| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(a) Group C |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 3 | (a) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 4 | (b) 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire |
| 5 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(a) 12 Module |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 7 | (a) 5/6 A switch |
| 8 | (b) 3 pin 5/6 A socket outlet |
| 9 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 10 | Supplying and fixing 12 module PVC modular surface box on wall surface along with suitable modular base & cover plate including fixing 4 Nos. 5/6 A modular switches and 4 Nos. 5/6 A modular socket outlets and including connections etc. as required. |
| 11 | Supplying and fixing of 3mm thickness phenolic laminated sheet of following size in front of the existing switch box including making arrangements to fix the switch/ sockets/ modular plate etc as required. |
| 12 | (a) 12\" x 10\" |
| 13 | (b) 11\" x 7\" |
| 14 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 15 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 12 way double door |
| 16 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(a) 4 way (4 + 12), Double door |
| 17 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(a) 8 way (4 + 24), Double door |
| 18 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 A |
| 19 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 20 | (a) Single pole |
| 21 | (b) Single pole and neutral |
| 22 | (c) Triple pole |
| 23 | (d) Triple pole and neutral |
| 24 | Supplying and erection of SMC box of size 530 x 450 x 175 mm in sideonwall/ pole as cable junction boxes,including properly connectingincoming and outgoing cables with 4 Nos 200 A aluminum bus bars for 3 phase and neutral connections along with suitable arrangements as required (excluding cable glands) |
| 25 | Design, Fabrication, Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type feeder pillar panel board of size 800mm (W) x 1200 mm (H) x 400 mm (D) suitable for 3 Phase, 415v, 50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following: hinged doors with locking arrangement, rain canopy, ventilation with vermin proof, bottom plate with knockout for cable entry, complete with aluminium busbars ofadequate capacity (min. 200A) for Phases & neutral, Suitable Angle Iron Base Frame of 50 X 50 x 6 mm, interconnections control wiring, including incoming and outgoing cables connections etc as required along with cement base for erecting the panel board at site of work and as directed by the Engineer in charge.Size: 800 x 1200 x 300 mm (nominal)Incoming :200A, 415 V Fuse carriers - 3 NosNeutral Link of required capacityOutgoing: 4 Pole 100 A MCCB - 1 Nos4 Pole 63A MCB - 2 Nos2 Pole 32 A MCB - 2 Nos |
| 26 | Supplying, installation,testing and commissioning of 1200 mm retrofit LED tube with suitable boxtype batten on wall/ ceiling/ truss with suitable fitting arrangements to terminate the metal conduit wiring with check nut to the fittings including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthingetc as required. (non compact type) (ISI certified) |
| 27 | Supplying, installation, testing and commissioning of 1200 mm 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy of 100 lumens/W along with Surface/Suspended waterproof industrial luminaire with polycarbonate housing and diffuser suitable for single 4 ft T8 LED tube on wall/ ceiling/ truss with suitable fitting arrangements to terminate the metal conduit wiring with check nut to the fittings etc as required. ( ISI certified ) |
| 28 | Supplying, fixing, testing and commissioning of 1200 mm 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy of 100 lumens/W byreplacing damaged spares of the existing fitting etc . as required(ISI certified) |
| 29 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Streetlight LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(a) 72 watt |
| 30 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry)of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (a) 200 watt |
| 31 | Supplying of PVC insulated, PVC sheathed / XLPE aluminium conductor armoured under groundpower cable of 1.1 KV gradeconforming to IS 1554 part-I/7098(part-I) 1998 with up to date amendments of the following sizes. |
| 32 | (a) 3 x 10 sq mm |
| 33 | (b) 3 x 16 sq mm |
| 34 | (c) 4 x 35 sq mm |
| 35 | (d) 4 x 25 sq mm |
| 36 | (e) 4 x 50 sq mm |
| 37 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(a) 100 mm dia |
| 38 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. |
| 39 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 41 | (a)Up to 35 sq mm |
| 42 | (b)Above 35 sq. mm and upto 95 sq. mm |
| 43 | Laying and fixing of one number ofPVC insulated and PVC sheathed/ XLPE armoured U Gpower cable of 1.1 KV grade of following sizes on wall surface/truss(or in recess of wall/floor by cutting the surface and making good the same) as required. |
| 44 | (a) Up to 35 sq.mm (clamped with 1mm thick saddle) |
| 45 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in mile stone shape with cement plastering of dimensions with 60 cm X 30 cm X 10 cm painted in yellow and lettering painted in black (LT Cable 440 Volts →) above the ground with concrete till 50 cm depth of same dimensions in ground as required. |
| 46 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 47 | (a) 3 x 10 sq mm(22 mm) |
| 48 | (b) 3 x 16 sqmm (25 mm) |
| 49 | (c) 4 x 35 sqmm (32 mm) |
| 50 | (d) 4 x 25 sq mm (28 mm) |
| 51 | (e) 4 x 50 sqmm (35 mm) |
| 52 | Supplying and fixing hot press molded SMC box of size 250x200x95 mm on wall/ truss with suitable clamps including providing and fixing suitable 3 way connector, 6A SP MCB and din bar for fixing MCBs terminating the incoming and outgoing cables /wires (but without end termination glands) making connections etc. as required |
| 53 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 54 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 55 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 56 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. |
| 57 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.(a) Above 6.5 Meter and upto 8.0 Meter |
| 58 | Providing and making steel pole collar with cement concrete (1 cement: 3 coarse sand: 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) |
| 59 | Cutting the bituminous/ CC road for trenching and cable laying and after cable laying and making good the road with suitable grade cement concrete as required at the site of work. |
| 60 | Supply of 7 mtr Swaged type Steel Tubular Pole as per IS: 2713/1986, Part-1 & 2 (conforming to 410-SP-32) to site of work as required |
| 61 | Painting the Steel Tubular/GI/Rail pole and all accesories including cable pipes, removing dust with cotton, painting with one coat of primer and one or more coats of aluminium enamel paint and providing zebra lining (y/b) up to 1.5 mtr from ground level with proper numbering as per site condition etc. as required. |
| 62 | Supplying, installation, testing & commissioning of 18W 4 pin PL-L type LED light with superior light output and integral driver having luminous efficacy of 100lm/W, colour temp 6500K including making connections from the existing point etc as required. |
| 63 | Supplying, installation, testing & commissioning of 40 W post top gate light landscape luminaire with IP 65 protection, glare-free and uniform light distribution with die cast housing and PC diffuser & spun aluminium reflector with lumen efficacy of >100 lm/W, colour temp 5700 K, THD < 10%, PF ≥ 0.95 within built 10 kV surge arrestor on existing pole / gate post with suitable accessories including providing connections etc as required at the site of work. |
| 64 | Supplying and fixing hot press molded SMC box of following size on wall surface with suitable clamps and fitting arrangements as required at the site of work.(a) 1000 x 690 x 300 mm (inside) |
| 65 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required |
| 66 | Dismantling the existing switch boards along with removing the switches, sockets and regulators along with hylam sheet as and where available and shifting to depot stores etc., as required. |
| 67 | Supplying and fixing following size GI surface modular box with suitable modular plate and cover in front on wall surface along with providing connections with in the existing conduit and wiring as required.(a) 18 Module (220mmX220mm) |
| 68 | Credit Items |
| 69 | (a) Dismantled Tube light fittings |
| 70 | (b) Dismantled DBs, Switch boards, GI pipes and clamps etc. |
| 71 | (c) Dismatled Street/Flood light fittings |
| 72 | (d) Dismantled Switch Gears, switches and Regulators |
| 73 | (e) Dismantled aluminium insulated wire/cables |
| 74 | (f) Dismantled steel tubular pole |
| 75 | (g) Dismantled ceiling fans |
| 76 | (h) Dismantled gate lights |