Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Mannual rescue and operation rescue of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants of various capacity pumps, sumps, over head reservior, service tankswith a well trained and experienced operator/technician (01 No/Shift) for 02 shifts, depending availability of water from BMC, includingSundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : Tanaji pump house,The details of operation of water supply installations comprising the following items/machinery/fittings:-(i)Operating Mono block centrifugal Pumping set of capacity 7.5 HP - 02 Sets(ii) OperatingChemical dozing system - 01 set (a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets for running of the pump to be maintained.(d)Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge.(e)Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing.(g)The contractor shall be responsible to keep the water supply installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue.(j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head.(ii)Valve man - @ Rs 1800/- per operation shift per head. |
| 2 | Mannual rescue and operation rescue of water supply installation with all connected equipments, supply lines,Machineries and electric driven pump set of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced operator/technician (01 No/Shift) for 03 shifts,depending availability of water from BMC, includingSundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : NAD Firefighting Pump HouseThe details of operation of water supply installations comprising the following items/machinery/fittings:-(i)Operating main electric fire Pumping set of capacity 75 HP - 02 Sets(ii)Operating Jockey fire Pumping set of capacity 15 HP - 01 Sets (a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets for running of the pump to be maintained.(d)Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge.(e)Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing.(g)The contractor shall be responsible to keep the water supply installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue.(j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head.(ii)Valve man - @ Rs 1800/- per operation shift per head. |
| 3 | Mannual rescue and operation rescue of water distribution sluice valves and firefighting sluice valves of various sizes installed at GE(NW) Mankhurd area for employingvalve men on all days including Sunday & Holidays as directed by Engineer-in-Charge for the following locations and shifts:-a) NAD(T)area forfire fighting and water distribution valves - 01 Shift(a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets for running of the pump to be maintained.(d)Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge.(e)Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing.(g)The contractor shall be responsible to keep the water supply installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue.(j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head.(ii)Valve man - @ Rs 1800/- per operation shift per head. |
| 4 | Manual rescue and operation rescue of Electric supply installations round the clock inthree shifts including Sunday & holiday by employing one skilled Electrician (having knowledge of HT VCB, HT OCB, Transformers, APFC & LT Panels) in each shift at Main Receiving Station at NAD including operating HT & LT panels, carrying out break down maintenance in transformer, HT,LT Panels cables etc, daily cleaning and upkeep of surrounding area of installation and Maintaning record of daily Break Down & maintenace, Monitoring & Recording of parameters such as Voltage, Current, PF etc Powerfactor atNAD Depot (Trombay) andNaval Dett (Kalyan/ Ambernath) all as specified and as directed by Engineer-in-Charge. Note :-(a) All the T&P required for the Manual rescue & Operation rescue of installations shall be provided by the contractor and cost of the same is inclusive of quoted rate(b) Materials required for upkeep of installations such asrooms, dusty cloth for cleaning of plants, buckets, etc shall bealways available at the installations for use and shall be deemed to be included in the quoted rates. (c) The Contractor should prepare duty chart on monthly basis and shall be got approved by Engineer-in-Charge. (d) Attendance register shall be submitted to Engineer-in-Charge on Daily basis.(e) Skilled electrician shall have ITI certificate and 5 Year experiance certifcate in HT maintenace. (f) The Contractor shall submit bio-data of the technician and experience on handling HT equipments.The individual will not be permitted to perform duty, if found unfit. (g) In case any operator is missing or absent from duty, a penalty of Rs 2000/- per technician shall be recovered from contrcator and Engineer-in-Charge decision shall be final and binding on this account.(h) Each shift duration shall be 08 Hrs timing as required at the discreation of Engineer-in-Charge, details of shift are as under :-Shifts : 1st shift : 0600 to 1400 hrs, 2nd shift : 1400 to 2000 hrs, 3rd shift : 2000 to 0600 hrs (i)Electrician-@ Rs 2000/- per operation shift per head(ii)Helper - @ Rs 1800/- per operation shift per head.(i) Contribution towards bonus EPF, ESIC the amount is payble only after submission of valid and authentic document in support of having paid the requisite amount to the employed labour. |
| 5 | Mannual rescue and operation rescue of water distribution sluice valves of various sizes etc with one valveman per shift, operation for 01 shifts/per day, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge.Location: 31 WEU Thane(a) Pumping set centrifugal type of capacity 12 litres/sec with 38 m head with electrically driven induction motor 15HP, 3 phase- 02 No. (b) Chemical dozing plant with injection assembly booster pump with induction motor of 1.5HP, 3 phase - 01 No. (c) Vertical type pressure filter of capacity 1000 glns/hr including blower unit with induction motor 5HP, 3 phase - 01No (d) LT electric control panel with all accessories and components - 02 Nos |
| 6 | Mannual Rescue and Operation Rescue for following installations,with all connected equipments and machinaries as detailed here in under with one operator/mechanic,operation in 03 Shifts,including sundays and holidays including routine maintenance checks,tests etc. and upkeeping the installation complete all as specified and directed. Location :- NCN Thane . (i) ist shift-0600 to 1400 hrs (ii) 1400 Hrs to 2200 Hrs (iii) 2200 to 0600 hrs The details of operation of installations comprising the following items/Machinery/Fittings:- (i) Operating DG Set 600 KVA-02 Nos (ii) Operating AC Plant of NCN - 01 Nos (iii) -Fire Fightining Pump - 01 NosNote : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account.(b)The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy.(c) Contractor shall provide uniform and necessary tools required by the men employed by him.(d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose.(e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge. |
| 7 | Manual rescue and operation rescue of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants of various capacity pumps, sumps, over head reservior, service tankswith a well trained and experienced operator/technician (01 No/Shift) for 02 shifts, depending availability of water from BMC, includingSundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : SPDC pump house,The details of operation of water supply installations comprising the following items/machinery/fittings:-(i)Operating Mono block centrifugal Pumping set of capacity 40 HP - 02 Sets(ii)Operating Mono block centrifugal Pumping set of capacity 25 HP - 03 Sets(iii)Operating Mono block Pumping set of capacity 5 HP - 02 Sets(iv) Operating DG set 75 KVA - 01 No(v) OperatingChemical dozing system - 01 set (a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets for running of the pump house & plants to be maintained.(d)Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge.(e)Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing.(g)The contractor shall be responsible to keep the water supply installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head.(ii)Valve man - @ Rs 1800/- per operation shift per head. |
| 8 | Manual rescue and operation rescue of Swimming Pool, consisting of following equipments & Electrical Panel boards etc. by employing one FGM (Skilled) Per Shift of 8 hrs for 2 Shifts, 16 Hrs per day, including Sundays & Holidays, Comprising the following works :- (a) Operating Pump sets of any capacity as directed (b)Checking water level in the Swimming Pool. (c) Operating Chlorination/Ionization Plants as directed (d) Maintaining Log Book for Swimming Pool (e) Maintaining record of timing of Swimming Pool operation (f) Operating Sluice/Gate Valvesfor Supply of water to pool as per the time schedule/requirement. (g) Routine maintenance & cleaning/back washing of filteration plant.(Note : Disinfectant chemicals and other consumable chemicals required for Operation and maintenace of Swimming Pool will be measured and paid separately under relevent item of the schedule)A.EQUIPMENTS :(a) (i)Starter Panel - 01 No (b)Vertical type pressure filter capacity 30000 gallons/ hour- 02 Nos (c) Pump set capacity 20HP - 03 Nos (d)Suction sweeper complete with Accessories and suction hose along with 2 HP pump set - 01 No.(e) Connecting Valves of various type/sizes. (a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets for running of the pump house & plants to be maintained.(d)Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge.(e)Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing.(g)The contractor shall be responsible to keep the water supply installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head.(ii)Valve man - @ Rs 1800/- per operation shift per head. |
| 9 | Manual rescue and operation rescue of water distribution sluice valves of various sizes installed at GE(NW) Mankhurd area for employingvalve men on all days including Sunday & Holidays as directed by Engineer-in-Charge for the following locations and shifts:-a) SPDC area forwater distribution. - 01Shift(a)Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractorfrom his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account.(b) Installation shall be manned including Saturdays, Sunday & Holiday.(c)Proper log sheets for running of the pump house & plants to be maintained.(d)Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge.(e)Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f)Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing.(g)The contractor shall be responsible to keep the water supply installation neat and clean on every day.(h)All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :-(i)Operator- @ Rs 2000 per operation shift per head.(ii)Valve man - @ Rs 1800/- per operation shift per head. |
| 10 | M&L for repair of angle iron, U shape channel of any size as per site requirement, welding to required shape, including all nuts,bolts,washers etc complete all as specified and directed by engineer-in-charge. |
| 11 | Supply only bleaching powder for treatment of water and other purposes etc complete all as specified and directed. |
| 12 | Supply& fixing in repairs of Chequered plate Fe 410-W(Gde-E- 250)A quality- for cable trenches, ladders including equal angle trench frames, including cutting as per requirement of site, square cut or notched (ordinary and counter sunk) forming holes, without any including providing handles |
| 13 | Supply& fixing in repairs for mild steel work confirming to Fe-290, GdeE-165 in stairs/ladders including stringes, treades, landing, balusters, hand rails etc including applying two coat of paint over one coat of red oxide complete all as specified and directed. |
| 14 | Fabricate supply and fix valve chamber covers made out of suitable size MS angle/MS plate/flat/rod,hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed. |
| 15 | M&L for rewinding of electric motor 40 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc.(b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing onload. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA.(e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer. |
| 16 | M&L for rewinding of electric motor 25 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc.(b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing onload. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA.(e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer. |
| 17 | All as per Item No 16 For Motor 20 HP Cap |
| 18 | All as per Item No 16 For Motor 15 HP Cap |
| 19 | All as per Item No 16 For Motor 10 HP Cap |
| 20 | All as per item No 16 for Motor 7.5/5 HP capNOTE: Quoted rates shall be deemed to include one year warranty formotors after rewinding and commissioning. |
| 21 | Taking out old unserviceable selector switch of Voltmeter and supply and fix new Selector swith of rating 16Ahavingposition for measurement of\"Voltage between Phases with Off\"including all required wiring and connections complete including testing till found satisfactory all as spedified and as directed. (Make-L&T, Cat pat No-61312 SAB13TDYR) or equivalent. |
| 22 | S & F of Amp meter digital type 0 - 200 amps capacity with suitable type ratio CT size as per existing including taking down the exsting and remove complete all as specified and as directed.Make :- C&S / schneider / AEI / L&T |
| 23 | S & F volt meter digital type 0 - 500 volt including taking down the existing and remove complete all as specified and as directed. Make :- C&S / schneider / AEI / L&T |
| 24 | M & L for preparation of old painted /unpainted surfaces of any description,including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete all as specified and as directed by Engineer-In-Charge for the following sizes of sluice valves. |
| 25 | Sluice valve of 80 mm size complete |
| 26 | Sluice valve of 100 mm size complete |
| 27 | Sluice valve of 150 mm size complete |
| 28 | Sluice valve of 200 mm size complete |
| 29 | M & L for preparation of old painted / unpainted surfaces of any description,including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-In-Charge for the following capacity of electric motor. |
| 30 | (a) Electric motor pump set upto 40 HP capacity |
| 31 | (b) Electric motor pump set upto 15 HP capacity |
| 32 | (c) Electric motor pump set upto 10 HP capacity |
| 33 | (d) Electric motor pump set upto 7.5 HP capacity |
| 34 | Material and labour for preparingold painted steel pipe surface such as Rising pipe (Red), Delivery pipe (Blue), Overflow pipe washout pipe (Yellow) etc and applying one coat of synthetic enamel paint for 100 mm bore GI pipe complete all as specified and as directed. |
| 35 | All as per item No. 22 above but 80 mm bore GI pipe. |
| 36 | M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification. |
| 37 | S&F GI strip size 32 x 6 mmall as directed including welding brazing and taking down of old copper strips as required at site |
| 38 | Supply and fix in replacement ladder height 10 feet max, steps on every 01 feet made of angle iron of size 50x65x5 mm thickfor sump including taking down old rusted iron ladder complete all as specified and directed. |
| 39 | Supply and Fixing industrial type pressure gauge made out of SS 304 material, SS sipon shall be factory insulated with closed cell elastomeric insulation in tubing form, pressure gauses shall be factory fitted with a ball valve complete, all as specified and directed. |
| 40 | Supply only Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containerscomplete all as specified and as directed.Make:-1.Aqufit manufactured by Sree Rayalaseema Hi strength Hypo Ltd.2. Puri chlor manufactured by Sree Rayalaseema Hi strength Hypo Ltd. / M/s Ravi Enterprises / M/s Potter & Watts (Traditional products). Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. |
| 41 | Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating,Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system |
| 42 | All as per item No 36 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32 & Cat no - CS94111 of L & T or equivalent from Schnider Electric, ABB/ C&S |
| 43 | All as per item No 36 above but Contactor Three Pole 415 volts40Amps AC 3 RatingConforming to Type- MNX - 40 & Cat no - CS94190of L & T or equivalent from Schnider Electric/ABB/ C&S |
| 44 | All as per item No 36 above but Contactor Three Pole 415 volts50 Amps AC 3 Rating Conforming to Type-MNX - 50 & Cat noCS-97075of L & T or equivalent from Schnider Electric/ABB/ C&S |
| 45 | All as per item No 36 above but Contactor Three Pole 415 volts70 Amps AC 3 Rating Conforming to Type- MNX - 70 & Cat no - CS-97076of L & T or equivalent from Schnider Electric/ABB/ C&S |
| 46 | Supply only DECPAC-P (Aluminium based caogulant) packing in 25 kg plastic bags complete. |
| 47 | Supply and lay in repairs/ replacement XLPE 3.5 Core 25 Sqmminsulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of following sizes laid in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge. |
| 48 | Supply and lay in repairs/ replacement XLPE 3.5 Core 35 Sqmminsulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of following sizes laid in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge. |
| 49 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable all as specified and directed by the engineer-in-charge. |
| 50 | Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms all as specified and directed by the engineer-in-charge. |
| 51 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point all as specified and directed by the engineer-in-charge. |
| 52 | M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC. |
| 53 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.. |
| 54 | S& F in repair ofFuel level assembly complete all as specified and directed by Engineer-In-Charge. |
| 55 | M & L for servicing of Air compressor machine complete all as specified and directed by Engineer-In-Charge. |
| 56 | M&L for scraping/cleaning surface of pipe lines of size 40mm to 150mm size and preparation of entire surface and applying one coat of Synthetic enamel paint epoxy coated ( Sea green colour for suction and discharge pipe lines) including writing, markingin stencil all as directed. |
| 57 | M&L for scraping/cleaning surface of pumpset, and preparation of entire surface and applying two coat of Synthetic enamel paint epoxy coated ( grey colour and red colour for fan cowl)all as directed. |
| 58 | Supply and fixing Air filter compressor assembly complete in repair including taking down old u/s Air filter as per sample size all as directed by Engineer-In-Charge. |
| 59 | M & L for carrying out \"B\" check of 600 KVA DG Set including of \"B\" check kit consisting of the following under laid complete all as specified and as directed by the Engineer-In-Charge.(i) S & F Primary Fuel Filter - 01 Set(ii) S & F Secondary Fuel Filter - 01 Set(iii) S & FOil Filter - 01 No.(iv) Complete cleaning of DG Set(v) Examination and rectification of engine RPM(vi) Monitoring of output and maintaining and adjusting speed governor(vii)Engine oil as required shall be measured and paid separately). |
| 60 | -Ditto all as per item No 46 above but 320 KVA DG Set. |
| 61 | -Ditto all as per item No 46 above but 250 KVA DG Set. |
| 62 | -Ditto all as per item No 46 above but 200 KVA DG Set. |
| 63 | M & L for servicingtoAMFpanelof DG sets of any capaityincludingroutine/ preventive maintenance checksfor trouble free functioningas directed.Note :The rate Quoted deemed to be included all the minor spares such as screws, washers, clips., battery terminals and other spares will be measured and paid seperately under supply only items. |
| 64 | Supply only distilled water in sealed bottles of 1 litre capacity complete all as specifed. |
| 65 | Supply oly diesel exhaust fluid fcomplete all as specified and directed |
| 66 | Supply only multi-grade 20 W 40 engine oil for topping upto required levels complete all as specified and as directed by the Engineer-In-Charge. |
| 67 | Supply only coolent for engines for topping up to required levels complete all as specified and as directed by the Engineer-In-Charge. |
| 68 | M & L for dismantling fuel tank ofDG Set and draining out fuel in tank, cleaning the tank using pressure jet process, de-scaling the tank completely and refixing the tank in original position and refilling the tank with fuel retrieved on duly calibrating the same through authorised agencies of the manufacture (of DG Sets) complete all as specified and directed by the engineer - in - charge. |
| 69 | Supply and fixing in repairs fan belts including replacement of u/s fan belts for 125 to 320KVA DG Set as per sample size all as directed. |
| 70 | Supply and fixing in repairs Residential Silencer including replacement of U/S Silencer for 250 KVA DG Set as per sample size all as directed. |
| 71 | S&F in repairsrelay 12 V DC. suitable for existing AMF panel of suitable capacity. |
| 72 | Supply and fix in replacement battery heavy duty 12 Volts 180 AHmaintenance free including taking down old u/s complete. |
| 73 | Supply and fix in replacement battery heavy duty 12 Volts 130 AHmaintenance free including taking down old u/s complete. |
| 74 | Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSUREin open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd |
| 75 | Supply and Fix in repairs Change Over FP 400 Amps 415 Volt IN SHEET STEEL ENCLOSUREin open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd |
| 76 | Supply and fix in repairs Fuel Injector Calibration for Fuel pump DG Set of any capacity complete all as specifed and as directed by the Engineer-In-Charge. |
| 77 | Supply and fix in repairs Power Capacitors of Rating 25 KVAR 415 Voltin repairs Naturally air cooled Double dielectric heavy duty, MPP type440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified. |
| 78 | All as per item No 31 above but Power Capacitors of Rating 20 KVAR 415 Volt |
| 79 | All as per item No 31 above but Power Capacitors of Rating 15 KVAR 415 Volt |
| 80 | All as per item No 31 above but Power Capacitors of Rating 10 KVAR 415 Volt |
| 81 | All as per item No 31 above but Power Capacitors of Rating 7.5 KVAR 415 Volt |
| 82 | All as per item No 31 above but Power Capacitors of Rating 5 KVAR 415 Volt |
| 83 | All as per item No 31 above but Power Capacitors of Rating 2 KVAR 415 Volt |
| 84 | Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw,display. |
| 85 | M & Lfor testing of APFC panel for proper functioning in manual & auto mode, including re-wiring theburnt outwires, replacing the wiring ducts/casing Capping, fuse units and cleaningand testing complete all as specified and directed. |
| 86 | Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system |
| 87 | All as per item No 40 above but Contactor Three Pole 415 volts40Amps AC 3 RatingConforming to Type- MNX - 40 & Cat no - CS94190of L & T or equivalent. |
| 88 | All as per item No 40 above but Contactor Three Pole 415 volts70 Amps AC 3 Rating Conforming to Type- MNX - 70 & Cat no - ST19002of L & T or equivalent. |
| 89 | M & L for dismantling carefullly fly wheel ring of 250 KVA DG Set and supply and fix new wheel ring to match the grooves of starter of existing model complete and testig for satisfactorily functioning. |
| 90 | M & L for dismantling carefullly fly wheel ring of 200 KVA DG Set and supply and fix new wheel ring to match the grooves of starter of existing model complete and testig for satisfactorily functioning. |
| 91 | S & F in replacement solenoid switch for control of fuel governor, operation in 12 Volts DC supply as per existing model fixed complete all as specified and as directed by the Engineer-In-Charge. |
| 92 | M & L for servicing Fuel injection pump of 200/ 250 KVA DG Set by striping off complete and cleaning each part in volatile liquid cleaner / petrol removing scales, cleaning, injector, spray nozzle including replacement of wornout parts such as injector heads including re-calibration from authorised service centre for smooth functioning etc. including testing and refixing in the same position all as specified and as directed by Engineer-In-Charge. |
| 93 | M&L for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant,carring out pressure test and rectifying leakage by brezing/soldering test and reinstalling including filling fresh coolant (approx 60 ltrs) all as directed and specified for 250 Kva DG set |
| 94 | M&L for dismantling existing unserviceable exhaust pipe of 200KVA/ 320KVA/ /250 KVA DG set and supply and fix new exhaust pipe of exiting model complete including lapping asbestos rope making good all disturbed surface area to match the surrounding |
| 95 | S & F in repair to Generator controller panel display meter for 200 KVA DG Set as per existing make all as directed. |
| 96 | S&F Battery Charger 230 V, AC Input and 24 Volt DC out put suitable for AMF panelas per exising make complete all as specified and directed by Engineer-In-Charge. |
| 97 | S & F in replacement of Power contactor current rating 200Afixed complete all as specified and as directed by the Engineer-In-Charge. |
| 98 | M&L for Spray painting of canopy of DG set of size from 200 to 315 KVAfrom outside with good quality enamel paint including cleaning with suitable cleaning agent, rubbing with emery paper, finishing, filling with putty for smoothnesscomplete all as specified and directed. |
| 99 | Supply and Fix in repairs 230 volt Selector Switch 3 Positionsuitable forLT panels including taking down old u/s complete. |
| 100 | S & F in repairs 230 Volts indication lamp complete(R Y B ) for mounting on LT panel including taking down old u/s complete. |
| 101 | M & L spray painting inside, outside complete tothe LT panel boards outdoor type of size not exceeding 2.0 Mtrwidth 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface. |
| 102 | M& L in repairs for fabricating of diesel tank from MS steel sheet of 6mm thick complete all for starage of 400 Ltrs of diesel with redoxide paint and 2 coats of synthetic enamel paint complete all as specified and directed. |
| 103 | M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long(100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications completeall as directed by Engineer-in-Charge.(a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 micronsFast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm,External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms,Recommended for normal soil conditions. Conforms to IS : 3043 – 1987.(c)Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge.(d)Including Taking down of existing earthing. |
| 104 | Supply & Fix copper stripof size 20 X 3 mm duly covered,fixed on porcelain insulators along the wall / roof / ceiling etc complete all as directed.Note : (i)Cost of Porcelain insulators and screw shall be of non-corrosive type and cost is deemed to be included in the quoted rate of the job. (ii) Gap for fixing of support insulator shall not be more than 35cm from one onother. |
| 105 | Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containerscomplete all as specified and as directed.Brands having pan india availability, acceptability& being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed. |
| 106 | Material and labour for taking out unserviceable burnt out electric monoblock/centrifugal motor with pump from the foundation of pump capacity 15 HP, 440 Volts, 50 Hz by opening/diconnecting all mechanical and electrical connection and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the sloths of stator including replacement of minor accessories like mica paper, sleeves, glass fibre, bamboo pieces etc inlcuding varnishing/heating at heat chamber suitably and opening the monoblock pump assy for replacement of unserviceable parts maintaince and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitabley including making the electrical and pipe connection including testing to get satisfactory result complete all as specified and as directed.Note: (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as \"supply only. |
| 107 | M&L for draining out Water,throughly cleaning and removing accumulated sludge,dirt and scale from the bottom,walls,ceiling and mouths of circulating pipes of service tanks/PVC tanks of capacity upto 500 lires located on rooftops of building The work includes disinfection of tanks using bleaching powder to ensure that they are bacteria free, removal of all previously written dates from the tank surface and depositing the removed waste to low lying area under deffence land as directed,After cleaning the date of cleaning shall be stenciled in white synthetic enamel paint on a black background,in 100mm high letters in the format \"CLEANED ON DATE- CLEANED DUE DATE-\"complete all as specified and directed. |
| 108 | Ditto all as per item mentioned above but tank capacity from 500-1000 Ltrs |
| 109 | Ditto all as per item mentioned above but tank capacity from 1000-2000 Ltrs |
| 110 | Ditto all as per item mentioned above but tank capacity from 2000-3000 Ltrs |
| 111 | M&L for chemical potability test for water before and after cleaning / desiliting waterby authorised chemical laboratory ,BMC approved. Test result to be submitted in duplicate all as specified and directed |
| 112 | M & L in replacement of PVC Service Water Tank including tank nipple, bends, sockets complete all fitting required at site all including taking down the existing tanks as specified and directed by Engineer-in-Charge of 500 Ltrs capacity. |
| 113 | -Ditto- all as per item No 87 above but 1000 Ltrs capacity. |
| 114 | -Ditto- all as per item No 87 above but 2000 Ltrs capacity. |
| 115 | Supplying, laying, connecting and testing of GI tubing med gde of 25 mm dia with and including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions,etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge. |
| 116 | -Ditto- all as per item No 88 above but 40 mm dia. |
| 117 | -Ditto- all as per item No 88 above but 50 mm dia. |
| 118 | -Ditto- all as per item No 88 above but 80 mm dia. |
| 119 | -Ditto- all as per item No 88 above but 100 mm dia. |
| 120 | Taking down the existing silencer system, suitable modification to the canopy for installation of Retrofit Emission Control Device. Supply, Fixing, testing and commissioning suitable Retro Fitment for Emission Control Device in Diesel Generator of capacity 250 KVA/ 200 KW. The Retrofit Emission Control Device must have approved CPCB for family of DG sets & Required COP DG safety Alarm system included Material Construction -S5304 Temperature Indication and monitoning Pressure Indication and monitoring PM Capture/PM reduction capacity 85-90% High Heat Resistance Easy to InstallMaintenance twice a yearly with back purge for One year. Make/ Manufacturer Platino Automotive Pvt. Ltd/Inventive Gas Equipment or PI Green Innovations Pvt. Ltd. Note- (1) Approval: Device Should be type Approved CPCB for family of DG sets should be as per CPCB instructionsand same has to be obtained from one of the five currently Central Pollution Control Board and required OEM authorization Certificate, (ii) Application: Device capable to reduce particular matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from the Diesel Engine Technology/Type: ESP (Electro Static Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency(Min) Guaranteed specified Particulate matter (PM 2.5). ii) Carbon Monoxide, Hydrocarbon reduction efficiency Retrofit device is to be installed in place of the existing silencer, soot is to be collected in the Retrofit Device.(iv) The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap. A manual valve be given after the first stage (Oxidation stage) and before the second stage (Passive Regeneration Trap) of the DOFF, Noise attenuation is with in the permissible limits, Equipped with mechanical pressure relief system, capturing chamber made of resistance process, treated mild steel etc. as required (v) The RECD device provided by the seller should be equipped with a remote Data Monitoring system certified by ICAT/ ARAI providing essential information recorded at every 15 minutes, including but not limited to:a. Energy consumption. b. Running Hours. c. waming related to ECD diagnosis for the following conditions *Coplete loss of particulatecapture function.Removal of the ECD system,*Failure of ECD system.*Detection of exhaust bypass, temporary or permanent, as part of field/operator tampering.a. Installation of Emission control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Emission Control Retrofit Device includes any type of mechining. Tools & Plants and materials required. b. Construction of suitable earthing station(if applicable) and necessary connections shall be done by the seller. Warranty/Service: 12 Months number of preventive maintenancevisits offered in a year during warranty period:- 2 visits (vii) The Device to be minimum 10-12 year guarantee from date of commissioning. The guarantee certificate to be submitted to Engr-in-charge after commissioning the equipments.DELIVERABLES, TIME SCHEDULE Submission of approval of work/methodology, Drawings and the details of team as per the scope of work:-30 days, Delivery of Device:- 60 days.Installation, Testing commissioning at site of retrofit emission control device on existing DGSets:-90 days. (ix) Factory visit of device by Engineer in charge for approval is required before installation which is to be catered by contractor. |
| 121 | M & L for valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including dosmantling the existing valve chambercomplete all as specified and directed by EIC. |
| 122 | Supply and fixing of cast iron flanged ends sluice valve suitable for 100 mm dia pipes conforming to IS - Class PN - 1.0 with MS nuts, bolts, washers etc, as approved including taking out/ dismantling old unserviceable one and testing complete all as specified and as directed.Make :- KIRLOSKAR/KARTAR/ LEADER/ |
| 123 | Maint/Cleaning ofSub stationsinside and out side area andremoving of creepers raised along with sub station including surface dressing around the sub station not less then 3 mtrfrom out side fencing and removing the all waste material from site and Chemical spray inside and out side area of Sub station.Note:- T & P will bearreanged by contractor |
| 124 | S & F in repairs float ball valve assembly 20 mm bore , high pressure grade, with polythene float, fly nuts, screwed to GI pipe or brass ferrule, CI fittings viz. nipples, check nuts, reducers, elbow, sockets, etc. fixed complete all as specified and as directed by the Engineer-in-charge for the following bores of pipes: |
| 125 | -Ditto- all as per item No 93 above but 25 mm bore |
| 126 | -Ditto- all as per item No 93 above but 40 mm bore |
| 127 | M & L in replacement of run lead joint forCI Spigotand socket 80 mm bore pipes and fittingscomplete. |
| 128 | -Ditto- all as per item No 94 above but 100 mm dia. |
| 129 | M & L in replacement of rubber gasket joint of the size 80 mm size for CI flanged type pipe including nut, bolt, washer complete all as specified and directed . |
| 130 | -Ditto- all as per item No 95 above but 100 mm dia. |
| 131 | S & F in repairs Gun metal gate or globe valve 40 mm dia, confirming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and any addition / alteration required for threading and fixing complete all as specified and as directed by the Engineer-In-Charge of the following diameters: |
| 132 | -Ditto- all as per item No 96.01 above but 25 mm dia. |
| 133 | S&F cast iron covers, circular, for overhead PVC / RCC water storage tanks of any size, with MS strip / flat iron framework, with all necessary fixing and locking arrangements, nuts, bolts, washers, all as per BMC standards, with a shop coat of primer, including all necessary scaffolding / staging as required to cater at heights, taking out and disposing off old PVC covers, making any required addition / alteration to the tank for fixing of new CI covers, etc. complete all as specified, as directed by the Engineer-in-charge. (weight of tank cover not less than 10 KG). Make : As per sample |
| 134 | M&L for removal, workshop repair/overhaul, and reinstallation of electric monoblock/centrifugal pump sets (40 HP, 440 V, 50 Hz) including disconnection of all mechanical and electrical connections, transporting to workshop, stator rewinding with approved super-enamelled copper wire, replacement of minor motor accessories (mica paper, sleeves, glass fibre, bamboo wedges, etc.), varnishing/heat treatment, complete pump assembly servicing, bearing replacement (DE/NDE), nuts, bolts, gaskets, keys, gland/stuffing box, rubber bush, regreasing, reassembly, realignment, reinstatement at original location, electrical and pipe reconnections, and testing for satisfactory operation, all as specified and directed, including all costs for labour, materials, tools, consumables, transportation, and required spare parts (bearings, shafts, impellers, bushes, etc.) included in the quoted rate. |
| 135 | All as per item No 98 above but Pump set 25 HP |
| 136 | All as per item No 98 above but Pump set 20 HP |
| 137 | All as per item No 98 above but Pump set 15 HP |
| 138 | All as per item No 98 above but Pump set 10 HP |
| 139 | All as per item No 98 above but Pump set 05 to 7.5HP |
| 140 | Supply and fix gunmetal impeller and high-strength steel pump shaft for 40 HP centrifugal pump set, including removal of old impeller and shaft (if applicable), alignment, balancing, coupling, and necessary fittings. Work shall include inspection, testing, and commissioning to ensure smooth and efficient operation, as directed by the Engineer-in-Charge. Note: All tools, fixtures, and incidental materials required for proper installation shall be included in the quoted rate. |
| 141 | All as per item No 99 above but For motor 25 HP Capacity |
| 142 | All as per item No 99 above but For motor 10 HP Capacity |
| 143 | M&L for repair/serviceing /overhauling of following Submersible pump of capacity upto 05 HP set by replacing bushes , impeller thrust bearings, strainer of existing size, nuts and bolts, washers, pump shaft remetalling, grinding, polishing,greasing complete reassembling the pump and testing, complete all as directed. |
| 144 | All as per item No 100 above but Submersible pump of capacity upto 7.5/10 HP. |
| 145 | Rewinding of submersible pump set motor by dismantling the pump from the motor taking it to workshop, rewinding the motor with same size of copper enameled winding wire, insulating, varnishing of the same replacement of of bushes and any other spare parts required for smooth functioning of the submersible pump, re-assembling, re-installing at site connecting complete of the Submersible pump of capacity upto 05/7.5 HP |
| 146 | All as per item No 101 above but Submersible pump of capacity of 10 HP |
| 147 | Supply & Fix in repair fully automatic star delta starter suitable for 25 HP, 440 volt, 3 Ph Elect Motor with Single Phase Protection feature conforming to IS -13947 after taking down old unserviceable one anf fixed to the same location by making electrical connection properly complete all as specified and as directed. Cat No: SS91855 of Make-L&T or equivalent to C & S / Schneider |
| 148 | All as per item No-102 above but for eletrical motor 10 HP,Model MK1 FASD of L& T Make, CAT Pat: SS96254 or equivalent to C & S / Schneider |
| 149 | All as per item No. 102 above but for eletrical motor 40 HP,Model MK1 FASD of L& T Make, CAT Pat: SS94366. |
| 150 | S&F in repairs DOL starter in sheet steel enclosure AC 3 phase 415 volt 50 Hz suitable for 5/7.5HPcomplete. |
| 151 | Collecting water sample in clean bottle from location as directed for testing of physical test, chemical test, microbiological test as per IS-10500-1991 from NABL approvedchemical laboratoryand submitting test report complete. |
| 152 | M&L for scraping/cleaning surface of pipe lines of size 40mm to 150mm size and preparation of entire surface and applying one coat of Synthetic enamel paint epoxy coated ( Sea green colour for suction and discharge pipe lines) including writing, markingin stencil all as directed. |
| 153 | Supply and fixing in repair of LED type under water pool light fitting made in stainless steel body having size approx 110mm dia x55mm thick, 6 watt capacity design to operate on 12 volt AC with individual step down transformer mounted over 65mm x65mmx5mm water proof ABS Box individual switching system complete in all resepct making electrical connection including taking down existing unserviceable light/driver and testing all as specified and directed code No LED 6W ION of Exchange or equivalent in approved makes. |
| 154 | Material and labour for cleaning of swimming pool of capacity 800000 ltr including provision of bleaching powder,brushes,bucket, pump etc.complete with draining out of water complete all as specified and directed |
| 155 | Material and labour for cleaning of balancing tank of capacity 100000 ltr including provision of bleaching powder,brushes,bucket, pump etc.complete with draining out of water complete all as specified and directed |
| 156 | Supply and fixing of under water pool light driver suitable for 6-12watt, including taking out of unserviceable light driver and testing all as specified and directed. |
| 157 | Supply and fixing of water proof ABS box of size as per ground requirement for mounting under water pool light driver including taking out old unserviceable box ,making electrical connection and testing complete all as specified and directed.Make-: Austin/Aquastar |
| 158 | Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containerscomplete all as specified and as directed.Brands having pan india availability, acceptability& being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed. Make: Altoch-CH / Aquafit / Purichlor |
| 159 | Supply and adding Alum lump,grade I quality for treatment of swimming pool water |
| 160 | Supply of Soda Ash (Sodium Carbonate, Na₂CO₃) of pool-grade quality, free from impurities, suitable for adjusting pH levels in swimming pool water as per IS/BS standards. The material shall be delivered in original sealed bags of standard weight, handled, stored, and stacked properly at site. The supply includes testing for purity and proper labeling, as directed by the Engineer-in-Charge. |
| 161 | S&F in repairs chlorine testing KIT with colored sample complete with all testing fitment and OT solution in rexine finish box.Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 162 | S&F in repairs chloroscope (Chlorine & PH test kit) for estimation of residual chlorine in water comprises of Plastic box,two tube, Droper and colour filter for colour estimation.Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 163 | S&F in repairs Water Quality TDS tester with ATC, Digital and Pocket type,Range : TDS 0-999 PPM(Mg/L) Model No :- ATDS0016. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro |
| 164 | M&L for taking down old unsv and supply & lay 3Core 6 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with necessary saddle, clamps, bolts & nuts,all For connection from panel to motor etc All as Directed. Make :- POLYCAB / PLAZA / HAVELLS. |
| 165 | Dismantling the Decrin Dozing pump, cleaning, repairing, overhaulingreplacement of all unserviceable parts, nut, bolts,impellars, bushes, thrust bearing, clutch system, bowl assembly and repairing/replacement of pump shaft and re-assembling, commissioning and testing to make it operational / functionalcomplete all as specified and asdirected. |
| 166 | M& L for complete servicing of ozonator unit of capacity 150 gms/hr, oxygen concentrator and panel PCB board comprising four visit in a year (i.e quarterly basis) and one emergency breakdown visit with testing complete all as specified and directed. |
| 167 | M & L for replacement of new mosfets and electronics component same as motherboard, new components from driver card, oxygen pipe with new calibrate flow meter with standard, electrode servicing, ht transformer servicing,new ozone pipe with pump water, cooling pipe connection, program IC replace with new, drier card tunning, venturi setting etc complete all as specified and directed.Note-:(i) Guarantee of performance not less than 3 months shall be submitted by the contractor. |
| 168 | Supply & fix in repair thermal overload relay of range 20-33 A (Manual Reset) complete all as specified and directed ,Make:-Siemens/schneider/L&T |
| 169 | Supply and fix in repair Contactor 3-Pole,suitable capacity as per ground requirement upto 40 HPcomplete all as specified and directed. Make:-Siemens/schneider/L&T |
| 170 | Supply and fixing water pressure gauge 0 to 14 Kg/Sq cm including clamps, nuts, bolts & washers complete all as specified and as directed.. |
| 171 | S&F in repairs gunmetal gate or globe valve for 65 mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 172 | Ditto all as per item No 124 above but 50 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 173 | Ditto all as per item No 124 above but 40 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 174 | Ditto all as per item No 124 above but 25 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 175 | Ditto all as per item No 124 above but 20 mm dia bore complete. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 176 | M&L for testing of existing earthing using calibrated earth tester and submitting results to Engineer-in-Charge, including watering of each earth pit with 30 L water mixed with 20 kg salt one day before testing. Test result to be painted on earth pit using stencil with enamel paint complete all as specified and as directed |
| 177 | Taking out old/ unsv cast iron/ MS tank cover from RCC tank including dismatlling of RCC base support/ MS or cast iron frame and supplying & fixing cast iron tank cover in round shape of size 21 inches internal dia, with proper anchor in PCC with nut, bolts, anchor fastner etc with locking arrangement etc complete with two coats of black bituminous paint (drinking grade) for 1000 ltr/ 2000 ltr/ 3000 ltrall as specified and as directed Note-: Plastering and PCC work shall measured and paid seperately |
| 178 | Dismantling of existing PVC water storage tank covers and Supplying and fixing PVC tank cover round shape of suitable size as per ground requirement with locking arrangement and fixed in position etc complete all as specified and as directed |
| 179 | M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces cement plaster 1:6, all as specified and directed. |
| 180 | S & F foot valve of size 150 mm dia cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge. Make : Kirloskar or equivalant or as approved by GE. |
| 181 | Ditto all as per item No 130 above but 65 mm dia bore complete. |
| 182 | M&L for earthing complete with GI plate electrode of size 600x600x6mm thick burried directly to ground vertically to a depth not less than 2.25 meter below the ground level connected to GI strip 32x6mm size and earthing lead protected with 40mm bore light grade GI pipe filling around with charcoal dust and salt including excavation returning filling of earth and disposal of surplus soil to a distance not exceeding 50 metre and connected to GI strip by means of nuts, bolts and washers to earth plate, as shown in electrical plate No 3 of SSR Part-I 2010, PCC chamber with making PCC M-10 (Nominal Mix type B-I using 20 mm graded stone aggregate reinforced with 8mm dia mild steel round bar @ 75 mm c/c both ways and 12mm dia mild steel plain bar lifting handle 02 Nos funnels with wire mesh 20 mm dia GI pipe light grade for watering copper lugs with CI frame and testing complete all as specified and directed.Note: GI strip exceeding 7.5m will be measured and paid seperately |
| 183 | Supply and laying , galvanised earth strip 25x4mm fixed onwalls or through conduits /pipes etc including necessary fixing acessories complete all as specified and directed. |
| 184 | Supply only of clean, dry, and graded quartz filter sand suitable for swimming pool balancing tank and filtration system, conforming to IS:8419 (Part-1 & 2) or equivalent, of approved quality and grain size (coarse to fine) as per site requirement. The material shall be free from clay, silt, organic matter, and other impurities, and shall be delivered in moisture-proof bags at site as directed by the Engineer-in-Charge. |
| 185 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. |
| 186 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. |
| 187 | Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core including necessary connection and providing cable lugs as required all as specified. Note : Cable shall be clamped on wall. |
| 188 | Supply and fixing in replacement of LED securitylight fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection 4 kv surge in built protection completeall as per directed by Engr- in – charge. NOTE-: The Contractor shall furnished 3 year minimum written warranty Clause on LED luminaries from OEM. Make : Bajaj/Crompton/wipro/Jaquar |
| 189 | Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 130 x 180 x 77mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1010B /National/Sintax |
| 190 | S&F sluice valve 80 mm bore, cast iron body, flanged and drilled end, conforming to IS-14846, ISI marked, Class PN 1.6 including all joints with rubber or fibre board, gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed. Make-: Kartar/ Kirloskar/ Upadhyay |
| 191 | Ditto all as per item No 139 above but 100 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay |
| 192 | Ditto all as per item No 139 above but 150 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay |
| 193 | Supplying, fixing, jointingandtesting non-return valve suitable for GI tubing of size 80 mm bore size, (ISI Marked) both ends flanged and drilled for jointing including twoflangejointsandjointing material such as nuts, bolts washers rubberpackingetc including taking down complete all as specified and as directed. Make :- Kirloskar, Upadhaya , Leader, Zoloto. |
| 194 | Ditto all as per item No. 140 above but 50 mm dia bore complete all as specified & directed. |
| 195 | Supply only Bleaching powder grade -I ISI marked having stable available chlorine % by mass minimum 35% as per IS 1065,1971 and packed in 25 Kg bag complete all as specified and directed. Make : Vikram or equivalent as approved by GE. |
| 196 | Supplying, fixing, jointing and testing, in repair cast iron body, wafer type ISI marked, butterfly valve, 200mm dia conforming to IS-13095, pressure rating PN1.6, stainless steel SS 16(CF8M) disc, single piece SS 304 shaft, EPDM sleeve, luberized bushing as per BS standard lever operated type complete in all respect all as directed and as specified. Note:-The butterfly valve shall be fitted between two flanges on either side of flanges. The valve edge rubber shall be projected outside such that they are welded within the pipe flanges to prevent leakages. Make :- Kirloskar / Leader / Kartar / Upadhyay |
| 197 | Ditto all as per item No 142 above but 150 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay |
| 198 | Ditto all as per item No 142 above but 100 mm dia bore complete. Make-: Kartar/ Kirloskar/ Upadhyay |
| 199 | Supply and fixing in replacement First aid box PVC body with complete kit/accessories wall mounting type all as specified and directed. |
| 200 | Supply and fixing in repair brass Air release valve of size 25mm dia including all necessary fittings required for fixing complete all as specified and directed. |
| 201 | Maint/Cleaning ofPump house stations inside and out side area andremoving of creepers and vegetation raised along with water supply installation including surface dressing around the E/M installation not less then 3 mtrfrom out side fencing and removing the all waste material from site and Chemical spray inside and out side area of Sub station.Note:- T & P will be arranged by contractor |
| 202 | M & L for dismantiling the existing valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation D-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth workall plastered surfaces of valve chambers complete all as specified and directed by Engr-in-Charge. |
| 203 | Supply & Layingfixing, connecting and testingsteel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 20 mm bore, ISI marked. Make-: Tata/ Jindal/ BST/ Oswal |
| 204 | Ditto all as per item No 147 above but 25 mm dia bore complete |
| 205 | Ditto all as per item No 147 above but 40 mm dia bore complete |
| 206 | Ditto all as per item No 147 above but 50 mm dia bore complete |
| 207 | Ditto all as per item No 147 above but 80 mm dia bore complete |
| 208 | Ditto all as per item No 147 above but 100 mm dia bore complete |
| 209 | Supply and fix ISI Marked UPVC Pipe size 50 mm nominal dia,pressure pipe Schedule 80 with all connected acessories like UPVC bend,Tees,Unions,Sockets etc for each 3 mtr length of Pipe & solvent to join it all as specified and as directed.Make:Supreme/Dutron/Finolex/Duplon |
| 210 | Ditto all as per item No 148 above but 40 mm dia bore complete |
| 211 | Ditto all as per item No 148 above but 25 mm dia bore complete |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail