Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand) in ceiling etc |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work uptoVlevel1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Providing, hoisting and fixing up to floor five level precast reinforced cement oncrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform- up to floor V level |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) - up to floor V level |
| 10 | Brick work withcommon burnt clay F.P.S. ( non modular)bricks of class designation 7.5 insuperstructure above plinth level up to floor V level in all shapes and size in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.:Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 12 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm |
| 14 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete |
| 15 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 16 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length/ rawl plug .Second class teak wood for kitchen counter cupboard 50 mmx25 mm or as required at site. |
| 17 | Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) |
| 18 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws or welding. |
| 19 | Extra for providing lipping with 2nd class teak wood battens 25 mmminimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 20 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) |
| 21 | Deduct for not providing hinges in doors, windows or clerestory window shutters with :Stainless steel butt hinges with stainless steel screws :For 2nd class teak wood and other class of wood shutters |
| 22 | Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete: 250x10 mm |
| 23 | Providing and fixing aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete: 200x10 mm |
| 24 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. Complete: 300x16 mm |
| 25 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. Complete: 250x16 mm |
| 26 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm |
| 27 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 100 mm |
| 28 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame |
| 29 | Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforcedlastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames |
| 30 | Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Red sand stone |
| 31 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers . |
| 32 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 33 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 34 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts completeStainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 35 | Providing & fixing glass panes with putty and glazing clips in steel doors windows, clerestory windows, all complete with 4.0 mm thick glass panes |
| 36 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 37 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 38 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm |
| 39 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm |
| 40 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete |
| 41 | Making khurras 45x45cm with average minimum thickness of 5 cmcement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1mx 1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete |
| 42 | 12 mm cement plaster of mix : 1:4(1 cement : 4 course sand) |
| 43 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4(1 cement : 4 course sand) |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work |
| 45 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/10 sqm)on existing cement paint surface. |
| 47 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( JK or Birla puttey) |
| 48 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.Two or more coats on new work |
| 49 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) |
| 50 | Providing and fixing Scaffolding net of required width made of high density Polyethylene UV stabilized knitted on warp knitting machines having density 100grams/sqm and shading coefficient minimum 75% around the construction site/ for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing Scaffolding net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the contractor on completion of the work) |
| 51 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for therequired duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespectiveof duration of scaffolding ( necessary deduction for scaffolding in the existing items to be done) |
| 52 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 53 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. |
| 54 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin- Charge. (a) Internal Work- Exposed on wall |
| 55 | Taking out existing wooden door shutter/ MS Grill / wiermesh door , repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 56 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. completeand stacking within 50 metres lead:Of area 3 sq. metres and below |
| 57 | Demolishing lime concrete/ brick bat coba ( in cement mortar) manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge. |
| 58 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 59 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 60 | Demolishing brick work by manunally/by mechanical means including stacking of serviceable material and disposal of unserviceable material withinCampus as directed by the Engineer-in-charge.In cement mortar. |
| 61 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. completeand stacking within 50 metres lead:Of area 3 sq. metres and below |
| 62 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to thedumping ground within 50 metres lead. |
| 63 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer -in -charge. |
| 64 | Dismantling tile work in floor and wall laid in cement mortar including staking materialwithin 50 metres lead. For thickness of tiles i/c mortar 10 mm to 25 mm |
| 65 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 66 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 67 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 68 | Proving & fixing 600x450 mm or size as approved by Engineer -Inchargebeveled edge mirror of superior glass ( of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brss screws and washers complete. |
| 69 | Providing and fixing soil, waste and vent pipes: Sand cast iron S&S pipe 100 mm dia -1729 |
| 70 | Providing and fixing soil, waste and vent pipes: Sand cast iron S&S pipe 75 mm dia -1729 |
| 71 | Providing and fixing trap of self cleaningdesign with screwed down or hinges grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 outlet sand castiron S& S as per IS: 1729 |
| 72 | Providing and fixing trap of self cleaningdesign with screwed down or hinges grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 75 outlet Sand Cast Iron S&S as per IS- 1729 |
| 73 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm Sand cast iron S&S as per IS - 1729 |
| 74 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75 mm Sand cast iron S&S as per IS - 1729 |
| 75 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete 100x100x100 mm Sand cast iron S&S as per IS - 1729 |
| 76 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete75x75x75 mm Sand cast iron S&S as per IS - 1729 |
| 77 | Providing and fixing terminal guard :100 mmSand cast iron S&S as per IS - 1729 |
| 78 | Providing and fixing terminal guard :75 mmSand cast iron S&S as per IS - 1729 |
| 79 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter 100 mm |
| 80 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter 75 mm |
| 81 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :100 mm |
| 82 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :75 mm |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. external/internal exposed on wall 20 mm nominaldia pipes |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. external/internal exposed on wall 25 mm nominaldia pipes |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. external/internal exposed on wall 40 mm nominal dia pipes |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominaldia Pipes |
| 87 | Providing and fixing C.P. brass extension nipple size( 15 mm x50 mm)of approved make andquality as per direction of Engineer-In-charge. |
| 88 | Providing and fixing uplasticised PVC connection pipe with brass unions.45 cm length.15 mm nominal bore |
| 89 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet:150mm diameter |
| 90 | Providing & fixing PTMT grating of approved quality and colour . Circular type 100 mm nominal dia |
| 91 | Providing & fixing PTMT grating of approved quality and colour . Circular type 125 mm nominal dia with 25 mm waste hole. |
| 92 | Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15 mm nominal bore |
| 93 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15 mm nominal bore |
| 94 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing anf fixing tee, including cutting andall fittings TEE, REDUCER etc complete. Complete :25 to 40 mm nominal bore |
| 95 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 96 | Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 97 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 98 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore: 15mm nominal bore |
| 99 | * Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).* |
| 100 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height includingounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 101 | Chipping of unsound /weak concrete material from slabs, beams, columns etc. with manual chisel and /or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of dabris for all lead and lifts all complete as per direction ofEngineer-in-Charge.50 mm average thickness |
| 102 | Chipping of unsound /weak concrete material from slabs, beams, columns etc. with manual chisel and /or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of dabris for all lead and lifts all complete as per direction ofEngineer-in-Charge.25 mm average thickness |
| 103 | Cleaning ofreinforcement from rustfrom the reinforcement bars to give it a total rust free steel surface by using alkaline chemical rust removerof approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry all complete as per direction of Engineer-In-Charge. Bar up to 12 mm diameter |
| 104 | Cleaning ofreinforcement from rustfrom the reinforcement bars to give it a total rust free steel surface by using alkaline chemical rust removerof approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry all complete as per direction of Engineer-In-Charge. Bar above 12 mm diameter |
| 105 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm up to 200mm in RCC beam, lintels, columns and slabs to introduce steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete asper direction of Engineer-In-Charge. up to and including 12 mm diaor more as required at site |
| 106 | Providing, mixing and applyingbonding coat ofapproved adhesiveon chipped portion of RCC, as perspecifications and direction of Engineer-incharge complete in all respect : Epoxy bonding adhesive having coverage 2.20 sqm/ kg of approved make |
| 107 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 108 | Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument: 25mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 109 | Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument: 50mm thick in Grade M 25 with cement content not less than 330 kg per cum |
| 110 | Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh ( wt. 7.75 kg/sqm) or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. |
| 111 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 112 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 113 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete.Overall width 35 mm |
| 114 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter |
| 115 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 116 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door 75x75x75 mm |
| 117 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door 110x110x110 mm |
| 118 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° :75 mm bend |
| 119 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° :110 mm bend |
| 120 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75 mm |
| 121 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.110 mm |
| 122 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board610x510 mm bowl depth 200 mm |
| 123 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below |
| 124 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :250 mm diameter |
| 125 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :250 mm diameter |
| 126 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :250 mm diameter S.W.Pipe |
| 127 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 128 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. Of quality and make as approved by Engineer - in - charge. |
| 129 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe: 40 mm dia |
| 130 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia |
| 131 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. Brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 132 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore |
| 133 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 134 | Providing, mixing and applying over reinforcement bars, approved quality epoxy anti rust zinc rich coating as per manufacturer specification and direction of Engineer-in-Charge. |
| 135 | Cutting chasein brick masonry walls/RCC beam or RCC wall, widthof chase up to 230 mm ( fullbrick wall)and height up to 200 mm oras required at site as directed by Engineer -In Charge. Fixing the reinforcementin chase as directed and makinggood thesame with polymer modified Cement Concrete 1:1.5:3 ( 1 cement : 1.5 coarse sand :3 graded stone aggregate 12.5 mm nominal size and polymer @ 2% of cement as per manufacturing specifications),with necessary scaffolding,including disposal of malba/ building rubbish within 50 meter and necessary plaster in cement mortar 1:4 (1 Cement : 4 Coarse Sand) complete. The payment of reinforcement and Concrete to be paid for saperatly. (work of chase cutting to be done atroof level height of flats) |
| 136 | Taking out existing Mild steelZ section windowshutter ( glazed andwiemesh) , repaired/ replacement of windows sections by newand refixing of repaired windows/ shutters to existingMSframes, including replacement of damaged-section with hinges if required by electric welding and fittingswith screws, ( i.e. MS handle, stay and fittings etc)completeas required, all complete as per the direction of the Engineer-in-charge. The cost of Z-section and paintingto be paid sepratly.( only openig ofwindows to be measured for payment) |
| 137 | Taking out Mild steelrailing (fixed in Balconyof flats ) stacking within 50 metres lead, (area of railing not more than 4 sqm ) re fix the samerailing after repair thework of the flatsby cement concrete 1:2: 4up to floor V level complete as Directed by Engineer -In -Charge. |
| 138 | Supply, filling & compacted light weightfly ashblocks bats of Autoclaved aerated cement (AAC) in sunken portion of toiletsas directed byEngineer-In-Charge |
| 139 | Providing and fixing CPVC ball valveof approved quality: 25 mm as approved by Engineer in Charge. |
| 140 | Providing and fixing CPVC ball valveof approved quality: 40 mm as approved by Engineer in Charge. |
| 141 | Providing and fixing CPVC ball valveof approved quality: 50 mm as approved by Engineer in Charge. |
| 142 | Fixing water meter and stop cock in CPVC pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). |
| 143 | Buy back ofscrap materials after taking outthe scrapweighing and getting the gate pass issued by the department by the contractor Old Iron scrap (reinforcement ,CIPIPEand fitting, mild ateelZ section windows and fittings, GI pipes andotheriron scrap)etc. |
| 144 | Buy back of the materials after taking outthe scrapweighing and getting the gate pass issued by the department by the contractor wooden scrap |
| 145 | Buy back of the materials after taking outthe scrapweighing and getting the gate pass issued by the department by the contractor PTMT/ plasticfittings etc. |
| 146 | Buy back of the materials after taking outthe scrapweighing and getting the gate pass issued by the department by the contractorCP brass plumbing fittings. |
| 147 | Removal of IGL Installations from Block ( C-25 to C-32 Block) at CRRI Staff Colony, Maharani Bagh, New Delhi-110065. \" The work to be done on request by Indraprastha Gas Limited, IGL Bhawan, Plot No.4, Community Center, R K Puram, Sector-9, New Delhi-110022\" (Note rate for earlier block for 16 nos flat= Rs 19289.00 for rate for 8 nos flats= 19289/2=9645.00) |
| 148 | Fixing of IGL Installationsafter repair work competed in Block ( C-25 to C-32 Block) at CRRI Staff Colony, Maharani Bagh, New Delhi-110065\" The work to be done on request by Indraprastha Gas Limited, IGL Bhawan, Plot No.4, Community Center, R K Puram, Sector-9, New Delhi-110022\" (Note rate for earlier block for 16 nos flat= Rs 106896.00 for rate for 8 nos flats= 106896/2=53448.00) |
| 149 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 150 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 4 sq. mm + 1 X 4 sq.mm earth wire |
| 151 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSPVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 152 | Supplying & fixing offollowing way, single pole and neutral, sheet steel MCB distribution board, 240 volts on surface / recess, complete with tinned copper busbar, neutral link, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required. ( but without MCB/RCCB/Isolator):16 way double door |
| 153 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Single Pole |
| 154 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required. Group-B |
| 155 | Wiring for Twin control light point with 1.5 sq.mm PVC insulated copper conductor cable in surface / recessed PVC conduit with 2 waypiano type switch piano type switch, phenoliclimited sheet, suitable size M.S.box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc. as required . |
| 156 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. |
| 157 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 158 | Supplying and fixing call bell / buzzer and single phase, 230 volts, complete as required |
| 159 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 160 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 161 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 162 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required:20mm |
| 163 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required:25mm |
| 164 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required:100 mm X 100 mm X 60 mm deep |
| 165 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required:150 mm X 150 mm X 60 mm deep |
| 166 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 167 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair ( Two Pair) |
| 168 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 169 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 170 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 171 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:5 amp switch |
| 172 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:3 pin 5/6 amp socket outlet |
| 173 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:Telepone socket outlet |
| 174 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required:TVantenna socket outlet |
| 175 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, ServiceValue (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 176 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200 mm X 150 mm X 60 mm deep |
| 177 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 178 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 179 | Supplying of Tube Light-style LED Wall Light 20 Watt ( 4 feet ) set complete as per direction of Engg Incharge. |
| 180 | Dismantling/Removal of existing old electrical Switch Boards inclusive of all fitting etc. complete as per direction of Engg Incharge. |
| 181 | Supplying of Tube Light-style LED Wall Light10-12 att set (2 feet ) complete.as per direction of Engg Incharge. |
| 182 | Supplying & Installation of 8” sweep, 230 V exhaust fan / fresh air fan of plastic body complete in all respect as per direction of Engg Incharge. |
| 183 | Supplying and fixing 63 amp., 240V DP MCBin the existing MCB DB complete with connections, testing and commissioning etc.as per direction of Engg Incharge. |
| 184 | Supplying and fixing stepped type socket electronic fan regulator on the existingplate switch box including connections but excludingplate etc. as per direction of Engg Incharge. |
| 185 | Supplying ofsurface mounted LED Wall Light10-12 watt set complete. as per direction of Engg Incharge. |
| 186 | Dismantelling of Old DBBox from every floor as per the direction of Engineer -In- Charge |
| 187 | Supplying, Installation oftelecom MDF 20 pairs withbox complete in all respect as per direction of Engg Incharge. |
| 188 | Suppliying , installation, testingand commisioning of meter boardpanel of size subject to as per direction of Engg incharge as per site requirement,Powder coated, 2 MM CRCA sheet in tether finish, double door with IP44, and front Siemens gray color or including power wiring , thimling , adjusting , fiting, spriral cable Tie, Terminal Chanel, terminals, PVC duct, cutting, nut bolt busbar and Bus bar Fitting support labour, and margin , Engineering Charge ,and following:a)MCB 63 Amp DP 10 KA -12 nos b)16 sqmm, Single core Red and black for connection as required, c) 125A TP MCCB-01 nos |
| 189 | Buy back of scraps which are to be released from site, i.e. from CRRI Staff Colony, maharani bagh,taking it off premises only through gate pass issued from concerned department, which includes weighing ,loading, transportation andunloading as per direction of engineer-in- charge:PVC insulated Copper wire scrap |
| 190 | Buy back of scraps which are to be released from site, i.e. from CRRI Staff Colony, maharani bagh,taking it off premises only through gate pass issued from concerned department, which includes weighing,loading, transportation and unloading as per direction of engineer-in- charge:PVC scrap |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail