| 1 | S&F Anodised aluminium snap grid frame work for false ceiling+C5:C13 of size (605mm X 605mm) comprising of frame work of aluminium angle 25mmx25mmx2mm, main TEE 38mmx25mmx1.5mm and cross TEE 25mmx25mmx1.4mmcomplete all as specified and as directed. |
| 2 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 3 | S&F PVC insulation panels (10 mm thick) with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium complete all as specified and as directed. |
| 4 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6complete all as specified and directed. |
| 5 | M&L for rendering 15mm thick in cement mortar 1:6 on surface other than fair face of brick work of walls, finished fair& evencomplete all as specified and directed.. |
| 6 | M&L rendering 10 mm thick in CM(1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed.. |
| 7 | S&F Mild steel framed work such as grill grating etc, with ends bars shouldered and/or riveted of forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conformingto Fe-290Gde E-165 and portions frame framed and hung as gates including pintle hinges, steps hand-made sliding bolt etc complete all as specified and directed.. |
| 8 | M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.. |
| 9 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.. |
| 10 | M&L for Cement concrete 1:3:6type C2(40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.. |
| 11 | S&F rolled mild steel in roof trusses (framed) Fe-290 (Gde-E-165), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel of flat sections) including distance pieces, cleats etc complete all as specified and as directed. |
| 12 | M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 13 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 14 | M&L for factory casted machine made precast PCC solid block(1:2:4) type B1using 20 mm graded stone aggregate as in kerb stones setting in CM (1:4) etcincl necessary earthworkcomplete all as specified and directed. |
| 15 | Supplying and laying 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 16 | Supplying and laying 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 17 | Taking down cementor cement lime plaster, any description, on brick walls including racking out joints hacking for keyscrubbing down with water etc. complete all as specified and directed. |
| 18 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in CM 1:6 finishing even and smooth with out using extra cement complete all as specified and directed. |
| 20 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 21 | M&L for preparation of newly plastered surfaces of walls and applying two coats of Exterior emulsion paint over a coat of primer complete all as specified and directed. |
| 22 | M&L preparing old surfaces of walls plastered or uplastered including brooming down or wire brushing, scrapping down, and applying one coats of Exterior emulsion paintto match existing surfaces complete all as specified and as directed. |
| 23 | M&L preparing old surfaces of walls plastered or uplastered including brooming down or wire brushing, scrapping down and applying one of Oil emulsion distemper complete all as specified and as directed. |
| 24 | S&F Powder coated aluminium framefor doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 25 | S&F Powder coated aluminium door shutters with aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc.complete all as specified and directed. |
| 26 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and as per direction of Engineering-charge |
| 27 | S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with rubber beading in square n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 28 | S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with rubber beading in square exc 0.5 sqm in each pane complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 30 | M&L for screed bed or beddinglayer of mortar in CM (1:4), 15 mm thick in floor complete all as specified and directed. |
| 31 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 32 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchall as specified and directed. |
| 33 | M&L for rendering 10mmthick in CM 1:4 as backing coat all as specified and as directed. |
| 34 | M&L for Vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. |
| 35 | M&L for Vitrified tiles 10mm thick, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 36 | S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 37 | S&F Aluminiumanodised barrel tower bolt 200 mm, extruded section complete all as specified and directed. |
| 38 | S&F Brass 4 levers Mortise lock, vertical type, size 100 mm complete all as specified and directed. |
| 39 | Excavationin trenches notexc. 1.5 metre wide and not exc. 1.5 metre in+E6:K18 depth for foundations etc or for shafts wells, cesspit manholes , pier holes not exc 10 sqmon plan and not exc 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed. |
| 40 | Excavating over areas in soft/loose soil, n exc 1.5 m deep and getting out complete all as specified and directed. |
| 41 | M&L for PCC (1:4:8)type D-2 using 40mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed. |
| 42 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in surface channels and drain complete all as specified and directed. Note:- Forming fair finished channelshall be measured & paid separately. |
| 43 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed. |
| 44 | M&L for PCC (1:2:4)type B-1 using 20mm graded stone aggregate as in bed plate, coping etc slightly rounded angle, finished even and fair complete all as specified and directed. |
| 45 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in concrete bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete |
| 46 | M&L for 150mm diaReinforced concrete pipes, Class NP3 laid and jointed complete with collars complete all as specified and directed. |
| 47 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in CM 1:4 mixed with WPC, finished even and smooth without using extra cement complete all as specified and directed.Make:- WPC shall be measured and paid separately. |
| 48 | M&L for rendering 15 mm thickon other than fair facesof brick work or concrete surface in CM 1:4 mixed with WPC, finished even and smooth without using extra cement complete all as specified and directed.Make:- WPC shall be measured and paid separately. |
| 49 | Supply only integral water proofing compound (ISI marked) |
| 50 | Returning filing in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil. |
| 51 | Removing excavated surplus soil to a distancenotexceeding 50 mtr depositing where directed at a level not exceeding 1.50 metre above the starting point Make:- WPC shall be measured and paid separately. |
| 52 | M&L for precast reinforced concrete type B-1 (1:2:4) (20 mm graded stone aggregate) as in manhole cover slabset in CM 1:4 including necessary form work complete all as specified and directed. |
| 53 | M&L for Mildsteel high strength TMT bars as in reinforcement 8 mm dia cut to length bent to shape required including cranking. bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia(wt of binding wire will not be included and paid for separately) complete all as specified and directed. |
| 54 | Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel( 1/2 round or 3/4 section ) in cement concrete 1:2:4type B1 smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and directed. |
