| Sl. No. | Item Description |
| 1 | Disconnecting electric connections from LT control panel and starter of submersible pump set of size 2 to 20 HP and removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back and lowering of same pump in bore well after repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing & commissioning complete all as specified and directed(Note for Item No 1 to 3 : Serviceability of pumpset after repair shall be got tested by EIC before re-installation and lowering. Each pump maintenance/functionality/serviceability will be covered for one year after satisfactory repair and if pump motor winding brunt out in the contract period or within defect liability period of one year, the same will carried out by contractor \"Free of cost\" at his own arrangement. A BOO will be ordered for checking of serviceability & functionality of pump after repair from work shop and the same will be kept on record dully signed & concurred by GE. These aspect will be considered during quoting rates per unit (Each Job) |
| 2 | Disconneting of electrical connection from the panel board, and starter of submersible sewage pump of upto 7.5 HP capacity and removing the pipe line connection from discharge side and taking out submersible pump set along with column pipe from sewage bore well of depth 50 feetwith the help of chain pully block including transportation to Workshopand back after repair or cleaning the suction side with impeller of pump set by removing sludge, blockage, polythene and other foreign materialand lowering of same pumping bore well including replacement of rusted nuts bolts rubber gasket etc to make it fully functional complete all as specified and directed by Engr-in-Charge. |
| 3 | Opening the submersible pump set / sewage pump set of capacity 2.00 to 20.00 HP including taking down/out the burnt winding wire cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge, weight etc, repairing the same by replacing the unserviceable parts including machine/ lathe work and re-assembling the pump set in original position with required insulating material to make it fully functional complete all as specified and as directed by Engr-in-Charge.(Note:- (i) Super enamelled copper winding wire obtained after dismantling shall be contractor\"s property and accordingly rate will quote under item No (4) below.(ii) Inventory of workshop for repair of pump shall be kept on record duly signed by EIC & JE (E/M). |
| 4 | Supplying and assembling super enamelled copper winding wire of appropriat gauge and weight suitable up to 20HP pumping sets complete all as specified and directed by Engr-in-Charge.(Note:- Labour element shall be deemed included in quoted unit rate of item No (3) above.) |
| 5 | Supply and fixing of following items capacity 2-20 HP submersible pump set after taking down/out as existing at site complete all as specified ans as directed:-(Note:- Old unserviceable parts of pump set shall be taken on charge in scrap in \"KG\" under demolition ledger). |
| 6 | G M Bearing Bush. |
| 7 | Rotor Sleeve. |
| 8 | Water seal and cable seal |
| 9 | Thrust bearing sagment |
| 10 | Revolving Disc |
| 11 | CI Connection piece |
| 12 | Sand Guard |
| 13 | Sealing Ring |
| 14 | CI upper Housing |
| 15 | CI lower Housing |
| 16 | Rotor Sleeve turning and grinding |
| 17 | Remetling of Rotor end turning and making key way |
| 18 | Flange upper with stud and nut |
| 19 | Flange lower with stud and nut |
| 20 | Repairing of stamping for motor |
| 21 | Seal bush |
| 22 | Thrust plate |
| 23 | SS coupling |
| 24 | Stud and Nuts for connection piece |
| 25 | Balancing of rotor |
| 26 | T Bolt with Nut |
| 27 | LNK Bolt SS |
| 28 | Submersible Cable joint |
| 29 | CI Suction Chamber |
| 30 | CI Stage bowl |
| 31 | G.M Impeller |
| 32 | EPV Impeller |
| 33 | EPV Stage Bowl |
| 34 | GuideBush |
| 35 | GM DOWL Bush |
| 36 | SS DOWL Sleeve |
| 37 | Inter ring |
| 38 | CI DOWL Piece |
| 39 | CI NRV body |
| 40 | Impeller key |
| 41 | SS pump shaft single stage |
| 42 | Rematling of GM Impeller and Turning |
| 43 | SS Distance Sleeve |
| 44 | Pump sand guard |
| 45 | Hook bolt with nut |
| 46 | GM NeckRing |
| 47 | Mild steel stud with nut |
| 48 | Wire mesh |
| 49 | Drain plug |
| 50 | EPV Defuser |
| 51 | M&L for preparation of surfaces for painting of existing submersible pump sets of capacity 2 to 20 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. |
| 52 | M&L for replacement of heavy duty GI Nipple 300mm long with 80mm bore with flange welded on both ends complete all as specified and as directed. |
| 53 | M&L for replacement of heavy duty GI Nipple 300mm long with 50mm bore with flange welded on both ends complete all as specified and as directed. (Note for ser item No 7 & 8 :- Old U/s GI nipple obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV ofweight (KG) shall be taken into account and attach with RAR/F Bill) |
| 54 | Supply and fixing water proof submersible cable3 core copper conductor, PVC insulated 1100 volts grade, protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed at site by the Engr-in-Charge of the following sizes:- (Note:-Old U/s copper cable obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV ofweight (KG) shall be taken into account and attach with RAR/F Bill). |
| 55 | 1.5 Sqmm |
| 56 | 2.5 Sqmm |
| 57 | 4 Sqmm |
| 58 | 6 sqmm |
| 59 | 10 Sqmm |
| 60 | Material and labour for pin point the fault by arranging fault locating machine in any size of LT UG cable from any location/position/situtation, taking down/out the faulty portion of cable, of any length from trenches, jointing with cable jointing kit & testing for satisfactorily serviceable with & including necessary excavation and earth work, sand cushioning and making necessary connections to make it functional complete all as specified and as directed.Note :- (i) Cable jointing kit shall be measured and paid seperetely.(ii) Old retrieved bricks/cable cover shall be reused(iii) The rates quoted includes excavation & earth work with sand cushioning. |
| 61 | M&L for cable joint kit of size 3.5 core 35 sqmm for heat shrinkable straight through joint complete all as specified and directed |
| 62 | M&L for cable joint kit of size 3.5 core 50 sqmm for heat shrinkable straight through joint complete all as specified and directed |
| 63 | M&L for cable joint kit of size 3.5 core 70 sqmm for heat shrinkable straight through joint complete all as specified and directed |
| 64 | M&L for cable joint kit of size 3.5 core 95 sqmm for heat shrinkable straight through joint complete all as specified and directed |
| 65 | Labour only to remove submersible pump set upto 25 Hp capacity from dry/dead borewell including removal of column pipes/cables and transportaion charges, to kept in MES store yard complete all as specified and directed by Engr-in Charge. |
| 66 | Supply and fixing GI column pipe heavy grade, 80 mm bore 3 mtrs long coupled with heavy grade suitable size of MS flanges 16mm thick duly welded on both sides as directed including necessary nut and bolts with washers & rubber packing required at site condition and lowered in to the bore well including taking out old unserviceable Column pipe complete all as specified and directed by Engr-in-Charge (length of each column pipe shall be 3 Mtrs) (Note : - (i) Taking out and Lowering of Submersible pump set shall be measured and paid under respective item.(ii) Old column pipe shall be deposited to MES store yard. |
| 67 | Supply and fixingGI column pipe heavy grade, 50 mm bore 3 mtrs long coupled with heavy grade suitable size of MS flanges 16mm thick duly welded on both sides as directed including necessary nut and bolts with washers & rubber packing required at site condition and lowered in to the bore well including taking out old unserviceable Column pipe complete all as specified and directed by Engr-in-Charge (length of each column pipe shall be 3 Mtrs) (Note : - (i) Taking out and Lowering of Submersible pump set shall be measured and paid under respective item.(ii) Old GI column pipe shall be deposited to MES store yard). |
| 68 | Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 50mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 50mm dia column pipe complete all as specified and directed. |
| 69 | Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 80 mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 80mm dia column pipe complete all as specified and directed.(Note for ser Item No 18 to 19:- Old U/s material clamps obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 70 | Supply and fixing well cap suitable for 200 to300 mmbore pipe consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricatedout of mild steel sheet 1.5 mm thick complete all as specified and directed by Engr-in-Charge. |
| 71 | Supply and packing pea gravel of size 3mm to 6 mm around casing / housing pipe complete all as specified and directed by Engr-in-Charge.(Note:- Stack measurement of pea gravel shall be entered in MB for payment purpose after reduction of voids in volume). |
| 72 | M&L for brick workwith sub class \"B\" bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) complete including demolition of existing brick work all as specified and as directed at site by the Engr-in-Charge.(Note:- Old U/s material brick / bats obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in volume (CUM) shall be taken into account and attach with RAR/F Bill) |
| 73 | M&L PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, flooring sub base including demolition of existing PCC complete all as specified and as directed at site by the Engr-in-Charge.(Note:- Old existing demolished PCC including rubbish shall be removed by contractor outside MOD land as directed by EIC at his own arrangement.) |
| 74 | M&L for Earthing complete with GI earth plate electrode 60 cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than2.25 mtr below ground level with top edge of the earth plate at a depth not less less than 1.6 mtr below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and salt and common salt filling in alternater layers and also connected by using GI strip 25 x 4 mm by means of bolts, nuts, check nuts & washers of galvanised iron and protected by light grade 40 mm dia GI pipe connected to main switch board of main control board and GI pipe light grade 20 mm dia for watering and including funnel, wire mesh, RCC pit cover by providing steel TMT bars 8mm dia @ 100mm center to centerspacing both side at top & bottom and PCC chamber pit with PCC 1:2:4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in elecrical plate No.3 of SSR Part 1 complete all as specified and directed.(Note:- Excavation & earthwork of pit and GI tubing, GI strip upto 7.5 RM from test point shall be deemed included in quopted unit rate.) |
| 75 | Development of bore well if any capacity size, not more than 150mtrs deep, at the pressure not less than 6 Kg/Sqcm by disel engine driven air compressor of capacity 450cfm with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well complete all as specified and as directed |
| 76 | Development of bore well, if any capacity size, not more than 160mtrs deep, at the pressure not less than 6 Kg/Sqcm by disel engine driven air compressor of capacity 630cfm with & including air pipe and connected items to achieve the minimum yield of 3 litres per second of tube well complete all as specified and as directed.for Item No 25 & 26 :- (i) Log sheet for development hours with showing machine number of compressor and time of development of bore by start and end time be mentioned in log sheet duly signed by JE E/M & EIC shall be kept in record.(ii) Cost of Diesel & driver with compressor machine & transporation shall be deemed included in quoted unit rate.) |
| 77 | Supply and fixing in replacement of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed |
| 78 | Supply and fixing in replacement of rubber packing suitable for flange 50mm dia complete all as specified and as directed |
| 79 | Supply and fixing in replacement of rubber packing suitable for flange 80mm dia complete all as specified and as directed |
| 80 | Supply and fixing in replacement of rubber packing suitable for flange 100mm dia complete all as specified and as directed |
| 81 | Supply and fixing in replacement Amp meteras per existingmodel up to 50 Amps. |
| 82 | Supply and fixing in repair of analog timer switch dial type 24 hours up to 25 Amps(Note for ser Item No 27 to 32:- Old U/s material Mild steel scrap / PVC obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 83 | Taking down old unserviceable any type of starterany size and supply and fixing new ML 1.5 FASD with ML relay range 13-21 Amps including stainless steel box copper lugs existing starter panel complete all as specified and directed |
| 84 | Taking down old unserviceable any type of starterany size and supply and fixing new ML 2 FASD with ML relayrange 20 - 32 Amps including stainless steel box copper lugs existing starter panel complete all as specified and directed |
| 85 | Supply and fixingpower contactor MNX-18, 32 Amps, 240 volts, 50 HZ including NO-N Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 86 | Supply and fixingpower contactor MNX-25, 45 Amps, 240 volts, 50 HZ including NO-N Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 87 | Supply and fixingpower contactor MNX-32, 55 Amps, 240 volts, 50 HZ including NO-N Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed. |
| 88 | Supply and fixingpower contactor MNX-40, 55 Amps, 240 volts, 50 HZ NO-N Nozzle suitable for fixing in existing panel after taking down/out contactor as existing at site complete all as specified and as directed.(Note for Item No 33 to 38:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 89 | Material and labour 6 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required in replacement complete all as specified and directed |
| 90 | Material and labour 10 Sqmm PVC insulated copper conductor, single core cable in surface/ recessed as required in replacement complete all as specified and directed.(Note for Item No 39 to 40:- Old U/s material Copper Cable obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 91 | Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS: 9523 including taking down existing complete all as specified and directed by Engr-in-Charge.(Note:- Old U/s material CI/DI fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 92 | Upto 100 mm bore |
| 93 | Upto 150 mm bore |
| 94 | Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class \"C\") laid in trenches or on floors for connections to centrifugal/Submersible pump sets for suction, delivery pump to header and to connect out going water main CI/DI pipe line including taking down exiting MS Pipe all as directed by Engr-in-Charge.Note:- (i) MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately. (ii) Old U/s material MS Pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 95 | 100 mm bore |
| 96 | 80 mm bore |
| 97 | Supply& Fixing in replacement MS Flange of following sizes, 16 mm thick, duly welded on ends of MS pipe including necessary cutting to existing MS pipe or in new MS pipe with flange joint including nuts, bolts, washers and rubber gaskets complete all as specified and as directed:-(Note:-Old unserviceable MS Flange shall be taken on charge and enter in demolition / salvage register in \"EACH\" and attach the same page of salvage register with each RAR.) |
| 98 | 80 mm |
| 99 | 100 mm |
| 100 | 150 mm |
| 101 | Taking down the unserviceable terminal block any type and supply and fixing new one terminal block 100A - 3 way (For MU-G30/50) complete all as specified and directed |
| 102 | Taking down old unserviceable any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 100Amps 4 Pole on existing pole/wall complete all as specified and directed |
| 103 | Taking down old UNSV any type changeover switch and S&F Off-load changeover switches 415V, 50 Hz 200 Amps 4 Pole on existing pole/wall complete all as specified and directed |
| 104 | Taking down old unsv relays and supply and fixing new thermal over loadrelays fixing at existing site complete all as specified and as directed. |
| 105 | ML 1.5 relay range 6-10 Am |
| 106 | ML 1.5 relay range 10-16 Amp |
| 107 | ML -2/3 relay range 9-14 Amp |
| 108 | ML-2/3 relay range 13-21 Amp |
| 109 | ML-2/3 relay range 14-23 Amp |
| 110 | ML -2/3 relay range 20-32 Amp |
| 111 | ML -2/3 relay range 28-42 Amp |
| 112 | Supply and fixingsingle phase preventor, type VSP-II after taking down/out preventor as existing at site complete all as specified and as directed . |
| 113 | Supply and fixing submersible pump controller starter in sheet metal enclosure with volt meter and ampere meter, motor rating 415 Volts, 3 phase, 50 Hz for 7.5 HP motor after taking down/out breaker as existing at site complete all as specified and as directed |
| 114 | Supply and fixing MCB 6-32 amps, 230 volts \"C\" series single pole in the existing MCB DB including removing existing unserviceable MCB\"s complete all as specified and as directed |
| 115 | Supply and fixing MCB 4 pole 63 Amps, 415volts TPN in the existing MCB DBincluding removing existing unserviceable MCB\"s complete all as specified and as directed |
| 116 | Supply and fixing in repairs MCCB 63 Amps 18 KA, 3 Pole including studs in existing LT panel fixing complete all as specified and directed |
| 117 | Supply and fixing in repairs MCCB 100 Amps 25 KA, 3 Pole including studs in existing LT panel fixing complete all as specified and directed. |
