| 1 | Supply and Fixing of Solar Hot Water FPC 300 LPD GL Tank, non pressurised, Inner Tank Shell Thikness 3mm, Inner Tank Side Dish Thikness3mm, incl taking down old unsv complete all as specified and directed. |
| 2 | Supply and fixing of Flat Plate Collector, FPC (FLAT PLATE COLLECTOR) as per given specification complete all as specified and directed.(i)Section : 1.2mm thick Aluminium(ii)Back sheet : 0.46 mm thick Aluminium(iii)Insulation : Fibre Glass wool with 50mm thick(iv)Foil : 0.05mm thick Aluminium(v)Flat plate collector fins (9 Nos) : Ultrasonic welded with Nalsun coating.(vi)Riser Pipe : 0.33mm & 0.6mm for Header pipe for Non-PRD(vii)Riser Pipe : 0.5mm & 0.71mm for Header pipe for PRD(viii)Glazing : 1000 x 2000 x 4mm clear toughened glass(ix)Glass beading : E.P.D.M. Rubber(x)Fasteners : Stainless steel(xi)Grommets : E.P.D.M Rubber(xii)Flanges : Brass(xiii)Finishing : Powder coating |
| 3 | Supply and fixing of Solar Water Heater FPC 300 LPD Stand including taking down old unsv stand complete all as specified and directed |
| 4 | Supply and fixing of Hose Pipe of suitable size for solar hot water heater including taking down old unsv hose pipe complete all as specified and directed. |
| 5 | Supply and fixing of Hose pipe Clip for solar hot water heater including taking down old unsv hose pipe clip complete all as specified and directed. |
| 6 | Supply and fixing of Make up tank including all connected accessories for 300 LPD solar hot water heater including taking down old unsv make up tank complete all as specified and directed. |
| 7 | Supply and fixing in repair of brass bib tap size 15mm bore complete all as specified and directed. |
| 8 | M&L for nitrile rubber insulation of suitable size for 20 to 50mm G.I hot water pipe per meter as per sample including taking down old unsv insulation complete all specified and directed. Note:- The Insulation thickness not less than 10mm complete all as specified and directed. |
| 9 | M & L of Servicing of 300 LPD Solar Water Heater with suitable cleaning materials complete set all as specified and directed. |
| 10 | Supply and fixing in repair of GI Coupling Union 15mm for Solar Water Heater complete all as specified and directed. |
| 11 | Supply and fixing in repair of GI CouplingUnion 25mm for Solar Water Heater complete all as specified and directed. |
| 12 | Supply and fixing in repair of Ball Valve 25mm for Solar Water Heater complete all as specified and directed. |
| 13 | Supply and fixing in repair of End Cape 32mm for Solar Water Heater complete all as specified and directed. |
| 14 | Supply and fixing of temperature Gauge 12\" 0-120 degree C for Solar Water Heater including taking down old unsv temperature Gauge complete all as specified and directed. |
| 15 | M & L for Sub main wiring with approved colour coding as per IS with two x 10Sqmm single core PVC insulated FRLSH cable with stranded copper conductor of size 10 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete including taking down old unsv sub main wiring complete all as specified and as directed. Note:- Two x 10 Sqmm for P and N + One x 10 Sqmm for earth and one run of PVC conduit will be measured as one unit. |
| 16 | Taking up or down of old galvanised steel water tubing 40mm bore, laid in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed. |
| 17 | Taking up or down of old galvanised steel water tubing 25mm bore, laid in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed. |
| 18 | Taking up or down of old galvanised steel water tubing 20mm bore, laid in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed. |
| 19 | Taking up or down of old galvanised steel water tubing 15mm bore, laid in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed. |
| 20 | Relaying of serviceable GI pipe 40mm bore in walls. Floors, ceilings including old fitting as obtained from item No.16 here-in-before after thorough cleaning of pipe (both sides) complete all as specified and directed. |
| 21 | Relaying of serviceable GI pipe 25mm bore in walls. Floors, ceilings including old fitting as obtained from item No.17 here-in-before after thorough cleaning of pipe (both sides) complete all as specified and directed. |
| 22 | Relaying of serviceable GI pipe 20mm bore in walls. Floors, ceilings including old fitting as obtained from item No.18 here-in-before after thorough cleaning of pipe (both sides) complete all as specified and directed. |
| 23 | Relaying of serviceable GI pipe 15mm bore in walls. Floors, ceilings including old fitting as obtained from item No.19 here-in-before after thorough cleaning of pipe (both sides) complete all as specified and directed. |
| 24 | Supply and laying 40mm bore galvanised steel water tubing medium grade as per IS-1239 (Part-1) with all new fittings in walls, floors, ceilings innew or old alignment complete all as specified and as directed. |
| 25 | Supply and laying 25mm bore galvanised steel water tubing medium grade as per IS-1239 (Part-1) with all new fittings in walls, floors, ceilings innew or old alignment complete all as specified and as directed. |
| 26 | Supply and laying 20mm bore galvanised steel water tubing medium grade as per IS-1239 (Part-1) with all new fittings in walls, floors, ceilings innew or old alignment complete all as specified and as directed. |
| 27 | Supply and laying 15mm bore galvanised steel water tubing medium grade as per IS-1239 (Part-1) with all new fittings in walls, floors, ceilings innew or old alignment complete all as specified and as directed. |