| 55 | M&L for Point wiring with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl with multi stranded copper conductor drawn through and including suitable size Non metallic rigid PVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor fabricated branded Modular Metal concealed in walls with suitable Modular plate with outer cover with suitable screws for housing switches socket outlets fan regulators etc. all as specified and as directed for One light point controlled by one switch |
| 56 | All as per item no.55 hereinabove but for One fan/exhaust fan point controlled by one switch |
| 57 | All as per item no.55 hereinabove but for one switch and socket outlet point 5 Amps on independent board. |
| 58 | All as per item no.55 hereinabove but for one switch socket outlet point 5 Amps controlled by one switch on same board along with other switches |
| 59 | All as per item no.55 hereinabove but for with copper conductor cable FRLS 2.5 sqmm for one 3 pin socket outlet 15 Amps concealed and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board. |
| 60 | S&F Modular Switch 5/6 Amps, 1module 1 Way complete all as specified and as directed. |
| 61 | S&F Modular Switch 15/16 Amps, 1 Module 1 Way complete all as specified and as directed. |
| 62 | S&F Modular Socket 5/6 Amps, 2 Module 2 and 3 pin complete all as specified and as directed. |
| 63 | S&F Modular Socket 15/16 Amps, 2 Module 2/3 pin complete all as specified and as directed. |
| 64 | S&FModular Fan Regulator Step type, 2 Module 120W complete all as specified and as directed. |
| 65 | S&F3 Module Cover Plate with frame and Metal Flush Box complete all as specified and as directed. |
| 66 | S&FModular white cover plate with frame and metal flux box, 6 module complete all as specified and as directed. |
| 67 | S&F of 8 Module Cover Plate with frame and Metal Flush complete all as specified and as directed. |
| 68 | S&F of 12 Module Cover Plate with frame and Metal Flush complete all as specified and as directed. |
| 69 | S&F Ceiling rose, 3 plate /PVC/ polycarbonate, isolated body complete all as specified and as directed |
| 70 | S&F LED lights fitting 1x 20W, 4 Feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 71 | S&FLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable sizecomplete all as specified and directed. |
| 72 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 73 | S&FLED Bldg. Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 74 | S&F of street light brackets made of 25 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to wall with suitable size of M.S. flat iron clamps, M.S nut & bolt with cup washers, painting to MS material with anti corrosive paint complete all as specified and as directed. |
| 75 | Supply and fixing ceiling fans complete with blades, down rods,and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEEFive star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 76 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 77 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 78 | S&F VTPN DB 6 way double door, vertical type,415 V, AC50 Hz with MCCB as incomer , minimum IP-43 protection conforming to IS-13032 & 8623, universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides etc. all as specified and as directed |
| 79 | S&F SPN DB Double door 12 way with tray for provision of MCBs, and Dolly for earth and neutral complete all as specified and as directed. |
| 80 | S&F SPN DB Double door 8 way with tray for provision of MCBs, and Dolly for earth and neutral complete all as specified and as directed. |
| 81 | S&F SPN DB Single door 4 way with tray for provision of MCBs, and Dolly for earth and neutral complete all as specified and as directed. |
| 82 | S&F Moulded case circuit breaker (MCCB) of 100 Amps 415Volt,16 KA 4 poles and current carrying capacity in the VTPN DB complete with connection testing and commissioning as specified and as directed. |
| 83 | S&F MCB TPN 63 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 84 | S&FMCB, SPN 40-63 Amps, C Curve, 10 kA, Complete all as specified and as directed. |
| 85 | S&F MCB Single Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 86 | S&F sub main wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 2.5 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitable size ISI marked Medium grade, , including 2.5 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed. |
| 87 | S&F sub main wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitable size ISI marked Medium grade,including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed. |
| 88 | S&F sub main wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 6 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitable size ISI marked Medium grade, including 6 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed. Note for item No.86, 87 & 88:- Two runs of 2.5 Sqmm / 4 sqmm / 6sqmm size PVC cable , one run of2.5 Sqmm / 4 Sqmm / 6sqmm size PVC cableas earth wire and one run of PVC conduit shall be measured as one unit length. |
| 89 | S&F sub main wiring with Four runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed / surface PVC conduit,including 1 runs of 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing sub main wiring complete all as specified and as directed.Note:- Four runs of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cableas earth wire and one run of PVC conduit shall be measured as one unit length. |
| 90 | M&Lfor Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI wire 4 mm dia by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 15 mm bore as protection pipe, GI wire of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed. |
| 91 | Supply, laying and testingcable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25 sq mm nominal cross section in service connections |
| 92 | Supply and laying fixingof 1100 volts grade heavy-duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sqmm nominal cross section in service connections. |
| 93 | Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Ampscomplete all as specified and as directed. |
| 94 | Supply and fixing post top lantern LED type 70watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protectionwith impact and corrosion resistant complete withdriver and lampcomplete all as specified and as directed. |
| 95 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, Indication lamp, Temperature Meter ,15 amp Plug topconnection piece, Hot and Cold Water Flexible connection pipe with couplings of inlet/outlet to respective pipes including necessary fixing arrangement Like Clamp , Nuts & bolts etc. on wall complete all as specified and as directed. |
| 96 | Cutting PPR/ PVC/ UPVC/ GI pipe of any bore upto 32 mm dia and reducing to required size by inserting Tee and other specials for connection to PPR 25 mm Outer Dia complete all as specified and as directed. |
| 97 | S&F 25 mm outer dia 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings like bends, reducers, couplings, sockets, etc. fixed complete to walls, ceilings or in floors etc. including chases Cutting and making good surfaces as per existing plastering / Granite / Tiles complete all as specified and as directed. |
| 98 | S&F CP Stop valves/ Angle valve, 15 mm dia cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 99 | S&F CP Bib taps, 15 mm dia cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |