Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth, for foundation of poles etc or for laying of cables, pipes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in Soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling-in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified. |
| 3 | Removing excavated surplus soil to a distance not exceeding50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified. |
| 4 | Taking up or down old unsv 15mm steel tubing and connections from walls and ceilings trenches, under floor or road, complete all as specified and directed. |
| 5 | ,---ditto--- all as per srl item No. 4.00 above but 20 mm dia complete all as specified and directed. |
| 6 | ,---ditto--- all as per srl item No. 4.00 above but 25 mm dia complete all as specified and directed. |
| 7 | ,---ditto--- all as per srl item No. 4.00 above but 50 mm dia complete all as specified and directed. |
| 8 | ,---ditto--- all as per srl item No. 4.00 above but 80 mm dia complete all as specified and directed. |
| 9 | S&F 15 mm bore galvanised steel tubes \"medium grade \"(ISI marked)with all necessary fitting (ISI marked) and fixed to walls with and incl GI clips and ceilings or laid in floors complete all as specified and directed . |
| 10 | ,---ditto--- all as per srl item No. 9 above but 20 mm dia complete all as specified and directed. |
| 11 | ,---ditto--- all as per srl item No. 9 above but 25 mm dia complete all as specified and directed. |
| 12 | S&F 15 mm bore galvanised steel tubes \"medium grade \"(ISI marked)with all necessary fitting (ISI marked) laid in trenches complete all as specified and directed . |
| 13 | ,---ditto--- all as per srl item No. 12 above but 20 mm dia complete all as specified and directed. |
| 14 | ,---ditto--- all as per srl item No. 12 above but 25 mm dia complete all as specified and directed. |
| 15 | ,---ditto--- all as per srl item No. 12 above but 50 mm dia complete all as specified and directed. |
| 16 | ,---ditto--- all as per srl item No. 12 above but 80 mm dia complete all as specified and directed. |
| 17 | Dismantling the existing 100 mm dia CI/DI pipe line carefully with joints of any type and taking out the CI/DI pipes & fittings/specials from trenches, cleaning the pipes properly and stacking the pipes & fittings/specials for inspection of Engineer-in-charge and segregate the serviceable & unserviceable pipes & fittings/specials as directed by Engineer-in-charge. Marking the unserviceable pipes & fittings/specials as “U/S” with white synthetic enamel thick paint for easy identification, complete all as directed for following size of pipe :-Note :- Excavation & earthwork shall be measured & paid for separately. |
| 18 | ,---ditto--- all as per srl item No. 17 above but 150 mm dia complete all as specified and directed. |
| 19 | ,---ditto--- all as per srl item No. 17 above but 200 mm dia complete all as specified and directed. |
| 20 | ,---ditto--- all as per srl item No. 17 above but 250 mm dia complete all as specified and directed. |
| 21 | Laying/fixing only serviceable CI/DI pipe 100 mm dia, laid in trenches in new or old position after cleaning of internal and external surfaces of pipe complete all as specified & as directed .Notes for srl item No 24 to 27 :- (i)Old serviceable CI/DI pipe retrieved from serial item No. 21.00 to 24 here-in-before shall be used. (ii)Excavation & earthwork, CI/DI fittings/specials and joints shall be measured & paid separately under relevant items of this Schedule. |
| 22 | ,---ditto--- all as per srl item No. 21 above but 150 mm dia complete all as specified and directed. |
| 23 | ,---ditto--- all as per srl item No. 21 above but 200 mm dia complete all as specified and directed. |
| 24 | ,---ditto--- all as per srl item No. 21 above but 250 mm dia complete all as specified and directed. |
| 25 | Supply, laying, jointing, testing and commissioning centrifugally cast Ductile Iron spun pressure pipes (Class K7) 100 mm dia with internal cement mortar lining and external zinc coating (130 gm/sqm minimum) and bituminous finish layer (minimum thickness 70 microns) with socket & spigot ends (ISI marked) conforming to IS 8329 suitable for push on rubber gasket joint complete laid in trenches including taking out old one all as specified & as directed . Note :-Excavation & earthwork, DI fittings / specials & joints shall be measured & paid for separately under relevant items of this Schedule. |
| 26 | ,---ditto--- all as per srl item No. 25 above but 150 mm dia complete all as specified and directed. |
| 27 | ,---ditto--- all as per srl item No. 25 above but 200 mm dia complete all as specified and directed. |
| 28 | ,---ditto--- all as per srl item No. 25 above but 250 mm dia complete all as specified and directed. |
| 29 | S&F in replacement 80mm bore sluice valves, class PN 1.6 with cast iron body with forged steel spindle, non rising type and cast iron wheel head, cast iron wheel handle, both ends flanged, IS-14846 marked comlete with neoprene rubber gasket, jointing material and incl nuts/bolts/washer of suitable size etc including taking down old unsv complete all as specified and directed.cified and directed including taking down old unsv. |
| 30 | ,---ditto--- all as per srl item No. 29 above but 100 mm dia complete all as specified and directed. |
| 31 | ,---ditto--- all as per srl item No. 29 above but 150 mm dia complete all as specified and directed. |
| 32 | ,---ditto--- all as per srl item No. 29 above but 200 mm dia complete all as specified and directed. |
| 33 | ,---ditto--- all as per srl item No. 29 above but 250 mm dia complete all as specified and directed. |
| 34 | S&F in replacement 80mm bore non return valves, class PN 1.6 with cast iron body and both ends flanged, IS-5312 ISI marked complete with neoprene rubber gasket, cast iron wheel handle, cast iron cap, jointing material and incl nuts/bolts/washer of suitable size etc including taking down old unsv complete all as specified and directed |
| 35 | ,---ditto--- all as per srl item No. 34 above but 100 mm dia complete all as specified and directed. |
| 36 | ,---ditto--- all as per srl item No. 34 above but 150 mm dia complete all as specified and directed. |
| 37 | S&F in replacement 50mm bore Butterfly valve, ISI marked complete with all fittings/accessories, required for fixing in existing header including taking down old unsv complete all as specified and directed. |
| 38 | ,---ditto--- all as per srl item No. 37 above but 80 mm dia complete all as specified and directed. |
| 39 | ,---ditto--- all as per srl item No. 37 above but 100 mm dia complete all as specified and directed. |
| 40 | ,---ditto--- all as per srl item No. 37 above but 150 mm dia complete all as specified and directed. |
| 41 | S&F in replacement ductile iron fittings, IS-923-2000, ISI marked viz bends, tapers, reducers, tee pieces (single or double branch) any type, angle / radiusand straight connecting pieces, but all ends flanged, size of pipe upto 250 mm bore, complete all as specified and directed. |
| 42 | S&F in replacement hard teak wood display board made of size 4 feet x 3 feet with aluminium alloy frame duly painted with suitable double coat paint complete with inside premium folked fabric (velvet) cloth surface for fixing of papers with 50 pins including glass fittings door & locking arrangement complete all as specified and directed by Engineer-in-charge. |
| 43 | M&L in repair for making connection from existing 50mm bore GI pipe line with help of MS saddle piece made out of MS flat iron 50x6mm complete with GI socket drilled and welded on it with one FI strip suitably positioned at the centre of pipe complete with MS nuts, bolts, washers (02 Nos), ferrules and rubber packing for branch connection for 50 mm dia pipe including necessary excavation and earth work and making good as per existing complete all as specified and directed . |
| 44 | ,---ditto--- all as per srl item No. 43 above but for 80 mm dia pipe complete all as specified and directed. |
| 45 | ,---ditto--- all as per srl item No. 43 above but for 100 mm dia pipe complete all as specified and directed. |
| 46 | ,---ditto--- all as per srl item No. 43 above but for 150 mm dia pipe complete all as specified and directed. |
| 47 | ,---ditto--- all as per srl item No. 43 above but for 200 mm dia pipe complete all as specified and directed. |
| 48 | M&L for cutting of bituminous road or any type of floor for laying of pipe etc not exceeding 1.5 mtr deep including refilling with material and watering well ramming/compacting and making good with PCC 1:2:4 type B-1, 10 cm thick complete all as specified and directed. |
