| 1 | Excavation over areas, n exc 1.5 m deep and getting out in any type of soil, complete all as specified and directed. |
| 2 | Excavation over areas, exc 1.5 Mt but n exc 3.0 m deep and getting out in any type of soil. complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 4 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 5 | M&L for Cement concrete type D2 in CM 1:4:8 using (40mm graded stone aggregate) as in foundation /LT Poles /Garden Lights complete all as specified and directed. |
| 6 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete, complete all as specified and directed. |
| 7 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter to fair and smooth faces of wall , complete all as specified and directed. |
| 8 | M&L for Reinforcement cement concrete M-25 (Design Mix) in Foundations, including rafts, footings, foundation beams; plinth beams and wall bands ; bases for columns, etc; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 9 | M&L for Reinforcement cement concrete M-25 (Design Mix) in Walls, retaining walls, basement walls, ballast wallsand the like; any thickness; above top of footings; including attached pilasters and buttresses, complete all as specified and directed. Note : Top coping portion with same RCC Concrete same shall be measured in this item. |
| 10 | M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 11 | M&L for TMT Mild steel bars5mm dia and over up to an including 10mm dia in striups , spacers and binders, complete all as specified and directed. |
| 12 | M&L for Preparing surfaces of plastering or unplastered surfaces on walls andapplyingtwo coats of cement base paintover a coat of alkali resistance primer, complete all as specified and directed. |
| 13 | S&F for framed work such as grills, gratings, etc with ends of bars and similar conforming to Fe-290 Gde Kg E-165 complete all as specified and as drected.specified and as directed |
| 14 | M&L for Mild steel framed work as in Y shaped horn/over secunty wall for fixing barbed wire and Kg concertina a coils welded to frame and similar work conferming to Fe-410-0 of Fe-310-0,, complete all as specified and directed. |
| 15 | M& L for applying two coats of synthetic enangel paint over a coat of red oxide primer including preparation of newly steel surface of any description over 10 cm width and girth complete all as specified and as directed. |
| 16 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainingbolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and directed. |
| 17 | M&L for Concertina coil galvanised 600mm dia including securing, tying at crossing with provision of galvanized mild steel wire staples or steel pins etc. complete all as specified and as directed. |
| 18 | M&L for Boulder filling Dry, handpacked tighilly, as in wire crate apron bunds (Wire crate measured sepratelycomplete all as specified and as directed. |
| 19 | Supply only wire crate, complete all as specified and as directed. |
| 20 | Demolition of reinforced cement concrete of any description as in fall position & removing Demolished material, complete all as specified and as directed. |
| 21 | Demolition ofcement concrete unreinforced of any description and in any position not otherwise provided, complete all as specified and as directed. |
| 22 | Supply, laying and testing cable XLPE Insulated screened, PVC bedded. galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 16 sq mm 4 core complete all as specified and as directed. |
| 23 | Supply and errection of Prestressed concrete poles size 9 Mtr long 102 mm x Each 172 mm at top and 102 mm x 279 mm at bottoms class-10 including painting 5 Nos of strips in white and black colour 30 cm wide above PCC couping on ground level and numbering complete all as specified and as directed. |
| 24 | Supply and fix in replacement 1 x 70 Watt, LED street light fittings, powder Each coated pressure die cast aluminium compact High power with heat resistant toughened glass with lens, priple locked with built in short circuit protection, over load protection, and surge protection, Highvlow voltage cut off all as specified and as directed by Engr-incharge |
| 25 | Supply and fix PVC flat twin core cable of 6 Sqmm from Junction box to LED Per light complete all as specified and as directed. |
| 26 | Supply and fixing of PVC junction box of size 200x250x 50 mm mounted on GI pipe with MS clamp of suitable size including four pole terminal points mounted on epoxy insulator for cable connection with 01 No MCB SP cap up to 32Acomplete all as specified and as directed. |
| 27 | Excavation in trenches, in hard dense soil not exceeding 1.5 Mtr wide and notexceeding 1.5 Mtr in depth laying of cable or pipes (where provided for protection of cables) etc and getting out trimming the sides, forming bottom surface to required level complete all as specified and as directed. |
| 28 | M & L for sand cushioning with a layer of sand 18 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified 7Cum and directed.Note : only 18cm punned thickness will be measured) |
| 29 | Supply and laying of well burnt bricks, sub class \"B\" laid flat in trenches for protection of cable complete all as specified and directed. |
| 30 | M&L for providing cement concrete 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed by Engr in charge |
| 31 | S & F of tubes light grade of 25 mm bore galvanised with all fitting for cable protection trenches/wall/on pole including necesarry clamps sets and nut & bolts complete all as specified and directed by EIC. |
| 32 | Supply and fix Gl bracket pipe of size 40 mm dia medium grade of 1.0 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of Gl pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including suitable fabricate MS flat iron clamps of 25X6 mm thick-02 Nos suitable for fixing any places with nuts, bolts & washers including grouting on wall etc complete all as specified and directed |
| 33 | Dismantling of PCC poles/struts of any sizes, |
| 34 | Dismantling and taking down street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store (Accessories or components to be provided free for replacement by department) |
| 35 | Dismantling and taking down PVC junction box of any size |
| 36 | Taking up/down old Under Ground cable of any size/type including complete all as specified and directed. |
| 37 | Note:- Deduction for Schedule of credit (Sch \"A\" Part-II) to be made of ₹ 214090.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents. |