| 1 | Supply and fix (Geyser) Water heater storage type capacity of 25 Litersvertical type wall mounted including 15/16 Amps plug topwith suitable wall supports and for manual operation,digital temperature display, feather touch buttons, built in thermostat, auto shut off, powder coated single line weld containerwith PUF insulation,heating element capacity of 2 KW, voltage rating 230 Volt, frequency 50 Hz, 5 star rated with and including steel braided connecting hoses of required length for Hot and cold water pipe, connectingto CPVC and GI pipe complete all as specified and directed.Make: Havells/Jaquar(MET-WHT-V025)/Crompton/Racold.Note :- (i) The rates are inclusive of all the minor spares (Fasteners, Clamps, Nut bolts washers etc) required for making the geyser fully functional.(ii)The rates are inclusive of charges of OEM of the geyser who has to visit the site and brief the user about the functioning of the water Heater. (iii)The rates are inclusive of any civil work involved in installation of Geysers. |
| 2 | Supply and fix Hot water pillar taps 15 mm bore cast copper alloy with capstan heads, chromium plated, screwed down high pressure with lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 3 | Supply and fix Stop Valves , cast copper alloy, screwed down , high pressure with crutch or butter fly handle , screwed both ends for iron pipe or for unions and fixed of size 15 mm complete all as specified and directed. |
| 4 | Supply& laying pipe galvanised medium grade of 15mm dia class including all fitting (such as bends, elbows, tees required for reduce size as per site requirment, short pieces, connectors, back-nuts, diminishing pieces, caps, plugs and unions, etc) and fixing complete with clips, wall hooks, wooden plug, or laying in trenches or fixed to wall /floor/roofincluding cutting screwing etc, complete all as specified and directed. |
| 5 | Supply and fix Exhaust fan steel body AC single phase, 230 volts of size 380 mm sweep with blades and frame and louvers complete all as specified and directed.Make: Havells/Crompton/USHA/Polycab.Note : (i) To be Fixed in Existing Kitchen window (ii) The rates are inclusive of any civil work required to fix the exhaust fan on walls/window. (iii) The rates are inclusive of making holes on wall for exhaust fans. |
| 6 | Supply and fix Exhaust fan steel body AC single phase, 230 volts of size 300 mm sweep with blades and frame and louvers complete all as specified and directed.Make: Havells/Crompton/USHA/Polycab.Note : (i) To be Fixed in Existing Toilet window (ii) The rates are inclusive of any civil work required to fix the exhaust fan on walls/window. (iii) The rates are inclusive of making holes on wall for exhaust fans. |
| 7 | Material and Labour for point wiring complete with 1.5 Sqmmsingle core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor drawn through and including non metallic rigid PVC conduit and accessories in surface of walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes for provision of Modular switches to house switch/regulators etc including Modular Plate and Covers for one fan/light /bell point controlled by one switch/bell push complete all as specified and directed. |
| 8 | All as per Item No 7 here-in-before but with 4.0 SqmmPVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathedcopper conductor FRLS cable 1100Volts grade and 2.5 sqmm asearth continuity conductorfor power socket(geyser point)on independent board complete all as specified and directed. (for Geyeser) |
| 9 | Supply and fixmodular switch 1 way 6A 1 module complete all as specified and directed. |
| 10 | Supply and fix industrial wall mounted plug socket suitable fotr IP 44 degree of protection of 20Amps rating 1P+N +E complete all as specified and directed.Make: L&T/C&S/Legrand/Indoasian |
| 11 | Supply and fixingminiature circuit breaker (MCB) of rating40 Amps , 240 volts 10 KA , \"C\" curve in the existing MCB DB Complete with connection testing and commissioning complete all as specified and directed.MakeL &T /Legrand/Havells |
| 12 | Taking down unserviceable submain wiring and Material and Labour for submain wiring in and including PVC conduit with two runs of 6 sq mm and one runs of 6 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLS grade copper conductor cable single core multistranded ISI marked (IS 694) drawn through and including 25 mm dia PVC rigid conduit heavy grade ISI marked (IS 9537 Part III) includung accessories such as bends, supports etc all as specified and directed. Note: Two runs of 6 sq mm and one runs of 6 sqmm cable along with conduit shall be measured as one length complete all as specified and directed.. |
| 13 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core (Cable to be laid from nearest LT Panel to TPN DB/Metering panel)complete all as specified and directed. |
| 14 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 15 | Ditto item no 2 but in hard/dense soil. |
| 16 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding1.5 mtr above the starting point complete all as specified and directed |
| 17 | Returning filling in,including spreading, levelling watering and well ramming in layers not exceeding25cm in soft/loose soil complete all as specified and directed. |
| 18 | Material and Labour for riddled earth forcushioning to under ground electric cable including spreading, levelling and hand punning complete all as specified and directed.Note - Punned thickness shall only be measured & paid . |
| 19 | Material and Labour for road cutting/foot path and making good with PCC 1:3:6 TYPE C-2 (using 40 mm graded stone aggregate) of 150 mm width/depth complete all as specified and directed. |
| 20 | Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mmfor Under ground cable complete all as specified and directed. |
| 21 | Supply and laying GI tubes light grade, galvanized, 40 mm borein repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable complete all as specified and directed. |
| 22 | Supply and Fix BLDC Ceiling fan 1200mm sweep with regulator (modular type), colour white complete with fan blades, 300mm long down rods and accessories, 230volts Min air delivery 215 CMM and service value 6.00 BEE with ISI marked. Five star rated, Plasma BST R type complete all as specified and directed.MAKE:- Halonix/ Usha/Havells/CromptonNote :- The rates are inclusive of 300mm long down rod |
| 23 | Supply and Fix BLDC Ceiling fan 1200mm sweep with remote and batteries, colour white complete with fan blades, 300mm long down rods and accessories, 230 V. Min air delivery 220 CMM and service value 6.00 BEE with ISI marked. Five star rated, Plasma type complete all as specified and directed.MAKE:- Halonix/ Usha/Havells/CromptonNote :- The rates are inclusive of 300mm long down rod, remote with batteries |
| 24 | Supply and Fix BLDC Ceiling fan 1200mm sweep with regulator, colour white complete with fan blades, 450mm long down rods and accessories, 230 V. Min air delivery 215 CMM and service value 6.00 BEE with ISI marked. Five star rated, Plasma BST R type complete all as specified and directed.MAKE:- Halonix/ Usha/Havells/CromptonNote :- The rates are inclusive of 450mm long down rod |