| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth & getting out in soft soil complete all as specified and directed. |
| 2 | Removal of excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and directed |
| 4 | Earth filling under floors with excavated soil incl, spreeding levelling in layers n.exc 25cm thick each and well ramming including water as required and removal of the excavated materil complete all as specified and directed. |
| 5 | M&LPCC 1:4:8, type D-2, using 40mm graded stone aggregate as in foundations, fillings and Mass concrete complete all as specified and directed |
| 6 | M&L brick work with fly ash old size bricks, straight or curved on plan exceeding6 cm mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 7 | M&L40mm thick Damp proof course in cement concrete 1:2:4, type B-0, horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 8 | M&L RCC(Design mix) M-25 (20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 9 | M&L RCC(Design mix) M-25 (20mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed |
| 10 | M&LRCC(Design mix) M-25 (20mm graded aggregate) as in roof beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 11 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 12 | M&L75mm thick, PCC 1:3:6 type C-2(using 40 mm graded crushed stone aggregate) as in sub base of floorscomplete all as specified and directed. |
| 13 | Reinforcement TMT Steel bars of grade Fe-500/Fe-500 D of 10mm dia and over, cut to length, bent to shape required, incl cranking,bending , spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed |
| 14 | All as described ser item no 13.00 here-in-before but5mm dia & over upto & including 10mm dia in stirrups, spacers & binders complete all as specified and directed |
| 15 | Formwork for rough finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam and similar work; vertical or to batter complete all as specified and directed |
| 16 | Formwork for rough finished surfaces to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed |
| 17 | Formwork for rough finished surfaces to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed |
| 18 | Formwork for rough finished surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work complete all as specified and directed |
| 19 | Use & waste of form work for rough finished surface to edges of concrete flat, break in floor cills, railings etc. & similar works, exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 20 | M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfacesfinished even and smooth without using extra cement complete all as specified. |
| 21 | M&L for cement plaster in CM 1:4 in two layers (10+5) first coat 10mm thick in CM 1:6 and second coat 5mm thick in CM 1:4 using WPC in second layer on brick work or concrete surfaces finished even and fair complete all as specified and directed. |
| 22 | M&L for rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed. |
| 23 | Supply only integral water proofing compound only complete all as specified and directed |
| 24 | M&L for preparation of newly plaster surface and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed |
| 25 | M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 26 | M&L for three coats of white wash on newly plastered surface or unplastered surfaces of ceiling including preparation surface complete all as specified and directed. |
| 27 | S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles laid over and including 15mm thick screed bed or bedding layer CM 1:6 for laying floor finishes complete all as specified and directed |
| 28 | S&F coloured Glazed ceramic tiles in vertical surfaces (450x300x7mm) set and jointed in neat cement slurry and pointed in white or coloured cement to match as in vertical surfaces including 10mm thick back coat in CM 1:4 complete all as specified and directed. |
| 29 | S&F 15mm bore medium grade GI tubes with all fittings and fixed complete to walls or laid in floor complete all as specified and directed |
| 30 | All as described ser item no 29.00 here-in-before but 20mm dia complete all as specified and directed |
| 31 | S&F 20mm dia stop valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed down both ends for iron pipe or for brass ferrule fixed complete all as specified and directed |
| 32 | S&F CP bib tap 15mm bore cast fency type chromium plated copper alloy with crutch butterfly handle, screwed down and screwed for iron pipe or for brass ferrule and fixed as specified and directed. |
| 33 | S&F 15mm bore CP Angle valve, brass chromium plated complete all as specified and directed. |
| 34 | S&F 15mm CP brass pillar tap with capastan head screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed for iron pipe complete all as specified and directed. |
| 35 | S&F Vitreous china wash hand basin pedestal pattern white including, waste coupling and waste pipe complete all as specified and directed. |
| 36 | S&Flooking mirror of size 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup screws complete all as specified and directed. |
| 37 | S&F CP soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 38 | S&F PVC connection 15 mm size with PTMT nuts of length 450mmcomplete all as specified and directed. |
| 39 | S&F PVC valveless flushing cistern 10 Ltr capacity (white), syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flushing pipe complete all as specified and directed. |
| 40 | S&F vitreous china wash down water closet pan (pedestal pattern), (excluding flushing cistern and flush pipe) including seat and cover and connection to drain or out going pipe and to flushing pipe, antisyphonage pipe etc complete all as specified and directed. |
| 41 | S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed |
| 42 | S&F PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed |
| 43 | S&F PVC (SWR) bends 110mm dia complete all as specified and directed |
| 44 | S&F PVC (SWR) Vent cowl for 75mm dia PVC pipe complete all as specified specified and directed. |
| 45 | S&F Rotational moulded polythene water storage tanks (Cylinderical vertical with closed top) hoisted and fixed in position 500ltrs, including ball PTMT valve 20 mm bore, high pressure with polythene ball & float complete all as specified and directed |
| 46 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed |
| 47 | S&F 125/110mm gully trap (SWR), setting and jointing with solvent cement complete all as specified and directed |
| 48 | S&F PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet rainforced with MS square tube complete all as specified and directed |
| 49 | S&F 30mm thick factory made solid panel PVC door shutter (style) consisting of frame made out of M.S tubes for tap & bottom rail MS frame shall be covered with head moulded plain colourscomplete all as specified and directed |
| 50 | M&L for PCC 1:2:4 type B-1 as in bed blocks, bed plates or similar works complete all as specified and directed |
| 51 | S&F butt hinges 100mm stainless steel complete all as specified and directed. |
| 52 | S&F aluminium anodised tower bolt, anodised length of bolt 150mm complete all as specified and directed. |
| 53 | S&F aluminium anodised handles 150mm size complete all as specified and directed. |
| 54 | S&F mild steel ventilator/ window with top hung shutter incl, MS peg stay complete all as specified and directed |
| 55 | M&L for prepration of new steel surfaces of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide zinc chorme primer complete all as specified and directed. |
| 56 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 57 | S&F 3mm thick sheet glass, ordinary quality glazing with oil putty or fixed with wooden beads in square n exc 0.50 sqm each pane complete all as specified and directed. |
| 58 | M&L for rendering 10mm thick on fair faces of brick work or concrete surface over roof in CM 1:4,mixed with liquidwater proofing compound @ 200ml per 50kg cement, surface finsihed even and smooth without using extra cement complete all as specified and directed.Note :- WPC shall be measured and paid separately. |
| 59 | M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning the surfacescomplete all as specified and directed . |
| 60 | M&L for APP based polymeric membrane minimum weighing 3.50kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified and directed |
| 61 | M&L for Applying two coat of bituminous aluminium paintcomplete all as specified and directed |
| 62 | M&L for construction of septic tanks for 25 users, foundation in PCC 1:2:4, brick work in cement mortar 1:4, RCCSlab covers includingRCC precastmanhole coverhaving 6mm plate embedded all around/fiber reinforced cover with angle iron frame Vent shaft and sludge chambers etc. including necessary earth work in any type of soil (soft/loose/hard/dense) all as shown on drg No TD-217 sheet No 17/ to 7/7 complete all as specified and directed. |
| 63 | M&L for construction of Soakage wells of size 1.2m dia & 4.5m depth ( effective depth 4.5 m ) in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solidin M-25 RCC including intercepting chamber, screen chamber Brick work in cement mortar 1:4, RCC cover slabinM-25/ RR masonry / Filling with brickbats,all as including necessary earth work in any type of soil (soft / loose / hard / dense)all asshown on drg No TD-309 Sheet Nos 1/4 to 4/4 complete all as specified and directed. |
| 64 | Excavation in trenches, not exceeding 1.5 Mts wide and not exceeding 10 Sqm on plan area and not exceeding 1.5 m deep in Soft/Loose soil complete all as specified and directed |
| 65 | M&L for Concrete bed to drain pipes of size 150mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete,Type C2, 1:3:6, complete all as specified and as directed. |
| 66 | M&L for 150mm dia salt-glazed stoneware drain pipes laid in trenches and jointed as specified complete all as specified and directed. |
| 67 | M&L for point wiringwith 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, sheathed, copper conductor cable in and including PVC concealed conduit of not less than 20mm dia complete with all accessories/fittings, brass screws, washer etc, including modular boxes, modular plates suitable for fixing modular switches/sockets and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, sheathed and connected to common earth and earth duly complete all as specified and directed for the followings :- |
| 68 | One tube light/Bulb/ ceiling fan/ exhaust fan/ security light point controlled by one, one way switch 05 / 06 Amps. |
| 69 | One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. |
| 70 | One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. |
| 71 | All as per described ser item no 69.00 here - in - before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board. |
| 72 | S&F Modular Switch, 1 module, 6A, AC, 240V, one way complete all as specified and directed |
| 73 | S&F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, complete all as specified and directed |
| 74 | S&F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, complete all as specified and directed |
| 75 | S&F Modular Switch, 1 module, 16A, AC, 240V, one way complete all as specified and directed |
| 76 | S&F ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified and directed |
| 77 | S&FLED tube light fitting T/5 surface mounting poly carbonate 240 volts 20 watts, 6500K complete all as specified & directed. |
| 78 | S&F lamp holder (Angular / Straight), insulated body, with back plate complete all as specified and directed |
| 79 | S&F LED lamp 2 pin 9/10 watt complete all as specified and directed |
| 80 | S&F LED light fitting mirror type with high output diffuser 2 feet,10 watt 220V, AC decorative type with driver holder and LED lamp including connecting up withthree core flexible copeer conductor cable of suitable size complete all as specified and directed |
| 81 | S&F Building security light fitting 1 x 35 LED type, drawn through and including GI bracket of size 25 mm dia bore light grade 1.4 mtr long, bend to shape including MS clamps made out of flat iron of size 32 x 4 mm - 02 Nos and necessary nuts, bolts, washer as required complete all as specified and directed. |
| 82 | S&F Exhaust fan PVC bodyAC single phase 230/240V size 250 mm sweep with blades, and louvers complete all as specified and directed |
| 83 | S&F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and IP - 43 ,IK08 protection with metal double door and flush to wall including all cutting / chases on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfacesand taking down the old distribution board of any type complete all as specified and directed |
| 84 | S&F MCB single pole 240 volt 6 to 32 amps 10 KA complete all as specified and directed |
| 85 | S&F in repairs MCB SPN 40 Amps, AC, 240V, 10KA, ISI Marked \"C\" curve incl thimble etc complete all as specified and directed. |
| 86 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed. |
| 87 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed |
| 88 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out including foming of bottom surface for laying of cable / pipe etc in soft/loose soil complete all as specified and directed |
| 89 | Supply and spreading clan fine dry river sand in trenches for cushioning of under ground cable/ cable duct complete all as specified and directed Note : Only punned thickness shall be measured for payment purpose complete all as specified and directed |
| 90 | M&L for fly ash brick protection length of brick shall be laid across the length of cable complete all as specified and directed |
| 91 | GI light grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified and directed |