| 1 | Dismentling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm DAR 15.23.1 |
| 2 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter DSR 12.41.2 |
| 3 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm DSR 12.42.1.2 |
| 4 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend DSR 12.42.5.2 |
| 5 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm DSR 12.43.2 |
| 6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes DSR 18.8.1 |
| 7 | Providing and laying rectified Glazed ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours White, lovry Grey Fume Red Brown laid on 20 mm thick cement mortar 1:4 (1 cement :4 Coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc complete. 11.39 |
| 8 | Providing and fixing 1st quality ceramic, glazed wall tiles conforming to IS 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thck bed of cmeent mortar 1:3 ( 1 cement 3 coarse sand) and jointing with grey cmeent slurry @ 3.3 kg per sqm, including pointign in white cement mixed with pigment of matching shade complete. 8.31 |
| 9 | P/F white vitreous china pedestal type (European Type/ wash down type) water Closet pan . 17.15 |
| 10 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White DAR 17.18.1 |
| 11 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 100 mm diameter.18.22.1. |
| 12 | P/F C.P. brass Angle Valve for basin mixture and geyser points ofapproved quality confirming to IS:8931.15 mm nominal bore.18.53.1. |
| 13 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia DAR 17.22b |
| 14 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass of approved quality complete with 6 mm thick hard board groung fixed to wooden cleats with C.P. brass screws and washers complete.17.31 |
| 15 | P/F Wash Basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern white vitrous china wash basin size 630x450 mm with a pair of 15 mm cp brass piller taps.17.7.1 |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws DAR 9.21.1 |
| 17 | 12 mm thick Cement Plaster with Cement mortar in proportion of mix 1:4 (1 cement : 4 coarse sand). DAR-13.4.1, |
| 18 | P/A white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.80 |
| 19 | Providing & fixing of wardrobe with 19mm thick plyboard grade-1 having both side decorative lamination with mica of 1mm thick including fevicoal, magnet, hinges, lock & handles, 2nd class teak wood beading of 20x15 mm with necessary screws complete as per directed by E/I. (Based on as per actual requirement) Please Enable Macros to View BoQ information |