| 1 | [A]: CIVIL WORK |
| 2 | Sub-Head 1 :-Surface Dressing |
| 3 | Surface dressing of the gruond including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m |
| 4 | Sub-Head 2:-EarthWork |
| 5 | Earthwork in eacavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m , including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 6 | Extra for every additional lift of above 1.5 meters or part thereof in All kinds of soil |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre |
| 8 | Supply and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete |
| 9 | Sub-Head 3:-Concrete& RCC Work |
| 10 | Providing and Laying in position cement concrete of specified grade excluding the cost of centering & shuttering , 1:4:8( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 11 | Providing and laying in position ready mixed plain concrete or site batched design mix cement concrete for reinforced ccement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/Portland slag cement, admixture in recommended proportions as per IS:9103 to accelerate/retard setting of concrete, to improve ductility and workability without imparting strength; including pumping of concrete to site laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the following grades of concrete: All works upto plinth Level: Concrete of M25 grade with minimum cement content of 330kg/cum |
| 12 | Providing and Laying in position cement concrete of specified grade excluding the cost of centering & shuttering , 1:4:8( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 13 | Reinforced Cement Concrete work in beams, suspended floors, roofs having slope upto 15° landings, belconies, shelves, chajjas, intels, bands, plan window sills, staircases and spiral staircase up to floor fivelevel excluding cost of centering, shuttering, finishing and reinforcement: with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone agg. 20 mm nominal size). |
| 14 | Providing and laying damp proof course 50 mm thick with concrete cement 1:2:4(1 cement : 2 course sand :4 graded stone aggregate 20 mm nominal size) |
| 15 | Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre of damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil |
| 16 | Sub-Head 4:-Reinforcement Steel/ Rebar work |
| 17 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically treated bars |
| 18 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete. Above plinth level.Thermo-Mechanically treated bars |
| 19 | Sub-Head 5:-Form work |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 21 | Foundation, footings, bases of columns etc. for mass concrete. |
| 22 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 23 | Columns, pillars, Piers, Abutments, Posts and Struts. |
| 24 | Suspended floors, roofs, landings, balconies and access platform, with water proof 12mm ply |
| 25 | Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof 12mm ply |
| 26 | Sub-Head 6:-Brick work |
| 27 | Brick work with first class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 28 | Half brick masonry with first class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 29 | Sub-Head 7:-Wood work |
| 30 | Providing woodwork in frames of doors, windows, celestory windows and other frames wrought, framed and fixed in position with hold fast lugs or with dash fastner of required dia and length (hold fast lugs or with dash fastner shall be pais separately) with Local best quality Teak |
| 31 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws with Local best quality Teak wood 35mm thick |
| 32 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 33 | Providing and fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). |
| 34 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300x16 mm |
| 35 | Providing and fixing aluminium Tower bolts ISI marked anodised (anodic coating not less than garde AC 10 as per IS 1868) transparent or dyed to required colour or shade with nuts nad screws etc complete with 250x10mm |
| 36 | Providing and fixing chromium plated Brass handles with necessary screws screws etc.complete. |
| 37 | Providing 40x3mm flat iron hold fast 40cm long I/c fixing to framed with 10 mm dia .bolt nuts and windows plugs and wooden plugs and embedding in cement concrete block 30x10x15mm 1:3:6(1cement:3 coarse sand:6 graded stone aggrt.20mm nominal size) |
| 38 | Sub-Head 8:-Finishing work |
| 39 | 12 mm thick plaster finished with a floating coat of neat cement of mix 1:3 ( 1 cement : 3 fine sand ) . |
| 40 | 15 mm thick plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 ( 1 cement : 3 fine sand ) . |
| 41 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete. |
| 42 | Finishing walls with water proofing cement paint of of required shade: New work (two or more coats applied @ 3.84Kg/10sqm) |
| 43 | Painting with oil type wood preservatives of approved brand and manufacture: New work (two or more coats) |
| 44 | Varnishing with varnish of approved brand and manufacture: Two or more coats of glue sizing with copal varnish over an under coat of flatting varnish. |
| 45 | Polishing on wood work with ready made wax polish of approved brand and manufacture: New work |
| 46 | Applying one coat of water thinnable cement primer of approved brand and manufacture: Water thinnable cement primer |
| 47 | Finishing walls with textured exterior paint of required shade: New work (two or more coats applied @ 3.28Lts/1sqm) over and including base coat of water proofing cement paint applied @2.2kg/10sqm. |
| 48 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 49 | Sub-Head 9:-Flooring work |
| 50 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size Size of Tile 1000x1000 mm |
| 51 | Providing and laying Polished Granite stone flooring in required design and patterns, in linearas well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing withcement slurry admixed with pigment of matching shade including rubbing, curing and polishingetc. all completeas specified and as directed by the Engineer -in - Charge. PolishedGranite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 52 | Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work. |
| 53 | Providing and fixing 10mm thick acid and/or alkali resistant tiles of approved make and colour using acis and/ or alkali resistant mortar bedding nd joints filled with acid and / or alkali resisting cement as per IS:4457 complete as per direction of Engineer-in-charge. In flooringon a bed of 10mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand) Acid and Alkali resistant tile |
| 54 | Tile work in skirting, riser of steps and dado (upto 2m height) over 12mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry @ 3.3 kh/sqm including pointing in white cement mixed with pigment of matching shade complete: 8mm thick |
| 55 | Grading roof for water proofing treatment with Cement mortar 1:2:4( 1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) |
| 56 | Sub-Head 10:-Accessesories, Steel and Roofing work, Rain Water Harvesting works etc |
| 57 | Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc. |
| 58 | Providing and Fixing fly proof galvanised M.S. wire gauge to windows and clerastory window using galvanised MS wire guage with average width of aperature 1.4mm in both directions with wire dia.0.63mm all complete; With 2nd class teak wood beading 62x19mm |
| 59 | Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating sqare (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms |
| 60 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipe conforming to IS:13592 Type A including joining with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion, (i) Single sockeded pipes 75mm diameter |
| 61 | Providing and fixing on wall face unplasticised- PVCmoulded fittings/accessories for sunplasticised-Rigid PVC rain water pipe conforming to IS:13592 Type A including joining with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion |
| 62 | Single push fit Coupler:75mm |
| 63 | Single Tee with door:75x75x75mm |
| 64 | Bend 87.5°:75mm bend |
| 65 | Shoe(Plain) |
| 66 | P/F M.S. fan clamps type-I or II of 16mm dia. and M.S.bar bent to shape with hooked ends in RCC slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 67 | Providing and fixing in position vertical collapsible steel shutter with vertical channels 20mm x 10mm x 2 mm and braced with flat iron diagonals 20 mm x 5 mm sizes with top and bottom rails of T iron 40 mm x 40 mm x 6 mm with 40 mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers handles including applying a priming coat of Steel primer. |
| 68 | Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 69 | Painting synthetetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coats on new work. |
| 70 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. Electric resistance or induction butt welded tubes. |
| 71 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275gm/sqm |
| 72 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.0.63mm thick with zinc coating not less than 275gm/m2 |
| 73 | Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheetgutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. |
| 74 | [B]:Sanitary & Water Supply installation Work |
| 75 | Providing and fixing floor mounted white vitreous china single piece double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolt and gasket etx including making connection with the esixting P/S trap, complete in all respect as per directions of Engineer-in-Charge |
| 76 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm size respectively with automatic flushing cistern with standard flush pipe and CP brass spreaders with brass unions and GI clamps complete, including painting of ittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white PVC automatic flushing cistern |
| 77 | Providing and fixing urinal cock of approved quality and colour. 15mm nominal bore, 80mm long, 42mm high and 30mm wide with BSP female threads weighing not less than 48gms |
| 78 | Providing and fixing wash basin with CI brackets, 15mm CP brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White vitreous china wash basin size 630x450mm with a pair of 15mm CP brass pillar taps |
| 79 | Providing and fixing CP brass 32mm size bottle trap of approved quality & make and as per the direction of Engineer-in-charge |
| 80 | Providing and fixing CP brass long nose bib cock of approved quality conforming to IS standard and weighing not less than 810gms. 15mm nominal bore |
| 81 | Providing and fixing CP brass single lever telephonic wall mixer of quality and make as approved by Engineer-in-charge |
| 82 | Providing and fixing 600 x 450 mm levelled edge mirror of Indian make superior glass (of approved quality) completewith 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete |
| 83 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings arrangement of approved quality and colour, weighing not less than 105gms |
| 84 | Providing and fixing PTMT towel rail complete with bracket fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms |
| 85 | Providing and placing on terrace (at all floor level) polyethylene water storage tank IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes without fittings and base support for tank. |
| 86 | Providing and fixing CP brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15mm nominal bore |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 88 | 15 mm nominal outer dia Pipes |
| 89 | 20 mm nominal outer dia Pipes |
| 90 | Providing and Fitting Mini extra 1.5 HPSurface Domestic Single phase Pressure Pump (Blue or Aluminium) having flow rate (LPH) 5200-1800) of approved quality and manufacturer complete etc as per reqd. |
| 91 | Providing and fixing UPVC soil,waste,rainwater and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement,trenching,refilling & testing of joints complete as per Engineer in charge . |
| 92 | 75 mm |
| 93 | RCC Water Tank |
| 94 | Sub-Head 1:-Earth Work |
| 95 | Earth work in excavation in foundation trenches or drains including dressing of sides ramming of bottoms lift up to 1.5 metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres |
| 96 | Fillingavailable excavatedearth (excluding rock) in trenches , plinth side of the foundation etc. in layers not exceeding 20 cm in depth ,consolidating each deposited layer by ramming and watering lead up to 50 metres and lift upto 1.5 metres |
| 97 | Sub-Head 2:-Concrete & RCC Work |
| 98 | Providing and Laying in position cement concrete of specified grade excluding the cost of centering & shuttering ,1:4:8(1cement:4coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 99 | Providing and laying in position ready mixed plain concrete or site batched design mix cement concrete for reinforced cement concrete work,using coarse aggregate and fine aggregate derived from naturalsources,Portland Pozzolana/Ordinary Portland /Portland slag cement,admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete , to improve ductility and workability without imparting strength;including pumping of concrete to site laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per directionofEngineer-in-charge;for the following grades of concrete:All works upto plinth Level: Concrete of M25 grade with minimum cement content of 330kg/cum |
| 100 | Providing and laying in position ready mixed plain concrete or site batched design mix cement concrete for reinforced cement concrete work,using coarse aggregate and fine aggregate derived from naturalsources,Portland Pozzolana/Ordinary Portland /Portland slag cement,admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete , to improve ductility and workability without imparting strength;including pumping of concrete to site laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per directionofEngineer-in-charge;for the following grades of concrete:All works above plinth Level up to Floor V level: Concrete of M25 grade with minimum cement content of 330kg/cum |
| 101 | Sub-Head 3:-Reinforcement Steel/ Rebar work |
| 102 | Steel reinforcement for RCC work i/c straightening , cutting , bending , placing in position and binding all complete upto plinth Level.Thermo MechanicallyTreated Bars |
| 103 | Steel reinforcement for RCC work i/c straightening , cutting , bending , placing in position and binding all complete above plinth Level.Thermo MechanicallyTreated Bars |
| 104 | Sub-Head 4:-Form work |
| 105 | Foundation, footings, bases of columns etc. for mass concrete. |
| 106 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 107 | Sub-Head 5:-Finishing work |
| 108 | 15 mm thick plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 ( 1 cement : 3 fine sand ) |
| 109 | Sub Head 6: Roofing Work |
| 110 | Steel work in built up tubular (round, square, or rectangular tubes etc) trusses etc, including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc complete with Electric resistance or induction butt welded tubes |
| 111 | Providing and fixing precoated galvanised iron profile sheets (size, shape, and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120gsm as perIS:277, in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and poluester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desire by Engineer-in-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5+55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with Precoated galvanised iron profile sheets 0.35mm thick/4.2Kg/sqm |
| 112 | [C]:Internal Electrification and Installation Work |
| 113 | Point wiring in FR PVC casing & capping with modular type switch: Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd. |
| 114 | (a) Group A |
| 115 | (b) Group B |
| 116 | (c) Group C |
| 117 | Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd. |
| 118 | Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd. |
| 119 | 2X2.5mm2+1X2.5mm2 earth wire |
| 120 | 2X4mm2+1X4mm2 earth wire |
| 121 | Supplying and Fixing of following size of PVC casing capping along with accessories etc |
| 122 | 19.05mm |
| 123 | Supply and Fixing (following modular type switch/socket) on the existing modular plate and switch boxi/c connection but excluding modular plate etc as reqd. |
| 124 | 5/6 amps switch |
| 125 | 15/16 amps switch |
| 126 | 3 pin 5/6 amps socket outlet |
| 127 | 6 pin 15/16 amps socket outlet |
| 128 | Supply and Fixing stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc. |
| 129 | Supply and Fixing (following size/ module) G.I Box along with modular base and cover plate for modular switch in recess as reqd |
| 130 | 12 module (200mmx150mm) |
| 131 | Providing and Fixing (following capacity TP&N) dis-connector fuse switch unit inside the existing cubical panel board with ISI marks HRC fuses including drilling holes in the cubical panel board making connection as reqd. |
| 132 | 32 amp.TP&N |
| 133 | S/F (following way) single/double pole and neutral, sheet steel MCB distribution board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable pland plate, interconnection, phosphatized and powder painted including earthing etc as reqd (but without MCB/RCCB/Isolator). |
| 134 | 8 way double door |
| 135 | S/F 5 amp to 32 amp rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole |
| 136 | Single pole and neutral |
| 137 | Supply and Fixing single pole blanking plate in theexisting MCB DB complete etc as reqd. |
| 138 | S/F(following type) double pole 240V isolator in the existing MCB DB complete with connection, teasting and commissioning as reqd. |
| 139 | 40 amp |
| 140 | Earthing with copper earth plate 600mmx600mmx6mm thick i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as reqd |
| 141 | Extra for using salt and charcoal for pipe electrode as reqd. |
| 142 | Providing and fixing of lightning conductor finial mage of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc complete as reqd. |
| 143 | Providing and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd. (for vertical run) |
| 144 | Erection of of steel tubular pole not less than 8 mtrs but not exceeding 10 mtrs in cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation i/c excavation &refilling etc as reqd. |
| 145 | S/F 48\"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton) |
| 146 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd. |
| 147 | S/F FTL 1x36/40W street/Road Lighting luminaries muncell grey stove enamelled finish sheet steel housing with CRCA sheet steel reflector cover and accessories (ref:code no. BJSLF 128T5/530776) |
| 148 | S/F Horizontal S/F Horizontal down lighters D type CFL 2x18W 530806, BJDR 218HW2ED complete etc as reqd |
| 149 | [D]:Land Development |
| 150 | Surface dressing of the ground including removing vegetation andin-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m |
| 151 | Excavation in hilly areas in ordinary rock by mechanical means not requiring blasting.(Excavation in ordinary rock in hilly area by manual means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres.) |
| 152 | Supply and filling in plinth with sandy soil under floors including watering, ramming consolidating and dressing complete |
| 153 | Felling trees of girth including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable materials. |
| 154 | Beyond 30 cm girth upto and including 60 cm girth |
| 155 | Beyond 60 cm girth upto and including 120 cm girth |
| 156 | [E]:Fire Fighting & Fire Hydrant Work |
| 157 | Providing and Fitting ECO Fire Dry Powder type Fire extinguisher ISI mark with wall mounted hook for home ,Kitchen, Offfice, School and Industrial usewith capacity 25 Kgcomplete etc as per reqd. |