| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, sewage pipe line, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out from any type of soil, including cutting of roots of trees, weeds, bushes, or any type of obstacles like chain link fencing, etcwhille digging out forman holes pits , or digging for sewage pipe linetrenches etc complete all as specified and directed. |
| 2 | Returning,filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 3 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed acomplete all as specified and directed.complete all as specified and directed by Engr-in-Charge. |
| 4 | Removing excavated material exc. 500m but n exc. 1500 m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed. |
| 5 | Surface excavation and clearing vegitation n.exc 30cm deep & averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 6 | M&L Reinforced NP2 pipe of 150 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 7 | M&L Reinforced NP2 pipe of 150 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with set in cement mortar complete all as specified and directed. |
| 8 | M&L Reinforced NP2 pipe of 200 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 9 | M&L Reinforced NP2 pipe of 200 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 withset in cement mortar complete all as specified and directed. |
| 10 | M&L Reinforced NP2 pipe of 300 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 with and including demolition and breaking up existing drain pipes of any description ( like PVC, salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 11 | M&L Reinforced NP2 pipe of 300 mm dia laid in trenches and jointed on concrete bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 withset in cement mortar complete all as specified and directed. |
| 12 | Cuttingintoexistingmanhole removing existing drainmakinggood to wall and rendering cutting out branch channeland makinggood benchingfor 100mm dia pipe incement concrete 1:2:4 complete all as specified and directed. |
| 13 | Description all as per ser item No 12 above but for 150mm dia. |
| 14 | Description all as per ser item No 12 above but for 225mm dia. |
| 15 | M&L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricksand including demolition of brickwork built in cement mortarcomplete all as specified and directed. |
| 16 | M & L brick work with sub class \"B\" bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricksbuilt in cement mortarcomplete all as specified and directed. |
| 17 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement on brick/concrete/stone wall surfaces of any description, and finishing the surfaces even and fair complete all as specified and directed. |
| 18 | Demolition of reinforced cement concrete of any descritption and in any position not otherwise speccificallt provided for as directed by Engr-n-Charge. |
| 19 | M&L for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole cover slab and similar article with plain faces, set in cement 1:4 complete all as specified and directed. |
| 20 | S&F TMT Mild Steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 21 | Description all as per ser item No 20 above but for6 mm to 8 mm dia complete all as specified and directed. |
| 22 | M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for PCC 1:2:4type B1 (12.5mm graded aggregate ) asin coping with neru finishedincluding necessary form work complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F 75 in repair mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/floors with necessary MS clamps including taking down old pipes complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in repair 110 mm PVC (SWR) access door bends any radius including taking down old complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in repair 75 mm PVC (SWR) access door bends any radius including taking down old complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F in repair 110mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F in repair 75mm PVC (SWR) junction single,(Single T) equal or unequal provided with access door complete all as specified and directed by Engr-in-Charge. |
| 30 | S&F in repair 110mm PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, tank staging,for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed. |
| 32 | M&L Random rubble walling, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed |
| 33 | M&L for factory made 60 mm thick non skid pre-polished coloured interlocking paver block made with grey Cement and pigment not less than compresive strength 35 Kg/Cm (M-35) sqm laid over and including 25mm thick dry sand coushoining complete all as specified and directed by Engr-in-Charge. |
| 34 | Taking down chain link fencing,from existing angle iron post, and refixing the same place after digging of trenches, laying of pipe line , or any type of constructing work which are required on groundas per direction of Engr - in -Charge, complete all as specified and directed. |
| 35 | Dewatering of contaminated waste effluent from Man hole/septic tank/soakage well of any capacity and depth by vehicle mount sewage cleaning machine and jetting and disposal to low lying area upto distance of 5Km including taking off and re-fixing manholes covers etc complete all as specified and directed by Engr-in-Charge. |
| 36 | Cleaning of septic tank of any capacity and depth including inlet chamber, outlet chamber removing out all sludge, silt, residue waste material (organic/inorganic nature) by mount sewage cleaning machine and required manpower after plugging the incoming sewage line and depositing the waste upto 5Km distance and burring the same in suitable size of pit and covering the same with earth and removal of surplus soil all as specified and directed by Engr-in-Charge. |
| 37 | Cleaning /clearing and maintenance of sewage lines, manholes including CI/PVC stacks, gully traps, floor traps, under ground lines any depth by removing any type of blockage from drain / drain pipe upto and including 250mm dia by mechanical machine method / manually (using pipe cleaning machine with auger function standard or specialised / manually) from manholes and flushing with water with pressure using water hose pipe connected with water trolleys after cleaning including manholes, sludges/sludge effluent to be disposed off as directed by Engr-in-Charge including taking off manholes covers and re-fixing the same after cleaning of sewage lines/manholes cleared/cleaned.Under this item are to be maintained and kept fully functional by removing any type of blockage complete all as specified and directed. |
| 38 | Supply and install hi wall split units indoor/ outdoor complete with cordless remotecontrol unit and with cooling and heating function of capacity 1.5 Ton complete not less than 5 star ratingall as specified and as directed by Engr-In-Charge. |
| 39 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVAcomplete all as specified and as directed by Engr-In-Charge. |
| 40 | M&L for additional lenghth ofCopper pipe for installing split type air conditioner at site of suitable size /guage complete allas directed by Engineer in Charge.Note Additional quantity both suction and discharge pipe has cosidered as one RM) |
| 41 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVCconduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmmand one run of PVC conduit shall be measured as one unit. |
| 42 | Supply and fixingSingle pole and neutral enclosure with a two pin and earth plug and socketcomplete withone single pole MCB 20 Amp, 240 Volts complete all as specified and directed. |
| 43 | M & L for cutting the existing GI tube pipe for insertation of new Tee branches, reducers in any position of 15 mm dia pipe line complete all as specified and directed. |
| 44 | S&F Water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated competed all as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating. Make:- Bajaj/ Havells/CG |
| 45 | S&Fsheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed. Make:- Legrand/INDOASIAN or equivalent of L&T/ABB/Seimens/GE. |
| 46 | S&F steel tubes, \"medium grade\", galvanised, with all fitting; laid in trenches, fixing on wall complete of bore 15mm dia all as specified and directed. |
| 47 | S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as directed. Make: PARKO/MARC |
| 48 | S&F PVC Hot and Cold connection 15 mm size with PTMT nuts of length 300 mm. |
| 49 | S&F Fancy type 15mm dia Stop valves, cast copper alloy,screwed down,high pressure,with crutch orbutterfly handle,screwed bothends for iron pipe or for unions and fixed |
| 50 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid in concealedNew PVC conduit and conduit accessories complete all as specified and directed. |
| 51 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum |