| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 3 | All kinds of soil |
| 4 | Filling quarry muck in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m : |
| 5 | CEMENT CONCRETE (CAST IN SITU) |
| 6 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 8 | REINFORCED CEMENT CONCRETE |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 10 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 12 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 14 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 16 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | MASONRY WORK |
| 18 | Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size for superstructure above plinth level up to floor two level including all cost of materials, labour charges etc.. |
| 19 | Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 20 | Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer |
| 21 | For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. |
| 22 | STONE WORK |
| 23 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : |
| 24 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | CLADDING WORK |
| 26 | Stone work (machine cut edges) for wall lining (veneer/cladding work) upto 2 m height, laid with cement-based high polymer modified, improved performance, slip resistant, extended open time, deformable tile adhesive (water based) conforming to IS:15477:2019(Type 3 \"T\" S1), in average 6 mm thickness and pointing/grouting in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade: |
| 27 | Laterite stone cladding tile (20mm thick or nearest) |
| 28 | WOOD AND P. V. C. WORK |
| 29 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Areaof opening forpanelinsertsexcluding portion inside grooves or rebates to be measured). Panelling for panelled ur panelled and glazed shutters 25 mm to 40 mm thick: |
| 30 | Float glass panes |
| 31 | 4 mm thick glass pane (weight not less than 10kg/sqm). |
| 32 | STEEL WORK |
| 33 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 34 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking withpushandpull operationcomplete,including thecost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 35 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
| 36 | GI Tubular TATA or equvalent |
| 37 | FLOORING |
| 38 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 39 | 25 mm thick |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 41 | Size of Tile 600x600 mm |
| 42 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 43 | Size of Tile 600x600 mm |
| 44 | Supplying and paving best quality highly compressed exterior grade floor paving tiles in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 45 | ROOFING |
| 46 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitchof corrugationasapprovedbyEngineer-in-Charge)of totalcoated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns.Sheet shouldhave protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 47 | Providing corrugated sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 48 | 2.0mm thick or equivalent polycarbonate Transpernt trafford sheet |
| 49 | Providing square type UPVC gutter with necessary clamps, bolts, nuts and specials such as nozzles sockets stoppers etc. including cost and conveyance of all materials and labour charges etc. complete as per the instructions of the dept. officers |
| 50 | 200mm or equivalent Square type UPVC |
| 51 | Providing and fixing precoated galvanised iron (GI) sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 52 | Ridges, hips or valley |
| 53 | FINISHING |
| 54 | 12 mm cement plaster of mix : |
| 55 | 1:4 (1 cement: 4 fine sand) |
| 56 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 57 | Finishing walls with Acrylic Smooth exterior paint of required shade . |
| 58 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm |
| 59 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 60 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 61 | On steel work |
| 62 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 63 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 64 | Two coats |
| 65 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 66 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 67 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 68 | French spirit polishing : |
| 69 | One or more coats on old work |
| 70 | Finishing Floors with premium floor guard (Apex floor guard or equivalent) with Silicone additives of required shade: |
| 71 | Two or more coats applied as per manufacturer specifications |
| 72 | Dismantling and Demolishing |
| 73 | Demolishing cement concretemanually/ bymechanicalmeans includingdisposalofmaterialwithin 50metresleadasper direction of Engineer - in - charge. |
| 74 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 75 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 76 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 77 | In cement mortar |
| 78 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 79 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 80 | For thickness of tiles above 25 mm and up to 40 mm |
| 81 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 82 | Asbestos Cement sheet |
| 83 | Dismantling C.I.pipes including excavation and refilling trenches aftertaking outthe pipes,manually/by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes &lead at site within 50 metre lead as per direction of Engineer-in-charge: |
| 84 | Up to 150mm diameter |
| 85 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 86 | ROAD WORK |
| 87 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 88 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 89 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 90 | WATER SUPPLY |
| 91 | Providing and fixing Polyvinyl Chloride (PVC) pipes, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 92 | 32 mm nominal dia Pipes (10kg/cm2) |
| 93 | 50 mm nominal dia Pipes (10kg/cm2) |
| 94 | 63 mm nominal dia pipe (6kg/cm2) |
| 95 | 110 mm nominal dia Pipes (4kg/cm2) |
| 96 | 25 mm nominal dia Pipes (10kg/cm2) |
| 97 | WATER PROOFING |
| 98 | CONSERVATION OF HERITAGE BUILDINGS |
| 99 | Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxanechemicalasapprovedby ArchaeologicalSurveyofIndia/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). |