| Sl. No. | Item Description |
| 1 | Cleaning of following Sewage Treatment Plant Chambers by professional agency after De-watering of sewage and cleaning with Jet Pressure Water Pump for dirt, silt and agae, scrapping with steel brushes/ hessin cloths of the chamber walls from inside including floor of the chamber and apply solution of Potassium Permanganate (KMnO4) complete and providing two coats of anti corrosive paint including watering etc and repair to vent pipes including providing wire mesh and clamps complete all as specified and directed by Engineer-in-Charge.Note: If work is not done upto satisfaction level of concerned Engineer-in-Charge,the work will be redone upto the required level without any extra cost. Necessary tools and safety measures for man power to be arranged by contractor.Stilling Chamber of size 1.40 x 1.40 x 1.40 m. |
| 2 | -Ditto- all item as per Ser No 1.00 above but Pumping Station Plant at Central Sewage Treatment Plant. |
| 3 | -Ditto- all item as per Ser No 1.00 above but Grit Chamber of size 3.6M X 1.2M X 1.1 M |
| 4 | -Ditto- all item as per Ser No 1.00 above but Equalization Tank of size 8.30 M (Dia) x 3.50 M |
| 5 | -Ditto- all item as per Ser No 1.00 above but Moving Bed Bio Reactor of size 4.00 M (Dia) x 5.00 M |
| 6 | -Ditto- all item as per Ser No 1.00 above but Tube Settler of size 7.00 M x 6.50 M x 2.70 M |
| 7 | -Ditto- all item as per Ser No 1.00 above but Chlorine Contact Tank of size 7.00 M x 4.50 M x 2.00 M |
| 8 | -Ditto- all item as per Ser No 1.00 above but Sludge Holding Tank of size 8.10 M (Dia) x 2.50 M |
| 9 | -Ditto- all item as per Ser No 1.00 above but Treated Water Tank of size 13.50 (Dia) x 6.00 M |
| 10 | -Ditto- all item as per Ser No 1.00 above but Sewage Pump Stations of dia 2M and depth 10M |
| 11 | Opening and reassembling of Non clog submersible motor (STP motor) after rewinding and replacement of worn out spare parts including taking out the burnt winding wire and rewinding of submersible motor following capacity with new PVC insulated solid copper conductor (wire) superior quality of approved make, gauge/size & number of wire as per existing including insulation material and for suitable RPM including rotor balancing, minor spares, fixing new mechanical seal for avoiding of shorting of motor and replacement of unserviceable spare parts and reassembling the components & testing for function ability including taking old unserviceable motor from treated water tank complete all as specified and directed. Note: The Job include the opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land. Motors will be given for repairing as per the site condition and need for repair being maintenance work. Submersible motor of capacity 25 HP, 3 phase, 415 volts |
| 12 | -Ditto- all item as per Ser No 2.00 above but Submersible motor of capacity 7.5 HP, 3 phase, 415 volts |
| 13 | -Ditto- all item as per Ser No 2.00 above but Submersible motor of capacity 3.0 HP, 3 phase, 415 volts |
| 14 | Opening and reassembling of STP monoblock /centrifugal pump (motor) after rewinding and replacement of worn out spare parts including taking out the burnt winding wire and rewinding of monoblock/ centrifugal pump (motor) following capacity, Three Phase, 415 volts with new PVC insulated solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacement of unserviceable spare parts and reassembling the components & testing for function ability, complete, all as specified & directed.Note: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land and testing of RPM to be done after installation on Ground after rewinding. Motor will be given for repairing as per the site condition and need for repair being maintenance work. (ii)Unit rate (quoted by the tenderer) shall be deemed to included for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.Monoblock/Centrifugal motor of capacity 40 HP, 3 phase, 415 volts |
| 15 | -Ditto- all item as per Ser No 3.00 above but Monoblock/Centrifugal motor of capacity 12.50 HP, 3 phase, 415 volts |
| 16 | -Ditto- all item as per Ser No 3.00 above butMonoblock/Centrifugal motor of capacity 7.50 HP, 3 phase, 415 volts |
| 17 | -Ditto- all item as per Ser No 3.00 above butMonoblock/Centrifugal motor of capacity 5 HP, 3 phase, 415 Volt, |
| 18 | -Ditto- all item as per Ser No 3,00 above but Monoblock/Centrifugal motor of capacity 1.50/2.0 HP, 3 phase, 415 volts |
| 19 | Deep Groove ball/roller bearing (Double sealed ball bearing) for the following capacity of STP Pump (Primary and secondary) complete all as specified and directed. Make : SKF/NBC/TATA/FAG/UBC.Note: The rates include cost of two nos bearing as per pump design. Both the bearings(as per pump make) to be replaced at the same time.Centrifugal pump/mono block pump set of capacity 40 HP |
| 20 | -Ditto- all item as per Ser No 4.00 above but Centrifugal pump/mono block pump set of capacity 12.5 HP |
| 21 | Ditto- all item as per Ser No 4.00 above but Centrifugal pump/mono block pump set of capacity 7.5 HP |
| 22 | Ditto- all item as per Ser No 4.00 above but Centrifugal pump/mono block pump set of capacity 5.0 HP |
| 23 | Ditto- all item as per Ser No 4.00 above but Centrifugal pump/mono block pump set of capacity 1.5/2.0 HP |
| 24 | Centrifugal/Monoblock STP Pump motor MS coupling capacity 40 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed. |
| 25 | Centrifugal/Monoblock STP Pump motor MS coupling capacity 12.5 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed. |
| 26 | Centrifugal/Monoblock STP Pump motor MS coupling capacity 7.5/5.0 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed. |
| 27 | Centrifugal/Monoblock STP Pump motor MS coupling capacity 1.5/2.0 HP motor (Beam, Jaw, Gear any type) including taking down old unserviceable complete all as specified and directed. |
| 28 | Induction Motor prelubricated ZZ bearing (DE and NDE) for capacity 40 HP motor for STP (Primary and secondary) complete all as specified and directed. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings(as per motor frame type) to be replaced at the same time. |
| 29 | Induction Motor prelubricated ZZ bearing (DE and NDE) for capacity 12.5 HP motor for STP (Primary and secondary) complete all as specified and directed. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings(as per motor frame type) to be replaced at the same time. |
| 30 | Induction Motor prelubricated ZZ bearing (DE and NDE) for capacity 7.5/5.0 HP motor for STP (Primary and secondary) complete all as specified and directed. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings(as per motor frame type) to be replaced at the same time. |
| 31 | Unloring and lowering the Non clog submersible pump (STP) of capacity 25 HP and removing dirt, waste from it and clean it and making it serviceable complete all as specified and directed. |
| 32 | Servicing of Air-blower of capacity 760 Cum/Hour with pressure 0.65 Kg/SqCM of RPM 1000, including replacement of Paper filter,oil of air blower of Make : Everest Model M-710 complete all as specified and directed. Note : All necessary Tools & Plants required for servicing to be included in quoted rates. |
| 33 | V Belt, Heat and Oil resistant of Model SP13, 2150complete all as specified and directed. MAKE : FENNER or equivalent. |
| 34 | Servicing of Decanter Centrifuge including greasing of Bearing at Feed/ Slurry end and Main Bearing at Liquid discharge, Cleaning of Scroll/ Conveyor, Bowl, Pump blades complete by authorised OEM manufacturer of Make : Alfa Laval. Note : All necessary Tools & Plants required for servicing to be included in quoted rates. |
| 35 | Bourdon type glyserin filled pressure gauge (150mm dia) complete with siphon tubewith isolating cock having range of 0 to 7Kg/Cm2 as per IS 8793 complete all as specified and directed. Make : H Guru Model No. 6PSSSW2or equivalent as approved by GE. |
| 36 | M & L for fixing Tube Deck Media of size 100mm/150mm X 750mm/1000mm (as per sample) for Tube Settler Chamber as per sample complete all as specifie and directed.Note : Top up the media as some media get damage during removing & settling after cleaning work of tube settler. |
| 37 | MBBR Media Virgin PP UV stablilized based media with size of 16x22mm/ 17x24mm with removal performace of 30 BOD complete all as specified and directed.Note : Top up the media as some media get damage during removing & settling after cleaning work of MBBR tank 1 & 2. |
| 38 | Supply,Install,testing & commissioning of Chlorine Dozing pump 230 V AC ,50 Hz capacity 50Hz capacity upto 10 LPH @ 5 kg/Sqmm pressure pump head PP with glass filled,teflon diaphargm with suction and discharge tubing3 mtrs along with PVC injector with NRV with 150 ltrs capacity heavy duty FRV tank complete.Make : Sathya SaiModel no : SSAPS/CDPET/10Note : Old rusted/corroded/damaged Dozing pump of different specification & old model shall be considered under schedule of credit. |
| 39 | Supply, laying and joing (By butt fusion welding method) in standard length BIS marked (high density polyethylene Pipe) HDPE pipe suitable for potable water as per IS specification No 4984/1995 (Pressure rating 6 Kg/Cm2 PE-100) and fittings (specials suitable to HDPE pipes) including taking down old unserviceable pipe complete all as specified and directed.25mm nominal dia HDPE Pipe (Outer Dia) |
| 40 | -Ditto- all item as per Ser No 20.00 above but 40mm nominal dia HDPE Pipe (Outer Dia) |
| 41 | -Ditto- all item as per Ser No 20.00 above but63mm nominal dia HDPE Pipe (Outer Dia) |
| 42 | -Ditto- all item as per Ser No 20.00 above but 90mm nominal dia HDPE Pipe (Outer Dia) |
| 43 | -Ditto- all item as per Ser No 20.00 above but 125mm nominal dia HDPE Pipe (Outer Dia) |
| 44 | -Ditto- all item as per Ser No 20.00 above but160mm nominal dia HDPE Pipe (Outer Dia) |
| 45 | -Ditto- all item as per Ser No 20.00 above but 180mm nominal dia HDPE Pipe (Outer Dia) |
| 46 | Rectification of Leakages by necessary excavation (upto one length of 6.00 RM) in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to DI/CI/ HDPE of following sizes pipe with MS clamp including rubber cushioning, 3mm thick and 300mm wide with hole drilled for nutbolts including suitable nuts and bolts for rectification of leakages complete all as specified and directed.Note: Cost of JCB for lifting of pipe for repair will be part of quoted rates.40mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia) |
| 47 | -Ditto- all item as Per Ser No 21.00 above but 63mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia) |
| 48 | -Ditto- all item as Per Ser No 21.00 above but 90mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia) |
| 49 | -Ditto- all item as Per Ser No 21.00 above but 125mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia) |
| 50 | -Ditto- all item as Per Ser No 21.00 above but 160mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia) |
| 51 | -Ditto- all item as Per Ser No 21.00 above but 180mm nominal dia HDPE/ GI/CI/DI Pipe (Outer Dia) |
| 52 | Supply and fixing in replacement of HDPE flanged pipe of equilisation and sludge tank of size 65mm complete all as specified and directed. |
| 53 | Supply and fixing in replacement of cable of size 1.5 sqmm multistranded copper conductor,8 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed. |
| 54 | Supply and fixing in replacement of cable of following sizesmultistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.4 Sqmm4 Core + 4 Core 1.5 Sqmm |
| 55 | -Ditto- all item as Per Ser No 24.00 above but8 Core 4 Sqmm |
| 56 | Supply and fixing in replacement of cable of size 16 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps &jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed. |
| 57 | Supply and fixing in replacement of cable of size 2.50 sqmm (nominal area), copper conductor, PVC insulated, sheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through existing conduit fixed on surfaces of wall/ceiling complete including disconnecting & taking out carefully old unserviceable sub main wiring from existing serviceable conduit complete all as specified and directed. Note: Two run for Phase and Neutral of 2.50 sqmm cable shall be measured as one run length for payment purpose. |
| 58 | Supply and fixing in replacement of LED flood lights of capacity 100 Watt, complete with all fittings and fixtures including disconnecting & taking out carefully old unserviceable complete all as specified and directed. Make : Havells Cat Part No. JETAIRISFLS100W LED757ASYMLTG or equivalent of Bajaj/ Philips. |
| 59 | Supply and fixing in replacement of LED street light fitting of capacity 60 Watt, complete with all fittings and fixtures including disconnection and taking out carefully old unserviceable complete all as specified and directed. |
| 60 | MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. |
| 61 | MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. |
| 62 | MCCB, 4 Pole, 125 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. |
| 63 | MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. |
| 64 | MCB Triple Pole with Neutral with overlaod and short circuit protection \"C\" Series, 63 Amps rating, rupturing capacity 10 kA, 415 Volts, AC supply, 50 Hz, including disconnecting & taking down old unserviceable MCB, complete all as specified and directed. |
| 65 | MCB Single Pole with Neutral with overlaod and short circuit protection \"C\" Series, 63 Amps rating, rupturing capacity 10 kA, 415 Volts, AC supply, 50 Hz, including disconnecting & taking down old unserviceable MCB, complete all as specified and directed. |
| 66 | MCB Single Pole with overlaod and short circuit protection \"C\" Series, 32/40 Amps rating, rupturing capacity 10 kA, 415 Volts, AC supply, 50 Hz, including disconnecting & taking down old unserviceable MCB, complete all as specified and directed. |
| 67 | Supply and fixing in replacement of contactor of capacity 40Amp, MNX 40, 415 Vcomplete all as specified and directed |
| 68 | Supply and fixing in replacement of contactor of capacity 75Amp, 415 V complete all as specified and directed |
| 69 | Supply and fixing in replacement of single phase preventor as per sample complete all as specified and directed |
| 70 | Supply and fixing of over load relay of capacity upto 40 Amp as per sample complete all as specified and directed. |
| 71 | CI reflex valve/Non return valve (NRV) of size 150mm bore, cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed. |
| 72 | CI reflex valve/Non return valve (NRV) of size 100mm bore, cast iron body, (ISI marked) with confirming to IS 5312 (Part-1) : 2004, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint including dismantling & taking out old unserviceable non return valve complete all as specified and as directed. |
| 73 | Cast Iron/Gun Metal foot valve of size 80mm bore (ISI marked) flanged end/threaded type (heavey grade) with rubber insertion sheet 3mm thick, nuts, bolts and washers including taking down old existing unserviceable foot valve complete all as specified & directed. |
| 74 | Contactor for STP motor capacity 40 HP, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable contactor and cleaning of carbon complete all as specified and directed. |
| 75 | Contactor for STP motor capacity 12.5 HP, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable contactor and cleaning of carbon complete all as specified and directed. |
| 76 | Contactor for STP motor capacity 7.5 HP, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable contactor and cleaning of carbon complete all as specified and directed. |
| 77 | Motor starter relay for STP motor capacity 40 HP, Motor Starter (Amp rating as per site) including removing of exiting burnt/ unserviceable relay complete all as specified and directed |
| 78 | Motor starter relay for STP motor capacity 12.5 HP, Motor Starter (Amp rating as per site) including removing of exiting burnt/ unserviceable relay complete all as specified and directed |
| 79 | Motor starter relay for STP motor capacity 7.5 HP, Motor Starter (Amp rating as per site) including removing of exiting burnt/ unserviceable relay complete all as specified and directed |
| 80 | Cast iron body sluice valve heavy duty class ‘PN-1.6’, 80mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed. |
| 81 | Cast iron body sluice valve heavy duty class ‘PN-1.6’, 100mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed. |
| 82 | Cast iron body sluice valve heavy duty class ‘PN-1.6’, 150mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, high tensile stainless steel spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve, complete all as specified & directed. |
| 83 | Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 40mm bore or brass ferrule and fixed including dismantling & taking out old unserviceable valve complete all as specified & directed. |
| 84 | Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 65mm bore or brass ferrule and fixed including dismantling & taking out old unserviceable valve complete all as specified & directed. |
| 85 | Cast iron body butter fly valve heavy duty, 100mm bore, ISI marked with confirming to IS, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 100mm bore, complete all as specified & directed. |
| 86 | Cast iron body butter fly valve heavy duty, 150mm bore, ISI marked with confirming to IS, both flanged ends and drilled, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 150mm bore, complete all as specified & directed. |
| 87 | M&L for Construction of stone masonary valves pit of size 1500mm x 1500 mm x 1500mm (internal dimention of chamber) made with bulit in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of near cement, PCC coping type B1 (1:2:4) using 20mm graded stone aggregate including necessary form work with MS frame with angle iron 50x50x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime complete as specified and locking arrangement complete all as specified and directed. |
| 88 | M & L for construction of tin Shed (Angle iron grouted on ground/cemented surface along with fully covered the pumpset & panel from tin sheet from three sides and properfixing arrangement and welding work to be carried out as per the entire satisfaction of Engr-in-Charge. |
| 89 | Maintenance and servicing of DG Set of capacity 250 KVA complete including draining out of Diesel from tank, cleaning the tank throughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber throughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petrolium jelly to battery terminal posts & brass connectors, changing of V-Belts, changing of rubber housing and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc. adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the maufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed. Note :- Cost of diesel for testing shall be deemed to be included in the quoted rate. |
| 90 | Maintenance and servicing of DG Set of capacity5 KVA to 10 KVA complete including draining out of Diesel from tank, cleaning the tank throughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber throughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petrolium jelly to battery terminal posts & brass connectors, changing of V-Belts, changing of rubber housing and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc. adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the maufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed.Note :- Cost of diesel for testing shall be deemed to be included in the quoted rate. |
| 91 | Cuttings grass/herbs near installation, plant and sumps complete cleaning of installation, valve chamber and cleaning of installation including necessary tools and safety measures where ever required complete all as specified and directed. |
| 92 | Testing of Sewage Water Stilling chamber (Inlet) and Treated Water (Outlet) sample at authorised NABL accredited Government laboratory for biological fitness of water (pH Value, total Suspended Solids, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), total Residual Chlorine, total Coliform) on Monthly basis including glass bottle for collection of sample complete all as specified. |
| 93 | Taking down of existing u/s street light of any type/ Bollard light/Perimeter light /high mast light and building security lights ofany type any makefrom pole , hangers, buildings/Highmast poles at any height etc any type complete after removing from existing mounting arrangements/ street light bracket etc and re-fixing the same after necessary repair / replacement of unserviceable light with new fittings /component etccomplete all as specified and directed by Engineer-in-Charge.Note:- (i)Replacement and fixing of unserviceable component etc required will be measured & paid separately under relivent items as supply only. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items as supply only.(iii) Any typeof Ladder required for dismantling of light from pole/ from hanger/high mast pole shall be arranged by the contractor. (iv) In case the street lights are not working due to any fault in the cables, carbon in the terminals/ joints or fault in over head lines, the same shall be cleared by the contractor, and the cost of the same shall be deemed to be included in the unit quoted rates. (v)The contractor shall provided suitable vehicle to the tradsman attending complaint of street lights (vi)The contractor or his supervisor will obtain street light complaint from the JE E/M or Engr-in-charge on daily basis and the complaint shall be attended and rectified within 24 hours of the complaint issued by the JE E/M or Engr-in-charge failing which a panal recovery of 2 times of quoted rates shall be made from the RAR for each not attended or rectified complaint. |
| 94 | Supply only electronic driver suitable for LED street lights of capacity 25 to 45 watt as per existing complete all as required at site |
| 95 | Supply only electronic driver suitable for LED flood lights of capacity 60 to 90 wattas per existing complete all as required at site |
| 96 | Supply only electronic driver suitable for LED flood lights of capacity120 watt to 150 watts as per existing complete all as required at site |
| 97 | Supply only electronic driver suitable for LED flood lights of capacity200 watt to 250 watts as per existing complete all as required at site |
| 98 | Supply only electronic driver suitable for LED bollard/gardenlights of capacity8 watt to 10 watts as per existing complete all as required at site |
| 99 | Supply only surge protection device 10 KV,suitable for LED street lights of capacity 45 watt to 250 watts, single phase, 230 volts, 50 hz complete all as specified and directed |
| 100 | Supply, fixing and connecting elastomerinsulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 including taking down of old unserviceable connection wire complete all as specified and directed |
| 101 | Supply and fix junction box made out of Fiber reinforced plastic with IP 55/IP 65 protection of size not less 200 x 140 x 95 mm (in side dimensions) , having 5 way terminals mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Noscable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any typeall as directed. |
| 102 | Supply and fix junction box made out of fiber reinforced plastic with IP 55/IP 65 protection of in side size not less 350 x 250 x 140 mm (In side dimensions) , having 5 way terminals suitable for 70 to 95 sqmm 3.5 core cable,mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any typeall as directed. |
| 103 | Supplying and fixing 1100 volts grade heavy duty, 10sqmm twin core cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm in and including taking down of old service connection compete all as specified and directed. |
| 104 | S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & boltsfor protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16) complete all as specified and directed. |
| 105 | Supply and fixing in repair energy efficient LED street light fittingsof capacity not less than 45 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED\"s should have lenses for better throw across &along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections all as directed. |
| 106 | Supply and fixing in repair energy efficient LED street light fittingsof capacity not less than 60 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED\"s should have lenses for better throw across &along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections all as directed. |
| 107 | Supply and fixing in repair energy efficient LED street light fittingsof capacity not less than 70 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED\"s should have lenses for better throw across &along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections all as directed. |
| 108 | Supply only, LED flood light of capacity 150 watt,aesthetically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection efficient high output emitter LED for better thermal management of capacity 150W(5700K CCT) , individuals LED\"s should have lenses for better throw across, system luminous efficacy lm/w grater than or equal to 100lm/w, high efficiency long life LED module with SMD LED package mounted on MCPCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos , inetgral , isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other sagety test as Per IS-15885 part -2/sec 13, the LED flood light should be LM 79 report and IES file,in and including taking down of old unserviceable light fitting complete all as specified and directed |
| 109 | Supply, fixing, connectingand testing LED bollard light decorativetype in cylinderical shape with opel acrylic diffuser and IP 66 protectionwith reflector 10 watt, as per existing at site completehaving fixing arrangements at bottom with necessary nuts, bolts, washers completein and including taking down of old unserviceable lights complete all as specified and directed, |
| 110 | Supply, fixing, connectingand testing LED bollard light decorativetype with reflector not less than 10 watt as per sample existing at site, IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution having fixing arrangements at bottom with necessary nuts, bolts, washers complete in and including taking down of old unserviceable lights complete all as specified and directed, |
| 111 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site. |
| 112 | M&L tibba sand for cushioning to under ground cable in trenches/existing cable trenches/ductsin layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. |
| 113 | M& L for40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable including taking down all as specified and directed. |
| 114 | M/L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 115 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 116 | Supply,laying or fixing or passing through GI pipe,commissioning and testing of PVC / XLPE insulated, armouredheavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately under relevant items:-10 Sqmm 2 core |
| 117 | -Ditto- all item as per Ser No 85.00 above but16 Sqmm 4 core |
| 118 | -Ditto- all item as per Ser No 85.00 above but 25 Sqmm 4 core |
| 119 | -Ditto- all item as per Ser No 85.00 above but35 Sqmm 3.5 core |
| 120 | -Ditto- all item as per Ser No 85.00 above but50 Sqmm 3.5 core |
| 121 | M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc in and including taking down of existing pipecomplete all as specified and as directed.40 mm bore |
| 122 | -Ditto- all item as per Ser No 86.00 above but50 mm bore |
| 123 | Taking out existing PCC/steel tubular LT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors. |
| 124 | Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtrlong including painting of pole with one coat red oxide primer & two coats of aluminum paint & emebeded portion shall be painted with two coat of black bituminous paint all as specified in ISwith following specifications:-(i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points.(ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding of size 600x600mm, 200mm base all as specified and directed .(iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level of size 600x600mm for casing of pole upto planting depth.(iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work above GL level. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cmas directed by Engr-in-charge. |
| 125 | Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed. |
| 126 | Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles, path to LT panels,bollard light(bollard lights to be refixed after repair to base) and other indicated work including necessary form work and finished the surface and including dismantling of old unseerviceable PCCcomplete all as specified and directed by Engr in charge. |
| 127 | M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth wire 4mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I)including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth lead includingPCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engr in charge and testing for required value in and including taking out of existing earthing complete all as specified and directed at site. Note: If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost. |
| 128 | Supply and fixing in replacement , street/security light bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts). |
| 129 | Supply & fixing MS Cross arms , bracing,supports, clamps and back plates fabricated from structuralsteel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer in and including taking down of old cross arms complete all as specified and directed by Engineer-in-charge. Note : Unexposed surface shall be given one coat of primer only. |
| 130 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means ofnut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 131 | M&L forDesign, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box,suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947 in and including providing of one No MCCB of 160 Amps, 4 Pole, 25 KA, 50 Hz 415 Volts .The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheetand 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom with angle iron legs 04 Nos of size 75x75x6mm of length 0.90 mtr and embbded in PCC. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling/taking down of old unserviceable complete. Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth). |
| 132 | Supply and fixing of nature switch smart timer based Automatic street light control panel. The panel should be suitable enough to take3 phase load of 25 KW with 3 Nos incoming-ougoing MCBs of 63 Amps & 3 nos. Contactors (2 Pole/3 pole) of 40 Amps & Circuit wiring (Copper) of 16 Sqmm. Nature switch timer smart timer should be maintannace -free in design and settings accessible via a mobile app )with bluetooth connectivity). The mobile App should allow users to customize the ON & Off timing based on nature light (Sensor), Local Sunset/Sunrise (AStro) and time.The Mobile App should also have facility to set input Voltage range. The smart timer along with suitable Power Contactors and incoming-outgoing MCBs should be enclosed in a pole/wall mountable Rust proof, electric shock proof, termite proof and FR grade SMC enclosure confirming to IP66. The circuit should also have provision for manual operartion (Sensor By pass option) & in 3 phase model, contolling current phase selection option (at least from 2 phases) . Model No : Navdeep-66-25KW3P |
| 133 | Supply and fixing of nature switch smart timer based Automatic street light control panel. The panel should be suitable enough to takesingle phase load of 10 KW withincoming-ougoing MCBs of 63 Amps and Contactors & Circuit wiring (Copper) of 16 Sqmm. Nature switch timer smart timer should be maintannace -free in design and settings accessible via a mobile app )with bluetooth connectivity). The mobile App should allow users to customize the ON & Off timing based on nature light (Sensor), Local Sunset/Sunrise (AStro) and time.The Mobile App should also have facility to set input Voltage range. The smart timer along with suitable Power Contactors and incoming-outgoing MCBs should be enclosed in a pole/wall mountable Rust proof, electric shock proof, termite proof and FR grade SMC enclosure confirming to IP66. The circuit should also have provision for manual operartion (Sensor By pass option) , contolling etc. Model No : Navdeep-66-10KW1P |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail