| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 2 | Dismantling of timber scantling fillets, rails, posts rafters, purlins etc under 40 Sqcm, in any position as in unframed work complete all as specified and directed by the Engg-in-Charge. |
| 3 | S&F second clas soft wood fillets square or rectangular in section sectional area exceeding 13 sq cm and n exc 25 sq cm as in scantling secured with nails or breads complete all as specified and directed by the Engg-in-Charge. |
| 4 | S&F second class softwood fillets square, rectangular or triangular in section sectional area not exceeding 3 sqcm , clean sawn, secured with nails or brads bullnosed, splayed, chamfered or rounded on one edge or face as in cover fillets complete all as specified and directed by the Engg-in-Charge. |
| 5 | S&F second class softwood moulding as in cornices, picture rails and the like sectional area not exceeding 6 Sqcm fixed with nails complete all as specified and directed by the Engg-in-Charge. |
| 6 | S&F 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in walls complete all as specified and directed by the Engg-in-Charge. |
| 7 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work in ceiling or sloping portion complete all as specified and directed by the Engg-in-Charge. |
| 8 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by the Engg-in-Charge. |
| 9 | M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 20mm thick screed bedin CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 10 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete incl 15mm thick renderingin CM 1:4 complete all as specified and directed |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by the Engg-in-Charge. |
| 12 | M&L for coloured glazed ceremic tiles in vertical surfaces 450X 300X 7mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15mm thick rendering in CM (1:4) complete all as specified and directed by the Engg-in-Charge. |
| 13 | M&L for coloured non-skid ceramic tiles 7 to 8mm thick ( square / rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set andset and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15 thick screed bed in CM ( 1:6) complete all as specified and directed by the Engg-in-Charge. |
| 14 | M&L for 25 mm thick PCC 1:2:4. type B-0 (using 12.5 mm graded aggregate) as subbase to flooring or similar works complete all as specified and directed by the Engg-in-Charge. |
| 15 | M&L for 75 mm thick PCC 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection and subbase to floors complete all as specified and directed by the Engg-in-Charge. |
| 16 | Demolition ofconcrete of any (unreinforced) description and in anypositionand removal of rocks/debris to a distance not exc 50 mtrs and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by the Engg-in-Charge. |
| 17 | Demolition of precast concrete articles andprecast concrete block walling including allquoins, arches, pillars, etc built in cement mortar of any description not other specifically provided for etc complete all as specified and directed by the Engg-in-Charge. |
| 18 | M&L for Precast cement concrete type C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by the Engg-in-Charge. |
| 19 | Taking down cement plaster or any description including raking outjoints, hacking for key, scrubbing down with water etc and removal of debris to a distance not exc 50 mts and depositing where directed complete all as specified and directed by the Engg-in-Charge. |
| 20 | M&L for rendering 15mm thick cement plaster in cement mortor (1:4) finished even & fair withoutusing extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge. |
| 21 | M&L rendering 15mm thick cement plaster in cement mortor (1:6) finished even & smooth withoutusing extra cement on brick/concrete surfaces complete all as specified and directed by the Engg-in-Charge. |
| 22 | M&L for two coats of Oil bound distemperon new plastered surfaces of wallsover one coat of primerincludingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 23 | M&L for two coats of cement based paint on newly plastered surfaces of walls overone coat of primer includingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 24 | M&L for two coats of cement based paint on old plastered surfaces of wallsincludingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 25 | M&L for two coats of Oil bound distemperon old plastered surfaces of wallsincludingpreparation of surfaces complete all as specified and directed by the Engg-in-Charge. |
| 26 | S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified and directed by the Engg-in-Charge. |
| 27 | M&L for preparing old wooden surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge. |
| 28 | M&L for preparing old steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engg-in-Charge. |
| 29 | S&F in repair curtain rails anodised aluminium alloy chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by the Engg-in-Charge. |
| 30 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed by the Engg-in-Charge. |
| 31 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc 0.5 Sqm in each pane complete all as specified and directed by the Engg-in-Charge. |
| 32 | Demolition ofcement concrete (reinforced) of any description and in anyposition complete all as specified and directed by the Engg-in-Charge. |
| 33 | M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed by the Engg-in-Charge. |
| 34 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engg-in-Charge. |
| 35 | M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as infoundations, mass filling , sub base and the like complete all as specified and directed by the Engg-in-Charge. |
| 36 | M&L PCC (1:2:4) type B-2 using 40mm graded stone aggregate as insurface channels and drains complete all as specified and directed by the Engg-in-Charge. |
| 37 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 38 | Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 25 mm dia pipes complete all as specified and directed by the Engg-in-Charge. |
| 39 | S&F 20mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UVstabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed by the Engg-in-Charge. |
| 40 | All as per Srl item No.39 above but 25mm outer diameter complete all as specified and directed by the Engg-in-Charge. |
| 41 | S&F in repair 15 mm bore bib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 42 | S&F in repair Vitreous china wash down water closet pan orissa pattern size 580x440mm (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 43 | S&F in repairs 10 ltrs capacityPVCvalveless syphonic action typelow level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed by the Engg-in-Charge. |
| 44 | S&F in repair 15mm bore PVC connection 600mm long both ends screwed with brass cap complete all as specified and directed by the Engg-in-Charge. |
| 45 | S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by the Engg-in-Charge. |
| 46 | S&F in repairs 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by the Engg-in-Charge. |
| 47 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by the Engg-in-Charge. |
| 48 | Taking down PVC pipe, eaves and gutters(any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 49 | S&F 110 mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints,laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 50 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 51 | S&F 110 mm bore PVC (SWR)bends with oval access doorany radius complete all as specified and directed by the Engg-in-Charge. |
| 52 | S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 53 | S&F 75 mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed by the Engg-in-Charge. |
| 54 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal oval acess door complete all as specified and directed by the Engg-in-Charge. |
| 55 | Dismantling PVC water tanks of capacity exc 500 but n exc 1000 ltr and removing to store complete all as specified and directed by the Engg-in-Charge. |
| 56 | S&F 1000 ltr capacity rotationally moulded polythene water storage tanks (cylindrical vertical with closed top) multilayers layers of approved make hoisted & fixed at position complete all as specified and directed by the Engg-in-Charge. |
| 57 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by the Engg-in-Charge. |
| 58 | S&F in repair 15mm bore dia angle valves of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) complete all as specified and directed by the Engg-in-Charge. |
| 59 | S&F in repair 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed by the Engg-in-Charge. |
| 60 | S&F 110 mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints,fixed in walls complete all as specified and directed by the Engg-in-Charge. |
| 61 | S&F in repairs stainless steel squatting pan of pattern “long pan”, size 580 x 440 mm with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by the Engg-in-Charge. |
| 62 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by the Engg-in-Charge. |
| 63 | S&F Angle Iron and FI as in staging for water tank and the like including caps bases splices etc built up from two or more beam or channel section angle with plate including all lattice bars stiffenes gusset plate etc (Fe-410 w gde-E-250 quality A) complete all as specified and directed by the Engg-in-Charge. |
| 64 | M&L for preparing previously untreated steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over one coat of redoxide primer including preparation of surface complete all as specified and directed by the Engg-in-Charge. |
| 65 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants,sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 66 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing capingwith all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cablefor earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer pointcontrolled by one switch. |
| 67 | All as per Srl item No. 66.00 here in before but usingcable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 68 | All as per Srl item No. 66.00 here in before but usingcable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 69 | S&F Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by Engr-in-Charge. |
| 70 | S&FSwitch socket combination 2 in 1, and 3 and 2 pin, 5 Ampsflush type complete all as specified and directed by Engr-in-Charge. |
| 71 | S&F Switch socket combination 2 in 1,5 and 15 Ampsflush type complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L of ceiling rose on PVC square blocks surface bakelite 3 terminal complete all as specified and directed by Engr-in-Charge. |
| 73 | S&F in replacement LED lights fitting 18/20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge. |
| 74 | S&F in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. |
| 75 | S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300mm complete all as specified and directed by Engr-in-Charge. |
| 76 | S&Fin replacement 440 V, 10 KA C curve miniature circuit breaker (MCB) TPN 40 to 100 Amp in the MCB DB complete with connection testing and complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F in replacement Sheet metal enclosure for DB\"s (TPN BD) Double door,triple pole and neutral, 440V, 4 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by Engr-in-Charge. |
| 80 | S&F in replacement Sheet metal enclosure for DB\"s Double door,single pole and neutral, 240V, 4 way with 200 Amp rated bus bar including blanking plates where required complete all as specified and directed by Engr-in-Charge. |
| 81 | S&F in replacement 240V, 10KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F in replacement 240V, 10KA C curve miniature circuit breaker (MCB) SPN 32 Amp in the MCB DB complete with connection testing complete all as specified and directed by Engr-in-Charge. |
| 83 | S&F in replacement 240V, 10KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing complete all as specified and directed by Engr-in-Charge. |
| 84 | S&F LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge. |
| 85 | M&L for Submain wiring comprising single core, 2 Runs of 6.0 Sqmm nominal cross sectional area multi stranded FRLS copper coonductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 25mm dia. PVC conduit/ PVC Casing CapingISI Marked (heavy duty) and its fittings on surface/recessed complete including 1x6.0 Sqmm nominal cross sectional area mutli stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS including taking down UNSV submain wiring and making good the disturbed surface complete all as specified and directed by Engr-in-charge. (Note: Extra length of cables/ wire required for connection to MCBs shall not be paid seperately and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 86 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm×6.0mmthick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipment, including watering arrangement with GI medium grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber CI cover with frame including 15mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata, returning, filling, removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified or indicated including testing on completion.Notes : (i) Earth continuity conductor including protection pipe upto 7.5 meters from earth electrode will be include in unit rate,(ii) Arrangement for earth resistance test should be carried out by the contractor. No extra payment shall be provided for the same. |
| 87 | S&Fin replacement1100 volts grade heavy duty 16 Sqmm 2 core flat cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 88 | Supply, laying, fixing and testing of cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 50 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments), laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles including taking down of existing cable complete all as specified and directed by Engr-in-Charge. |
| 89 | S&F GI tubing light grade 40 mm bore as in cable protection fixed to poles/walls or laid in trenches/under road crossing etc complete all as specified and directed by Engr-in-Charge. |
| 90 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard / dense soil for taking out cable & laying of cable complete all as specified and directed by Engr-in-Charge. |
| 91 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 92 | Returning filling, including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified and directed by Engr-in-Charge. |
| 93 | Supply & laying of DWC (Double Wall Corrugated) duct pipe (HDPE) of size 90 x 76 mm laid in trench/ducts/under roads/under hard standing/along poles complete all as specified and directed by Engr-in-Charge. |
| 94 | S&Fin replacement 1100 volts grade heavy duty 10 Sqmm 2 core flat cable PVC insulated aluminium standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-in-Charge. |
| 95 | Note : Deduction for amount of Rs. 83,396.20 as listed in Schedule \"A\" Part-II (Schedule of Credit) shall be made while awarding of contract. |