per manufacturer\"s instructions with hangers from RCC soffit/steel trusses with 6mm dia GI rod (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long with including exposed metal frame ceiling with 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 600mmx 600mm in size, fixed with nail to timber frame work or with staples on snap grid in ceiling, flat or sloping and including dismantling and taking down old unserviceable ceiling board complete all as specified and directed. |
| 111 | Rendering 10mm thick in cement and sand mortar (1:6) on stone masonry or concrete block masonry surfaces and finished even and smooth (without using extra cement) including taking down cement plaster complete all as specified and directed. |
| 112 | Rendering 15mm thick in cement and sand mortar (1:4) on stone masonry or concrete block masonry surfaces other than fair faces of concrete/brick and finished even and smooth (without using extra cement) including taking down cement plaster complete all as specified and directed. |
| 113 | 5mm thick cement plaster in cement and sand mortar (1:3) on concrete surfaces of ceiling, soffits of chajjas/drop & roof projection facia finished even and smooth without using extra cement including taking down old cement plaster complete all as specified and directed. |
| 114 | M&L for preparation of new plasteredsurfaces of Wall any description and applying two coats of oil bound distember over chalkwhitening on plastered surfaces. |
| 115 | M&L for preparation of new surface of walls and apply two coats of cement base paint over a coat of primer |
| 116 | Preparation of new plastered surface and applying three coats of white wash on celing surfaces |
| 117 | M&L preparation of old decorated surfaceson ceiling surface including brooming down and cleaning the surfaces and applying one coat of white wash(any height) complete all as specified & as directed. |
| 118 | M&L preparing old decorated surface of walls including brooming down and cleaning the surfaces and applying two coat of distemper (Oil emulsion) of approved tint all (any height) complete all as specified & as directed. |
| 119 | M&L preparation of old decorated surfaces of walls and applying one coat of cement base paint of approved tint(camoflage pattern)(any height) complete all as specified & as directed. |
| 120 | M&L for preparation of old treated/ decorated external wall/roof surfaces of any storeys/ any height of any description and applying one coat of exterior emulsion paint (weather coat) 1st quality in different tints/shades in sigma/ camouflaging pattern as approved complete all as specified & as directed. |
| 121 | M&L preparing old painted wooden surface of any description any width or girth and applying one coat of synthetic enamel paint of approved tint (any height) complete all as specified & as directed. |
| 122 | M&L preparation of old painted steel surfaces of any description any width or girth and applying one coat of synthetic enamel paint of approved tint (any height) complete all as specified & as directed. |
| 123 | Dismantlingofexisting water proofing roof treatment any type, and in any location up to existing RCC Slab by Chiesling, drilling, scraping and any description and in any position and thrown awaycomplete all as directed by Engr in Charge . |
| 124 | M&L for 20mm thick cement screed/plaster in cement mortar 1:4, including finishing even and smooth with out using extra cement mixed with water proofing compound @3% by weight of cement over cleaned roof surface, as in grading to RCC roof surface,complete all as specified.Note -Water proofing compound shall be measured and paid separately. |
| 125 | Supply only integral water proofing compound complete all as specified and directed |
| 126 | M&L aplying evenly one coat of binding material using blown type bitumen confirming to IS-702 Grade 85/[email protected] kg/Sqmover one coat of cold bituminous oil based primer (IS:3384)(as approved by Engineer -in -charge)@ 250 gm/sqm over plaster surfacesincluding cleaning surfaces of complete all as specified. |
| 127 | M&L For APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface byLPG torched forched application complete all as specified. |
| 128 | M & L PCC (1:2:4) type B-0 using 12.5mm graded stone agg as in Roof padding,or similar work complete all as specified & directed |
| 129 | S&F as in repair 20 mm dia ball valve ,high pressure of PTMT with epoxy coated, aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minium wt-210 gms) |
| 130 | S & Fixed in repair 10 ltr cap. PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 131 | S&Fin repairs white coloured vitreous china urinal half stall type with 40mm size chromium plated waste coupling with long screwed shanks and fly nuts flange end bedded in red lead. |
| 132 | S&F in repairs white coloured vitreous china wash down water closet pan (Pedestal pattern) with and including plastic water closet seat closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device. |
| 133 | M&L for repair vitreous china sqatting pan \"orissa\" pattern of size 580x440mm white with integral foot rests, P or S trap etc complete |
| 134 | S&F in repair low density polyethylene pipes 32MM(LDPE) of pressure rating 6 Lg/CM2 40mm dia fixed complete to walls, ceiling or in floors etc complete. |
| 135 | S&F in repair flexible PVC waste pipe of 32mm dia fixing complete |
| 136 | S & F in repair stainless steel curtain rails, with fixing brackets, stops, rollers etc. complete all as directed by Engr-in-charge. |
| 137 | S & F in repairs 6 mm thick Plywood grade BWR, type BB for covering of window complete all as specified and directed by Engr-in-charge. |
| 138 | S & F in repairs 150mm long aluminium anodized tower bolt complete all as specified and directed. |
| 139 | S & F in repairs Aluminium Sliding door bolt- 300mm long complete all as specified and directed. |
| 140 | S & F in repairs aluminium handle 125mm long complete all as specified and directed. |
| 141 | S & F in repair aluminium (extruded section body) door closer hydraulically regulated universal type suitable for door shutters of 851 to 1000mm in width fixedcomplete all as specified and directed. |
| 142 | S & F in repairs 15mm bore of pipe fancy type chromium plated stop cock cast copper alloy, screwed doen, high pressure, screwed bith ends for iron pipe or for unions ,with long shank and cup (concealed type) etc complete all as specified. |
| 143 | S&F in repair 15mm bore of pipe fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, screwed down etc complete all as specified. |
| 144 | S&F in repair 15mm bore of pipe fancy type chromium plated pillar tap, cast copper alloy,screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe etc complete all as specified. |
| 145 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm etc complete all as specified. |
| 146 | S&Fixed in repair waste coupling 32 mm dia of PTMT (half or full threaded) |
| 147 | S&F 75mm diameter of outlet PVC (SWR) floor trap, plain with grating includingjointing with solvent cement & jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) etc complete all as specified. |
| 148 | S&F in repair 15mm bore dia bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. |
| 149 | S&Fin repair 15mm bore dia with long body bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. |
| 150 | S&Fin repair 15mm bore dia Pillar taps of PTMT anycolour high pressure screwed for iron pipe and fixed. |
| 151 | S&F 600 X 450mm mirror of selected quality glass mounted on 6mm thick plastic bodyand fixed to wooden plugs with chromium plated screws all as specified.(fixed in repair) |
| 152 | S&F in repairs swivel shower of PTMT any colour with shower 195mm long and 15mm dia etc complete all as specified and directed |
| 153 | S&F in repair peg set 6 (Zinc), Cat Part No BEA-30Prayag or equivalent. |
| 154 | S&F in repairs shelf of PTMT fixed with and including chromium plated screws and wooden/plastic cleats etc complete all as specified. |
| 155 | S&F in repairs liquid soap container of PTMT fixed with and including chromium plated screws and wooden/plastic cleats etc complete all as specified.. |
| 156 | S&F in repairsTowel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms). |
| 157 | M&L for square rubble walling Jodhpur type brought up to courses well bonded, bedded and solidly hearted in cement mortar 1:6 etc including demolition of brick work, stone/boulder or block masonry, built in cement mortar complete all as specified. |
| 158 | Extra over above item for hammer dressing to face stones with maximum depressions on face from a stright edge not exc. 20 mm and dressing face beds and joints as specified to SR walling Jodhpur typebrought upto courses complete all as specified and directed. |
| 159 | M&L for keyed pointingin cement and mortar (1:4) to square rubble masonry coursed or brought upto courses etc complete all as specified and directed. |
| 160 | Fixing only curtain Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc fixed in repair and as directed by Engr-in-Charge. |
| 161 | Fixing only Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc fixed in repair and as directed by Engr-in-Charge. |
| 162 | Fixing only Rotational moulded polyethylene water storage tanks 1000 ltr(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part Ietc fixed in repair and as directed by Engr-in-Charge. |
| 163 | Fixing only Rotational moulded polyethylene water storage tanks 500 ltr(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part Ietc fixed in repair and as directed by Engr-in-Charge. |
| 164 | EXCEPT Tiles only Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade etc fixed in repair and as directed by Engr-in-Charge. |
| 165 | EXCEPT Tiles only Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Gradeetc fixed in repair and as directed by Engr-in-Charge. |
| 166 | Fixing only Flushing cistern and flushing pipe(exclusive of brackets), etc fixed in repair and as directed by Engr-in-Charge. |
| 167 | Fixing only Ball brass valves 15& 20 MM in bore dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule etc fixed in repair and as directed by Engr-in-Charge. |
| 168 | Fixing only Wash down water closet (Pedestalpattern), completeetc fixed in repair and as directed by Engr-in-Charge. |
| 169 | Fixing only Water closet (Squatt pattern) com plete including provision of lime concrete bedding fixed in repair and as directed by Engr-in-Charge. |
| 170 | Fixing only Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe fixed in repair and as directed by Engr-in-Charge. |
| 171 | Fixing only Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe fixed in repair and as directed by Engr-in-Charge. |
| 172 | Fixing only Sinks kitchen or laboratory with plugs, washers and wastes; including beding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe; upto 0.5 sqm each fixed in repair and as directed by Engr-in-Charge. |
| 173 | Fixing only Bib taps of any dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair and as directed by Engr-in-Charge. |
| 174 | Fixing only Stop valves 15&20MM dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair and as directed by Engr-in-Charge. |
| 175 | Fixing only Tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed in repair and as directed by Engr-in-Charge. |
| 176 | Fixing only Door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed in repair and as directed by Engr-in-Charge. |
| 177 | Except tiles only Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors fixed in repair and as directed by Engr-in-Charge. |
| 178 | Fixing only steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm all as spfd and directed by Engr-in-Charge. |
| 179 | M&L for removal of blockage in between WC and nahani trap/WC to Ist manhole / floortrap to nahani trap etc. by flexible roding and removal the all dirt up to a distance of 100 m all as directed.Note : (i) In case a blockage reoccured with in 7 days the same shall be removed without any extra cost of the Govt. (ii) Cleaning of line in between manhole where in the blockage remove shall deemed to incl the rate coated.(iii) If contractor failed to clear the blockage with in 24 hours from the receipt of complaint, a penalty of Rs 50 per day will charge up to 7 days and after 7 days same will be Rs 100.00 till completion of complaint. |
| 180 | M&L for cleaning of septic tank /soak well of 25 users capacity by balling out taking out sludge and removing the sludge to a distance exceeding 1.5 Km but not exceeding 2.00 Km from the camp area and including removing stone patti/RCC cover slab and refixing, complete all as directed. |
| 181 | M&L for cleaning of septic tank /soak well of 10 users capacity by balling out taking out sludge and removing the sludge to a distance exceeding 1.5 Km but not exceeding 2.00 Km from the camp area and including removing stone patti/RCC cover slab and refixing, complete all as directed. |
| 182 | Cleaning and desilting ofmanholes of any size, depth not exc 2.00 mtrby excavating sewage wet/dry soil/tree roots in foul condition and removing the waste in covered vehicles outside MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manhole, placing the cover of manhole in position complete all as specified and directed. |
| 183 | Cleaning of sewage line of 100/150/200 mm bore by roding and flush water in line after roding to clean the line complete all as directed by Engineer-in-Charge. Note:- The contractor shall arrange safaiwala immediately as receipt of complaint and ensure that complaint is resolved within 24 hours and no lapses will be allowed.Note: (i) In case a blockage reoccured with in 07 days ,the same shall be removed without any extra cost to the Govt.(ii) cleaning of line in between manholes where in the blockage remove shall deemed to incl the rate coated. |
| 184 | S&F Providing FRC manhole covers with rectangular frame of size 44\"x26\" M-10 fixed at site up to satisfactoin of Engr-in-Charge and including dismentling of old manhole cover slab complete all as specified. |
| 185 | S&F Providing FRC manhole covers with rectangular frame of size 22\"x28\" M-10 fixed at site up to satisfactoin of Engr-in-Charge and including dismentling of old manhole cover slab complete all as specified. |
| 186 | Galvanized, corrugated mild steel sheet 0.63mm thick with two corrugation side lap, fixed with L-type or J-Type or cranked hook bolt and washers as in wall claddings etc. with grade of Zinc coating 275, including dismantling of old unserviceable sheet complete all as specified & as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail