| Sl. No. | Item Description |
| 1 | B&R PORTION:Taking up or down steel tubing and connections including cleaning for refixing or removal to stores with all fittings for 15 mm bore GItubings complete all as specified and directed. |
| 2 | Taking up or down steel tubing and connections including cleaning for refixing or removal to storeswith all fittings for 20 mm bore GItubings complete all as specified and directed. |
| 3 | Taking up or down steel tubing and connections including cleaning for refixing or removal to storeswith all fittings for 25 mm bore GItubings complete all as specified and directed. |
| 4 | Taking up or down steel tubing and connections including cleaning for refixing or removal to store with all fittings for40 or 50 mm bore GItubings complete all as specified and directed. |
| 5 | Taking up or down steel tubing and connections including cleaning for refixing or removal to store with all fittings for 80 mm bore GItubings complete all as specified and directed. |
| 6 | S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 15 mm bore GI tubings complete all as specified and directed. |
| 7 | S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 20 mm bore GI tubings complete all as specified and directed. |
| 8 | S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 25 mm bore GI tubings complete all as specified and directed. |
| 9 | S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 40 mm bore GI tubings complete all as specified and directed. |
| 10 | S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 80 mm bore GI tubings complete all as specified and directed. |
| 11 | Refixing old steel tubing and connections of 15 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified and directed. |
| 12 | Refixing old steel tubing and connectionsof 20 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified and directed. |
| 13 | Refixing old steel tubing and connectionsof 25 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified and directed. |
| 14 | Refixing old steel tubing and connectionsof 40 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified and directed. |
| 15 | Refixing old steel tubing and connectionsof 80 mm bore in new or old position ( Walls, ceilings, floors etc) with new fittings etc complete all as specified and directed. |
| 16 | S&F in repair, gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed for 15mm dia pipe (ISI Marked) complete all as specified and directed. |
| 17 | All as per item No 16.00 above but for 20mm dia pipe complete all as specified and directed. |
| 18 | All as per item No 16.00 above but for 25mm dia pipe complete all as specified and directed. |
| 19 | All as per item No 16.00 above but for 40mm dia pipe complete all as specified and directed. |
| 20 | All as per item No 16.00 above butfor 80 mm dia pipe complete all as specified and directed. |
| 21 | Taking down eaves gutter & rain water pipes ( any size or pattern), incl. all fitting, heads , shoes, bends, swan necks, incl cleaning for refixing or removal to store complete all as specified and directed. |
| 22 | S&F mild steel angle iron, flats, tees, mild steel plain black sheet ( 3.15 mm thick in covering) and such similar articles as in framed workfor water tanks covers with necessary welding, riveted and pintol hinges, hold fasts for fixing cover, Handle for lifting complete all as specified, steel work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 23 | Dismantling wrought iron or mild steel work of any description no other wise provided for as in covers of water tanks complete all as specified and directed. |
| 24 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of new steel surfaces complete all as specified and directed. |
| 25 | S&F in repair, brass chromium plated towel ring square with round flange fixed with steel screw on wall complete all as specified and directed. |
| 26 | S&F joist, channels, angles, tees or other sections fixed independently with or without connecting plates, cleats with necessary welding etc as required complete all as specified and directed steel work confirming to Fe-290 Gde E 165) complete all as specified and directed. |
| 27 | Dismantling unframed timber scantlings as in fillets, rails, posts, rafters, purlins etc under 40 sq cm in sectioon complete all as specified and directed by Engr in charge. |
| 28 | M&L for two coats of synthetic enamel painton new wooden surfaces over a coat of pink primer incl preparation of surfaces over 10 cm width of girth complete all as specified and directed. |
| 29 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar andtaking out of trenches if rquired of 100 mm/75 mm internal dia complete all as specified and directed. |
| 30 | S&F 100 mm dia cast ironrain water socketed pipes swith cement joints with out ears, fixed to vertical surfaces with necessary clamps etc complete all as specified and directed. |
| 31 | S&F 75 mm dia cast ironrain water socketed pipes swith cement joints with out ears, fixed to vertical surfaces with necessary clamps etccomplete all as specified and directed. |
| 32 | S&F 75 mm dia cast ironrain water socketed pipes swith cement joints with out ears, laid in trenches or in floors complete all as specified and directed by Engr in charge. |
| 33 | S&F in repairs, cast iron bend or elbow for cast iron rain water pipe of dia 100 mm complete all as specified and directed. |
| 34 | All as per item No 33.00 above but 75mm dia complete all as specified and directed. |
| 35 | S&F in repairs,cast iron branch, single for cast iron rain water pipe of dia 100 mm complete all as specified and directed. |
| 36 | All as per item No 35.00 above but 75mm dia complete all as specified and directed. |
| 37 | S&F in repairs,cast iron offset projection upto 150 mm, for cast iron rain water pipe of dia 100 mm complete all as specified and directed. |
| 38 | All as per item No 37.00 above but 75mm dia complete all as specified and directed. |
| 39 | M&L for uprooting grass/ plants (girth n.exc 15 cm of trunk to any of plants) grown along the pipes or walls chajjas, parapets and roofor any othder location on the building upt sixth storey height including making good the surface as per existing surface and pouring acid not less than 100 ml for each plant in the roof to avoid further growth as directed with necessary scaffolding/ form work required for completion of work upto sixth storey height including all safety factor complete all as specified and directed. |
| 40 | M&L for refixing of shutters of any descriptionin same opening after taking down for resecuring ,easying, repairing or adjusting etcexc 1.0 sqm but n exe 2.0 sqm complete all as specified and directed. |
| 41 | Dismantling floor hearth and wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 42 | M&L for Glazed ceramic walls tiles coloured (450x300mm/300x450), 6/7mm thick, for works on vertical surfaces such as skirting/dados of 1st quality , set and jointed in neat cement slurry and pointed in coloured cement to match including rendering 10mm thick on fair faces or other than fair faces of brick work in cement mortar 1:4, finished even and fair as in backing layer complete all as specified and directed. |
| 43 | M&L for Non skid ceramic floortiles 7 to 8 mm thick (square/rectangular) coloured, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,of 1st quality , set and jointed in neat cement slurry and pointed in coloured cement to match laid over screed bed or bedding layer in cement mortar 1:6, 15 mm thick for laying floor finishes complete all as specified and directed by Engr in charge. |
| 44 | M&L for Non skid ceramic floor tiles 7 to 8 mm thick (square/rectangular) coloured, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,of 1st quality , set and jointed in neat cement slurry and pointed in coloured cement to match laid over renderning cement mortar 1:4, 10 mm thick for laying vertiacal tiles in skirting/dado etc complete all as specified and directed by Engr in charge. |
| 45 | M&L forlight shade vitrified tiles9 to 10 mm thick ( Square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed inneat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bedinCM 1:6 complete all as specified and directed. |
| 46 | All as per item No 45.00 above but as in skirting/dado etc over and includingrenderning 10 mm thick cement mortar 1:4 complete all as specified and directed. |
| 47 | S&F in repair Brass chromium plated toilet paper holder, fixed to wall with CP brass screws complete all as specified and directed. |
| 48 | S&F in repair Stop valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 49 | S&F in repair Stop valves (angle valve type), cast copper alloy, fancy type chromium platedof size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 50 | S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 51 | S&F in repair water closet vitreous china squatting pan of ORISSA pattern size 580 mm X 440 mm white with integral foot rest incl setting the cast iron trap & pan into cement and sand mortar, provn of lime concrete bedding complete.incl valveless syphonicaction type PVC low level flushing cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete all as specified and directed. |
| 52 | S&F in repair vitreous china wash down water closet pedestal pattern white incl valveless syphonic action type PVC low level flushing cistern with inlet ball valve float & handle incl. brackets of 10 ltrs capacity complete with plastic water closet seat white closed pattern with flat bottom & cover & mild steel chromium plated or aluminium hinges device & flush pipe of polythene of low or high density of PVC 32mm dia for low level PVC cistern complete all as specified and directed.Make:HINDWARE/PARRY WARE/CERA) Ist quality. |
| 53 | S&F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type,double button flushing cistern of capacity 10 liters, low level, White with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete including taking down by dismantling the existing unserviceable cistern of any description complete all as specified and directed. |
| 54 | S&F in repair Health faucet Chromium plated brass with 1.50 m long flexible pipe for WC complete all as specified and directed. |
| 55 | S&F in repair Vitreous, China wash basin, white , flat back , size 550x 450mmexcluding taps, waste chain and plug and porcelain stopper but including the brackets, 32mm dia brass chromium plated waste coupling and PVC waste pipe complete all as specified and directed. |
| 56 | S&F in repair Brass CP mixer (Central hole basin mixer) , for mixing hot & cold waterscrewed down for iron pipe 15 mm bore complete all as specified and directed. |
| 57 | S&F in repair PVC mirror cabinet of size 330 mm x 430 mmwith openable single looking mirror with PVC inner & outer shelves of any colour, including taking down old looking mirror & wooden cupboard mirror complete all as specified and directed. |
| 58 | S&F in repair Brass chromium plated soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 59 | S&F in repair Glass self assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromoium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 60 | S&F in repair toughened corner glass shelf 6mm thick with brass chromium plated guard and fixing arrangements complete of size 300 mm complete all as specified and directed by Engr-in-charge.Make: Jaguar Cat Part No CAN-1173 or equivalent of make as in PS. |
| 61 | S&F in repair Brass chromium plated shower rose with swivel joints, 125 mm diawith CP neckincluding fixing to steel pipe or union 15 mm nominal bore complete all as specified and directed. |
| 62 | S&F in repair Bib taps, cast copper alloy, chromium plated, fancy type, long body with crutch or butterfly handle, screwed down screwed for iron pipe, 15 mm bore complete all as specified and directed. |
| 63 | S&F in repair Tubular towel rail 20mm dia \"D\" type brass chromium plated 60 cm long between flanges fixed complete all as specified and directed. |
| 64 | Demolition of cement concrete of any description and in any position,provided for and removing rubbish out of MoD land complete all as specified and directed. |
| 65 | Supply only water proofing compound (PIDIPROOF-LW PLUS) or equivelent complete all as specified and directed. |
| 66 | M&L for Plain cement concrete (1:5:10) type E-2 using 40mm brick course aggregate as in filling under floor as in sunken portion complete all as specified and directed. |
| 67 | M&L for 40mm th PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) as in flooring, finished fair and even, mixed with water proofing compound Dr FIXIT PIDIPROOF-LW PLUS or equivalent (as per manufacturer\"s instruction) as approved by GE complete all as specified and directed.Note : WPC shall be measured and paid separately |
| 68 | M&L for 15mm thick cement plasteringon brick or conc surfaces in CM 1:3 finished even & smooth without using extra cement mixed with water proofing compound Dr FIXIT PIDIPROOF-LW PLUS or equivalent (as per manufacturer\"s instruction) as approved by GE complete all as specified and directed.Note : WPC shall be measured and paid separately |
| 69 | S&F in repair CI nahani trap with grating including jointing to waste pipe , dia of outlet 75mm fixed inPCC 1:2:4 type B1 (ISI Marked) complete all as specified and directed. |
| 70 | Demolition of reinforced cement concrete inroof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work as specified including removal out side MoD land complete all as specified. Note with necessary scaffolding/form work required for completion of work upto sixth storey height including all safety factor complete all as specified and directed. |
| 71 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in mud stops, roof kerbs, moulded or chamfered on edges including necessary form work as required complete all as specified and directed. |
| 72 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including cranking, bending, spirally for hooping for columns, hooking ends and binding with with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 73 | M&L for cleaning RCC OHT of capacity upto 20,000 Ltrs cleaning walls & floors of tanks by wire brushing & gunny bags etc removing all scale, dirt & mud etc and removing out side the MOD land including washing with bleaching powder and painting the internal surface with black japanbituminous paint complete all as specified and directed. |
| 74 | Removal of debrish/malba out side the MD land to any lead, malba accumulated on the roof of block includingstacking of malba and bringing the same to down wards with all safety precautions and cleaning the entire roof surfaces , removal of any vegetation/plants with roots on the roof and making good disturbed surfaces with cement mortar/concrete to match the existing specification during removal of plants etc to the entire satisfication of Engr-in-charge. |
| 75 | M&L for preparation of brick/concrete/existing roof treatment of roof surface by racking out joints of brick terracing tile andcleaning and washing down ORcleaning and washing down of concrete surface and make the surfaces free from dustand other contaminateand providing \"Coral water seal-132 or equivalent of FOSROC water proofing treatment 3 to 5mm thick layers, trowel finished complete all as per manufacturer instruction and directed (application of treatment shall be done through application of the manufacturer) complete all as specified and directed.Make : Coral industries /FORSOC |
| 76 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in flooring (of steps in stair case) finished even and smooth with out using extra cement including making impressions of expanded metal, whilst the concrete is green complete all as specified and directed. |
| 77 | Demolition of cement concrete (unreinforced) of any description in ground floors and paving not exc 15 cm thick below or above ground floors ( as in steps of stair case) including removal of demolished material out side MD land complete all as specified and directed. |
| 78 | M&L for Cutting chases pinning in making good to facings to brick walls if required & pointing in CM 1:3 to ends or edges or edges of landings steps, cills, sunshades shelves & cutting chases for concealed water tubing or concealed water tubing, etc and making good, cutting n.exe 10cm. girth complete all as specified and directed. |
| 79 | S&F in repair 600x450mm bevelled edge mirror of selected quality glass mounted on 6mm thickAC building board or commercial plywood with aluminium beading alround and fixed with steel screw complete all as specified and directed. |
| 80 | Providing & injecting chemical emulsion for post constructional antitermite treatment along external wall below conc or masonry apron using chemical emulsion @ 2.25 ltrs per linear meter incl drilling and plugging holes etc in apron complete all as specified and directed. |
| 81 | Treatment of soil under existing floors using emulsion @ 1 Ltrs per hole, 300 mm apart incl drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and directed. |
| 82 | Providing & injecting chemical emulsion at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 ltrs per hole by drilling holes at a down ward angles of 45 degree at 150mm center to center& sealing to same complete all as specified and directed. |
| 83 | M&L for preparation of old distempered surfaces of wall by complete removal of existing treatment from wall/ceiling surfaces and applying two coats of distemper oil emulssion, white or tinted over one coat of alkali-resistant primer paint and 1.5 mm thick wall care putty complete all as specified and directed by Engr in charge.Note:- (a) All work shall be done mechanicallythrough authorised applicator only. (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer. (c) The contractor shall provide application, testing and certification of finishes by paint manufacturing firms/their authorised applicators (d) cost of above mentioned shall also included in quoted rates. |
| 84 | M&L for preparation of old decorated plastered or unplasteredsurfaces of wall/ceiling including complete removal of existing surfaces by using mechanical scrapersand filling holes with putty etc and applying one coats of white wash on old decorated surfaces of wall/ceiling with necessary scaffolding work required for completion of work upto sixth storey height including all safety factor complete all as specified and directed.Note:- (a) All work shall be done mechanicallythrough authorised applicator only. (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer. (c) The contractor shall provide application, testing and certification of finishes by paint manufacturing firms/their authorised applicators (d) cost of above mentioned shall also included in quoted rates. |
| 85 | M&L for applying one coat of synthetic enamel paint on old decorated wooden surfaces exc 10 cm width or girth, including preparation of surfaces, complete all as specified and directed.with necessary scaffolding work required for completion of work upto sixth storey height including all safety factor complete all as specified and directed.Note:- (a) All work shall be done mechanicallythrough authorised applicator only. (b) Authorised applicator of paint manufactures shall have valid authorisation letter from the manufacturer. (c) The contractor shall provide application, testing and certification of finishes by paint manufacturing firms/their authorised applicators (d) cost of above mentioned shall also included in quoted rates. |
| 86 | S&F in repair 32 mm dia PVC waste pipe for WHB & sink, 60 cm long union complete all as specified and directed. |
| 87 | S&F in repair 15mm spindle for suitable for hot and cold quarter turn concilled stop cock spindle complete all as specified and directed. |
| 88 | S&F in repair 15mm spindle for quarter turn bib cock spindle complete all as specified and directed. |
| 89 | Providing & injecting chemical emulsion at points of contact of wall as above of skirting work by termite chemical emulsion@ 0.5 ltrs per hole by drilling holes at a down ward angles of 45 degree at 150mm center to center& sealing to same complete all as specified and directed. |
| 90 | E&M PORTION:M&L for Preventive maintenance ofDG set (200 kVA - 01 Nos) on quarterly basis installed at Sangli Apartments complete all as specified and directed. The following maintenance to be carried out as under:a) Checking levels of Oil in Fuel Tank Coolant, Gauge Valve and replenish if necessaryb) Re-grease all grease points c) Tightening of Nut-Bolts of pipeline of fuel oil, lubricating oil, water and check for any leakages.d) Check the Water level in Radiator and Top Up the coolant as required.e) Clean Oil Filters/Fuel Filters.f)Check Viscosity of Lube Oil.g) Check Crank case for leakage. h) Cleaning Air Filters.i) Check the Radiator fan belt condition.j) Check Distilled water for Battery and Top-up.k) Check Battery cover condition from cover and Battery Voltage.l) Check the Metering equipment.m) Check the Insulation resistance of alternator. |
| 91 | M&L for \"B\" Check of DG set of 200 kVA capacity at Sangli Apartments location by taking out unsv spares, adjustment belt tension,Tuning of Engine, adjustment of speed, alternator voltage, check the serviceability of AVR, frequency etc, greasing oiling and changing oil,oil filter,fuel filter, bypass filter, Air filter, Water separator and Radiator cleaning with chemical For smooth functioning of DG Set complete all as specified and directed.Note: Any spares, Engine oil, Coolant, Unserviceable spares required to be replaced shall be measured and paid separately under respective items |
| 92 | M& for Servicing of DG Set AMF Panel of 200 kVA Capacity complete including labour for replacement ofu/s spares, testing complete all as specified and directed.Note: unserviceable spares required to be replaced shall be measured paid for separately under respective items |
| 93 | Supply only in replacement of Fan belt suitable for 200 kVA capacity DG Set as per existing complete all as specified and directed. |
| 94 | Supply only in replacement of Diesel Filter suitable for 200 kVA capacity DG Set as per existing complete all as specified and directed. |
| 95 | Supply only in replacement of Oil Filter suitable for 200 kVA capacity DG Set as per existing complete all as specified and directed. |
| 96 | Supply only in replacement of Air Filter suitable for 200 kVA capacity DG Set as per existing complete all as specified and directed. |
| 97 | Supply only Coolant of approved make as per OEM in sealed containers complete all as specified and directed. |
| 98 | Supply only Synthetic Engine Oil (Type : SAE 20W40) of approved make as per OEM in sealed containers complete all as specified and directed. |
| 99 | S&F in replacement of maintenance free Tubular Battery 12V, 180 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge. |
| 100 | S&F in repair Battery Lugs/Connectors of suitable capacity as per the site complete all as specified and directed by Engr-in-Charge. |
| 101 | S&F in replacement of Hose Pipe Set suitable for 200 kVA capacity DG Set complete all as specified and directed. |
| 102 | S&F in repairs to DG Set Control Panel of capacity 200 kVA incl replacement defective sensors like AMF module, relay card/board, current transformer, Key switch , Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge. |
| 103 | S&F in replacement of Battery Charger of 6 Amps rating 12V Battery complete all as specified and directed by Engr-in-Charge. |
| 104 | S&F in replacement of LED Street lightfitting 45 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed.Make : Havells/CG/Philips. |
| 105 | S&F in replacement of LED Street lightfitting 60 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed.Make : Havells/CG/Philips. |
| 106 | S&F in replacement of LED Building security light fitting 25 Watt including GI bracket of suitable size, fixing with clamp, nut, bolt and other connected accessories complete all as specified and as directed. Make : Havells/CG/Philips |
| 107 | S&F in repair IP66/67 (as per IEC 60529) Thermoplastic PC- GFS Polycarbonate Weatherproof, UV resistant due to solar radiation, Rainwater proof, temperature resistant, Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C (as per IEC 60695 – 2 – 11) Junction Box having size (205x255x112 mm) Cat No KF 2525G of Hensel/Equivalent in Rittal/ABB/Siemens, on existing Pole with 1 No. 6 Amp \"B\" Curve series, 10kA SP MCB i/c supply with pole mounting kit for clamping the box on pole, earthling the body connection, inter- connection, suitable terminal blocks, glands, locknut etc. complete set as reqd. for Pole lighting complete all as specified and directed. |
| 108 | M&L in replacement for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch boardtest point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover etc complete all as specified and directed by Engr in charge. |
| 109 | M&L in replacement for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI Wire of 4 mm dia as earthing lead bolted (with GI nuts, bolts & check nuts) and rivetedto earth (Plate) electrode at one end and connected to main switch boardtest point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0using 12 mmgraded crushed stone aggregate, RCC cover etc complete all as specified and directed. |
| 110 | S&F in replacement MCCB 4-Pole, 415 V, 63 Amps with breaking capacity 16 kA complete all as specified and directed. |
| 111 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 100 Amps with breaking capacity 16 kA complete all as specified and directed. |
| 112 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 160 Amps with breaking capacity 25 kA complete all as specified and directed. |
| 113 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 200 Amps with breaking capacity 25 kA complete all as specified and directed. |
| 114 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 kA complete all as specified and directed. |
| 115 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 400 Amps with breaking capacity 36 kA complete all as specified and directed. |
| 116 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 630 Amps with breaking capacity 50 kA complete all as specified and directed. |
| 117 | S&F in replacement MCCB 4-Pole, 415 V, adjustable type 800 Amps with breaking capacity 50 kA complete all as specified and directed. |
| 118 | S&F in repair aluminium lugs of size 50 sqmm complete all as specified and directed by Engr-in-Charge |
| 119 | S&F in repair aluminium lugs of size 70 sqmm complete all as specified and directed by Engr-in-Charge |
| 120 | S&F in repair aluminium lugs of size 120 sqmm complete all as specified and directed by Engr-in-Charge |
| 121 | S&F in repair aluminium lugs of size 150 sq mm complete all as specified and directed by Engr-in-Charge |
| 122 | S&F in repair aluminium lugs of size 240 sq mm complete all as specified and directed by Engr-in-Charge |
| 123 | S&F in repair aluminium lugs of size 400 sq mm complete all as specified and directed by Engr-in-Charge |
| 124 | S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm complete all as specified and directed by Engr-in-Charge |
| 125 | S&F in repair Cable jointing kit for 1100 voltcomplete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed by Engr-in-Charge |
| 126 | S&F in repair Cable jointing kit for 1100 voltcomplete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 t0 185 sqmm complete all as specified and directed by Engr-in-Charge |
| 127 | S&F in replacment wire meshed Hot dip Galvanized cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable,LAN /signal cable ,if require through wall cutting and making to good surface in distrubed area complete all as specified and directed by Engr-in-Charge |
| 128 | M&L in replacement for cable XLPE 240 sqmm, 3.5 core, insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor including laying/ fixing on wall/floor with clip and trunch complete with thimbles complete all as specified and directed by Engr-in-Charge. |
| 129 | All as per item No 128.00 above but for size 150 Sqmm 3.5 Core complete all as specified and directed. |
| 130 | All as per item No 128.00 above but for size 120 Sqmm 3.5 Core complete all as specified and directed. |
| 131 | All as per item No 128.00 above but for size 95 Sqmm 3.5 Core complete all as specified and directed. |
| 132 | All as per item No 128.00 above but for size 70 Sqmm 3.5 Core complete all as specified and directed. |
| 133 | All as per item No 128.00 above but for size 50 Sqmm 3.5 Core complete all as specified and directed. |
| 134 | Excavation in trenches in soft/loosesoil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depthforUG cableetcin soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and directed by the Engineer-In-Charge. |
| 135 | Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by the Engineer-In-Charge. |
| 136 | Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by the Engineer-In-Charge. |
| 137 | M&L for sand cushioning (dry sand) to underground cable for cable protectionlaid in trenches / in existingcable ducts complete all as specified and directed by the Engineer-In-Charge. |
| 138 | M&L for brick laying with subclass \"B\" bricks well burnt, laid dry flat in trenches for protection of cable over cable, complete all as specified and directed by the Engineer-In-Charge |
| 139 | M&L for preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 9 mtr long (410 SP-31) and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole No\"s with paint complete all as specified and directed by ENgr in charge. |
| 140 | S&F in repair LED inverter based 60 watt building security(street light) fitting complete with accessories made of aluminum housing having minimum system efficiency 100 lm/watt operating at full load at AC supply & minimum 20 watt during battery back up , power fractor is equal to or greater 0.95,CCT 6500K, CRI -80, IP-20, inbuilt Li-ion battery for backup, back up to 4 Hrs for complete all as specified and directed. |
| 141 | Supply, Fabrication, and Installation of Panel Box made out of 2.0 mm thick CRCA sheet steel, suitable for housing one no. 630 Amps, 4 Pole, MCCB for main tapping of Busbar Trunking System, complete with hinged door, locking arrangement, rubber gasket for dust and vermin protection, duly powder coated with Siemens grey shade, internal mounting arrangement for MCCB, suitable gland plates, earthing studs, and all necessary hardware. The enclosure shall be designed to provide IP-54 degree of protection as per IS/IEC standards, including taking down old unsv Panel box any type complete all as specified and directed. |
| 142 | Supply, fabrication, and installation of Electrolytic Grade Aluminium/Copper Bus Bars of 800 Amps rating, complete with necessary supports, insulators, hardware, and any size or dimensions as per site requirements, including all necessary fabrication work for proper alignment and connection between the MCCB and Busbar Trunking system. The scope includes drilling, bending, cutting, shaping, providing required connections through suitable lugs, bolts, washers, and insulating sleeves, as per IS/IEC standards including taking down old unsv bus bar complete all as specified and directed.Note: (a) Srl Item No 16.00, 17.00, 25.00, 30.00, 31.00, 42.00, 43.00, 45.00, 47.00 to 49.00, 51.00 to 55.00, 59.00, 61.00, 62.00, 66.00, 71.00, 75.00, 83.00 to 85.00, 104.00 to 107.00, 128.00, 137.00, 140.00 & 141.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail