| 1 | Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 2 | Providing & laying in position cement concrete of 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering - All work up to plinth level. |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations & footing, base of column etc for mass concrete. |
| 4 | Providing and laying in position 1:1.5:3 grade ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. |
| 5 | Steel reinforcement for R.C.C work i/c straightening, cutting, bending, placing in position and binding all complete upto plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 6 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 8 | Providing and fixing organic waste Incinerator size( 1828 x 1524x1219 mm) made by 3-4 mm Heat resistant mild steel up to capacity 100 kg , dual chamber Machine frame- 3-4 mm Heat resistant mild steel, Refractory Hot face-155 mm,70% high alumina brick,Refractory fire brick layer-155 mmfire brick, insulation layer- 35 mm shree shera fiberglass blanket, Electrical heating (35 - 50 kw),cycle time 45-60 mins, top load, Kanthal A1 Heating Coils , 1 HP Blower for Air circulation with semi automaticControl panel, power supply 220 V Single phase/415 Volt Three phase withpollution control unit (Chimney) de established, scrubber type -Cyclon separator, ID Fan- 2HP ID fan for negative flow,Chinmey Stack- not less then 19.812 mtr ( 65 ft)with installation, testing and commissioning as required. as perapproved by Engg in charge |