| 1 | Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical liftwith power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door cills, door locks, cabin lights, minor repair of cabin fan,control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked /broken and MS parts,door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator,and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC cardof stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement and ensure smooth and safe operation of lifts ,fixing of loose rail bracket with necessary masonry work , changing of broken anti skid pvc rubber matandair freshner at lift cabin, removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfacesand liftmachine and all equipmentheld in machine roomand rust painting at car top and door and allied parts , two coats of painting of gear motor, all MS channels and Control Panels using spray gun ensure safe and smooth functioning of liftand complete maint of car top, binding of loose wire at control panel and , dewatering of lift wells in case of any emergency arise complete all as specified and directed.Hospital Buildings : 10 passenger lift capacity for lift No. 01,03,06, 15 ( Total = 04 Nos lift) .Make: ExIsiting make at Bldg . |
| 2 | All as per item No1 herein before but 16 passenger lift, lift No. 04,07,08, 11,12 ( Total = 05 Nos lift)at Hospital Buildings : .Make: ExIsiting make at Bldg . |
| 3 | All as per item No1 herein before but 20 passenger lift,lift No. 05,14 ( Total = 02 Nos lift)at Hospital Buildings : .Make: ExIsiting make at Bldg . |
| 4 | All as per item No1 herein before but 20 passenger lift, lift No. 02,13 ( Total = 02 Nos lift)at Hospital Buildings : .Make: ExIsiting make at Bldg . |
| 5 | All as per item No1 herein before but 1000/500Kg goodslift,lift No. 09,10 ( Total = 02 Nos lift)at Hospital Buildings .Make: ExIsiting make at Bldg . |
| 6 | All as per item No1 herein before but (544 Kgs) lift No. 01, (01 Nos lifts) at SOMA Building Make: ExIsiting make at Bldg . |
| 7 | All as per item No1 herein before but (1020 Kgs) lift No. 02, (01 Nos lifts) at SOMA Building Make: ExIsiting make at Bldg . |
| 8 | Note :- for Item No 01 to 07, (i) The Contractor has to carry out the AMC of the Lifts through OEM only.(ii) The AMC should cover any / all parts of Lifts if its functions found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms.(iii) One mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift.(iv) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department.(v) The detailed lift mechanics shall sign (Their shift wise) in the attendance register kept with lift cell. If he is found absent of move without intimating to incharge of lift cell of JE EM, he will be treated as absent for this said shift recovery to this effect for Rs 1500/- per shift shall be affected.(vi) Cost of minor spare parts/ routine material required for above mentioned maintenance is deemed to be included in the quoted rate except items mentioned here-in-after. No additional cost of spares is admissible for the above maintenance. Decision of the Accepting Officer shall be final & binding regarding minor spares/ routine material.(vii) Monthly schedule for proper maintenance of lift and necessary documentation including all spares parts required to be replaced during the period shall be as directed .(viii) All minor spare parts and parts required for repair/ replacement for maintenance of lifts to be replaced during AMC at no extra payment. |
| 9 | Dismantling and taking out existing unserviceable main control panel from machine room including wiringand supply & fix new factory made control panel dust and vermin proof using 1.5 mm thick powder coated MS sheet with suitable locking arrangement for simple, collective and selective operation using multiple microprocessor, logic crads Main bords PCBs relays, indicator lamp, protection, controls with all connected electric& electronic componets suitable for all lifts capacity mentioned in complete all as specified and directed. |
| 10 | Replacement of unserviceable travelling cable from hoist way, supply & fix new travelling cable PVC insulated 16 core with standard copper conductor 1100 volts grade of size 0.75 Sqmm confirming to relevant IS including thimbles, suspended type freely move with car cabin up and down movement between ground and upper floors including necessory proper connetion with mid way junction and other connection requied in circuit complete all as per specified and directed. |
| 11 | Distmantling and taking out old unserviceable main V grooves pulley from lift, supply and fixing main pulley made CI suitable for steel rope 13 mm dia including necessory bearing bush washers, nuts, repairs to mechanical break assembly etc. of any capacity lift completee all as specified and directed. |
| 12 | Distmantling and taking out old unserviceable main VVVF unit supply and fix new main VVVF drive unit of suitable for 11 KW capacity in existing panel and connected with existing system including testing and commissioning confirming to same model with specification and same capacitycomplete for smooth and jerk free working of lift. Complete all as specified and directed. |
| 13 | Distmantling and taking out old unserviceable main control logic board and fix newsuitable for exixting capacity connected with the system including testing and commissioning, Complete all as specified and directed. |
| 14 | Supply and fixing in repairs energy efficient LED fittings 6/8 W, not less than 120 Lumen per watt of existing shape including necessory electric connections and accessories complete all as specified and directed. |
| 15 | Taking down unserviceable cabin fan from car cabin ,supply and fixing newcar cabin fan non oscilatting type axial flow single speed 300mm sweep, 240 volts ISI mark with grillcomplete all as specified anddirected. |
| 16 | Dismantling and taking outARDcontrol system and commissioning andtesting of new ARD system including PC cards/diodes suitable for upto 10 HP motor including wiring with connected item in existing building.Make: Must be suitable for exiting make at site .complete all as specified and directed. |
| 17 | Disconnecting and taking outunserviceableinfra red door sensor of any type and make, supply and fix newinfra red door sensor of up to full length of car door complete all as directed. |
| 18 | Dismantling and taking outall defective batteries from existing ARD, supply and fixing newbatteries suitable for ARD including necessaryconnection like battery terminals of brass and copperlead heavy duty to connect the battery terminal ofall as directed. |
| 19 | Dismantling and taking out unserviceable existing Stainless Steel landing door from various floors with its header, lock, brakesafety contact, MS cill etc & supply and fixing new stainless steel 18 SWG center opening by horizontalsliding stainless steel panel auto door for landing & car complete with header, cill, bracket bearing safety contact electro magnetic gate locks etc complete all as per exisiting size and design including necessary cuttinglifts opening in masonary work and making good disturbed surface complete all as specified and directed. |
| 20 | Dismantling and taking out unserviceable car door from car cabin supply and fixing new car door comprises of 02 No power operated, auto telescopic / centre opening by horizontal sliding stainless steel panel offlush type panels complete with removed headers, hangers, door drive unit with full beam infrared sensor up to full length of car door, aluminium sill VVVF door drive unit for motorcomplete with all accessories control connection etc. for for lift all as Specified and directed . |
| 21 | Dismantling exsting false ceiloing of lift & supply and fiximg stainless steel false ceing 2 mm thickness to lift car inclluding ficing new blower,LED light of suitable capacity and wiring all as specified and directed. |
| 22 | Disconnecting and taking out unseriveable hooter with emergency call anoounciater working on 12 Volts with audiability 90 DB @ 100 M distance with complete accessories like push button switches and wiring along with box including connecting cables,complete all as specified anddirected. |
| 23 | Dismantling and taking out existing unserviceable main main mother boardfrom ARD paneland supply & fix new new mother board for ARD with all connected electric & electrronic componetnts suitable for all lifts of capacity 8 passengers complet alll as specified and dircted. |
| 24 | Taking down old unserviceable COP after disconnecting old COP(G+6) supply & fixing newilluminated car operating panel in positioncomplete including all fittings andaccessoriesall as specified and directed. |
| 25 | Taking down old unserviceable LOP after disconnecting old LOP(G+6) supply & fixing new Landing operating panel in position complete including all fittings andaccessoriesall as specified and directed. |
| 26 | Replacement of existing unserviceable wiring in hoist way new shaft wiring in hoist way upto lower limit switch with PVC insulated with multistnadard copper conductor 0.75 Sqmm & 01 Sqmm for earthing, 1100 volts grade drawing through in and including galvanised sheet metal trunking (24 SWG) up to ground floor in hoist way for control of all floor control of all floor hall push button assemby, liimit switches terminal switches, fireman switches etc complete all duly earthed at all points suitable for lift complete all as specified and directed.. |