| 118 | Supply and fixing in repairs MCCB 40 Amps 18 KA, 3 Pole including studs in existing LT panel fixing complete all as specified and directed.(Note for Item No 44 to 54 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 119 | Drilling 250 mm (10\") bore hole by DTH type method at any depth below soil/rock including disposal of surplus soil to a distance n.exc. 50 mtr complete all as specified and directed.Note:-(i) The depth of drilling bore shall be upto water table and will be directed by Engr-in-charge (ii) The rates quoted in above items is deemed to be inclusive of all T&P equipments and labour required for execution of this item at site including trasportation charge for the said T&P equipments and no extra cost shall be paid for the same. (iii) Depth of drilling of bore hole shall be as per site as directed by EIC. In any case Govt approval of bore holes required beyond 30RM depth shall be arranged by contractor at his own cost from CGWB. Quoted rate shall be deemed included for this aspect.(iv) A BOO ordered concurred by GE for requirement of drilling bore, holes for tubewell to provide extra water on urgent necessity basis under a maint contract and the sme shall be kept on record.) |
| 120 | Supplying, laying, jointing, welding & testing MS Pipe of size 200 mm (Heavy duty class \"C\") 8 mm thick laid in trenches for complete all as specified and directed by Engr-in-Charge. |
| 121 | Supplying, laying, jointing, welding & testing MS Pipe of size 200 mm (Heavy duty class \"C\") 8 mm thick laid in trenches or on floors having 3mm slots in 2.44 to 3.85 mtr lengthfor complete all as specified and directed by Engr-in-Charge. |
| 122 | Supply and laying LT UG XLPE insulated armoured heavy duty electric, power cable with aluminium conductor, 1100 volts grade laid in trenches, fixed to poles etccable including taking down old unsv cable of the following size:- (Note:- Old U/s material XLPE Cable obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 123 | 3.5 Core 16 Sqmm |
| 124 | 3.5 Core 35 Sqmm |
| 125 | 3.5 Core 50 Sqmm |
| 126 | 3.5 Core 70 Sqmm |
| 127 | Excavation in trenches not exc.1.5m wide and not exc. 1.5m in depth including getting out in soft/loose/ Hard soil complete all as specified and directed. |
| 128 | Retuning filling in including spreading, levelling, watering and well ramming in layers not exc. 25Cms complete all as specified and directed. |
| 129 | Removing excavated materials and depositing to a distancenot exc 50m where directed at a level not exc 1.5m above from starting point complete all as specified and directed. |
| 130 | M&L burnt brick sub class \"B\" old size laid in trenches with equal to length of bricks across the cable protection complete all as specified and as directed. |
| 131 | Supply and spread clean dry river sand to required width at bottom and top for cable cushioning complete all as specified and as directed.(Note:- Punned depth of sand only shall be mesured and paid.) |
| 132 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.(Note:- Old U/s material Point wiring material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 133 | Material and labour for point wiring 1.5 Sqmm PVC insulated and unsheathed cable with copper conductor 1100 Volts grade, multistranded alongwith earth wire in existing concealed/ surface / recessed steel including 20mmPVC conduits with PVC insulated FRLS copper wire complete all as specified and directed. |
| 134 | Material and labour for point wiring 2.5 Sqmm PVC insulated and unsheathed cable with copper conductor 1100 Volts grade, multistranded alongwith earth wire in existing concealed/ surface / recessed steel including 20mmPVC conduits with PVC insulated FRLS copper complete all as specified and directed. |
| 135 | Supply and fixing MCB DB SPN double door 8 way vertical type comprising the following accessories enclosed in a sheet metal enclosure including taking down old unsv DBs.(i) MCB SPN 63 amps - 01 No. for incoming (ii) MCB SP 6-32 amps - 06 Nos for outgoing.(Note:- Old U/s material MCB obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in scrap in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 136 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with nut & bolts impact and corrosion resistant including 1.5 sqmm three core copper cable from fitting to junction box thermal management in multiple optics complete with IP 65/66 protection fixing on pole/building complete including taking down old unsv complete all as specified and as directed |
| 137 | Supply and fixing LED street light fitting 50 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with nut & bolts impact and corrosion resistant including 1.5 sqmm three core copper cable from fitting to junction box thermal management in multiple optics complete with IP 65/66 protection fixing on pole/building complete including taking down old unsv complete all as specified and as directed.(Note for Item no 68 & 69:- Old U/s material LED fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 138 | Supply and fixing in repair Automatic Phase Sequence Correctorsuitable for 2-20 HP with sheet metal encloser and indicator lamp output/inpurt, suitable for 3 phase electric motor with automatically protection against single phasing voltage, unbalanced and low/high voltage with time delay complete all as specified and as directed |
| 139 | Supply and fixing direct on line starters in sheet steel enclosure type MN/ML (motor rating AC-3 duty, 415V, 50 Hz, 3 Phase up to 10 HP including taking down old unsv starter complete all as specified and as directed |
| 140 | Supply and fixing electronic Timers Type ST 100 240/360/415 V, 50 Hz for 3-30 secs [9107] including taking down old unsv any type timer complete all as specified and as directed.(Note for Item No 70 to 72 :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 141 | Supply, layingjointing, testingand commisioning DIpipe 100mm dia with tyton joint as per IS 8329 class-K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work complete all as specified and directed by Engineer-in-Charge.(Note : Earth work shall be measured and paid separetely. |
| 142 | Supply & fixing in replacement,testing and feeder pillar box in outdoor type cubical shape, three phase, 4 wire, Aluminium bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron, 2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar, switch gear & danger Notice plate of size 300x200mmx3mm thick marked skull & bones with highlightend flourescent glow paint etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:- |
| 143 | (i) Aluminiumbus bar with PVC sleeve suitable for 200 amps for phase & 200 Amp for neutral- 01Set. |
| 144 | (ii) Voltmeter,digital type 0- 500 volt,with selector switch - 01 set |
| 145 | (iii) Ammeter Digital type 0-100Amps, with selector switch and CT\"-1set |
| 146 | (iv) Phase indicating lamps LED type ( red , yellow, blue) 01 set |
| 147 | (v) Incoming MCCB 63 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No |
| 148 | (vi) Outgoing MCCB40 Amp 3-Pole 18 KA with adjustable thermal and fixed magnetic release - 01 No |
| 149 | (vii) FASD StarterML 1.5 FASD with MS sheet enclosure-01 No |
| 150 | (viii) Analog time switch -01 No |
| 151 | (ix) Single phase preventer-01 No |
| 152 | Supply & fixing in replacement ,testing of feeder pillar box, outdoor type cubical shape, three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick, factory fabricated, CPRI approved, powder coated, dust and vermin proof, provn for ventilation, angle iron frameand four legs of 50x50x6mm thick angle iron, 2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level, grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc & dismantling of old unserviceable LT panel with all accessories in any conidtion from foundation for shifting to MES store yard:- |
| 153 | Aluminiumbus bar with PVC sleeve suitable for 200 amps for phase & 200 Amp for neutral- 01Set. |
| 154 | Voltmeter,digital type 0- 500 volt,with selector switch - 01 set |
| 155 | Ammeter Digital type 0-100Amps, with selector switch and CT\"-1set ( set of three) |
| 156 | Phase indicating lamps LED type ( red , yellow, blue) 01 set |
| 157 | Incoming:- MCCB100 Amp 4 pole 25 KA with adjustable thermal and fixed magnetic release -01 No |
| 158 | Outgoing:- MCCB 63 Amps, 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No |
| 159 | (vii) FASD StarterML 2.0 FASD with MS sheet enclosure-01 No |
| 160 | (viii) Analog time switch -01 No |
| 161 | (ix) Single phase preventer-01 No |
| 162 | (Note for Ser item No 73 & 74:- (i) Panel drawing shall be approved by Accepting Officer.(ii) Old unserviceable LT panel alongwith allaccessories in any condition shall shifted to MES store yard and it will be taken on charge under demolition/salvage register.(iii) Make of accessories will be as per CA scpefication list of make & manufacturer\"s.(iv) The rate quoted deemed included all wiring & connection and testing installation & comissioning work. |
| 163 | An amount of Rs 1,93,177.95 shall be deducted from BOQ on account of schedule of credit |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail