| 1 | M&L for cleaning of open channel of X-section area upto 3.5 Sqm and depth upto 1.50 m including removing of all sludge, mud, foreign material, sand, ashes, fibre, silt, grease, night soil etc and removing the taken out sludge / material out side of MoD land by any means/source complete all as specified and directed. |
| 2 | Dismantling of brick work built in cement mortor or cement lime mortar and complete all as specified and directed. |
| 3 | Excavating over area, n exc 1.50 mtr deep and getting out in soft/loose soil all as specified |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not 25 cm in soft soil complete all as specified and directed. |
| 5 | Removing excavated material n.xc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point |
| 6 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation and mass concrete complete all as specified and directed. |
| 7 | M&L M-30 design mix RCC (20mm graded aggregate) foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 8 | M&L for M-30 design mix RCC (20mm graded aggregate) for walls and the like inlcluding pilasterscomplete all as specified and directed. |
| 9 | M&L for M-30 design mix RCC (20mm graded aggregate) including fair finished surfaces for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 10 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams for fair finished on flat/curved surfaces including complete all as specified and directed. |
| 11 | M& L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick fair finished surface complete all as specified and directed. |
| 12 | Fair finished Formwok to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses etc. vertical or to fair finish surfaces including complete all as specified and directed. |
| 13 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 14 | M&L for PVC water stopper (dumbell type) of approved make and quality, confirming to IS-12200, minimum 200mm wide and 6mm thickness, at construction joints between RCC wall and floor including ensuring proper alignment and ambedment, fixing in position during concreting, maintaining laps, jointing by heat sealing as per manufacturer\"s specifications complete in all respects as directed by Engr-in-Charge. |
| 15 | S&F Framed work Fe-290 (Gde E-165) as in covering in chamber or other sectionwith gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or othercovering. Doors, etc. to beprepared for hanging or slidingwith and including either hooksand hinges or steel hangingdoor fittings (exclusive of steelsheeting or other covering,running rails and guides) andhanging; also fastening andfixing complete |
| 16 | M&L for 10mm dia SS welded wire (304 Grade) mesh of size (50mm x 50mm ) complete all as specified and directed. |
| 17 | M & L Brickwork with subclass \"B\" bricks, straight or curved on plan exc 6m mean radious, built in cement mortar1 :6 etc complete |
| 18 | S&F MS shutter (6 mm thick framing with 50 mm channel) having arrangement for opening and closing of water from taping point for the RCC drain (Dimension as per drawing) including two coat of synthetic enamel paint complete all as specified and directed by Engr -in-Charge. |
| 19 | M&L for preparation of new steel surface of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 20 | Demolition ofreinforced RCC of any description and in any position not otherwise specifically provided including removing the demolished material out side MoD land in low laying area complete all as specified and as directed.Notefor item No 1 to 20:- (i) Concreting can be carried out either pumping of concrete or using rail and trolley system for which track shall be laid through the existing drain.(ii) Cost of establishment either for pumping or trolley system included in the quoted rate. (iii) It shall be ensured that concrete shall be as per design mix and compatible with mode of laying. Cost of admixtures such as plasticizer etc included in the quoted rate.(iv) Tenderer are advised to visit the work site by taking prior appointment with GE before quoting the bid. The tenderer shall have no claim whatsover on this account at later stage whether he has actually inspected the work site or not (v) Site photography of existing site is enclosed with the tender documents for reference only.(vi) The length of drain is 1.65 Km (Approx) and all material & manpower shall be mobilized through the existing drain. Contractor shall the plan the work accordingly.(vii) Work shall be carried out as per drawing and items shall be measured & pai as per quoted rate against the item in BOQ. |