| 1 | Demolition & breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 150mm complete all as specified and removal off the site. |
| 2 | Demolition & breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 200mm complete all as specified and removal off the site. |
| 3 | Demolition & breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 100/110mm complete all as specified and removal off the site. |
| 4 | Dismantlingfloor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and removal off the site. |
| 5 | Demolition of precast block masonary / Brick work or precast concrete article built in cement mortar complete all as specified and removal off the site. |
| 6 | Demolition of cement concrete (reinforced) of any description and in any position such as precast manhole cover or cover slabs of septic tank etc (reinforcement cut as required to facilitate demolition) complete all as specified and removal off the site. |
| 7 | Demolition of cement concrete (Unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and removal off the site. |
| 8 | Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and removal off the site. |
| 9 | Taking down cement plaster any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc complete all as specified. |
| 10 | Dismantling wrought iron or mild steel work of any description complete all as specified and removal off the site. |
| 11 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified. |
| 12 | ditto all as per item No 11 above but beyond 1.5m or part thereof in depth beyond the first 1.50m complete all as specified. |
| 13 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified. |
| 14 | Removing excavated soils exceeding 250 M but not exceeding 500 M and depositing where directed. |
| 15 | M&L for precast RCC (1:1.5:3) type A1, nominal mix (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles set in cement mortar 1:4 including necessary formwork complete all as specified.Note: Reinforcement shall be measured and paid for separately. |
| 16 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified |
| 17 | M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in coping/ benching for man holes including necessary use and waste of formwork complete all as specified. |
| 18 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested bore of pipe 200mm complete all as specified. |
| 19 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested bore of pipe 150mm complete all as specified. |
| 20 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested bore of pipe 100/110mm complete all as specified. |
| 21 | M&L for salt glazed stone ware drain pipe grade - A, as per IS-651-1980, 200mm bore laid in trenches and jointed in cement mortar (1:1) complete all as specified. |
| 22 | M&L for salt glazed stone ware drain pipe grade - A, as per IS-651-1980, 150mm bore laid in trenches and jointed in cement mortar (1:1) complete all as specified. |
| 23 | M&L for salt glazed stone ware drain pipe grade - A, as per IS-651-1980, 100mm bore laid in trenches and jointed in cement mortar (1:1) complete all as specified. |
| 24 | M&L for mild steel TMT bars 6mm to 8mm dia cut to length , bent to shape required,including cranking, bending and binding with MS wire, not less than 0.9 mm dia or securing with clip complete all as specified. |
| 25 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips conforming to Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) complete all as specified. |
| 26 | M&L for 15 mm thick plastering in cement mortar 1:3 on fair faces of brick or concrete surface finished even & smooth without using extra cement complete all as specified. |
| 27 | M&L for rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick/concrete work surfaces mixed with integral water proofing compound all as per manufacturer\"s instruction and finished surface even and fair specified.Make: \"Plastocrete Plus\" of Sika/ \"Pidiproof LW\" of Pidilite for water proofing compound.Note: (i) WPC shall be measured and paid for separately as \"Supply only\".(ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction. |
| 28 | M&L for brickwork with burnt fly ash bricks (Old size bricks), straight or curved on plan exc 6m mean radius, built in, cement mortar 1:4 complete all as specified. |
| 29 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified. |
| 30 | M&L for 100 mm thick cement concrete type (1:4:8) D-2 (using 40mm graded crushed stone aggregate) as in sub base finished even and fair |
| 31 | Cleaning of blocked sewage line 150mm bore by rodding with using sectional sewer rod / flexible sewer rod /steel rod or split bamboo stick throughly from both sides between adjacent manholes / inspection chamber to manholes of any depth and size including well flushing with water till clear flow of sewage line is observed including taking out sludge & other foreign particles from manhole & pipe lines and buried in earth pits and spreading of bleaching powder @ 1kg/sqm over the sludge before filling of earth in layer of 30 cm complete all as specified and to the entire satisfaction complete all as specified. |
| 32 | Cleaning of blocked sewage line 200mm bore by rodding with using sectional sewer rod / flexible sewer rod /steel rod or split bamboo stick throughly from both sides between adjacent manholes / inspection chamber to manholes of any depth and size including well flushing with water till clear flow of sewage line is observed including taking out sludge & other foreign particles from manhole & pipe lines and buried in earth pits and spreading of bleaching powder @ 1kg/sqm over the sludge before filling of earth in layer of 30 cm complete all as specified and to the entire satisfaction complete all as specified. |
| 33 | All as per ser item No 31.00 above but for sewage line of 100/110mm bore.Notes for Ser item No 31 to 33(i)Length of manhole to manholesshall be measured in these item.(ii) Cleaning of sewage line to be started from down stream side, in this operation some pipe line will be cleaned automatically and need not to be cleaned by rodding and the same shall not be measured for payment.(iii) The unit rate of the item shall be deemed to include the removal of sludge / waste water accumulated in manhole / inspectionchamber due to cleaning of drain by rodding. (iv) Water required for cleaning the sewage line are the responsibility of the contractor and no extra payment will be made in this regard.(v) Cost of bleaching powder and lime shall deemed to be included in unit rate. |
| 34 | Cleaning of septic tank, soakage well of any size by removing of sludge from inside the septic tank and removing to a distance exc. 250m but not exc. 500m and buried the same in to earth pits including excavation of earth pits of required size & depth, depositing & spreading of sludge, returning in filling earth over sludge with bleaching powder @ 1 Kg/sqm and removal of surplus soil to a distance not exc. 50m allcomplete as specified.NOTE : Earth to be filled over the pit over bamboo matting after sufficient absorption of liquid for a period of 48 hours and spreading of bleaching powder over the sludge before earth filling as directed by the Engr-in-Charge. Cost of bamboo matting, spreading of bleaching powder and excavating the earth pit and filling earth etc shall be included in the unit rate as quoted and size of pit shall be made accordingly as directed byEngr-in-Charge. The measurement of sludge shall be taken as per size of earth pit with actual depth of sludge deposited in the earth pit after initial settlement of 48 hours. |
| 35 | Cleaning of blocked gully trap/floor trap etc of any size by roddingthoroughylyto manhole and well flushing with water after cleaning and including remove of sludge and other materials obtained from cleaning,garbage to a pit made for this purpose and filling upto the earth complete as as specified. |
| 36 | Cleaning of blockages of WHB, EWC etc of any size by rodding thoroughyly to manhole and well flushing with water after cleaning and including remove of sludge and other materials obtained from cleaning,garbage to a pit made for this purpose and filling upto the earth complete as as specified. |
| 37 | Cleaning ofblocked man holes upto 60cm depth by removing of sludge from inside and removing to a distance exc 200m but n. exc. 500m and burried the same into earth pits including excavation of earth pits of required size & depth, depositing & spreading of sludge, returning in filling earth over sludge and removal of surplus soil to a distance not exc. 50m all complete as specified. |
| 38 | All as per item No 37.00 above but exc 0.60 Metre but n.exc. 1.50 Metre in deep complete all as specified. |
| 39 | All as per item No 37.00 above but depth exc 1.50 m and n.exc. 3.0 m.Notes for Ser item No 34 to 39(i) The unit rate of the item shall be deemed to include the removal of sludge / waste water accumulated in manhole / septic tank / soakage chamber. (ii) Water required for cleaning the septic tank, manholes, gully/ floor trap shall be the responsibility of the contractor and no extra payment shall be made in this regard.(iii) Cost of bleaching powder and lime shall deem to be included in the quoted unit rate. |
| 40 | M&L for cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required, internal dia of pipe 100/110mm complete all as specified. |
| 41 | M&L for cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required, internal dia of pipe 150mm complete all as specified. |
| 42 | M&L for cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required, internal dia of pipe 200mm complete all as specified. |
| 43 | S&F in repair for PVC (SWR) pipes 110mm bore type \"A\",single socketed,conforming to IS-13592:1992 in anylength with rubber ringjointslaid in trenches or in floors and wall complete all as specified. |
| 44 | S&F in repair for PVC (SWR) pipes 75mm bore type \"A\",single socketed,conforming to IS-13592:1992 in anylength with rubber ringjointslaid in trenches or in floors and wall complete all as specified. |
| 45 | S&F in repair 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 46 | S&F in repair 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 47 | S&F in repair 110 mm bore PVC (SWR) vent cowl fixed in position complete all as specified. |
| 48 | S&F in repair 75 mm bore PVC (SWR) vent cowl fixed in position complete all as specified. |
| 49 | S&F in repair CI Nahani trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(diameter of outlet 100mm) complete all as specified. |
| 50 | S&F in repair CI floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(diameter of outlet 100mm) complete all as specified. |
| 51 | Supply only liquid proofing compound complete all as specified. |
| 52 | Taking up or down 15mm bore steel tubing and connections, including cleaning and refixing or removal to store complete all as directetd. |
| 53 | Taking up or down 20mm bore steel tubing and connections, including cleaning and refixing or removal to store complete all as directetd. |
| 54 | Refixing of reusable GI pipes of 15mm boreafter necessary cleaning and renewal of GI fittings as required all as specified.Note: (i) GI tubing retrieved against relevant item shall be reused.(ii) New GI fittings required shall be supplied by the contractor and the quoted rate shall be deemed to be inclusive cost of the same. |
| 55 | ditto all as per item No 54.00 above but for 20mm bore pipes. |
| 56 | S&F galvanised steel water tubing 15 mm bore dia,medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as directed. |
| 57 | S&F galvanised steel water tubing 20 mm bore dia,medium grade with all fittings and fixed complete to walls/ceiling or laid in floors complete all as directed. |
| 58 | M&L for 75mm thick cement concrete (1:3:6) type C2, (using 40 mm graded crushed stone aggregate) as in Plinth protection/path Finished even and fair concrete to be laid in panels area not more than 2 sqm each including necessary joint filling with bitumastic and use and waste of formwork required complete all as directed. |
| 59 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channels/drain including forming fair finished to drain channel complete all as specified. |
| 60 | M&L for loose filling with broken bricksaggregates of gauge 80mm to 150mm in soakage pits, soakage well complete all as specified. |
| 61 | M&L for coated pre-polished coloured chequered cement concrete tiles made with grey cement and pig-ments of size 30 cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry over in pavement / footpath / floors over incl 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed. |
| 62 | M&L for rolled mild steel in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe 410 -W (Gde- E- 250) quality-A |
| 63 | M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified. |
| 64 | M&L for preparation of newely plastered or unplastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 65 | M&L for Endura tiles of size 300 x 300 x 10 mmset, jointed and pointed in neat cement slurry over in pavement / footpath / floors complete all as specified and as directed. |
| 66 | M&L for 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed. |
| 67 | M&L for brick work with sub class B bricks laid on edge on vertical inclined sides of drain, bedded and jointed in CM (1:6) and pointed in CM (1:3) complete all as specified and as directed. |
| 68 | All as per item No. 67.00 described here-in-before but except \"bricks\" |
| 69 | M & L for brick work with sub class B bricks laid flat on vertical inclined sides of drain, bedded and jointed in CM (1:6) and pointed in CM (1:3) complete all as specified and as directed. |
| 70 | All as per item No. 69.00 described here-in-before but except \"bricks\" |
| 71 | Taking down steel doors (weighing 250 to 350 Kg each) and refixing in same opening after adjusting by cutting / welding of hinges made of angle iron section with ball bearing of suitable size (03 hinges in each shutter) to suit the raising of floors, complete all as specified and directed. |
| 72 | M&L for PCC (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) as in coping/ benching for man holes including necessary use and waste of formwork complete all as specified. |
| 73 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 74 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/ eaves board fixed with selp tapping screw complete all as specified and directed. |
| 75 | S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with selp tapping screw complete all as specified and directed. |
| 76 | M&L for Brick work using Fly Ash burnt bricks (old size)curved on plan with mean radius not exc 6m with bricks roughly cut to radius or bricks with wedge shaped jointsbuilt in cement mortar 1:6 complete all as specified and directed. |
| 77 | M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 78 | M&L for preparation of newly plasteredsurfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 2 coats ofcement based wall putty 1 mm eachto wall surface complete all as specified and directed. |
| 79 | M & L for preparing new Plasteredsurfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm).Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10 all as specified and directed. |
| 80 | M&L for coloured Non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc set and jointed in neat cement slurryover 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and as directed. |
| 81 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18Sqm but n. exc. 0.38 Sqm, vertical surfaces, in skirting etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match as in floor complete all as specified and directed. |
| 82 | M&L for 10mm thick rendering in CM (1:4) as backing layer in vertical surfaces of skirting dados repairs to steps complete all as specified and directed. |
| 83 | M&L for glazed colouredceramic tiles (450x350x7mm thick)on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match over 15mm thick rendering in CM(1:4) all as specified and directed by Engr-in-charge. |
| 84 | M&L for 75 mm thick cement concrete type (1:4:8) D-2 (using 40mm graded crushed stone aggregate) as in sub base finished even and fair |
| 85 | Dismantling posts or struts (wood, steel or RCC) embedded in concrete, brick work masonry etc any section, including taking out embedded portion and making good disturbed ground complete all as specified. |
| 86 | Excavation in soft/loose soil for post holes (or similar holes) each not exceeding 0.50 cum, getting out and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified. |
| 87 | M&L Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed including use and wastte of formworks complete all as specified.Note: Reinforcement shall be measured and paid for separately. |
| 88 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed Note : Each line wire to be measured. |
| 89 | M & L for galvanised Concertina Coil fencing with required dia 600 mm above 3 m height of wall existiong angle iron \"Y\" shape placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. strud tied with G.I. staples andG.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron all complete as per direction of Engineer-in-charge with reinforced barbed tape(R.B.T.) / spring core (2.5mm thick) wire of high tensile strength of 165kg/ sq. mm. with tape (0.52 mm thick)of supreme make or equivalent and weight 43.478 gm . metere ( cost of M.S. angle shall be paid separately ). |
| 90 | S&F 110mm dia PVC (SWR) branch piece single (single \"Y\"/T) equal or unequalwith acess door. |
| 91 | S & F 75 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door. |
| 92 | Dismantling water tanks and removing to store of capacity exc 500 & n.exc 1000 ltrs. |
| 93 | S&F 1000 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) double layered ISI marked incl connecting up pipes securing access covers etc as specified and as directed. |
| 94 | S&Fin repair 20 mm dia PVC ball cock (PVC floatvalves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut. (Make : PRAYAG). |
| 95 | S&F 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed. (Make : ESSCO/Marc/Zoloto). |
| 96 | S&F Structural steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde -E-250 quality- A) Add to any of the foregoing items if structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication all as specified and directed. |
| 97 | M&L Steel work in tubular trusses, purlins,post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 gradeSt.-240 painted one shop coat of redoxide primer. |
| 98 | S & F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentconfirming to Fe-410-W (Gde E-250 quality B) complete all as specified and as directed by Engineer-in-charge. |
| 99 | S&F Mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & n exc 30cm long dia of shank 16 to 20 mm |
| 100 | Expanded metal, cut to length, bent to shape required andty ing with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed completeto w ood or steel members n.exc 4 kg per sqm. |
| 101 | S&F Framed work such as grills, gratings, etcwith ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 102 | S&F 20mm thick of Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 103 | S& F in repair for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 104 | S& F in repair for 150 mm dia PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 105 | S&F in repairVitreous china wash down water closet pan (pedesatal pattern) (EWC)white including plastic water closet seat cover closed pattern with flat bottom, and cover and mild steel chromium plated hinging divice etc complete.Make: Prayag model GLECY No 4022 for pan and 518 for seat cover or equivalent as in the list of makes. |
| 106 | S&F in repairWater Closet (squatt pattern) of vitruous china squatting pan of pattern \"ORRISA\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cirstern and flush pipe) including connection to trap and flushing pipe anti syphon pipe etc complete including trap set in and incl concrete complete all as specifiedMake: Prayag model No 4054 or equivalent as in the list of makes. |
| 107 | S&F in repairs ofPVC low level flushing cistern, 10 ltr capacity, syphonic action type white body with inlet ball valve, float , handle,bracket, longflush pipe of PVC to suit flushing cistern ( long bend) etc complete & connecting to WC (Make : Sleek of Hindware, Slimline of Parryware or equivalent of Cera) |
| 108 | S&F in repar vitreous China Urinal, Half stall type, white (including flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.Make: Prayag model No 4998 or equivalent as in the list of makes. |
| 109 | S&F PVC connections 15 mm size with PTMT nuts of length 600 mm. |
| 110 | Supply and fixin repair CP Health Faucet of premium quality and PVC telephonic flexible tube fixed to 15mm bore pipe.Make : Jaquar Cat No. ALD-CHR-587 or techno commercially equivalent in Nycer/Cera/Kohler/Pearl/ROCA/Plumber/Essco |
| 111 | S&F in repair 15 mm bore two way bip taps CPwith flage complete all as specified and direcrted. Make- ESSCO Cat part DLX-512ANKN or techno commercially equivalent in Cera/Nycer/ROCA/Plumber/Jaquar |
| 112 | S&F in repairCP toilet paper holder with flat recessed type stainless steelcomplete all asspecified and as directed. |
| 113 | S&F in repairs vitreous china wash basin, white, flat back, size550x400m excluding taps, waste , including chain & plug & porcelain stopper ,brackets, cutting for pinning in ends of bracketes or erecting standand fixing and supply and waste pipe complete all as specified and directed |
| 114 | S&F15 mm fancytype swan neck pillar taps, cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore.(Make : ESSCO/Marc/Cera). |
| 115 | S&F in repairs angle valve,fancy type chromium plated, brass, 15mm bore complete all as specified and directed. Make- ESSCO Cat part MQT-526NKN or techno commercially equivalent in Cera/Nycer/ROCA/Plumber/Jaquar. |
| 116 | M&L for Cutting holes in brick walls Exc. half brick but not exc. Brick built in cement mortar inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required |
| 117 | Removing building materials and debris (other than excavated earth) to a distance of 5 KMinside MD Land at locations specified including loading and dumping/ leveling at the destination |