| Sl. No. | Item Description |
| 1 | Schedule \"A\" |
| 2 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified & directed by Engineer-in-Charge. |
| 3 | Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified & directed by Engineer-in-Charge. |
| 4 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire Excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules, complete all as specified & directed by Engineer-in-Charge. for the following:- |
| 5 | One light/ Bulb Holder/fan/exhaustpoint / bell point controlled by one, one way switch |
| 6 | One light point controlled by 2, Two way switch |
| 7 | One 5 pin socket outlet 5/6 amps on the same board. |
| 8 | One 5 pin socket outlet 5/6 amps on independent board. |
| 9 | Material & Labour for Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 2.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire Excluding modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules, complete all as specified & directed by Engineer-in-Charge. for the following:- |
| 10 | One 16 A socket outlet, independent, with cables 2.5 mm² size |
| 11 | Supply & Fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified & directed by Engineer-in-Charge. |
| 12 | Supply & Fixing in replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified & directed by Engineer-in-Charge. |
| 13 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified & directed by Engineer-in-Charge. |
| 14 | Supply & Fixing in replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified & directed by Engineer-in-Charge. |
| 15 | Supply & Fixing in replacement of modular type 6 Amp bell-push conforming to IS: 8884- 1978 with finger proof terminal, complete all as specified & directed by Engineer-in-Charge. |
| 16 | Supply & Fixing in replacement of Bell multi music type 230 Volt, complete all as specified & directed by Engineer-in-Charge. |
| 17 | Supply & Fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified & directed by Engineer-in-Charge. |
| 18 | Supply & Fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified & directed by Engineer-in-Charge. |
| 19 | Supply & Fixing in replacement of Modular switch 2 way 6 Amp, 1 module, complete all as specified & directed by Engineer-in-Charge. |
| 20 | Supply and fixing in replacement of Modular Flush box, complete all as specified & directed by Engineer-in-Charge.of following size:- |
| 21 | 1 or 2 Module Metal flush box |
| 22 | 3 Module Metal flush box |
| 23 | 4 Module Metal flush box |
| 24 | 6 Module Metal flush box |
| 25 | Supply and fixing in replacement of Modular cover plate with frame, complete all as specified & directed by Engineer-in-Charge.of following size:- |
| 26 | 1 or 2 Module Modular cover plate with frame of size 85mm x 85mm |
| 27 | 3 Module Modular cover plate with frame of size 85mm x 115mm |
| 28 | 4 Module Modular cover plate with frame of size 85mm x 145mm |
| 29 | 6 Module Modular cover plate with frame of size 132mm x 135mm |
| 30 | Supply and fixing in replacement following items for maintenance of Internal Electrification, complete all as specified & directed by Engineer-in-Charge. |
| 31 | Switch piano, flush type single pole, one way 5/6 Amp |
| 32 | Socket Outlet2 in 1, 3 pin, 6 Amp |
| 33 | Socket outlet 2 in 1, 3 pin, 5/6 and 15 Amp flush type |
| 34 | Switch piano, flush type single pole, one way 15 Amp |
| 35 | Switch socket combination, 6 Amps flush type. |
| 36 | PlasterinSwitch socket combination, 16 Amps flush type. |
| 37 | Lamp holder plug for Batten fitting. |
| 38 | Bell push, flush type 5 Amp. |
| 39 | 2.5 mfd Capacitor |
| 40 | Stepped type electronic fan regulator |
| 41 | Top plug 5 Amp |
| 42 | Top plug 15 Amp |
| 43 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unusedway suitable for 12 way type, complete all as specified & directed by Engineer-in-Charge. |
| 44 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unusedway suitable for 8 way type, complete all as specified & directed by Engineer-in-Charge. |
| 45 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unusedway suitable for 4 way type, complete all as specified & directed by Engineer-in-Charge. |
| 46 | Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Casing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified & directed by Engineer-in-Charge.NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Casing capping shall be measured as one length. |
| 47 | 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 48 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 49 | Supply and fixing in replacement of casing capping of 25 x 12mm size, complete all as specified & directed by Engineer-in-Charge. |
| 50 | Supply and fixing in replacement of casing capping of 32 x 16mm size, complete all as specified & directed by Engineer-in-Charge. |
| 51 | Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, complete all as specified & directed by Engineer-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately. |
| 52 | Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified & directed by Engineer-in-Charge. |
| 53 | Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified & directed by Engineer-in-Charge. |
| 54 | Dismantling of BLDC fan (1200mm sweep) motor, taking out unserviceable PCB and replace with new PCB as per existing make andreassembling, complete all as specified & directed by Engineer-in-Charge. |
| 55 | Dismantling of Exhaust fan Plastic Body 250/300mm motor, and replace with new motor and reassembling, complete all as specified & directed by Engineer-in-Charge. |
| 56 | Supply & Fixing in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified & directed by Engineer-in-Charge. |
| 57 | Supply & Fixing in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified & directed by Engineer-in-Charge. |
| 58 | Supply & Fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified & directed by Engineer-in-Charge. |
| 59 | Supply & Fixing in replacement of RGB/Multicolour fountain light LED 9 W, IP 68, Aluminium die cast housing with purity lenses for spot lightning with glare free light distribution enhancing accent lighting, including fixing arrangements, S Connector & T Connectors etc., complete all as specified & directed by Engineer-in-Charge. |
| 60 | Supply & Fixing in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating complete all accessories, complete all as specified & directed by Engineer-in-Charge. |
| 61 | Supply & Fixing in replacement of LED wall light 2x 6 Watts (2700K) and including connected with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fitting in position at site, complete all as specified & directed by Engineer-in-Charge. Make: Wipro Code No DW31227/ Philips/ Havells /CG |
| 62 | Supply & Fixing in replacement of LED decorative Wall mounted fancy Light, Lamp base 1 x E27 type, 7.5 Watts LED Lamp with matt gold finish with borosil glass type and with high illumination indoor wall light LED,including fixing arrangements etc., complete all as specified & directed by Engineer-in-Charge. |
| 63 | Supply & Fixing in replacement of LED picture light fitting Bronze body finish with flexible neck for adjustment beam, 12 Wattand including connected with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting in position at site, complete all as specified & directed by Engineer-in-Charge. Make: Philips Model No: 30973 /Wipro/ Havells /CG |
| 64 | Supply & Fixing in replacement LED Bollard Light Cool White of wattage 11 Watt6500 K with integrated mounting base plate and driver complete with housing dark grey RAL 7043 IP 65 protection, Resistant to corrosion and Better optics for uniform distribution including PCC (1:2:4) foundation of suitable size for mounting of light fitting, complete all as specified & directed by Engineer-in-Charge. Make:Wipro Cat No:LB13-131-XXX-65-08 or equivalent in Philips |
| 65 | Supply and fixing in replacement post top lantern LED type 40 watt 230 volts AC outdoor type (Warm/Cool White) with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified & directed by Engineer-in-Charge. Make :Wipro or equivalent in Philips/Crompton Greave |
| 66 | Supply & Fixing in repair wall/surface mounted LED Bulk head of capacity 10 Watt IP 65 Protection, complete all as specified & directed by Engineer-in-Charge. Make :Wipro, Cat No:LW07-141-XXX-57-G1or its equivalent in Philips |
| 67 | Supply & Fixing in repair surface mounted LED hanging light 20 W 4000K with die cast housing finished in white powder coating complete all accessories, complete all as specified & directed by Engineer-in-Charge. Make :Wipro, Cat No:LD30-201-60W-40-PL or its equivalent in Philips |
| 68 | Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and re-fixing in situ, complete all as specified & directed by Engineer-in-Charge. Note- worn out parts shall be measured as separately. |
| 69 | Supply & Fixing in replacement of spare parts for Geyser |
| 70 | Heating element 1.5 KW with rubber gasket. |
| 71 | Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked. |
| 72 | Hot/Cold water connection pipe 450mm length. |
| 73 | Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia |
| 74 | Indication lamp red and green suitable for geyser as required |
| 75 | Material and labour for maintenance of solar water heating system flat plate type incl all water and electric connections of capacity 100 Ltrs per day and re-fixing the same in existing position after the following repairs and testingcomplete :- Location : Inaz Vig. (a) Replacement of the worn out/missing nuts bolts, washers, unions, sockets flanges and screw etc complete.(b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaningand washing all copper tube & water circulated pipes of heat convector sets thoroughly cleaning the complete solar pannel of making the tube scale free andre-assembling the pannel.(c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete.(d) Repair of collector fins incl required welding works etc complete.(e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects.Note : Cost of dismantling and re-fixing and minor repairs deemed to be included in quoted rate. |
| 76 | All as per item No. 42 here in before but of capacity 200 ltrs per day, complete all as specified & directed by Engineer-in-Charge. |
| 77 | All as per item No. 42 here in before but of capacity 300 ltrs per day, complete all as specified & directed by Engineer-in-Charge. |
| 78 | Material and Labour for painting the MS supporting structure of solar water heating system complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., complete all as specified & directed by Engineer-in-Charge. |
| 79 | Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, re-fixing the front cover of indoor unit. Remove the outer cover of outdoor unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressurized water then apply one coat of descaling solution and clean with wire mesh brush/nylon brush to the condensing coil of outdoor unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified & directed by Engineer-in-Charge.Note:- Replacement of defective parts with new parts shall be measured and paid separately under respective items in the schedule. |
| 80 | Material & Labour for detecting the cause of leakage in any type/capacity of 1.5/2ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning, complete all as specified & directed by Engineer-in-Charge.Notes :-(i) Dismantling of unserviceable compressor, cost of refrigerant gas and re-installation of serviceable compressor after repairing are deemed to be included in the quoted rates. |
| 81 | Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load, complete all as specified & directed by Engineer-in-Charge. |
| 82 | Supply & Fixing in repair over load protector suitable range and capacity |
| 83 | Supply & Fixing in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply |
| 84 | Supply & Fixing in repair capacitor of 2.5 mfd suitable for blower fan motor of 1.5/2.0 ton AC |
| 85 | Supply & Fixing in repair thermostat switch of suitable for 1.5/2.0 ton AC |
| 86 | Supply & Fixing in repair Contactor relay of suitable for 1.5/2.0 ton AC |
| 87 | Supply & Fixing in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete |
| 88 | Supply & Fixing in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete.Make:- LG/ Blue star / Voltas or as per existing make of AC at site. |
| 89 | Supply & Fixing in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete |
| 90 | Supply & Fixing in repairs PVC fan blower assembly for 1.5 /2TR split AC\"s any make |
| 91 | Supply & Fixing in repairs Printed circuit board (PCB) with suitable for non-inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection. |
| 92 | Material & Labour for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC\"s of the following capacity, complete all as specified & directed by Engineer-in-Charge. of the following capacity |
| 93 | 1.5 ton capacity |
| 94 | 2.0 ton capacity |
| 95 | Supply & Fixing in repairs Condenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified & directed by Engineer-in-Charge. |
| 96 | Supply & Fixing in repairs Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified & directed by Engineer-in-Charge. |
| 97 | Supply & Fixing in repairs Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified & directed by Engineer-in-Charge. |
| 98 | Material & Labour for replacement of outdoor condenser unit of copper with 2 run of copper pipe of outdoor unit of split type AC 1.5/2.0 TR, complete all as specified & directed by Engineer-in-Charge. |
| 99 | Material & Labour for replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit of split AC, complete all as specified & directed by Engineer-in-Charge. |
| 100 | Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type, complete all as specified & directed by Engineer-in-Charge. |
| 101 | Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of PVC Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type, complete all as specified & directed by Engineer-in-Charge. |
| 102 | Supply & Fixing in repairs copper tubing of size 3/8\" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified & directed by Engineer-in-Charge. |
| 103 | Supply & Fixing in repairs copper tubing of size 5/8\" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified & directed by Engineer-in-Charge. |
| 104 | Supply and fix in repair flexible PVC pipe for condense water outlet for Split AC as per existing, complete all as specified & directed by Engineer-in-Charge. |
| 105 | Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified & directed by Engineer-in-Charge. |
| 106 | All as per item no. 60 above but for 2.0 ton capacity complete as per manufacturer instructions complete all as specified & directed by Engineer-in-Charge. |
| 107 | Supply & Fixing in replacement of outdoor unit stand of metal including fixing accessories such as nut bolt washers and fastener for 1.5/2 Ton outdoor unit, complete all as specified & directed by Engineer-in-Charge. |
| 108 | Material & Labour in replacement of internal remote assembly cordless type suitable for split air conditioner with replacement of PCB, LED indicator and other micro components, complete all as specified & directed by Engineer-in-Charge. |
| 109 | Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location, re-fixing of same AC at new location, complete all as specified & directed by Engineer-in-Charge & detail as under:-(a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface.(d) Concealing of refrigerant pipe with PVC flexible pipe. (e)Extension of pipe due to site condition if required shall be measured and paid separately under respective items taken before. |
| 110 | Supply & Fixing in replacement of AC 1.5 Ton new outdoor unit suitable for existing AC and re- installing split type AC at site and including re-fixing of outdoor unit on wall and outdoor unit an wall mounted including bracket of MS and replacement of refrigerant tubing as per site std requirement upto 6 RM, any insulated complete, including taking down old ODU, complete all as specified & directed by Engineer-in-Charge.Make Voltas/Carrier/HitachiNote- (i) Gas charging if required deemed to be included in unit rate. (ii) 20mm dia PVC conduit fixing for waste water as per required deemed to be included in unit rate. |
| 111 | Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity (Ltrs/hr) 80/40 & 120/60 litres with the use of anti-scaling agent for internal steel water tank, outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush, cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipment’s, cleaning of fins and tubes of condenser, repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap, complete all as specified & directed by Engineer-in-Charge. |
| 112 | Supply and fixing in replacement of hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, complete all as specified & directed by Engineer-in-Charge.Make: Copeland/Tecumseh.Note: Cost of cutting of existing worn out compressor will be deemed to be included in unit rate. |
| 113 | Taking out burnt unserviceable condenser fan motor, and replacement with new electric motor, single phase 230V of water cooler 40ltrs/hrs with condenser fan blade, complete all as specified & directed by Engineer-in-Charge. |
| 114 | Supply and fixing in replacement of following items of water cooler |
| 115 | Thermostat for water cooler capacity 40/80 ltr/hrs. |
| 116 | Push type Bib tap Cast copper alloy 15mm Push type chromium plated. |
| 117 | PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15mm dia GI Pipe. |
| 118 | Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refrigerator in good working condition, complete all as specified & directed by Engineer-in-Charge.Note: Defective spares required for replacement shall be measured and paid separately under respective items. |
| 119 | Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load, complete all as specified & directed by Engineer-in-Charge. |
| 120 | Supply & Fixing in repair condenser suitable forRefrigerator of 195/ 250/ 300 ltr cap |
| 121 | Supply & Fixing in repair cooling effect transmitting fan motor suitable for Refrigerator of 195/ 250 / 300 ltr cap |
| 122 | Supply & Fixing in repair Compressor Relay suitable for Refrigerator of 195/250 / 300 ltr cap or as per existingMake KCL/ Rentrol / Indofos |
| 123 | Supply & Fixing in repair thermostat suitable for Refrigerator of 195/250 / 300 ltr cap |
| 124 | Supply & Fixing in repair Compressor suitable for Refrigerator of 250 / 300 ltr cap or as per existing |
| 125 | Material & Labour for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instructions after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified & directed by Engineer-in-Charge. |
| 126 | Refrigerator cap 230/250 Ltrs |
| 127 | Deployment of manpower, instrument, tools, and all connected accessories for testing of earth resistance of existing Earthing at provided earth test point for each earth set by competent calibrated digital earth test meter electronic type along with accessories (earth rod set with Cu wire with clips) and recording the result dully signed with date by MES representative and contractor, complete all as specified & directed by Engineer-in-Charge.NOTE:- (a) Testing of each Earthing shall be carried out at the interval of 3 months and measurement shall be done each time separately and test result shall be maintained dully signed with date by MES representative and contractor. (b) Pouring of water in each earth pit is deemed to be included in the rate quoted.(c) Necessary arrangement to be made by the contractor for pouring the water in earth pits.Vehicle reqd for carrying/storage of water (upto to the site) with helper will be arranged by contractor and deemed to be included in the rate quoted.(d) Cost of Maintenance of carrying vehicle (if any) and cost of fuel reqd for veh is deemed to be included in the rate quoted. |
| 128 | Supply and fixing in repair Test point terminal block made of gun metal or phosphorus bronze size of 75mm x 75mm x 25mm drilled and screwed with 3 Nos 8mm dia, 25mm long screw, fixed in andincluding SMC junction box of size 170 x 170 x 105mm hinged door fixed on wall, complete all as specified & directed by Engineer-in-Charge. |
| 129 | Material & Labour for PCC Earthing pit in PCC 1:2:4 type B-1 of internal size 300 mm x 300 mm x 300 mm with 120 mm thick wall and 700mm x 700 mm x 150 mm thick bed concrete and 50 mm thick precast chamber cover of RCC 1:2:4, type B1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), complete all as shown in the electrical plate No 3 of SSR part –I including demolition of old pit complete. |
| 130 | Supply and fixing in repair mild steel galvanised earth strip of size 25 x 4 mm with epoxy insulators and fixing screws etc., for earth continuity conductors to test point terminal including taking down old strip, complete all as specified & directed by Engineer-in-Charge. |
| 131 | Material & Labour for marking of Earthing pit (GI earth / Copper earth / Chemical earth) with two or more coat synthetic enamel paint, colour & pattern as approved by the Engr-in-Charge, Letter size shall not be less than 50 mm, complete all as specified & directed by Engineer-in-Charge. |
| 132 | Material & Labour for bore Earthing 150mm bore for Earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe not less than 1.25 metres below ground level, connected with Earthing lead of 25 x 4mm GI strip to the Earthing test point and filling of charcoal dust, salt etc., and testing on completion, complete all as specified & directed by Engineer-in-Charge.Note: IR Value should be less than 5 Ohms.Note: GI earth strip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate. |
| 133 | Material and labour for single electrode chemical Earthing. The chemical Earthing as shown in sketch No.02 will have specification as follows :-(a) Copper electrode of wall thickness minimum 2mm not less than 3.3 mtr length with not less than 75mm outer dia. filled with maintenance free chemical compound & copper strip of size 50x6mm upto 0.15 mtr above ground electrode.(b) Fixing of copper Earth Electrode by drilling / boring 250mm dia hole, upto 05.00 mtr deep in any type of strata, placing electrode in hole, return filling excavated soil by mixing min 20 kg GEL and 100 kg Soil Resistivity Improvement (SRIP) compound as per manufacturer instruction. (Boring in additional after 05 mtr length as per site requirement shall be measured and paid separately.)(c)FRP Earthing result display board 254 x 380mm made out of plastic material showing information related to type of Earthing, Earthing result, due date of testing along with fixing size 610mm height made of plastic solid pipe of dia 20mm. |
| 134 | (d) PCC Earthing pit in PCC 1:2:4 type B-1 of internal size 300mm x 300mm x 300mm with 120mm thick wall and 700mm x 700mm x 150mm thick bed concrete and 50mm thick precast chamber cover of RCC 1:2:4, type B-1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm),complete all as shown in the electrical plate No 3 of SSR part –I complete.(e) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work.(f) Contractor must produce the certificate from the manufacturer that chemical Earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical Earthing.(f) Contractor must produce the certificate from the manufacturer that chemical Earthing has been carried out by manufacturer. The manufacturer must also mention the warranty for chemical Earthing.(g) Extension strip from electrode strip up to 0.15 m height from GL to be deemed included in quoted rate including brazing(h) The Earthing result will be obtained for each electrode must be less than 3Ω.Otherwise contractor is liable to do chemical Earthing to meet the result.Make :- Powertrac / PRAGATI / McML\"s Earthing Solution (MES) / Ashlock |
| 135 | Note :- (I) Quoted rates shall be deemed to including boring hole up to 5 meter deep from ground level.(ii) In case additional depth of boring is required and directed by Engineer-in-Charge same shall be carried out by the contractor and will be measured & paid separately under respective of this BOQ.(iii) Additional length of copper strip (50mm x 6mm) required due to increase in depth of boring will also be measured & paid separately under respective of this BOQ.(iv) Deployment of manpower, tools / machinery etc, and all connected accessories for drilling bore of 175mm dia and depth exceeding 5 metre but not exceeding 10 metre below ground level in any kind of soil / strata including hard stone / boulder etc., complete all as specified and directed by Engr -in -charge. |
| 136 | Material and labour for painting of the transformer 100 KVA to 400 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., complete all as specified and directed by Engr-in-Charge. |
| 137 | Taking out UNSV HT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge. |
| 138 | Supply, Laying, connecting, testing and commissioning and jointing, HT underground cable of size 120 sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, complete all as specified and directed by Engr-in-Charge. |
| 139 | Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed by Engr-in-Charge.Make-Denson/Raychem/3M |
| 140 | Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed by Engr-in-Charge.Make-Denson/Raychem/3M |
| 141 | Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminiumconductor cable of size 120 to185 Sqmm, complete all as specified and directed by Engr-in-Charge.Make-Denson/Raychem/3M |
| 142 | Supply & fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminiumconductor cable of size 120 to185 Sqmm, complete all as specified and directed by Engr-in-Charge.Make-Denson/Raychem/3M |
| 143 | Supply & fixing in replacement air break switch triple pole, 11KV, mechanically operated mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 400 amps complete withincluding insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceable air break switch, jumper connections and reconnecting of suitable size and length and making connection to new AB switchgang operated, complete all as specified and directed by Engr-in-Charge.Make: Jaipuria/ Atlas/Pactil |
| 144 | Preventive Maintenance and Servicing, 11/0.433 KV Step down Transformer Indoor and Oil Cooled type by disconnecting carefully electric connection on primary & secondary side, Checking both side HT bushing, bushing rod, opening top cover of the transformer by unscrewing nuts, bolts, washers etc., rectify the oil leakages issues, if noticed any from the entire body of the transformer, during servicing and re-fixing the top cover of transformer according to previous system. Servicing of the transformer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each transformer to the Engr-in-Charge. Note 1. :-Inspection of transformer shall involve :-(a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc.(b)Checking all brazing’s, joints, tap heads, gaskets and connection joints.(c)Checking all terminations / connections inside/outside the transformer.(d)Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding.(e)Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge.Note 2. :Spares used bushes studs HT/LT, bushing rod HT/LT, transformer oil, filtration of oil, buchholtz relay, Gaskets set, Off Load Change over switch etc., will be measured and paid separately under respective item of BOQ.Note 3 :- The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement. |
| 145 | 100 to 400 KVA |
| 146 | Material & Labour for Dehydration/Filtration of transformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, complete all as specified and directed by Engr-in-Charge. |
| 147 | Material & Labour for Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, complete all as specified and directed by Engr-in-Charge.(Oil should be supplied in sealed barrel of Power/Transol brand)Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations. |
| 148 | Supply & fixing in replacement Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating, complete all as specified and directed by Engr-in-Charge. |
| 149 | Material & Labour for Maintenance/Over hauling of HT VCB 11 KV (1 No incoming, 1 No outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT VCB by employing the Skilled trades man and helper, complete all as specified and directed by Engr-in-Charge.Note: Rate Include following (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unserviceable indicator lamps as per colour code all as specified and as directed by Engineer- In - Charge. (ii) Rack out /Down the HT VCB kept in Test position, Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of Earthing connection by Earth megger note down the readings. |
| 150 | Supply & fixing in replacement of HT 11 KV drop out fuse assembly with insulator and base including fuse tube, fuse carrier top connectors incoming and outgoing connectors, complete all as specified and directed by Engr-in-Charge.(Note: Rate include taking down existing unserviceable/ Faulty DO fuse assembly and fix the new one and make the incoming and outgoing connections and switch on the supply through the new DO fuse assembly all as directed by EIC) Make: Jaipuria/ Atlas/Pactil |
| 151 | Supply & fixing in replacement of connect lightening arrestor nonlinear, pole type 11 KV discharge capacity 65 KA, with all fittings suitable for 11 KV electric working pressure including strap, bolts, nuts and washers etc., complete all as specified and directed by Engr-in-Charge.Make - BHEL / Jaipuria/ Rashtriya/ MEI/National |
| 152 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, complete all as specified and directed by Engr-in-Charge. |
| 153 | Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 154 | Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 155 | Material & Labour for cutting existing road/hard standing not exceeding 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:2:4; including removal of surpluses soil, complete all as specified and directed by Engr-in-Charge. |
| 156 | Servicing of DG set (\"C\" Check) of Cap 20 KVA to 70 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge.(a) Lub oil filter.(b) Lubrication oil.Make of DG set: Ashok Leyland/ Greaves Cotton/ kirloskarNote: Defective parts if any other than listed at (a) to (b) above will be measured and paid separately |
| 157 | Supply only parts/ Items of DG set 50/62.5 KVA (Make : Greaves Cotton & Kirloskar) |
| 158 | Fuel Filter cum water separator |
| 159 | Oil Filter |
| 160 | Air Filter Safety |
| 161 | Air Filter Primary |
| 162 | Fuel strainer |
| 163 | Engine Oil |
| 164 | Coolant |
| 165 | Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 20 KVA to 70 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint, complete all as specified and directed by Engr-in-Charge. |
| 166 | Material & Labour for apply two coat of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubbing of dust etc., and apply one coat of epoxy based primer before painting, complete all as specified and directed by Engr-in-Charge.Note: Minor repair/ replacement of hinges suitable for screw fasteners and fixed in original position deemed to be included in unit rate. |
| 167 | Material & Labour for preparation of old painted surfaces of Steel Tubular pole upto 9 Mtr long by scarping old paint and applying Single coat of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and Blue stripes each 30 cm (5 Strips) apart up to 1.5 Mtr height and including one coat white distempering for pole foundation above ground level shall deemed to be included in the quoted rate etc., complete all as specified and directed by Engr-in-Charge. |
| 168 | Supply & fixing in replacement of Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor, complete all as specified and directed by Engr-in-Charge. cable offollowing sizes-Make-Denson/Raychem/3M, |
| 169 | 25 sqmm to 50 sqmm |
| 170 | 70 sqmm to 120 sqmm |
| 171 | Taking out UNSV LT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge. |
| 172 | Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, complete all as specified and directed by Engr-in-Charge.of cross-sectional area:- |
| 173 | 16 Sqmm 4 Core |
| 174 | 25 Sqmm 4 Core |
| 175 | 50 Sqmm 3.5 Core |
| 176 | 95 Sqmm 3.5 Core |
| 177 | Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables complete with coupler and connected accessories, including taking down old unserviceable DWC pipe, complete all as specified and directed by Engr-in-Charge. Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate.Make: Rex/Poly/Gemini,of following sizes:- |
| 178 | 50/38mm |
| 179 | 63/50mm |
| 180 | 90/76mm |
| 181 | Supply & fixing in replacement of MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cables with proper lugs and glands, complete all as specified and directed by Engr-in-Charge. of following sizesMake: Havells/ L&T / ABB /Schneider |
| 182 | MCCB 63/100 Amp FP, 415 V breaking capacity 25 KA |
| 183 | MCCB 200 Amp FP, 415 V breaking capacity 36 KA |
| 184 | Supply & fixing in replacement street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engr-in-Charge. |
| 185 | Supply & Fixing in replacement of LED flood Light fitting 150 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description, complete all as specified and directed by Engr-in-Charge. Make:Wipro/Philips/Crompton |
| 186 | Supply & fixing in replacement of Multi standard Copper Conductor cable of size 1.5 Sqmm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc., complete all as specified and directed by Engr-in-Charge. |
| 187 | Supply & fixing in replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engr-in-Charge. Make: Wipro or equivalent from Bajaj/Philips |
| 188 | Supply & fixing in replacement Aluminium lugs long barrel of size 50 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent |
| 189 | Supply & fixing in replacement Aluminium lugs long barrel of size 25 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent |
| 190 | Dismantling mono-block pump set centrifugal type of cap 20 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, re-fixing the same at site incl. electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. (Note : Cost of dismantling and re-fixing deemed to be included in quoted rate) |
| 191 | Material & Labour for Cleaning of semi underground RCC sump of capacity 1,00000 gallons thoroughly removing mud, grits etc. from the sump by following method: -(a) Removing all dirt, mud with the help of containers manually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n. exc. 50 mtrs.(c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars and floor & removing mud and grits & deposits etc properly. (d) Repair/Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof.(e) Dry washed walls, coating with a one coat of white cement inside the whole surface of walls/pillars and floor of sump. Note: 1. Consumption of bleaching powder for cleaning of tank shall not be less than 60 Kgs, deemed to be included in unit rate.2. Minor repair/ replacement of inlet & outlets of any type / size of pipes, fixed in original position deemed to be included in unit rate. |
| 192 | Pumping out sewage water from the existing sumps/tanks of STPs (MBBR technology) with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with tanking out mud/ solid sludge from the tank complete from solid separation chamber, aeration chamber and dispose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the main non clogging pump sets installed in the STPs, complete all as specified and as directed by Engineer-in-Charge. Location : CGRA IanzNote :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work.(b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of outside the fencing /wall of STPs towards the main gravity dropping main hole.(c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative.(d) Necessary man power to operate the pump set are deemed to be included in the rate.(e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set.(f) Rate included for transportation of pump set to site/back. |
| 193 | Material & Labour in PP floating media to top up for bio reactors, complete all as specified and directed by Engr-in-Charge. |
| 194 | Carry out water testing of bacterial, chemical and biological analysis of sewage water treated water from NABL accredited Govt approved lab for following parameters and submission of test reports all as directed.Location : CGRA Ianz(a) PH(b) Chemical Oxygen demand/COD(c)Biological Oxygen Demant/BOD(d) Total Suspended solids(e) Oil and grease(f) TKN(g) Total Coliform(h) Organism MPN(k) Dissolved OxygenNote: Every Quarterly water testing shall be carried out as per CA Qty in period of contract all as directed without fail else recovery will be made at Rs 15000/- per test for execution of item and for non-submission of Test Report. |
| 195 | Water Testing, Collecting the sample of water at Pump house andtesting of water for iron, PH value, TDS, colour,Total Hardness, chloride, Chlorine,fluoride, Coliform, arsenic test andsubmitting the test report from reputed laboratory, complete all as specified and directed by Engr-in-Charge. Location : CGRA Ianz |
| 196 | Supply only Hypochlorous Acid net wt 38 kg, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % and delivered at STP, complete all as specified and directed by Engr-in-Charge. Make: Aditya birla or equivalent |
| 197 | Supply only bleaching powder suitable for water disinfection, complete all as specified and directed by Engr-in-Charge. |
| 198 | Dismantling Sewage submersible pumping set of cap 3 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge re-fixing the same at site including. Electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. (Note : Cost of dismantling and re-fixing deemed to be included in quoted rate) |
| 199 | Dismantling Sewage submersible pumping set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge re-fixing the same at site including. Electric and piping connections complete, checking for satisfactory working, complete all as specified and directed by Engr-in-Charge. (Note : Cost of dismantling and re-fixing deemed to be included in quoted rate) |
| 200 | Taking down air blower of Air blowers with working pressure 0.3 Kg/cm2 along with motor of capacity 5 HP with blower pipe of size 3\", from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower thoroughly including machine work and re-assembling the air blower and commissioning testing complete on full load, complete all as specified and directed by Engr-in-Charge.(new spares will be measured and paid separately). |
| 201 | Material & Labour for taking out & servicing of existing unserviceable Air Blower (of any Make) of capacity 5.00 HP pressure 0.3 Kg/cm2with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer-in- charge.Note- (i) Spare part required for replacement shall be measured and paid separately under relevant items (ii) Replacement of Oil seal, locking arrangement of pully, gland packing with oil and greasing shall be deemed to be including in the quoted rate of this item. |
| 202 | Supply & fixing in replacement of \"V\" Belt (SPA 1250) unserviceable /worm-out \"V\" belt of air blower etc, complete all as specified and directed by Engr-in-Charge. Makes:-Fenner/Dunlop/Nerlon/Super flix/Ecodrive. |
| 203 | Material & Labour in replacement of Gear oil 90 EP, Pressure Gear Oil etc., complete all as specified and directed by Engr-in-Charge. |
| 204 | Supply & fixing in replacement air-filter for blower suitable size for existing air-filter etc, complete all as specified and directed by Engr-in-Charge. |
| 205 | Supply only Grease 30K, for using ensure protection of metal surfaces extending bearings, Hinges etc., complete all as specified and directed by Engr-in-Charge. |
| 206 | Material & Labour for finding out defect of STPs panel and taking out burnt interconnection wiring including U/S and serviceable component for re-use including rewiring of panel using existing size of copper cable, ferrule, lugs, insulating materials, nut bolts washer of various sizes re-fixing serviceable items, complete all as specified and directed by Engr-in-Charge. |
| 207 | Supply and laying in replacement of CPVC pipes of size 50mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc., fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and directed by Engr-in-Charge. Make: Supreme/Astral/Finolex |
| 208 | Supply and laying in replacement of CPVC pipes of size 32mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and directed by Engr-in-Charge. Make: Supreme/Astral/Finolex |
| 209 | Supply and laying in replacement of CPVC pipes of size 25mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good, complete all as specified and directed by Engr-in-Charge. Make: Supreme/Astral/Finolex |
| 210 | Supply & fixing in replacement of Ball Valve of 50mm Dia Long Handle of size Supply and laying in replacement and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration any required for fixing and making good, complete all as specified and directed by Engr-in-Charge. Make: Supreme/Astral/Finolex |
| 211 | All as per above Item 135, but size 32mm dia, complete all as specified and directed by Engr-in-Charge. Make: Supreme/Astral/Finolex |
| 212 | All as per above Item 135, but size 25mm dia, complete all as specified and directed by Engr-in-Charge. Make: Supreme/Astral/Finolex |
| 213 | Supply & fixing in replacement of cast iron foot valve assembly complete of suitable size for pipe of size 150mm bore, complete all as specified and directed by Engr-in-Charge. |
| 214 | Supply & fixing in replacement of non-return valves (NRV) body grey cast iron of size 50mm bore, with all fittings confirming to IS specification, complete all as specified and directed by Engr-in-Charge. |
| 215 | Comprehensive maintenance of RO Water Plant of capacity 2000 Ltr/Hr servicing complete:(a)Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (b) Major parts will be measured and paid separately Make of RO Plant : Ion Exchange |
| 216 | Supply & fixing in replacement of following spares for RO water Plant 2000 Ltr/Hr :- |
| 217 | 20\" Sediment filter |
| 218 | Anti-sealant chemical |
| 219 | Membrane |
| 220 | Solenoid Valve |
| 221 | Sand filter media |
| 222 | Carbon media |
| 223 | Comprehensive maintenance of RO Water Plant of capacity 150 Ltr/Hr servicing complete:(a)Replacement of minor parts such as SP stem, union male elbow, branch etc deemed to be included in quoted rate (b) Major parts will be measured and paid separately Make of RO Plant : Ion Exchange |
| 224 | Supply & fixing in replacement of following spares for RO water Plant 2000 Ltr/Hr :- |
| 225 | 20\" Sediment filter |
| 226 | Carbon block |
| 227 | Membrane |
| 228 | Anti-sealant chemical |
| 229 | Solenoid Valve |
| 230 | Design, supply, erecting, installing, testing and commissioning in replacement of Solar PV panel of 0.335 KWp capacity including solar grade DC copper cable upto UPS, array junction boxes & solar panel with anti-glare coating with Si-Monocrystaline or its latest type PV Module on existing roof top structure meeting the specifications as directed.(a) Multi crystalline silicon solar PV modules of not less than 335 Wp eachhaving efficiency more than or equivalent to 15.63% at standard test condition, fill factor more than 0.74 plant performance ratio more than or equivalent to 75% & made of high transitivity glass and glassfront surface shall give high encapsulation gain. (Transmittance above 90% and bending less than 0.3%) Electrical parameters of 340 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum & temperature 25 degree centigrade will be as under- Max Peak power Pmax: ≥335 WpPower Tolerance :0 ~ +5Current at Pmax Impp: 8.33 AVoltage at Pmax Vmpp: 36.90 VoltShort circuit current Isc: 9.05 AOpen circuit voltage Voc: 45.70 Volts (i) It shall perform satisfactorily in relative humidity85±5% with temperature - 40 °C to +85°C (Cell) and should withstand wind 150 Km/Hr on the surface of the panel. (ii)PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 5 years and 80% of the initial value at the end of 25 years. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail