|
| 1 | Consumables |
| 2 | 5 Lumens Thermodilution PA/Swan Ganz Catheter, |
| 3 | Absorbable Hemostat Powder with Microporous polysaccharide Hemosphere (MPH) Technology in one single sterile pack for 3 gms, in bellow applicator. |
| 4 | Absorbable Hemostat Powder with Microporous polysaccharide Hemosphere (MPH) Technology in one single sterile pack for 5 gms, in bellow applicator. |
| 5 | Absorbable Hemostat Powder with Microporous polysaccharide Hemosphere (MPH) Technology in one single sterile pack for 1 gms, in bellow applicator. |
| 6 | ABSORBABLE PORCINE GELATIN BASED TOPICAL ABSORBABLE FLOWABLE HEMOSTAT WITH 6CC SYRINGE PRE-FILLED WITH HEMOSTATIC MATRIX.2000 IU OF STERILE LYOPHILIZED HUMAN THROMBIN TOTAL VOLUME 8ML WITH 14.3 CM WHITE APPLICATOR TIP & 14.6 CM BLUE FLEXIBLE APPLICATOR TIP. |
| 7 | ACT tube compatible with Helena Actalyke mini-II machine |
| 8 | ACT tube compatible with Helena Actalyke XL machine |
| 9 | Adult Arterial Filter With Bypass Loop -The Arterial Filter should be for Adult Use. Priming Volume should not be more than 120 ml. Filter Pore size should be 30- 40 Micron. The Outlet and Inlet Blood Posts should be 3/8. The Filter should allow maximum Blood Flow Rate of 4.0 To 6.0 L / Min. The Filter should be provided with a Bypass Loop at the Inlet and Outlet Port. |
| 10 | Adult Hemoconcentrator-The Priming Volume Should Be 70 Ml • Effective Surface Area Of The Fibers Should Be ≈1 Micron • Blood Port Should Be ¼ With Luer Locks • Filtrate Port Should Be ½ -1/4Adapter. |
| 11 | Adult Oxygenator-• Priming Volume Should Be Less Than 190Ml• Blood Flow Range Should Be 0-6 Lts/Min.• Oxygen Transfer Should Be Atleast 400Ml/Min.• Heat Exchange Efficiency Should Not Be Less Than 0.50.• Housing Material Should Be Of Polycarbonate.• Effective Gas Exchange Surface Area Of The Fibers Should Be From 1.2 To 2.4M2 Gas Exchange Fibre Material Shud Be Polypropylene [P P]• Heat Exchanger Fibre Should Be Made Of Olyurethane[Tpu] And Surface Area Should Be Approx. 0.2 To 0 .3 M2 Blood Inlet Port -From Pump. 3/8 Blood Outlet Port 3/8 Cardioplegia Port 1/4 Gasinlet Port 1/4 Gas Outlet Port 1/4 Water Ports ½ Maximum Pressure Blood Inlet 1000 Mmhg Water Inlet 42 Psi • Blood Storage Capacity Of Hard Shell Reservoir Should Be Approx. 4000-5000Ml• Minimum Operating Volume Of Reservoir Should Be 200Ml.Head Exchancer With Oxyganator. |
| 12 | Bioprosthesis 2Nd Generation, Mitral- 25 Mm |
| 13 | Bioprosthesis 2Nd Generation, Mitral- 27 Mm |
| 14 | Bioprosthesis 2Nd Generation, Mitral- 29 Mm |
| 15 | Bioprosthesis 2Nd Generation, Mitral- 31 Mm |
| 16 | Bioprosthesis 2Nd Generation, Mitral- 33 Mm |
| 17 | Bovine Pericardial Patch 6’’x 6’’each |
| 18 | Breathing Circuit-Ventilator Circuit for adults. |
| 19 | CABG DRAPE KIT, specification attached |
| 20 | Cardiac Tissue Positioner system for cardiac apex : for beating heart surgery (suction based-Starfish type), |
| 21 | Cardiac Tissue Stabilization system: for beating heart surgery (suction based-Octopus type) suitable with standard retractors complete set, |
| 22 | Cardio Vascular Patch Size Hard PTFE Felt 10\" X 10\" |
| 23 | Cardioplegia Delivery System (To be supplied with suitable holder) |
| 24 | Cardioplegia Heat Exchanger- It Should Have Priming Volume Less Than 50 Ml, Blood Flow Rate Should Be Between 0 To 600 Ml/Min, Filter Pore Should Be Around 100 Um, Inlet Connection Should Be 1/4 , Outlet Connection Should Be 3/16. Heat Exchange Surface Area Should Be ≈.20M 2,Heat Exchange Should Be Of Stainless Steel corrugated/ Convoluted Pipes. Bubble Trap Should Be Integrated For Highly Efficient Debubbling, Exchangeable Water In /Water Out Blood Flow Path Bottom Up It Should Have A Stopcockprime /Perfusion For Easypriming. It Should Have Tip In The Surgeon Pack, so that it can be connected to Cardioplegia Cannula. It Should Be Available Both in 4:1 Configurations. |
| 25 | Customised Tubing/Heart Lung Pack With -Pediatric Design- P.V.C. Tubing,Complete Set Of Tubes, Connectors And Accessories, Arterial Pump Silicon Headsuction / Gas Line 1/4 \". Should have soft tubing . |
| 26 | Customised Tubing Pack/Heart Lung Pack With Adult Design- P.V.C. Tubing, Complete Set Of Tubes, Connectors And Accessories, Arterial Pump Head suction Silicon / Gas Line 1/4 \". Should have soft tubing . |
| 27 | Disposable Surgical Gowns |
| 28 | Extra Corporeal Membrane Oxygenator (ECMO) Circuit |
| 29 | Humidifier (Hme Filter)-Adult Size. |
| 30 | Humidifier (Hme Filter)-Paediatrics Size. |
| 31 | LOOP NO. 1 NYLON, Nonabsorbable, Sterile, Monofilament Polyamide No. 1 Suture (4 Metric), 150 cm., Looped on 48 mm., 1/2 Circle Round Bodied Heavy Needle |
| 32 | LUNG STAPLER CARTRIDGE (PURPLE) 45 MM |
| 33 | LUNG CUTTIING STAPLER CARTRIDGE 60MM |
| 34 | Monofilament Glycomer 3-0, 75CM , UNDYED 19MM 3/8 Circle Reverse Cutting |
| 35 | Neonatal Oxygenators-Priming Volume Maximum Should Be Less Than 50Ml. Minimum Operating Volume Approx. 30 Ml • Maximum Blood Flow Rate Should Be 0.2-1.2.Ltrs/Min. • Oxygen Transfer Should Not Be Less • Oxygen Transfer Should Not Be Lessthan 250Ml/Min.• Heat Exchange Efficiency Should Not Be Less Than 0.65.Surface Area of The Fibers Should Be Approx0.8 To 1.0M2 . • Heat Exchanger Fibre Material Should Be Made Of Polyurethane And Surface Area Should Be Approx. 0.22-0.50M2 . Blood Inlet Port 3/8 Blood Outlet Port 1/4Cardioplegia Port 1/4 Gas Inlet Port 1/4 Gas Outlet Port 1/4Water Port 1/2 Maximum Pressure Blood Inlet1000Mmhg,Water Inlet 42 Psi • Blood Storage Capacity Of HardShellreservoir Should Be Max 3000Ml.• Minimum OperativeVolume Of Hard Shell Reservoir Should Be 150Ml. |
| 36 | Oxidized Regenerated Cellulose based Topical Absorbable Hemostat, Structured Non-Woven material, with Bactericidal property. Ease-of-use in both open and minimally invasive procedures. Can be repositioned easily without sticking to instruments, size 4\"x4\" inch |
| 37 | Paeditric Oxygenator-Priming Volume Maximum Should Be Less Than 110Ml.Minimum Operating Volume Approx. 30 Ml • Maximum Blood Flow Rate Should Be 2.8.Ltrs/Min. • Oxygen Transfer Should Not Be LessThan 250Ml/Min.• Pressure Drop Should Be Least-Up To 100Mmhg Or Less.• Heat Exchange Efficiency Should Not Be Less Than 0.65. Surface Area Of The Fibers Should Be Approx0.8 To 1.0M2 . • Heat Exchanger Fibre Material Shouldbe Made Of Polyurethane [Tpu] And Surface Area Should Be Approx. 0.13M2 To 0.15M2 . Blood Inlet Port 3/8 Blood Outlet Port 1/4Cardioplegia Port 1/4 Gas Inlet Port 1/4 Gas Outlet Port 1/4Water Port 1/2 Maximum Pressure Blood Inlet 1000Mmhg,Water Inlet 42 Psi • Blood Storage Capacity Of Hard Shell Reservoir Should Be Max 3000Ml.• Minimum Operative Volume Of Hard Shell Reservoir Should Be 100Ml. |
| 38 | Polypropylene, 4-0 75CM, BLUE 16 / 17MM, 1/2 Circle Taper Point, Double Arm, |
| 39 | Polypropylene, 4-0 90 CM, BLUE 26MM 1/2 Circle Taper Point, Double Arm, |
| 40 | Polypropylene, 5-0 75 CM, BLUE 13MM 1/2 Circle Taper Point, Double Arm, |
| 41 | Polypropylene, 5-0 75 CM, BLUE 16 MM 3/8 Circle Taper Point, Double Arm, |
| 42 | Polypropylene, 5-0 75 CM, BLUE 17MM 1/2 Circle Taper Point, Double Arm, |
| 43 | Polypropylene, 6-0 75 CM, BLUE 11MM 3/8 Circle Taper Point, Double Arm, |
| 44 | Polypropylene, 6-0 75 CM, BLUE 13MM 1/2 Circle Taper Point, Double Arm, |
| 45 | Polypropylene, 7-0 75 CM BLUE 8MM 3/8 Circle Taper Point, Double Arm, |
| 46 | Polypropylene, 8-0, 60 CM BLUE, 6.5 MM 3/8 Circle Taper Point, Double Arm, |
| 47 | Polypropylene, 8-0, 60 CM BLUE, 8 MM 3/8 Circle Ever Point, Double Arm, |
| 48 | Polypropylene, 7-0, 60 CM BLUE, 9-9.3 MM 3/8 Circle Ever Point, Double Arm, |
| 49 | PTFE coated Cardiac Pacing wire* 3-0 60CM - 2X12, 17MM 1/2 Circle Taper Point |
| 50 | Radio opaque line Gauge Piece (Pack of 100) |
| 51 | Radio opaque line Sponge (Pack of 5) |
| 52 | Rigid Annuloplasty Ring with Sizer & Holder (Complete Set), Mitral (Size- 24 Fr, 26 Fr, 28 Fr, 30 Fr, 32 Fr, 34 Fr, 36 Fr) |
| 53 | Semi Rigid Annuloplasty Ring with Sizer & Holder (Complete Set),Mitral (Size- 24 Fr, 26 Fr, 28 Fr, 30 Fr, 32 Fr, 34 Fr, 36 Fr) |
| 54 | Semi Rigid Annuloplasty Ring with Sizer & Holder (Complete Set),Tricuspid (Size- 26 Fr, 28 Fr, 30 Fr, 32 Fr, 34 Fr, 36 Fr) |
| 55 | SILICONE Coated, Braided Polyester, 2-0 BLUE & WHITE 8X36\"\"/90CM DA, Oval Pledget 3x6MM, firm pledget, TAPER POINT, 1/2 CIRCLE, 16mm, |
| 56 | SILICONE Coated, Braided Polyester, 2-0 4/5 BLUE & 4/5 WHITE 8X30\"\"/75CM DA, Pledget (4.5X6 MM, 4.5X7 MM ) X 1.5 mm, FIRM pledget, TAPER POINT, 1/2 CIRCLE, 25mm, |
| 57 | SINGLE LEAFLET MACHENICAL HEART VALVE TILTING DISC ROTATABLE SIZE (17MM TO 29 MM)/any size AORTIC |
| 58 | SINGLE LEAFLET MACHENICAL HEART VALVE TILTING DISC ROTATABLE SIZE (23MM TO 33MM)/any size MITRAL |
| 59 | Pedaitric Hemoconcentrator-It Should Have Priming Volume Approx 35Ml. • Effective Surfacearea Of The Fibers Should Be Approx 0.5M Sq. • Blood Port Should Be ¼With Luer Locks. • Filtrate Port Should Be ½. •Maximum Trans-Membrane Pressure Should Be 500Mm Hg. • It Should Have Tubing Lines Along With Reservoir Bag.Should Be ¼With Luer Locks. • Filtrate Port Should Be ½. •Pressure Should Not Be More Than 500Mm Hg. • It Should Have Tubing With Reservoir Bag. |
| 60 | Sternal closure implant made of biocompatible PEEK (Polyetheretherketone) polymer with consistent tension across sternotomy or fracture of the sternum (Pack of 5 Bands) |
| 61 | Transparent Sterile Adhesive Dressing 6cm x 7cm ( centerline dressing) |
| 62 | Transparent Sterile Adhesive Dressing 7cm x 8.5cm ( centerline dressing) |
| 63 | Titanium Vascular Clips (Large) |
| 64 | Titanium Vascular Clips (Medium) |
| 65 | Titanium Vascular Clips (Small) |
| 66 | Titanium Vascular Clips (Micro) |
| 67 | Vascular ePTFE carbon impregnated Flex grafts 6 mm X 50 CM |
| 68 | Vascular ePTFE carbon impregnated Flex grafts 6 mm X 80 CM |
| 69 | Vascular ePTFE carbon impregnated Flex grafts 7 mm X 80 CM |
| 70 | Vascular ePTFE carbon impregnated Flex grafts 8 mm X 80 CM |
| 71 | Vascular ePTFE carbon impregnated Straight Graft 7 mm X 50 CM |
| 72 | Vascular ePTFE carbon impregnated tapped grafts with hemodynamic cuff 4-6 mm X 25 cm |
| 73 | Vascular ePTFE carbon impregnated tapped grafts with hemodynamic cuff 4-6 mm X 30 cm |
| 74 | Vascular ePTFE carbon impregnated tapped grafts with hemodynamic cuff 4-6 mm X 35 cm |
| 75 | Dacron Collagen Impregnated Corrugated Vascular Graft (Sizes-12-6 MM Y GRAFT) |
| 76 | Dacron Collagen Impregnated Corrugated Vascular Graft (Sizes- 6mm. X 60 cm Straight) |
| 77 | Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 6 Fr |
| 78 | Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 8 Fr |
| 79 | Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 10 Fr |
| 80 | Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 12 Fr |
| 81 | Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 14 Fr |
| 82 | Arterial Cannula Curved Tip Wire Reinforced, Plastic Tip, Arterial Cannulae Vented, Size- 16 Fr |
| 83 | Adult Arterial Cannula for Arch Cannulation Dip, Metal Tip Curved Arterial Cannulae Vented 3/8 inch Connector, Sizes- 18 Fr. |
| 84 | Adult Arterial Cannula for Arch Cannulation Dip Metal Tip Curved Arterial Cannulae Vented 3/8 inch Connector, Sizes- 20 Fr. |
| 85 | Adult Arterial Cannula for Arch Cannulation Dip Metal Tip Curved Arterial Cannulae Vented 3/8 inch Connector, Sizes- 22 Fr. |
| 86 | Adult Arterial Cannula for Arch Cannulation Dip Metal Tip Curved Arterial Cannulae Vented 3/8 inch Connector, Sizes- 24 Fr. |
| 87 | Aortic bovine pericardial bioprosthetic surgical valve aldehyde-free dry storage (integrity preservation treatment that enables aldehyde-free dry storage, an expandable Co-Cr band and fluoroscopically visible size markers, . Sizes-19 mm. |
| 88 | Aortic bovine pericardial bioprosthetic surgical valve aldehyde-free dry storage (integrity preservation treatment that enables aldehyde-free dry storage, an expandable Co-Cr band and fluoroscopically visible size markers, . Sizes- 21 mm. |
| 89 | Aortic bovine pericardial bioprosthetic surgical valve aldehyde-free dry storage (integrity preservation treatment that enables aldehyde-free dry storage, an expandable Co-Cr band and fluoroscopically visible size markers, . Sizes-23 mm. |
| 90 | Aortic bovine pericardial bioprosthetic surgical valve aldehyde-free dry storage (integrity preservation treatment that enables aldehyde-free dry storage, an expandable Co-Cr band and fluoroscopically visible size markers, . Sizes-25 mm. |
| 91 | Aortic bovine pericardial bioprosthetic surgical valve aldehyde-free dry storage (integrity preservation treatment that enables aldehyde-free dry storage, an expandable Co-Cr band and fluoroscopically visible size markers, . Sizes-27 mm. |
| 92 | Aortic Cannula Wire Reinforced Beveled Tip with elongated 1 piece with adjustable hemostasis introducer system with depth markings, Size – 6 Fr |
| 93 | Aortic Cannula Wire Reinforced Beveled Tip with elongated 1 piece with adjustable hemostasis introducer system with depth markings, Size – 8 Fr. |
| 94 | Aortic Cannula Wire Reinforced Beveled Tip with elongated 1 piece with adjustable hemostasis introducer system with depth markings, Size – 10 Fr. |
| 95 | Aortic Cannula Wire Reinforced Beveled Tip with elongated 1 piece with adjustable hemostasis introducer system with depth markings, Size – 12 Fr. |
| 96 | Aortic Cannula Wire Reinforced Beveled Tip with elongated 1 piece with adjustable hemostasis introducer system with depth markings, Size – 14 Fr. |
| 97 | Aortic Cannula Wire Reinforced Beveled Tip with elongated 1 piece with adjustable hemostasis introducer system with depth markings, Size – 16 Fr. |
| 98 | Aortic Punch Long Handle- A Conical Tip should be there for easy insertion by straight or button hole technique, Ten Blade Sizes for trimming to desired size and shape. Sizes –2.8 mm. |
| 99 | Aortic Punch Long Handle-A Conical Tip should be there for easy insertion by straight or button hole technique, Ten Blade Sizes for trimming to desired size and shape. Sizes –3.0 mm. |
| 100 | Aortic Punch Long Handle-A Conical Tip Sshould be there for easy insertion by straight or button hole technique, Ten Blade Sizes for trimming to desired size and shape. Sizes –3.5 mm. |
| 101 | Aortic Punch Long Handle-A Conical Tip should be there for easy insertion by straight or button hole technique, Ten Blade Sizes for trimming to desired size and shape. Sizes –4 mm. |
| 102 | Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 5fr |
| 103 | Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 7 Fr |
| 104 | Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 9 Fr |
| 105 | Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 12 Fr |
| 106 | Aortic Root Cannula With Vent Line-Radioopaque Tips With Vent Line, Flanged Standard Tip And Standard Introducer, Sizes- 14 Fr |
| 107 | Arteriotomy Shunts - Intracoronary Long Shunts.-Should Be Beveled Tip, Sizes -In mm.- 1.25 |
| 108 | Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In mm.- 1.5 |
| 109 | Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In mm.- 1.75 |
| 110 | Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In mm.- 2 |
| 111 | Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In mm.- 2.5 |
| 112 | Arteriotomy Shunts - Intracoronary Long Shunts-Should Be Beveled Tip, Sizes -In mm.- 2.75 |
| 113 | Arteriotomy Shunts - Intracoronary Long Shunts-Should be Beveled Tip, Sizes -In mm.- 3 |
| 114 | Arteriotomy Shunts - Intracoronary Long Shunts-Should be Beveled Tip, Sizes -In mm.- 3.5 |
| 115 | Endotracheal Tube with Cuff should have Low Pressure High Volume Cuff Size- 6 mm. |
| 116 | Endotracheal Tube with Cuff should have Low Pressure High Volume Cuff Size- 6.5 mm. |
| 117 | Endotracheal Tube with Cuff should have Low Pressure High Volume Cuff Size- 7 mm. |
| 118 | Endotracheal Tube with Cuff should have Low Pressure High Volume Cuff Size- 7.5 mm. |
| 119 | Endotracheal Tube with Cuff should have Low Pressure High Volume Cuff Size- 8 mm. |
| 120 | Endotracheal Tube with Cuff should have Low Pressure High Volume Cuff Size- 8.5 mm. Please Enable Macros to View BoQ information |