| 1 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified. |
| 2 | M & Lfor Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. |
| 3 | Description all as per above item No 2.00 here -in-before but except bricks, complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 5 | Taking down cement or cement lime plaster of any description on brick or stone walls and concrete surface of ceiling etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 6 | M & L for 15mm thick rendering in cement mortar 1:4 on fair face of brick walls/ concrete surfaces and finished even and fair without using extra cement in any position incl scafolding as required etc, complete all as specified and as directed. |
| 7 | Supply only liquid water proofing compound complete all as specified & directed. |
| 8 | M&L forPCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 9 | M & L for two coat of floor painton any type of surface including preprationof new/old surface make ;- Indigo floor paint and or equivalent as approved by GE) complete all as specified and directed. |
| 10 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for etc complete. |
| 11 | S&F Precast SFRC square or rectangular manhole covers 75 mm thick with frame medium duty conforming to IS-12592 covers, including necessary reinfocement, complete all as specified and as directed. |
| 12 | M&L for repairing of spalled concrete from RCC surfaces such as ceiling,beam, column, parapet, chajja etc in the following stages(i) Preparation of exisitng surfaces like chipping of unsound weak/loose concrete with electric hammer/manually including tapping all edges, making square shoulders of cavity etc not exceeding 50mm thickness , removal of debris complete all as specifiedRemoving plaster & finishes from all exposed / damaged portion of facia, roof projection, parapet, chajjas , over hanging slabs, columns, slabs & beams(II) Applying rust remover cum passivator sikkarust top 100 or equivalent at the rate of 0.2kg/sqm each coat as per manufacturer instructiosn to remove rust from exisitng reinforcementRemoving visible rust along the length of reinforcement using hand tools as approved.(iii) Mixing and applying two components epoxy reisn concrete bonding coat of sikkadur(R&B)42 or equivalent at the rate of 0.4kg/sqm (mixinbg prooprtion as per manufacturer instrucuion including preparation of surface by chipping and throughly cleaning of surfaces complete whether required over new reinforcement and as directed by engineer in charge the reinforcement shalll be measured seperaterly(iv) Applying a prebatched one component polymer modiifed cementitous patch repair mortar not excedding 50 mm in layer of 15mm thick each of product sikka monotop 122 F or equivalent as per manufaacturer instruction to match the exisiting surfaceNote :- This item will be also executed in highrise bldgs and necessary provision for T&P, scaffoling and safety measures etc shall deemed to be included in unit rate quoted by the tenderer for the same.) |
| 13 | Demolition of cement concrete (unreinforced) in ground floor or in any position and paving not exc. 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 14 | Dismantlingfloor, hearth or wall tilling , granite, stone cladding ,interlocking etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 15 | M & L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing completed all as specified and directed. |
| 16 | M & L for 18 to 20 mm thick granite (colour as approved by GE) of any type work table rubbed and polished as in steps, jambs, pillars, window cills, platform, water point platforms , floor etc over screed bedding layer, 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab , notching and moulding complete all as specified and as directed . |
| 17 | S & F for wall cladding tiles of size 300mm x 600mmx 8-12mm thick on vertical surfaces of wall , such as skirting, dados , etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match and over 10 mm thick screed bedin CM 1:3 and as per sample approved by GEcomplete all as specified and as directed. |
| 18 | M & L for Machine pressed precast conctete interlocking paver block of any shape and size (Two colour combination) confirming to IS 15658-2006 of 80 mm thick, M-35 Gradelaid dry in floor/pathincluding25 mm thick sand bedding layerincluding dismantling of the same complete all as specified and as directed. |
| 19 | M & L for Pre- Polishedcoloured chequered cement concrete tiles 300 mm x 300 mm x 22- 25 mm thick, set, jointed and pointed in neat cement slurry over 15mm thick screed bed in CM 1:6complete all as specified and as directed. |
| 20 | M & L for OUT DOOR coloured ceramic chequeredtiles 8 to 9 mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified. |
| 21 | Dismantling oldposts or struts ( wood, steel or RCC) any section, including taking out embedded portion and making good and excavation &prepration of postholesremoval of surplus excavated material completed all as specified and directed |
| 22 | Excavation in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum getting out, returning, filling in ramming earth or broken rubble in layers not exceeding 25 cm, watering and removing of surplus soil to a distance not exc 50m and making good surfaces, complete all as specified and as directed. |
| 23 | Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming including dismantling of the exisitng to Fe.290.Gde-E-165 |
| 24 | S & F framed work such as in door frame, door shuters / gate of angel or other sectionwith gusset plates, rails, braces, etc complete , drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings,including hings hold fast of Fe 410-W (Gde E-250 quality) etc complete all as specified. |
| 25 | S&F steel work in tubular trusses, doors , posts etcincluding special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed |
| 26 | Material & Labour for providing and fixing stainlesssteel (Grade 304) railing, guard bars,grills, doors , gatesetcmade of hollow tubes,channels, plates , bars , flats etc., including welding, grinding,buffing, polishing and making curvature (where everrequired) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing, guard bars,grills with necessary accessories & stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling of the old stainless steel work or iron work all as specified and directed. |
| 27 | S&F in repair Swimming Pool FRP Grating width 250mm complete all as specified and as directed |
| 28 | Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain or corrugated AC sheeting any gauge thickness as in roof covering, complete all as specified and as directed. |
| 29 | S & F for 2 mm thick fibre glass reinforced translucent corrugated sheeting with additional reinforcement of chicken mess with two corrugation side lap fixed with \"L\" or \"J\" type or crancked hook bolts including dismantling of of existing sheeting of any type, complete all as specified and directed. |
| 30 | S & F in repair precast cement concrete type B0 1:2:4 (12.5 mm graded aggregates) louvres and jallies,50 mm thick ( design and patern as approved by GE) set in CM (1:4)including all mouldings but excluding frame fixed over bdy wall or walk ways or in any position etc complete all as specified and directed. |
| 31 | S & Fin repair precast RCC coping/post of size 600x100x50 mm suitable for fixing of RCC Jallies in vertically & horizontally including necessary moulds and grooves as required in shape and size complete all as specified and directed. |
| 32 | S&F in repairPVC (SWR) pipes, 75mm dia, single socketed, in any length with rubber ring joints, fixed in walls, complete all as specified & directed. |
| 33 | S&F in repair PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, fixed in walls, complete all as specified & directed. |
| 34 | S&F in repairs of Stack clamps for 75mm bore of pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed. |
| 35 | S&F in repairs of Stack clamps for 110mm bore of pipe made out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts andecuring ends of stays to wall or roof, complete all as specified and directed. |
| 36 | S&F in repairs of 110mm bore of PVC (SWR) junction single,(Single T) equal or unequal provided with access door, complete all as specified and directed. |
| 37 | S&F in repairs of 110 mm bore of PVC (SWR) bends, complete all as specified and directed |
| 38 | S&F in repairs of 110mm bore of PVC (SWR) vent cowl, complete all as specified and directed. |
| 39 | M&L for cleaning/de-silting of loose mud, rubbish etc from drain bed including uprooting of vegetative growth throughly and wire brushing including flushing with water so as to achieve smooth flow of water in drain of bed width up to 60 cmand anydepth etc complete all as directed by Engineer in charge. |
| 40 | M&L two coat of synthetic enamel paint (finishing coat) over one coat of primer to newsteel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified. |
| 41 | M & Lfor preparation of new surface decorated brick/concrete/ plastered or unplastered surfaces of walls, pillars, cornices by brooming down etc and applying two coat of cement base paintcomplete all as specified and directed |
| 42 | M & Lfor preparation of oldsurface decorated brick/concrete/ plastered or unplastered surfaces of walls, ceiling pillars, cornices by brooming down etc and applying two coat of cement base paintcomplete all as specified and directed |
| 43 | M & L for preparation of new/old plastered external surfaces of walls, pillers, cornicesetc by scrapping down smoke soot, moulds, moss, efflorescent salts , trading oil and greasy spots andincludingcracks/holes in surface filling with white putty and scrapped surface areato obtain smooth finishing with water proof wall care putty as required and applying one coats of weather proof exterior acrylic emulsion paint premium quality complete all as specified and directed. |
| 44 | Cleaning of sewage line by using Mechanically operated 25 tonne truck mounted desludger with 12000Ltr capacity tankerhaving water fitted high pressure jetmachine for cleaning and desludging of sewage line, shall be used by the contractor as per scheduled programme in writingand completion of each jobto the entire satisfaction of Engineer-in-Charge as instructed. (NOTE : In case contractor fails to deploy the machine as per scheduled programme a damage of Rs 1500/- per day shall be deducted from his payment.) |
| 45 | Cleaning of sewage system including WCs, WHB, bottle traps, nahani and floor traps, soil/waste/rain/drain pipe running on external walls/cancealed type of building including junctions, manholes of any description and sewage lines of all sizes upto the final drop out let into septic tank/soak well of central sewage/drain wihtout distrubing its running/flowingand removing all type of blockagesin any situation bymechanical means, and disposing waste materials out side defence land strictly as per Hon\"ble Supreme Court directions,complete all as specified and as directed by the Engineer-in-Charge. NOTE:a) The above task shall be caried out by deployinga team, comprising 03 safaiwalas , 01 masson and 01 pipe fitter, for Offrs Md Accn , Messes/MES IBs / Command Huts / Central ammonites at Mall road, Polo road, Parade road,CPG,HQDA, Mandir marg, Tigris road, Church road,and other minor units. b) Where there is requirement of work involving scaffoldings and jhula, Contractor shall deploy the additional skilled team of workers expert in working on jhullas in high rise bldgs. c) If contractor fails to attend/clean a given complaint (received on any working days till 6 PM) on the same day, is liable to be charged damage Rs 500/- per day per complaint. Recovery for same will be deducted from his payment. d)One mechanical pump diesel/petrol for dewatering sludge water, safety belt, ladder, gloves gasmask, bucket to remove sludge, mechnical device required to reach work at difficult locations upto 9 stories shall be made available all time at site. |
| 46 | M&L for preparation of New plaster externalsurface of , Ceiling ,cornices, chajja, facia, drop wall, parapet, roof projection andapplyingtwo coats of weather proofingcoats of 100% Premium acrylic emulsion exterior paint , having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 liter/ 10 sqm including applying 1 mm thick external wall care puttyover disturbed surface during preparation or any reason with sanding for smooth surface, Allow 6-8hrs to dry the surface for painting of subsequent quotes etc, all work including up to G+8 storey bldg/tower complete all asspecified and all as directed by Engr- in-charge. |
| 47 | M&L for preparation of New plastered surface of Ceiling ,cornices, chajja, facia, drop wall, parapet, roof projection, andapplyingtwo coats of of 100% Premium acrylic emulsion interior paint, having VOC less than 50 gm/liter and including priming coat ofprimer applied @ 0.90 liter/ 10 sqm including applying 2mm thick wall care puttyover disturbed surface during preparation or any reason with sanding for smooth surface, Allow 6-8hrs to dry the surface for painting of subsequent quotes etc, all work including up to G+8 storey bldg/tower complete all asspecified and all as directed by Engr- in-charge. |
| 48 | M&L of factory made Fiberglass Reinforced Plastics (FRP) “CHAJJA” of “Fibreways” brand or equivalent 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos. vertically and 1 no. horizontally 50x2mm thick M.S. Flat with 12mm in built hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete using silicon sealant from top and bottom to make it waterproof in one single piece casted monolithically including all necessary fittings complete all as specified and directed.The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fiberglass chopped strand mat (CSM) as per IS: 11551, complete with protective Gelcoat UV coating on top for complete resistance from the extreme of temperature, weather & sunlight complete all as specified and directed.Note: All fittings/fixtures including in above quote rates. |