| 1 | NOTES :-In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly. |
| 2 | S&F Aluminium composite panel as perspecifications for the interior finishing job. ACP of approved make(Alstrong , Aludecor, Eva bond or approved equivalent) of over all thickness is 4 mm with aluminium skin of 0.25mm on both sided,centre LDPE core material. Aluminium Composite Panels Composed of low density polyethylene sandwiched between Aluminium Sheets with frame Work fixed to the wall surface Cladding fixed to backup framework Aluminium Structure using Bolts (Self 6/50 & 6/ 19 Self Scrow all Panels will be fabricated into pestingbefore fixing ( Pasting Systems TYPE FIXING DETAIL) The complete material shall be confirming to ASTM standards for its various mechanical and physical properties.The panel shall be cut into match the grid size in required length and width as per the site condition,tampered & formed using router machine/curved using standard rolling machine, without leaving heavy marks on the sheet,so as to form a tray. The gap formed in between the panel shall be sealed with siliconsealant of AlstoneWS600 or equivalent after fixing the required masking tape and all other accessories.The sheet fixing and applying of sealant shall be in line and level to the building line. The panel colours will be as specified by Engineer-in-charge. |
| 3 | S&F Anodised aluminium frame work for wall panellingwith one or more rebates including joining cleat for fixing etc. complete all as specified |
| 4 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive offixing on to wall to make PVC Frame as per specification and drawing. |
| 5 | M&L Decorative laminate type 1 of surface finish of thicknes 0.90 mm, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"instructions |
| 6 | M&L Anti termit treatment Of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors |
| 7 | M&L antitermite treatmentAt points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed |
| 8 | Taking down cement plaster on brick or stone etc including racking out joints, hacking for key, scrubbing down with water etc complete all asspecified & directed. |
| 9 | M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 ,finished even and smooth without using extra cement |
| 10 | M&L for preparing new plastered surface of wall and applying 2mm thick putty finish to obtain smooth finish wall surface and applying two coat of Oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 11 | Dismantling of wall and ceiling boards (fiber, pulp , insulation etc)or insulation boards /slabs /blankets any thickness including cover fillets, grid work any description and any position all as directed. |
| 12 | S & FFalse Ceiling Frame Work using poweder coated Aluminiumsnap grid of size 605 x 605 mm size of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 605 x 605mm suspended with 6mm dia GI wire(of length n exc 1200 mm length) at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc fixed in ceiling with clips to aluminium snap gridforfixing 12mm thick gyprock false ceiling boards fixed to ceiling frame work all as specified.( ceiling board measured and paid seperately). |
| 13 | M&L for 12 mm thick gyprock false ceiling boards of size 600mmx600 mmfixed or laid/inserted to timber/GI/Aluminium frame work with screws including two coats of OBD over primer on ceiling surfaces |
| 14 | M&L French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler with two or more coats on old work |
| 15 | Taking down chowkats or frames exc 1.5 Sqm and not exceeding 4 Sqm (with shutters and grill (if fixed) without taking off shutters from the frame) |
| 16 | S&F Powder coating aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) |
| 17 | S&F Poweder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,handles 2 Nos in each door ,hinges ,anodised aluminium snap beading screws complete all as specified and as directed (minimum thickness of powder coating 50 micron) |
| 18 | S&F Sheet glass, 5.50 mm ordinary quality and glazing with oil putty in square in exc 0.5 sq.m in each pane |
| 19 | Supply and fixing for Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers |
| 20 | M&L Prelaminated particle board of 12 mm thickinterior grade, prelaminated both sides with decorative choice lamination &fixed with screws to timber framework |
| 21 | S&F Door closure hydraulically regulated designation No.3 universal type,suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixedcomplete all as specified and as directed. |
| 22 | Fixing only in repairs Powder coated aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified. |
| 23 | S&F Rolled mild steel inPlates (plain or chequered) channels,squarecutor notched(ordinaryand countersunk) forming holes,with riveted, bolted or welded attachment Fe-410W(GdeE-250)quality B |
| 24 | S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 |
| 25 | Preparation of new steel surfaces ofany discription, over 10 cm width and girth and applying twocoats of synthetic enamel paint over a coat of primer all as directed. |
| 26 | S&FEW-Type fire rated clear wiredglass(Integrity&Radiation) 7.20 mmthick of weighing 17 kg/Sqm ofof EI 60 specification of light tranmission 90%,Sound insulation 33 DB,with standing Temp range -20/+100 degree used in AL Partions/doorslike schott pyran glass,Vetroflam |
| 27 | M&L ACP board 5 mm thick fixed in Al partions with screws/necessary fittingsto Aluminium frame work all as specified and as directed |
| 28 | Taking down carefullycopper/ aluminium point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches with board, ceiling roses, pendents, bell, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface complete all as specified and as directed by the Engineer-in-charge. |
| 29 | Taking down unserviceable MCB DBs, Metal clad DBsalong with MCBs of any description and making good the disturbed surfaces of walls to match with existing sorrounding wall finish complete all as specified and as directed by the Engineer-in-charge. |
| 30 | Taking down unserviceable Security light of any description including service bracket, clamps nut bolts etc,. |
| 31 | Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable, with multi-stranded copper conductor cable, 1100 volts grade, drawn throughand including non metalic medium grade, rigid PVC conduit with all conduit accessories including concealing in any type of wall , provision of 1.5 sq mm PVC insulated copper cable FRLS as earth continuity conductor, company fabricated GI sheet steel terminal box suitable for Modular switches concealed flush to walls with front cover & base frame, screws, suitable for housing modular switches, socket outlets, fan regulators etc, all as specifiedand as directed for the following:- |
| 32 | (a) Onelight pointcontrolled by one one way switch . |
| 33 | (c) One ceiling fan point controlled by one one wayswitch. |
| 34 | (d) One Exhaust fan point controlled by one one wayswitch. |
| 35 | (e) One 3 pin socket outlet 5 Amps on the same board with other switches. |
| 36 | (f) One 3 pin socket outlet 5 Amps on the Independent board. |
| 37 | (g) One bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 38 | All as per item No. 30 here-in-before but with 4.0 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by the Engineer-in-charge. |
| 39 | M&L for Modular switch 6A, 1 way.Make :Anchor/ Havells/ Legrand/ Crabtree |
| 40 | M&L for Modular switch 16A, 1 way. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 41 | M&L for Socket outlet 6A modular. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 42 | M&L for Socket outlet 16A modular. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 43 | M&L for switch bell push modular. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 44 | M&L for Stepped type fan regulator(4steps), 120W, 2 modular. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 45 | S&F Electric bell/ buzzer 230 volts, single pole, 240 V. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 46 | S&F ceiling rose, 3 terminal, PVC/Polycarbonate isolated body. Make :Anchor/ Havells/ Legrand/ Crabtree |
| 47 | S & F in repairs, wall mounted 22W LED 6Klight fitting, 4\" ultra slim, with extruded Al , heat sink, integral driver, energy efficient, ready to use pack etc, complete with all accessories internally pre wired and fixing the same on and including two Nos, PVC Block and Connecting up with twin core twisted flexible copper conductor cable of suitable size up to ceiling rose including taking downold one, all as specified and directed by Engineer - in - Charge.Make: Havells, Model LUMILINEBS22WLED865SPCWH or equivelent in Philips/CG. |
| 48 | M&L for Taking down ceiling fan of any description, sealing cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, including reassembling blades andhanging ceiling fan and connecting up including provision of cable from ceiling rose to connector of fan all as specified and as directed. |
| 49 | Dismantle the unserviceable rubber bush with clamping set, supply and fixrubber bush with clamping set, GI bolt, nut and split pin complete all as specified and as directed by the Engineer-in-charge. |
| 50 | Sub main wiring complete with two runs of 6.0 Sqmm single core PVC insulated FRLS cable, 1100 volts grade, multi-stranded copper conductor cable with one run of 6.0 Sqmm single core, PVC insulated FRLS cable, 1100 volts grade, multi-stranded copper conductor cable as earth continuity conductor, drawn through and including suitable size of non-metallic rigid PVC conduit and conduit accessories concealed in any type of wall including stone masonry, floors / fixed to ceiling etc. all as specified and as directed. NOTE: Two runs of 6.0 sqmm cable conductor, one run of 6.0 sqmm earth continuity conductor cable and one run of PVC conduit shall be measured as one unit length. |
| 51 | All as per item No. 43 above but with 2x4.0 Sqmm + 1x4 Sqmm complete all as specified and as directed by Engineer-in-charge. NOTE: Two runs of 4.0 sqmm cable conductor, one run of 4.0 sqmm earth continuity conductor cable and one run of PVC conduit shall be measured as one unit length. |
| 52 | All as per item No. 43 above but with 2x1.5 Sqmm + 1x1.5 Sqmm complete all as specified and as directed by Engineer-in-charge. NOTE: Two runs of 1.5 sqmm cable conductor, one run of 1.5 sqmm earth continuity conductor cable and one run of PVC conduit shall be measured as one unit length. |
| 53 | All as per item No. 43 above but with 4x10.0 Sqmm + 2x10.0 Sqmm complete all as specified and as directed by Engineer-in-charge. NOTE: Four runs of 10.0 sqmm cable conductor, two runs of 10.0 sqmm earth continuity conductor cable and one run of PVC conduit shall be measured as one unit length. |
| 54 | S&F MCB distribution board sheet metal powder painted Single pole & Neutral enclosre with a two pin and earth plug and socket, one single pole MCB of 20 Amps complete all as specified and as directed by the Engineer-in-charge. Make-Havells/Legrand/Schneider |
| 55 | M & L for sheet metal enclosure for vertical distribution board when MCCB for in coming and MCBs for out going to be used VTPN 4 way , 415 volts double door complete including all as specified and as directed. Note :- MCCB and MCB will be measured and paid separately under relevant items. |
| 56 | M & L for sheet metal enclosure for vertical distribution board when MCCB for in coming and MCBs for out going to be used VTPN 8 way , 415 volts double door complete including all as specified and as directed. Note :- MCCB and MCB will be measured and paid separately under relevant items. |
| 57 | S&F MCB distribution board double door type, SPN 8 way sheet steel powder painted with bus bar neutral link earth bar etc. Make-Havells/Legrand/Schneider |
| 58 | S&F MCCB 3 pole, 415V, fixed type, 63 Amps with breaking capacity 16 KA complete all as specified and as directed by the Engineer-in-charge.Make-Havells/Legrand/Schneider |
| 59 | S&F MCB SPN 40 Amps, 240 voltssuitable for fixing in MCB DB \"C\" series complete all as specified and as directed by The Engineer-in-charge. Make-Havells/Legrand/Schneider |
| 60 | S&F MCB SP 5 to 32 Amps, 240 volts,suitable for fixing in MCB DB \"C\" series complete all as specified and as directed by The Engineer-in-charge. Make-Havells/Legrand/Schneider |
| 61 | Supply and fixingLED street light fitting 25/35 Watt 230 V AC outdoor type with high pressure diecast aluminium housing and heat resistent complete with driver, lampbracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make-Havells equivalent in Philips/CG |
| 62 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame Including louvers ,connecting wire and all accessories complete all as specified and as directed by the Engineer-in-Charge.Make-Havells or equivalent in Anchor/Usha. |
| 63 | Taking down the old unserviceable recess mounted fitting of any type, supply and fix, new ultra modern architectural 2\"x2\", recess mounted, 35/40W LED light fittingwhich provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling. including modification of the Existing false ceiling as required,complete all as specified and directed. Make :Havells/ Philips/Crompton/ Syska |
| 64 | Taking down the Air conditioner of capacity up to 2.0 TR with stabilizer carefully from the installed position, dismantling the complete unit(indoor and outdoor), cleaning the condenser coil for better efficiancy and re-assembling the complete unit and re-installing in its original position and testing on completion, complete all as specified and directed |
| 65 | Material & labour for filling up & charging of R-410a , R-22 and R-134a refrigerant to the cooling appliances as per site requirement, complete all as specified and directed. Note:-(i)Gas quantity shall be measured physically by weighing gas cylinder before and after filling. (ii) Suitable calibrated weighing machine for measuring gas quantity shall be provided by the Contractor. (iii) These items shall be operatedfor top up of ACs only. . |
| 66 | M&L for Earthing complete with galvanised cast iron steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the earth plate not less than 1.5mtr below normal ground level, connected to galvanised earth leadwire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel as earth electrod with top edge of earth plate not less than 1.5 mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI Light grade 15mm dia from earth plate to main switch board/panel,watring pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaining surplus excavated meterial all as required at site and specified in electrical plate No 5 of SSR part I 2009 complete all as specified and as directed. |