| 1 | Part A: Electrical Work |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Group C |
| 4 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 5 | Group C |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 20 mm |
| 9 | 25 mm |
| 10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 11 | 3 x 1.5 sq. mm |
| 12 | 3 x 4 Sq. mm |
| 13 | Supplyof 380mm 900RPM heavy duty exhaust fan including aluminium louvers (make : National) and frame. complete in all respect as required at site up to entire satisfaction of EIC. |
| 14 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 15 | Installation of exhaust fan in the existing opening/make proper arrangement, including making good the damage, connection, testing, commissioning etc. as required. |
| 16 | Upto 450 mm sweep |
| 17 | SITC of LED bulkhead surface mounted with minimum lumen output 1100 Lumens with min efficacy 120 lumen/Watt having CCT 5700K having aluminium extrusion housing with PDC End Caps and high transmissibility PC diffuser, IP65, IK08 with surge protection minimum 6 kv luminaire of 4000-5700k, CRI>70, THD≤5% along with installation accessories as required on site complete in all respect . |
| 18 | Supply Installation, testing and commissioning of aluminium LED batten minimum lumen output 4000 Lumens with min surface mounted with minimum efficacy 135 lumen/Watt having CCT 5700K having extruded aluminium alloy housing with opal polycarbonate diffuser,IP20 with surge protection minimum 6 kvluminaire, CRI>70 along with installation accessories as required on site complete in all respect . |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 20 | 12 way , Double door |
| 21 | Supplying and fixing of following ways surface/ recess mounting ,double door, vertical type, 415 V, TP MCCB distribution board IP 43 of sheet steel, dust protected, duly powder painted, inclusive of 250 A tinned PAN assembly copper bus bar solid connection from incomer, common neutral link, earth bar,din bar for mounting including the cost of 160 Amp 16 KA FP MCCBs As a incomer Completeas required . |
| 22 | 4 way (4 + 12), Double door |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single pole |
| 25 | Double pole |
| 26 | Triple pole 63 A |
| 27 | SITC of chemical earthing of Copper Bonded Earthing Electrode Solid rod 25mm Dia & 3mtr including Ground EnhancementMaterial BAGS-2No.AndReadymadePolyplasticEarth Pit Cover which is Environment friendly, heavy duty, weather proof. complete in all respect as required at site up to entire satisfaction of EIC. |
| 28 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. |
| 29 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 30 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 31 | SITC of long case tube Axial flow fan with all accessories like bird screen/ louvers etc. suitable for wall mounted/floor mounted installation with outdoor termination box and connecting the axial flow fan chamber with duct as required on siteas per following specification & approved makes with suitable size of motor for lift well pressurization: |
| 32 | 6000CFM, 40mm Static pressure, 1440RPM fan long case for lifts. |
| 33 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 34 | Thickness 0.80 mm sheet |
| 35 | SITC of Direct online starter with enclosure having MPCB (suitable rating) for 3 HP motor with 4 pole power contactor min. 15A,phase indications with SITC of relayto switch on the pressurization system in case of activation of fire alarm system of that area and terminating the fire cables into panel. completed in all respect upto the satisfaction of Engineer in Charge. |
| 36 | Supply of aluminium/copper conductor , XLPE insulated, PVC sheathed armoured cable confirming to IS : 7098 (part-1) 1100 V grade of the following sizes. |
| 37 | 2 x 6 sq.mm (aluminium) |
| 38 | 4 x 16 sq.mm (copper) |
| 39 | 3.5 x 50 sq.mm (aluminium) |
| 40 | 3.5 x 95 sq.mm (aluminium) |
| 41 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 42 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 43 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 44 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct /panel as required. |
| 45 | Upto 35 sq. mm |
| 46 | Above 35 sq. mm and upto 95 sq. mm |
| 47 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 48 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 49 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 50 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 51 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 52 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 53 | Supply Erection, Testing and Commissioning of totally encloseddust and vermin proof double door, IP-43 Floor/wall Mounted distribution panel withLockable Doors fabricated out of CRCA Sheet of size 2.0mm thick with Powder Coating having top/bottom entry with all accessories,cable terimantion with proper gland and thimbles, live parts shrouded and busbars insulated with Color Coded heat shrinkable sleeves including solid connections, having LED lighting arrangement in panel, earthing etc., having following specifications : |
| 54 | Incomer : 1 no. MCCB 250 A, FP,36 KA with LSIG protection , ICS=100% ICU ,alongwith metering panel having digital multi function meter,1 Set of Indication Lamps, LED type, R,Y,B Phase indicating lamp with rotory handle. |
| 55 | Bus bar :- Al 4p,500A |
| 56 | Outgoing : 2 no. MCCB 160 A FP 16 KA with O/L & S/C protection, ICS=100% ICU protections with Digital Energy Meter, Set of Indication Lamps, LED type, R,Y,B Phase indicating lamp with rotory handle. |
| 57 | Complete in all respect as required on site. |
| 58 | Fabricating, providing & installing the lift architrave in the existing lifts comprising of 1.5mm thick honeycomb finished stainless steel sheet (304 Grade). Including cutting & bending the same in required shape & size and making frame having min. 6\"\"x6\"\" boxes with. 25mm x 25mm x 16swg MS tubes , so as to give proper shape and strength with double primer cot to prevent rusting to the architrave completed in all respect upto the entire satisfaction of EIC. |
| 59 | SITC of digital programmable timer withsuitable size of enclosure,contactor and other accessories as required for auto switching of particular equipement at required timings. All the items should be installed in the enclosure. Complete in all respect as required on site. |
| 60 | Dismentlingof existing SPN/TPN DB with MCB/MCCB, light fixture, conduit, exhaust fan etc. of various rating. The job includes disconnectingof the existing cables/wires in the existing machine room DBs.complete in all respect as required on site. |
| 61 | SITC of IP based CCTV system (As per specification attached) comprising of following items: |
| 62 | IP IR fixed 4 MP Dome camera |
| 63 | SITC of Field Termination Plug U/UTP |
| 64 | SITC of Cat 6a U/UTP information outlets |
| 65 | SITC of Cat 6a U/UTP Patch Cord 1.5 meter |
| 66 | Add GST @ 6.33% on all items |
| 67 | Less rebate for dismantled material of wires,conduits, light fixtures, DBs, MCB/MCCB,exhaust fans etc. |
| 68 | Part-B (Civil Work) |
| 69 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 70 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 71 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 72 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level |
| 73 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 74 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 75 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 76 | Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). |
| 77 | Gunmetal cramps |
| 78 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. |
| 79 | Wedge expansion type |
| 80 | Fastener with threaded dia 12 mm |
| 81 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, allnecessary fittingscomplete,includingapplyingaprimingcoat of approved steel primer. |
| 82 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 83 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 84 | Profile B |
| 85 | Fixing with adjustable lugs with split end tail toeach jamb |
| 86 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : |
| 87 | Udaipur green marble |
| 88 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 89 | 25 mm thick |
| 90 | 12mm cement plaster of mix : |
| 91 | 1:6(1 cement :4 fine sand ) |
| 92 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. |
| 93 | New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 94 | Providing and applying white cement based putty of average thickness 1 mm @ 6 kg per 10 sqm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 95 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 96 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 97 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in- charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. |
| 98 | Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 99 | In cement mortar |
| 100 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 101 | Of area 3 sq. metres and below |
| 102 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 103 | Dismantling old plaster/Granite tiles/Glazed tiles/Precast terrazo tiles with cement mortar/skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 104 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 105 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
| 106 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 107 | Stone work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the stone shade (To be secured to the backing by means of cramps, which shall be paid for separately) |
| 108 | Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 109 | Area of slab over 0.50 sqm |
| 110 | Providing and fixing high impact surface mount corner guard having vinyl snap on cover (Lead free) of 0.80\" (2 mm) thickness shall be extruted from chemical and stain resistant polyvinyl chloride with the addition of impact modifiers is no plasticizers shall be added (plasticizers may aid in bacterial growth). Surface shall have a Peblette texture for scratch resistance. Continious Aluminium Ratainer of .070\" (1.8 mm) thickness shall be fabricated from 6063- T5 aluminium, with a mill finish. Dimension to be of 3\" (76mm) x 3\" (76mm), 90 degree. |
| 111 | The rigid vinyprofile shall resist an Impact Strength of 30.2 ft- lbs/ inch as per. ASTMD- 256- 90b and shall not supprot fungal or bacterial growth in accodance with ASTMG-21 and G-22. The system shall also confirm to class A fire rating and ASTMD- 543 for chemical and stain resistance. It includes Top caps and bottom caps which shall be made of injection molded thermoplastic. Complete as per the direction of Engineer-in-Charge. |
| 112 | Add difference of Water Charges @ 0.50% |
| 113 | Credit for old dismantled including disposal of the same from the PGI premises complete in all respect. |
| 114 | Wooden doors with frame & fittings |
| 115 | Old dismantled bricks |