| 49 | M&L for Construction of brick masonry valves pit chamber of 900x900x900 mm (Internal dimension of chamber) made with sub class \"B\" old size bricks, compressive strength not less than 75 Kg/sqcm built in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in PCC 1:3:6 type C1 using 20 mm graded stone aggregate and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of neat cement, PCC coping type B1 (1:2:4) using 20mm graded stone aggregate) MS frame with angle iron 40x40x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required ) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime complete as specified and locking arrangement directed by Engineer-in-Charge including dismantling of old valve pit & removing the material. |
| 50 | ,---ditto--- all as per srl item No. 49 above but 1200 x1200x900 mm size complete all as specified and directed. |
| 51 | Dismantling and taking out the existing unserviceable spindle and check nut of CI sluice valve of 80 mm bore and replacing with new SS spindle and nut as that of existing one complete with necessary rubber gasket, bolts and nuts as per site requirementfor any type CI sluice valves as per site requirement complete all as specified and directed |
| 52 | ,---ditto--- all as per srl item No. 51 above but 100 mm dia complete all as specified and directed. |
| 53 | ,---ditto--- all as per srl item No. 51 above but 150 mm dia complete all as specified and directed. |
| 54 | ,---ditto--- all as per srl item No. 51 above but 200 mm dia complete all as specified and directed. |
| 55 | Material and labour for providing area cleaning/sweeping of premises water supply installation (OHT Area/ Borewell Area)i.e Borewell at Ph no 04, BSO PH area, rajendra chowk, swimming pool, command gate, command camp, Ph No 01, PH No 10, 61 cav borewell, pologround borewells, queens road borewells, ajaymeru borewells, sub area borewell, hamid vihar borewell, sub area officer mess borewell, PH No 07 at PL & QR, PH No 08, PH No 04 & 05 at QR including cutting out green vegetation, roots, bushes, Treebranches, picking polothine and other unwanted material from theinstallation area and maintaining the ground surrounding the installation and removing the same out side the defence area as directed by Engr in charge. Note:-(i) Area shall be maintained begning from commencement of contract to completion date and paid once only, if contractor fails to clean the area of installation complete in all respect else recovery @ Rs 500 per day after 7 days intimation to contractor should be recovered and contractor\"s claim on this account shall not be entertained. Necessary T&P reqd for the work shall be arrange by contractor. |
| 56 | M&L for leakage rectification in existing 15mm bore GI pipe line by cutting of pipe line, making threaded for repair/ replacement of U/S fittings, pipe etc., or addition / alteration /replacement of the 15mm bore of pipe in short length (0.5m to 1m length) including fittings like tee, Elbow/ Sockets/ Union/ Nipple etc and making the line serviceable including pressure testing including necessary earthwork as required and making good as per existing complete all as specified and directed.Note : (i) GI Pipe in short length i.e. 0.5 to 1m length with necessary fittings for making the line serviceable, Earth work in any type of soil, taking down paver block along with PCC etc and refixing of same as per existing after leakage rectification and making good as per existing shall be included in quoted rates. |
| 57 | ,---ditto--- all as per srl item No 56 above but 20 mm bore complete. |
| 58 | ,---ditto--- all as per srl item No 56 above but 25 mm bore complete. |
| 59 | ,---ditto--- all as per srl item No 56 above but 32 to 80 mm bore complete. |
| 60 | S & F in repair 500 Ltrs capacity rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc complete all as specified in SSR Part I and directed by Engr-in-charge. |
| 61 | ,---ditto--- all as per srl item No 60 above but 1000 Ltr capacity complete. |
| 62 | ,---ditto--- all as per srl item No 60 above but 100 Ltr capacity complete. |
| 63 | S&F in replacement 15 mm bore gun metal gate valve/forged valve with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, IS-778 marked including taking down old unsv complete all as specified and directed. |
| 64 | ,---ditto--- all as per srl item No 63 above but 20 mm bore complete. |
| 65 | ,---ditto--- all as per srl item No 63 above but 25 mm bore complete. |
| 66 | ,---ditto--- all as per srl item No 63 above but 50 mm bore complete. |
| 67 | S&F in replacement of cast iron foot valve of 150 mm bore ISI marked, flanged ends with all fittings including taking down old unserveciable valve complete all as specified and directed. |
| 68 | ,---ditto--- all as per srl item No 67 above but 100 mm bore complete. |
| 69 | ,---ditto--- all as per srl item No 67 above but 80 mm bore complete. |
| 70 | S&F in repair ofleather flap for foot valve /NRV by taking out foot valve from UG sump, dismantling the same and refitting after repairing foot valve/ NRV upto 150 mm bore complete all as specified and directed. |
| 71 | S&F in replacement 80mm bore cast iron air release valve ISI marked( IS 14845) class PN 1.6 with two air outlets with isolating sluice valve and fixing up in water supply mains including necessary addition / alternation to DI pipe 150/200/250 mm dia bore with all necesary fittings complete all as specified and as directed. |
| 72 | M&L for repairing of leakage run lead joint in position of 80 to 250 mm dia CI/DI pipes by burning out existing joints, recovering lead, cleaning internal surfaces of socket and providing new joints with using recovered lead and additional new lead, making joint leak proof and testing incl necessary Earthwork complete all as specified and as directed. Note : Quoted rate included for new lead reqd |
| 73 | Supply and fix in replacement water high pressure gauge including socket welded to measure pressure in the delivery pipe 0-14 psi incl necessary fittings to install presuure gauge complete all as specified and as directed. |
| 74 | S&F in repair 15mm bore bib tap, long body, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete including taking down old one with all required accessories all as specified and directed. |
| 75 | Providing water tank 5000 ltr water capacity with pump and motor and arrangement to fill water tanks through delivery pipe on failure of water supply by any means at site complete all as specified and directedNote : Water collection should be done from nearby MES source of water borewell/OHT as directed by EIC. |
| 76 | M&L for repair & maintenance of existing header, jointing, welding pipe line with header incl material such as, Tee, long/shortMS bend coupller, flange, nuts, bolts, washer, rubber gasket (if reqd) as per existing size of pipe incl excavation and earth work complete etc. and testing & commissining of pipe line after repair all as per directed. |
| 77 | Supply and fixing in replacement rubber gasket tyton joint (push on joint) including rubber ring suitable for socket & spigot CI/DI/GI/MS pipe of 250 mm bore size including excavation in soft/hard surface, earth work, removing of interlocking tiles and refixing the same as per existing complete all as specified and directed |
| 78 | ,---ditto--- all as per srl item No 77 above but 200 mm bore pipe complete. |
| 79 | ,---ditto--- all as per srl item No 77 above but 150 mm bore pipe complete. |
| 80 | ,---ditto--- all as per srl item No 77 above but 100 mm bore pipe complete. |
| 81 | M& L for repair of existing MS pits/tank cover, CI cover for earthing pits, air pipe including replacement of unsv hinghes, hook, wire mesh and necessary welding work and applying one coat of synthetic enameled black paint over one coat of red oxide primer complete all as specified and directed |
| 82 | M&L for leakage rectification in 50mm dia LDPE/HDPE/PVC/PPR pipe line by cutting of existing pipe and making threaded for repair/ replacement of U/S fittings, etc., pipe in shortlengths (0.5m) or addition / alteration of 50 mm dia LDPE/HDPE/PVC/PPR pipe and including inserting/replacement of fittings and testing and including necessary exacavation & earth work as required for making it serviceable complete all as specfied anddirected . Notes:- (i)Cost of pipe in short lengths (0.5 mtr), fittings, and excavation & Earth work in any type of soil, taking down paver block along with PCC etc and refixing of same as per existing after leakage rectification and making good as per existing shall be included in quoted rates. |
| 83 | ,---ditto--- all as per srl item No 82 above but for size 80 to 100 mm. |
| 84 | M&L for leakage rectification, cutting of existing pipe and making threaded for repair/ replacement of U/S fittings, rubber gasket, saddle piece, nuts, bolts with washer etc., pipe in short lengths (0.5mtr) or addition and alteration of 50 to 100 mm dia CI/DI/MS pipe dia and including inserting/replacement of fitting, rubber gasket, welding, lead joint, and includingnecessary exacavation & earth work as required for making it serviceable complete all as specfied anddirected . Note:- Cost of pipe in short lengths ( 0.5 mtr), fittings, rubber gasket, welding and excavation & Earth work in any type of soil, taking down paver block along with PCC etc and refixing of same as per existing after leakage rectification and making good as per existing shall be included in quoted rates(ii)D-Joint, Saddle piece should be measured in the respective item of schedule. (v) The job location shall contain flange pipes in overhead tanks & UG sumps also. |
| 85 | ,---ditto--- all as per srl item No 84 above but for size 150 to 250 mm. |
| 86 | Supply, laying, jointing, testing and commisioning in repair header work ERW Mild steel pipe of 400 mm bore and minimum thickness of 6.0 mm as per IS 3589 & laid in floor, pipes should be jointed by flanged and based on supporting pillar for pump header etc. with including accessories all size short/ long elbow, flange joints, blank flanged, welding, fabrication, grinding, nuts, bolt, washers, rubber gasket of good quality including two coat of synthetic enamel paint over a coat of red oxide primer by spraying machine, show the direction of flow including taking down old unsv as per existing at site and make complete header work with air tight, end portion will be jointed by flanged, blank flanged, washers, nuts, bolts, make stand/ pillar by brickwork and pcc work for supporting of pipe as per existing, connected with existing pipe with proper joint, including excavation and earth work, demolition of PCC, remove the interlocking tile and refixing the same as per existing, making hole at walls and making the surface and wall as per existing complete all as directed. |
| 87 | ,---ditto--- all as per srl item No 86 above but for pipe of 300 mm bore complete. |
| 88 | ,---ditto--- all as per srl item No 86 above but for pipe of 250 mm bore complete. |
| 89 | ,---ditto--- all as per srl item No 86 above but for pipe of 200 mm bore complete. |
| 90 | Supply, laying, and testing in repair header work as ERW Mild steel pipe of class C of 150 mm bore and laid on floor/ underground for OH tanks and pumps header, STPs header etc. with including accessories all size elbow, flange joints, blank flanged, welding, grinding, nuts, bolt, washers, rubber gasket of good quality including two coat of synthetic enamel paint over a coat of red oxide primer by spraying machine, show the direction of flow including taking down old unsv as per existing at site and make complete header work with air tight, make stand/ pillar by brickwork and pcc work for supporting of pipe as per existing, connected with existing pipe with proper joint, including excavation and earth work, demolition of PCC, remove the interlocking tile and refixing the same as per existing, making hole at walls and making the surface and wall as per existing complete all as directed. |
| 91 | ,---ditto--- all as per srl item No 90 above but for pipe of 100 mm bore complete |
| 92 | ,---ditto--- all as per srl item No 90 above but for pipe of 80 mm bore complete |
| 93 | ,---ditto--- all as per srl item No 90 above but for pipe of 50 mm bore complete |
| 94 | S&F in replacement of old U/Sgland packing with new to the valves/pump sets. of any sizes/capacity complete with neoprene rubber gasket ,jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed. |
| 95 | S&F in replacement of float valves 20 mm bore high pressure of brass with epoxy coated brass rod and high density PTMT ball, screwed for GI Pipe, including replacement of existing unserviceable GI fittings like socket, nipple, reducer etc. where-ever required complete all as specified and directed. |
| 96 | S & F in replacement detachable joints suitable for GI/CI/DI pipe of 50 mm dia complete with cast iron ring, rubber rings nut, bolts, including cutting of pipe, necessary excavation and Earth work in any type of soil, taking down paver block along with PCC etc and refixing of same as per existing after leakage rectification and making good as per existing complete all as specified and directed . |
| 97 | ,---ditto--- all as per srl item No 96 above but suitable for 80 mm dia pipe complete. |
| 98 | ,---ditto--- all as per srl item No 96 above but suitable for 100 mm dia pipe complete. |
| 99 | ,---ditto--- all as per srl item No 96 above but suitable for 150 mm dia pipe complete. |
| 100 | ,---ditto--- all as per srl item No 96 above but suitable for 200 mm dia pipe complete. |
| 101 | ,---ditto--- all as per srl item No 96 above but suitable for 250 mm dia pipe complete. |
| 102 | Material and labour for preparation of old painted surface of electrical panel inner and outer surface of Length (0.5 m to 1 m), Height (0.5m to 1m), Breadth( up to 0.5m)by scrubbing with iron brush and applying two coat RAWL 7035/7032 paint with spray machine complete all as specified and directed. |
| 103 | ,---ditto--- all as per srl item No. 102 above but Length (0.5 m to 1 m), Height (1m to 2m), Breadth (up to 0.5m) complete all as specified and as directed. |
| 104 | ,---ditto--- all as per srl item No. 102 above but Length (1 m to 2 m), Height (1m to 2m), Breadth (up to 0.5m) complete all as specified and as directed. |
| 105 | S&F in replacement pressure pump of capacity CIL 120-9 circulating pump 0.16 HP 120 watt single phase including testing and commissioning. Complete as directed and specified by Engineer-in-charge. Make :- Crompton/KSB/CRI/ or equivalent |
| 106 | M&L for writing latters or figures (block, Romen, Italic or indian) n exc. 30 Cm height, before writing painter will scrub/clean the floor/wall as per requirement dimension and double coat a base paint complete all as specified and directed |
| 107 | M& L for repairing of LT panel any size including welding of doors, fixing of hinges, brazing complete all as specified and directed by EIC. |
| 108 | S&F in repair LED aviation/obstruction light on over head tank with die cast aluminium housing, IP 65 rating, nominal voltage 240 Volt 10 watt, integral driver incl wiring with 1.5 Sqmm 2 core wire up to the DB/nearest panel of OHT complete all as specified and directed.Make : Bajaj Cat Part BGAV 302 LED or equivalent in philips/ crompton/ havells as approved by GE |
| 109 | M&L for preparation of old painted GI/MS pipe surfaces upto 600 mm dia at various pump house. OHT, Valve chamber gate, UG sumps gates and applying with two coat of synthetic enamel paint and one coat of red oxide primer by spraying machine in proper manner including cleaning, scraping foreign material and degreasing surfaces complete all as directed. |
| 110 | S &F electric shock treatment chart printed on A0 size paper duly plastic laminated and fixed inside a wooden/PVC photo frame of 50 mm width with 3 mm sheet glass and 6 mm plybood backing and suitable hanging arrangement to wall with hooks/steel chain etc, including taking down old U/S one complete all as specified and directed by Engineer-in-charge. |
| 111 | S &F First aid chart printed on A0 size paper duly plastic laminated and fixed inside a wooden/PVC photo frame of 50 mm width with 3 mm sheet glass and 6 mm plywood backing and suitable hanging arrangement to wall with hooks/steel chain etc, including taking down old U/S one complete all as specified and directed by Engineer-in-charge. |
| 112 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed |
| 113 | Collecting the sample of water from different point such as bore well situated at diff locations of cantt for chemical and bacteriological testing of water from authorised govt lab /NABL approved lab for iron content in water, PH value, hardness, turbidity, chloride, fluoride and other parameters as per IS standards all as specified and directedNote : (i) Contractor will collect the water sample in presence of JE/Engr-in-charge and tested from NABL/ Govt approved lab and report submitted to AGE E/M in tripliacte. |
| 114 | M & L for flange pipe joints with 3mm thick rubber gasket (packing ring) or fibre board gasket for new/oldpipe lines including provision of suitable size bolts, nuts, washers and welding etc. for 80 mm bore pipe complete all as specified and directed. |
| 115 | M & L for flange pipe joints with 3mm thick rubber gasket (packing ring) or fibre board gasket for new/oldpipe lines including provision of suitable size bolts, nuts, washers and welding etc. 100 mm bore pipe complete all as specified and directed. |
| 116 | M & L for flange pipe joints with 3mm thick rubber gasket (packing ring) or fibre board gasket for new/oldpipe lines including provision of suitable size bolts, nuts, washers and welding etc. 150 mm bore pipe complete all as specified and directed. |
| 117 | M & L for boring under road/ hard PCC for passing the DI/GI/MS pipe upto 200 mm bore pipe pass through out complete all as specified and directed. |
| 118 | M & L for pipe supporting clamping for 25 mm dia GI pipe - pipe line fixing done with clamping system consists of Mono bracket + U bolt rubber sleeve mounted system running vertically with wall distance 75 mm :- Pipe support clamping made of :- 1. Mono bracket for 25mm pipe having wall distance 75 mm made of low carbon hot roll gauge corrected oil pickled and drawn (HROP D) steel (IS 1079) , material size 48 mm x 3 mm with ribs and notch are hot dip galvanised + Zn Al flake coated having salt spray test(test method - ASTM B-117-2019). 2. U bolt rubber sleeve mounted are made of low carbon mild steel with rod diameter 7 mm approx., Zn Al flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve, with hex flange nut BSW 5/16 x 18 x 8 x 13 with serration set - Zn Al flake coated. Hotdip Galvanizing : As per IS 2629 (1985) - 610 grams/m2 (>85 micron). Material Grade : IS 1079 used as per MTC confirms to EN 102043.1. Material Qty - For one unit : 1. mono bracket for 25 mm (1\") pipe, wall distance 75 mm - 01 Nos. 2 U Bolt rubber sleeve mounted for 25mm GI/ UPVC/ CPVC pipe - 01 Nos and 3. Fixing nail Zn coated of thickness 6.5 mm and length 63 mm - 02 Nos. Fixing Details : Pipe support clamping unit to be fixed at every metre distance in the duct/ wall as specified by EIC. Make : Shaivi or equivalent as approved by GE. |
| 119 | M & L for pipe supporting clamping for 15/20 mm dia GI pipe - pipe line fixing done with clamping system consists of Mono bracket + U bolt rubber sleeve mounted system running vertically with wall distance 75 mm :- Pipe support clamping made of :- 1. Mono bracket for 20 mm pipe having wall distance 75 mm made of low carbon hot roll gauge corrected oil pickled and drawn (HROP D) steel (IS 1079) , material size 48 mm x 3 mm with ribs and notch are hot dip galvanised + Zn Al flake coated having salt spray test(test method - ASTM B-117-2019). 2. U bolt rubber sleeve mounted are made of low carbon mild steel with rod diameter 7 mm approx., Zn Al flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve, with hex flange nut BSW 5/16 x 18 x 8 x 13 with serration set - Zn Al flake coated. Hotdip Galvanizing : As per IS 2629 (1985) - 610 grams/m2 (>85 micron). Material Grade : IS 1079 used as per MTC confirms to EN 102043.1. Material Qty - For one unit : 1. mono bracket for 20 mm (1\") pipe, wall distance 75 mm - 01 Nos. 2 U Bolt rubber sleeve mounted for 20 mm GI/ UPVC/ CPVC pipe - 01 Nos and 3. Fixing nail Zn coated of thickness 6.5 mm and length 63 mm - 02 Nos. Fixing Details : Pipe support clamping unit to be fixed at every metre distance in the duct/ wall as specified by EIC. Make : Shaivi or equivalent as approved by GE. |
| 120 | Note:-(a) Material like GI/DI/MS ERW Pipes with fittings, sluice valve, Non Return valves, foot valves, PVC tanks, Gate valves etc shall be procured by contractor in one time for Min 50% quantity of as mentioned in BOQ of approved make from authorised dealer of manufacturer within 45 days of date of commencement and purchase vouchers and manufacturer test certificate (where applicable) shall be submitted by contractor before claim of payment. After procurement material will be shown to Engr-in-charge with purchase voucher, if contractor failed to procuring above mentioned BoQ items recovery @ 500 per day will be recovered from contractors due and contractor\"s claim on this account shall not be entertained.(b) Contractor will be submitted the sample for material for approval of incorporated BoQ items within 15 days of date of commencement (b)The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail