| Sl. No. | Item Description |
| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . |
| 3 | SCHEDULE A PART II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch ‘A’ PartII. |
| 5 | SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONS as listed in Sch ‘A’ PartIII. |
| 7 | SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch ‘A’ PartIV . |
| 9 | SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) |
| 10 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch ‘A’ PartV |
| 11 | SCHEDULE A PART VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for BSEWAGE DISPOSAL as listed in Sch ‘A’ PartVI |
| 13 | SCHEDULE A PART VII (AREA DRAINAGE) |
| 14 | Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch ‘A’ PartVII |
| 15 | SCHEDULE A PART- VIII (ROAD, PATH, CULVERT AND HARDSTANDING) |
| 16 | Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ PartVIII |
| 17 | SCHEDULE A PART- IX (FENCING AND GATE) |
| 18 | Lump sum price worked out by the contractor for COMPOUND WALL, FENCING AND GATE as listed in Sch ‘A’ Part IX |
| 19 | SCHEDULE A PART- X (AIR CONDITIONING AND REFRIGERATION WORKS) |
| 20 | Lump sum price worked out by the contractor for AIR CONDITIONING AND REFRIGERATION WORKS as listed in Sch ‘A’ Part X |
| 21 | SCHEDULE A PART- XI (EARTHWORK AND SITE CLEARANCE) |
| 22 | Lump sum price worked out by the contractor forEARTHWORK AND SITE CLEARANCE as listed in Sch ‘A’ Part XI |
| 23 | SCH \"A\" PART XII(MISCELLENEOUS B/R AND E/M ITEMS) |
| 24 | Supply of LPI model No ESE 60SS Protection radius 107 Mtrs @ 5 mtr height Level IV (Standarad),complete all as specified and directed |
| 25 | Supply of GI mast pole 5 Mtr x 50 mm dia and base plate with ESE adapter and Guy wire Kit including PVC coated Buy wire 20 Mtr, GI coupling - 1, GI pole clamp, GI wire clamp (Small) - 15 pieces, Turnbuckle - pieces, Eye bolt - pieces,complete all as specified and directed |
| 26 | Supply of one 70 Sqmm PVC insulated flexible copper FRLS cable,complete all as specified and directed |
| 27 | Supply of Lightening Strike recorder in IP 67 enclosurecomplete all as specified and directed |
| 28 | Supply of test link joint kit suitable for IP 65 weather proofbox with bus bar, glands, insulators, lugs and fixing accessories,complete all as specified and directed |
| 29 | Supply of copper wounded rod 17.2 mm x 3 mtr long 250 micron,complete all as specified and directed |
| 30 | Supply of Back fill compound in 25 Kg bag |
| 31 | Supply of earthing clamp for rod size mentioned above |
| 32 | Supply of poly plastic earth pitchamber of size Top dia 254 mm, bottom dia 330 mm height 260 mm, chamber enviorenment friendly, rust proof heavy duty weather proof, light weight. Load bearing capacity 05 Tonn, completeall as specified and directed. |
| 33 | Supply of FRP based earthing display board with support stand, width 254 mm, Length 380 mm and Hgeight 610 mm |
| 34 | M&L for construction of block masonry valve pit chamber of size 600x600x600mm (internal dimensions) with 50 mm thick foundation using PCC 1:3:6 (type D-2), block masonry wall built in CM 1:4, 15mm thick internal plaster including top of floor in CM 1:4, finished even and smooth without using extra cement, and 20mm thick external plaster in CM (1:4) and 3.15mm thick MS sheet cover including 40x40x6mm MS angle frame fixed in PCC 1:2:4 type B-1 coping with 25x4mm flat iron hinges, hold fasts, handles, locking arrangements, applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to all steel surface including excavation and earth work inany type of soil complete, as specified and as directed. |
| 35 | Supply, installation, testing & commissioning of 11 KV, 400 A,3 pole, 50 HZ , 26 KA for 3 sec rupturing capacity, floor mounted, compartmentalised, indoor type,free standing [grouted in PCC 1:2:4 type B1(Using 20 mm graded stone aggregate)],duly labelled with vinyl stickers, modular construction, 6 wayHT Panel fabricated in minimum 14 SWG CRCA sheet, supported with suitable sizebase channel not less than 75x75x5 mm,painted in Siemens Grey shade RAL 703, compartmentalised, dust and vermin proof, minimum IP 42 protection with bus /PT/relay compartment having IP 52 , doors and covers with non-ageinggasket, doors with concealed hinges with handle and locking facility, electrolytic grade copper bus bar of rectangular cross section of adequate size for 600 A , cable glands, cable bottom entry for incoming and outgoing cable, danger plate,thermostatically controlled strip heater with provision of double earthing terminals, lifting studs, louvers for proper ventilation covered with fine GI screen comprising of following : -(For Incomer and Outgoing at HPR Sub-Station)(a) 11 KV, 3 pole, 50 HZ 400 A draw out type VCB -06 Nos ( 02 Nos for incoming, 03 Nos for outgoing with bus coupler) confirming to IEC 62271-100 and 62271-200 ,E2 class,rupturing capacity 25 KA for 03 seconds, manual and motorised spring charging mechanism suitable to operated by 240 volts AC single phase/110 V DC supply. 24 volt DC universal motor 200 wattsand having charging time less than 10 seconds or as all per Original Equipment Manufacturer (OEM) design, with overload, earth fault and short circuit protection, interrupter life minimum 30000 times at rated current and minimum 100 times at short circuit current (b) Dual core dual ratio Current Transformer (CT) chamber, class E insulation, comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 5+5, burden not less than 15 VA and accuracy class 0.5, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 07 Sets for 07 VCBs. |
| 36 | (c) 1 No. Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, class \"E\" insulation, Burden 100 VA, Accuracy class 0.5 with HT HRC fuses & TPN MCBfor primary and secondary respectivelycomplete all as specified and as directed as per IS: 3156 - 02 Set(01 each for incoming)(d) SCADA compatibleself-powered , programmable type IDMT numerical relays having overload, earth fault and short circuit tripping facility, facility to record fault event with fault current and nature of fault , adjustableover current & earth fault and fault time setting (separate for earth fault and overcurrent), suitable DC auxiliary supply, housed on horizontal draw out type case, flush pattern with accessories duly connected with trip and alarm system -07 Nos total for complete protection of HT ,11 KV,3 Phase feederMODBUS communication on RS 485 communication port - 04 No. including 1 No voltage monitoring relay for under voltage / over voltage protection -06 Nos (e) PLC shall also be wired to all VCB\"s to monitor open/close status. The unit shall be supported with power pack of 110 Volt battery with battery charger (110-volt DC output) for supply backup for PLC & motor operation. The unit shall include all necessary standard fitting required at site.(f) One set of mechanical indicator for ON / OFF indication for all VCB.(g) LED type indication lamps for CB ON, CB Close, CB trip, spring charged , Trip circuit healthy with push button and oneset of capacitive voltage indication for R-Y-B -01 set for each VCB(h) One set of battery and battery charger to provide suitable back up as per OEM\"s instruction(i) Digital PT operated Voltmeter with inbuilt selector switch suitable for 11KV , 3 phase, 50 HZ CBs with accuracy class 0.5 -06 sets |
| 37 | (j) Digital CT operated Ammeter with inbuilt selector switch suitable for 11KV , 3 phase, 50 HZ,200-100 / 5+5 CTs with accuracy class 0.5 -06 sets (k) Power pack suitable capacity with maintenance free battery and charger to provide required aux supply to VCBs as per OEM recommendation (l) Any other standard fittings / accessories required for smooth functioning of HT panel Notes : - 1.HT panel shall be installed and commissioned by OEM at site including relay calibration as directed by Engineer-in-charge. 2.Bus coupler and incoming VCB will be provided with electrical and mechanical interlocking. 3.The job includes all control wiring with suitable size of copper conductor (mininimum 2.5 Sqmm ), necessary electrical connections and civil works.4. One of the incoming VCB Consisting of Manually spring charged breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories as required and instruction of Engineer Incharge. Microprocessor based numerical relay (IDMT relay) with 2 levels of over current and earth fault protection, 3 O/C and 2 E/F element with LED’s for fault indication and at least 15 trip records for over current & 15 for earth fault. Trip records must be with date & time stamping. multifuction meter with basic parameters like frequency, KW, KVA, KVAR, Power Factor, total harmonic distortion, Phase sequence indicator, Fault indicator etc. shall be suitable for EMS function with RS 485 port for communication. |
| 38 | Supply, installation, testing and commissioning of distribution transformer, capacity 2500 KVA step down, indoor type floor mounting, double copper wound core type 3 Phase 50 Hz AC, oil immersed withIS: 335 ISI marked filtered & dehydrated Transformer oil with \"ONAN\" type cooling with external cooling tubes / radiators having no load voltage ratio 11/.433KV (corresponding to principal tapping) delta connected on primary side (HV incoming) and star connected on secondary side (secondary out going) in accordance with vector group symbol (DYN-11) conforming to IS : 2026 and having off load tap changer in the steps of 2.5% on HV side to take care of voltage from (+)7.5% (+)5% to (+) 2.5% to give output on 433 volt secondary side and including initial oil filling to appropriate level, control cable, and following standard fittings complete all as specified and as directed including the followings:-(i) Oil conservator with oil filling hole cap and drain plug.(ii) 01 No of prismatic oil level gauge mounted on conservator wall with first fill of charge upto maximum level.(iii) Silica gel dehydrating breather with oil seal and with first fill of charge.(iv) Pressure release valve with automatic resetting arrangement after release of pressure- 01 Set(v) Adequate No of thermometer pocket including one thermometer.(vi) Top oil filter valve. (vii) Bottom oil filter cum drain valve.(viii) Rating diagram and terminal marking plate.(ix) Earthing terminal - 02 Nos. (x) Lifting lugs - 01 Set.(x) Jacking pads - 01 Set. |
| 39 | (xi) Under carriage with 4 Nos of plain rollers.(xii) Air release plug on main transformer tank.(xiii) Adequate Nos of cooling radiators.(xiv) 100 mm dial type oil temperature indicator with maximumread pointer and resetting device.(xv) 100mm dial type winding temperature indicator with maximumread pointer resetting device(xvi) Air insulated cables box on HV and LV side.(xvii) Buchholz Relay (having Contacts for Alarm & Trip). (xviii) OTI (having Contacts for Alarm & Trip).(xix) WTI (having Contacts for Alarm & Trip). (xx) Marshalling Box (having TTB Only)NOTE :- : (i) Routine test shall be carried out as per IS 1180. (ii) Pre-dispatch inspection at OEM factory premises shall be carried out by Rep of Accepting officer.(iii) Prior to manufacture the contractor shall get the general arrangement, drawing and design details of the transformer approved from GE.(iv) After installation of Transformer at site , the pre-commissioning test shall be carried out by SEI./EI |
| 40 | Supply, installing, commissioning & testing of Servo controlled voltage stabilizer (Confirming to as per BIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 2500 KVAas per requirements naturally oil cooled, indoor, unbalance type load, copper wound, with microprocessor based control card, digital type, relay free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, loses as per IS-2026 (including all amendments/updates) complete all as specified andhaving following specifications : (a) Input voltage 300 V to 480V (b) Output voltage stabilized at any designed/desired voltage 415V ±1% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time not to exceed 10 milli seconds (f) Sensitivity (±) 1% (g) Rate of correction 6 volts /second minimum (h) Efficiency more than 98% (i) Type of load : Three phase, unbalanced type(j) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz.(k) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil and temperature gauge (l) Charging motor of suitable capacity (m) Termination : Input & output termination as per IS : 3347.(n) Operation : Auto or Manual (o) Metering : Digital AC voltmeter with selector switch for input & Output voltage. |
| 41 | PROTECTION(i) Overload Cut-Off and short circuit Protection(ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency(iv) Single phase Prevention (v) Spike and surge protection(vi) Earth Fault protection.INDICATOR DIGITAL:-(i) Power indicator (ii) Voltage level indicator (iii) Frequency Meter(iv) Power Factor indicator (v) Ammeter, Temperature Meter, Digital Ammeter& Digital voltmeter (vi) Phase sequence indicator (vii) Oil level indicator |
| 42 | Supplying, installation, testing and commissioning of following capacity prefabricated Sandwich Type Copper Bus Trunking with minimum Class F insulation on 3 phase 4 wire 433 volts, 50Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, provision of tapping, adopter box and copper flexible for joints, continuous earthing with 2 Nos earth strip of suitable size(one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The rate should be quoted including MS Support structure for support of bus duct. it shall be tested as per IEC 61439 part 1 & 6, Zone 5, as per IS 1893 (Part 1) - 2002 and IEEE 693 - 2005 Tested with Vertical+Horizontal busduct and Plug-in Box assembly. Purity of aluminium conductor should not be less than 99.6%.Size : bus trunkingsystem with copper bus bar 4000 Amps, 50 KA breaking capacity,IP 54 protection (Transformerx2 to Volatge stablizer and Voltage stablizer to Feeder Panel 1) |
| 43 | Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type, CPRI approved, factory made free standing, floor mounting, dust and vermin proof, cubical type LT Feeder Pillar of suitable size to accomodate the below mentioned equipments along with adequate space for working fabricated from 2.00 mm thick CRCA sheetwith angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type,double door system,hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coatingwith pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 6000Amps ( Size of copper strip should not be less than 250 x 20 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for internal connection between ACBs and bus bar, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following.(For Changeover)(i)ACB 4000 Amp 4P ICW for 3 sec 65 KA (Manual draw out type micro processor release along with position indication, spring charge indication switch, trip indication switch, door flange, safety shutter and with fault recording+ LCD display)-03 Nos Two sets of ACB as incoming, meanwhile only one will operate at a time with integrated interlocking system.(ii) Panel mounted digital multifinction meter in 96x96 mm flush mounted case SP accuracy class 0.5, voltage measuring range 0-500V AC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A,F,PF,KW,KVA,KWH/KVh - 02 sets (iii) Indicator lamp RYB (set of three) - 02 sets |
| 44 | Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type , CPRI approved,factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar of suitable size to accomodate the below mentioned equipments along with adequate space for working fabricated from 2.00 mm thick CRCA sheetwith angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type,double door system,hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coatingwith pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 7000Amps ( Size of copper strip should not be less than 150 x 10 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following.LT Panel IP 42, type tested from ASTA/CPRI/ERDA as per IEC 61439 Part 1 & 2, internal arc compliance of 85kA-0.5s as per IEC 61641, IK10 as specified in IEC 62262,ICC ES AC -156, 3.2g Compliance. The LV Panel shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (ACB with phase sequence protection (ANSI 47)/MCCB/Control gear etc) should be from same OEM. The type designation and certification label on the panel shall prominently feature the OEM\"s name. Make of Panel : Siemens ( Sivacon S8 ) , Schneider ( OKEN ) , Lauritz Knudsen ( ENERSYS ) (Feeder Panel 1) |
| 45 | (b) Incoming : (i)ACB with phase sequence protection (ANSI 47) 5000 Amp 4P ICW for 1 sec 65kA EDO ACB with phase sequence protection (ANSI 47) with microprocessor release with Password Protection in Release having LSING protection with RS485,Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have metering & oLED display ofCurrent, % Loading, Imin, Imax, Current Bargraph, last 20 trip data, Phase-1, 2 & 3-Total, Fundamental, THD, oscillograph of fault current. Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP-02 No (one working one stand by)(ii) Panel mounted digital multifinction meter in 96x96 mm flush mounted case multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication-06 sets(iii) Indicator lamp RYB (set of three)-06 set(iv) CT 5000/5 A 15 VA Cl 1 (set of 3 Pcs)-02 set(v) CT 2000/5 A 15 VA Cl1 (set of 3 Pcs)-01 set, (vi) CT 630/5 A 15 VA Cl1 (set of 3 Pcs)-10 set (vii) CT 400/5 A 15 VA Cl1 (set of 3 Pcs)-02 set, (vii) CT 250/5 A 15 VA Cl1 (set of 3 Pcs)-02 set,(viii) MCB 6A, SP, 10 KA for protection (set of 3 Pcs)-05 set |
| 46 | (c) Outgoing : (i) ACB with phase sequence protection (ANSI 47) 630 Amp 4P , Icw for 1 sec 65kA EDO ACB with phase sequence protection (ANSI 47) with microprocessor release with Password Protection in Release having LSING protection with RS485,Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have metering & oLED display ofCurrent, % Loading, Imin, Imax, Current Bargraph, last 20 trip data, Phase-1, 2 & 3-Total, Fundamental, THD, oscillograph of fault current. Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP-10 Nos (8 W+ 2S )(ii) ACB with phase sequence protection (ANSI 47) 2000 Amp 4P ICW for 1 sec 65kA EDO ACB with phase sequence protection (ANSI 47) with microprocessor release with Password Protection in Release having LSING protection with RS485,Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have metering & oLED display ofCurrent, % Loading, Imin, Imax, Current Bargraph, last 20 trip data, Phase-1, 2 & 3-Total, Fundamental, THD, oscillograph of fault current. Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP. -01 Nos (for APFC panel) (iii) MCCB 4 pole ,415 volts , AC supply , 250 Amps, 36 KA breaking capacity Ics=Icu, Ics=100% of Icu=36 kA,having LSING Protection, double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 158-630A, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. Seperate LED indication for Pwr, O/L, S/C, INST, E/F -02 Nos (1W+1S ) (for LT panel ) |
| 47 | Supply,installation,testing and commissioning 3 phase and neutral , 415 volts indoor type , CPRI approved,factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar of suitable size to accomodate the below mentioned equipments along with adequate space for working fabricated from 2.00 mm thick CRCA sheetwith angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type,double door system,hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coatingwith pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 500Amps (copper strip ) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. LT Panel IP 42, type tested from ASTA/CPRI/ERDA as per IEC 61439 Part 1 & 2, internal arc compliance of 85kA-0.5s as per IEC 61641, IK10 as specified in IEC 62262,ICC ES AC -156, 3.2g Compliance. The LV Panel shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (ACB with phase sequence protection (ANSI 47)/MCCB/Control gear etc) should be from same OEM. The type designation and certification label on the panel shall prominently feature the OEM\"s name. Make of Panel : Siemens ( Sivacon S8 ) , Schneider ( OKEN ) , Lauritz Knudsen ( ENERSYS )(Feeder Panel 2) |
| 48 | (b) Incoming : MCCB 400 Amp 4P 36 KA micro processor based release-01 No(ii) Panel mounted digital multifinction meter in 96x96 mm flush mounted case SP accuracy class 0.5, voltage measuring range 50-520V AC, CT secondary site suitable 1A/5A(iii) Indicator lamp RYB (set of three)-02 set(c) Outgoing : (i) MCCB 400 Amp 4P 36 KA micro processor based release-01 No |
| 49 | Supply , Installation , comissioning and testing of APFC panel for 3 phase 415 V 50 HZ system of capacity 800 KVAR with APP super heavy duty , capacitor in 8 Steps and MCCB as incomer complete all as specified and directed. The APFC panel should have capacitor duty contactor with duty AC6B, 3 CT sensing APFC relay. |
| 50 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front openable double door system and cable alloy(Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricatedhaving modern fabrication and testing process.( LT Panel 3 (for Adm Building)a) TPN aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long.b) Incoming MCCB250 Amps 4 pole 415 Volts AC,Icu=100%Ics, rupturing capacity 36 KA.Confirming to IS/IEC 60947-2-02 Nosc) Outgoing MCCB 160 Amps 4 pole 415 Volts AC,Icu=100%Ics, Adjustable type thermal releasefor over current,short circuit & earth fault with display and fault discrimination rupturing capacity 25 KA.Confirming to IS/IEC 60947-2 -02 Nos(d)\"-ditto- but MCB TPN 40 Amp 10 KA C Curve - 1 Nos(e)MCB SPN32 Amps 10 KA C Curve- 03 Nos |
| 51 | S&F newpole mounted thermoplastic cable junction box for street light 4-5 modulewith IP-65 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of approximate size 126x288x111 mm with front door opening system including terminals for one incoming and two outgoing cables of size 10 Sqmm, 4 core, one MCB SP 3 to 6 Amps, 240V AC with mounting clamp of flat iron, nuts, bolt and washers complete all as specified and directed. |
| 52 | Supply and fixing bracket for street light fitting of any size made out of GI pipe medium grade 40 mm dia, 1.5 mtr length bend to required size and shape including provisiob of clamps and fitting in position and including two coat of aluminum paint over a coat of red oxide primer complete all as specified and directed. |
| 53 | M&L for providing twin core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable (for phase earth and neutral) of size 2.50 Sqmm for connection drawing through pole or GI brackets of street light fittings with junction box or OH conductor complete all as specified and directed. |
| 54 | S&F for cable route/joint indicator made of RCC slab of size 90 cmx 30 cm x10 cm embeded in ground on the route of cable duly marked with HT cable / HT cable joint . |
| 55 | M&L for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50Mtrs below ground level) connected to GI wire 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified incl 20 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, PCC chamber using PCC(1:3:6) type C-1 using 20mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally up to 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on Electrical plate No.3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results (in white) on a black painted M.S. Plate (size 300x300x3mm th) duly welded with angle iron of size 40X40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.Note :- (i) GI wire and GI pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) The rates quoted by the contractor are deemed to be included for MS sheet of size 300x300x3mm th, fixed with necessary nuts and boltson angle iron of size 40X40x5mm, 60cm long and grouted with PCC block of size 200x200x250mm(PCC 1:3:6 using 20mm grade stone aggregate including necessary earth work for marking the result and purpose. |
| 56 | M&L earthing for power transformer complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick burried directly in ground (Earth pit not less than 3.0 m deep below ground level) with top edge of the plate not less than 2.25m below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavationin any type of soil(except rock), filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from outside defence land, and to be mixed with and includingbentonite - 03 bags of 25 KG each for each pit,construction of PCC earth pit chamber of size 900 x 900 x 450 mm ,RCC chamber cover plate, wire mess, funnel, test point, 32 mm dia GI protection pipelightgrade and40 mm GImedium grade peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed. |
| 57 | Supply only Black/Blue PVC insulating electrical mat of 1 meter x 2 meter x 3 mm suitable for 11 KV as per as IS 15652, |
| 58 | M &L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 59 | Supply, installation, testing & commisioningof flame proof motor of capacity 2 HP, foot/flange mounted, 1440 RPM, 415 Volts incl pump 110 LPM temp 90 degree along with mounting base plate coupling & PCCfoundation as permanufacturer design, complete all as specified & directed. |
| 60 | Supply, installation & testing of flow meter flanged end SS 304, out put 4 to 20 mA, operating temp 70 degree celcius, mounting in line horizontal, flame proof enclosure, 230 V AC,9 Character X 2 Line LED Display, flow range 4 to 40 m3/hr, for line size 50 NB (2 inch) complete all as specified & directed |
| 61 | Supply & fix DOL starter of 2 HP incl 4 sqmm 3 core cable from starter to motor, complete all as specified and directed |
| 62 | Supply and fix Flame proof - weather proof MCB socket & plug combined 16 A, 250 V(2P+Earth) |
| 63 | Supply and fix Foot Valve conforming to IS 4038, 50 mm (2”) dia , complete all as specified & directed |
| 64 | Supply and fix Strainer Y type conforming to IS, size 50 mm (2”) dia complete all as specified & directed |
| 65 | M & L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users conventional type |
| 66 | M&L for soakage well excavation , in any type of soil , foundationinPCC 1:3:6, walls of honeycombed masonry with topring of M25concreteincluding intercepting chamber and screen chamber made of brick masonary inCMRCC cover slab in M25/SFRC coverinter connecting ipes ofRCC /DWC /SWG complete filled with brick bats of size 2.40 m dia x 4.50 m effective depth |
| 67 | Supply only chain link fencing of mesh size 100mmx100 mm made of 4 mm dia GI wire hot dip galvanised having zinc coating 260 to 280 GSM conforming to IS 2721 -2003, complet all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |