| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift up to 1.5 m, as directed by Engineer-in-Charge: |
| 2 | All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | a)1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | b) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 7 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 9 | a)First Class Countrywood |
| 10 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) |
| 11 | First Class wood 35 mm thick shutters |
| 12 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 13 | a)First class country wood. |
| 14 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 15 | First Class Country wooda)30 mm thick |
| 16 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 17 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 18 | 300x16 mm |
| 19 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : . |
| 20 | a)300x10 mm |
| 21 | b) 100x10 mm |
| 22 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 23 | a)125 mm |
| 24 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. |
| 25 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. |
| 26 | a)30 mm thick plain PVC door shutters. |
| 27 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 28 | 12 mm cement plaster of mix : |
| 29 | 1:6 (1 cement: 6 fine sand) |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 31 | Two or more coats on new work. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 33 | One or more coats on old work. |
| 34 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : |
| 35 | Old work (one or more coats applied @ 0.83 ltr/10 sqm). . |
| 36 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 37 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 38 | The waterproofing work for the existing roofs shall be carried out as detailed below: (a)The roof area , parapets etc is thoroughly cleaned and surface area shall befree from dust, loose particles, oil, grease, or any other contaminants etc.(b)Applyingthe first coat as a primer, prepared by mixing Brushbond Roof Guard high build fibre reinforced acrylic water proofing coatings for existing roofsor equivalent with clean water in the ratio of 1:1. The primer shall be applied uniformly over the prepared surface. (C) After the priming coat has completely dried, apply the second coat of Brushbond Roof Guard or equivalent directly on the surface as the finishing waterproofing coat.The entire application shall be carried out strictly in accordance with the manufacturer’s specifications and instructions and as per the direction of Engineer in Charge.. |
| 39 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 40 | a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 41 | b) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 42 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 43 | Kitchen sink with drain board510x1040 mm bowl depth 250 mm. |
| 44 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 45 | Providing and fixing PVC , low level flushingcistern with manually controlled device (Handle lever ) conforming to IS 7231 with all fittings and fixtures complete. |
| 46 | 10 litre (full flush) capacity-white |
| 47 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 48 | Flexible pipe 32 mm dia |
| 49 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 50 | Rectangular shape 453x357mm |
| 51 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 52 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 53 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 54 | 15 mm nominal bore. |
| 55 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 56 | 15mm nominal bore |
| 57 | Providing and fixing PTMT grating of approved quality and colour. Circular type. |
| 58 | 100 mm nominal dia. |
| 59 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 60 | 100 mm diameter |
| 61 | Removingcompletely all plants/saplings with roots growing on buildingsideat all levels,spouts,khurras,canopy chajjas roof area including application of herbicide to prevent the regrowth etc including disposal of rubbish to the dumpimg ground within a distance of 50m |
| 62 | Taking out existing wooden/pvc door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 63 | Taking out existing wooden window/ventilator shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 64 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 65 | PVC Floor trap 100x75mm |
| 66 | Providing and fixing PVCpipes ofpressure class of 10 kg/Sq.cm completefittings and clamps including cutting and making good the walls etc complete( Internal work ) (a) 20mm outer dia |
| 67 | (b)25mm outer dia |
| 68 | (C)32mm outer dia |
| 69 | Providing and fixing UPVC plastic ball valve of approved brand andquality etc complete as per the direction ofEngineer in Charge. |
| 70 | 20 mm nominal bore |
| 71 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 72 | 30 cm length 15 mm nominal bore |
| 73 | Providing and fixing pvc water tank covers tothe existing pvc water tank afterremoving the damaged covers etc complete as per the direction of Engineer in charge. |
| 74 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 75 | Of area 3 sq. metres and below |
| 76 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: |
| 77 | Of area 3 sq. metres and below |
| 78 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 79 | Credit for takingpossession and disposal of unservicable materials |
| 80 | a) Door shutters with frames |