| 1 | Design, Supply, erection, Testing and commissioning of passenger Machine room less lifts of capacity 680 Kgs(10 persons) for G+1 storeyed building with the following specifications:i) Speed : 1.0 MPS ii) Floors : 2 floors (GF+FF) iii) Travel: 10 mtrs (approx). iv) Stops & Openings 2 Stops & 2 Openings. v) Controller : Micro processor Based AC VVVF. vi) Automatic rescue device complete with dry maintenance free batteries as required.vii) Control system : Microprocessor Based Automatic push button/Simplex Selective Collective/duplex collective Control With / Without Attendentviii) Power:- 415V, 3-Phase, 50Hz, 4 wires system.ix) Machine Location/Type:- Machine RoomlesSx) Cabin and Door Material:-a) Car : Stainless Steel Honeycomb Hair line finsih scratch & Fire proof.b) Landing doors/frame/finish : Two Panel power Operated Centre opening Horizontal Power sliding StainlessSteel - Honeycomb-Hairline finish Scratch proof with fire rating-Aluminum Door sills.c) Type of Door Drive : Linear Door Drive System.d) Cabin Amitites:- Ventliation fans-Acrylic with Led Lights-Landing operating panel along the Back lit LOPButtons for both inside and outside-Orange Square Dot Matrix Scrolling Vertical Dispaly-SS Round Handrailfor 3 sides-Mirror On back side-Floor Annunciator-Granite Flooring-Indications of lift capacity and Do andDont\"s-Battery operated Emergency Bell & Light and ARD Annocument, Over load warning, Auto ON/Offfeature, Outside digital hall position indicator with bidirectional arrow.xi) LOP:- Landing Display in the wall along with floor indication of cabin-Stainless steel-Hairline Finish-Back litLOP Buttons both up and down- GONG-For all the floors.xii) Safety features:-One Fire man\"s switch per group of Lifts at Ground floor level. All Lifts to have firemanmode-3 way intercom press and speak phone, Over speed Governor, Over load protection and indication,Mechnical & Infra Red Door Screen for the Door sensor upto full door height, Battery Operated Emergency bellalarm & lightxiii) All safety precautions, lift numbering, and emergency contact information shall be provided on a permanent, non-removable basis inside the lift car and outside, as directed by the Engineer-in-Charge. The materials used shall be durable, tamper-proof, and suitable for long-term usage.Xiv) The OEM agency shall provide one year free comprehensive maintenance with the 12 monthly servicing and attend all types breakdowns without any additional cost. Perfered Makes:- Johnson/Otis/Schindler/Kone/Mitsubishi |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modularplate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single corecable etc. as required. Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 6 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 5 | Supplying and fixing 12 way , Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 9 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) body material 18- 22 watt and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OE warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 10 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required (salt=5kg, Charcoal=96Kg) |
| 11 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 12 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 13 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge-In cement mortar |
| 14 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet |
| 15 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 16 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 20 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) derived from natural sources. |
| 21 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm |
| 22 | Supplying and applying of Nitocote wall guard (fosrac brand) for External walls where the dampness is observed and instructed by Dept. including all materials, labour incidental and operational charges complete etc., for 2 coats on old external walls after applying one priming coat of Nitoprime AW (fosrac brand). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes and filling of cracks with Nitoseal PU50 as per the direction of Engineer-in-Charge. Procedure to be followed: 1) Surface Preparation: Surface shall be prepared by mechanical grinding to remove all loose mortar, laitance, oil, grease, decayed matter and algae growth.2) Filling of Cracks: Identify cracks on the walls and then chasing them open in the form of “V” groove (Cutting of the crack shall be done of size 10 mm x 10 mm) and Fill the “V “groove with NITOSEAL PU50 properly.3) Priming coat: The prepared surface shall be applied one coat of acrylic primer, Nitoprime AW prior to the application of Nitocote wallgaurd, prime coat should be air cured for 6 hours. 4) Wall gaurd application: Nitocote wall gaurd (Fosroc brand) at a thickness of 110 microns DFT each coat, in two coats. Each coat must be air cured for 6 hours. (GST applied as per DSR-21) Note: The above work has to be done with the help of trained and skilled labour. |
| 23 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 24 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |