|
| 1 | FSD Ajmer |
| 2 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compoundlighting arrengements as per I.E.Rulesb) Electric Motors & Pumps for Water supply arrangement(Electrical points only)c) Air coolers Water cooler (Electrical points only)d) Water cooler (Electrical points only)e) Air conditioners (Electrical points only)f) Feeder pillars/LT/HT panels, MV/LT OH line maintenanceg) Transformer (only electrical works)h)Switching (on/off) operations of DG Set(One wireman and One Khallasi for all working days in a week) |
| 3 | FSD Kishangarh |
| 4 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compoundlighting arrengements as per I.E.Rulesb) Electric Motors & Pumps for Water supply arrangement (Electrical points only)c) Air coolers Water cooler (Electrical points only)d) Water cooler (Electrical points only)e) Air conditioners (Electrical points only)f) Feeder pillars/LT/HT panels, MV/LT OH line maintenanceg) Transformer (only electrical works)h)Switching (on/off) operations of DG Set(One wireman and One Khallasi for four days in a week) |
| 5 | FSD Nagaur |
| 6 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compoundlighting arrengements as per I.E.Rulesb) Electric Motors & Pumps for Water supply arrangement(Electrical points only)c) Air coolers Water cooler (Electrical points only)d) Water cooler (Electrical points only)e) Air conditioners (Electrical points only)f) Feeder pillars/LT/HT panels, MV/LT OH line maintenanceg) Transformer (only electrical works)h)Switching (on/off) operations of DG Set(One wireman and One Khallasi for four days in a week) |
| 7 | FSD Pali |
| 8 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compoundlighting arrengements as per I.E.Rulesb) Electric Motors & Pumps for Water supply arrangement(Electrical points only)c) Air coolers Water cooler (Electrical points only)d) Water cooler (Electrical points only)e) Air conditioners (Electrical points only)f) Feeder pillars/LT/HT panels, MV/LT OH line maintenanceg) Transformer (only electrical works)h)Switching (on/off) operations of DG Set(One wireman and One Khallasi for four days in a week) |
| 9 | FSD Bhilwara |
| 10 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compoundlighting arrengements as per I.E.Rulesb) Electric Motors & Pumps for Water supply arrangement(Electrical points only)c) Air coolers Water cooler (Electrical points only)d) Water cooler (Electrical points only)e) Air conditioners (Electrical points only)f) Feeder pillars/LT/HT panels, MV/LT OH line maintenanceg) Transformer (only electrical works)h)Switching (on/off) operations of DG Set(One wireman and One Khallasi for four days in a week) |
| 11 | FSD Marwar Junction |
| 12 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a) E.I., Lights/Fans/Plug points/ Powerpoints and Street/ Compoundlighting arrengements as per I.E.Rulesb) Electric Motors & Pumps for Water supply arrangement(Electrical points only)c) Air coolers Water cooler (Electrical points only)d) Water cooler (Electrical points only)e) Air conditioners (Electrical points only)f) Feeder pillars/LT/HT panels, MV/LT OH line maintenanceg) Transformer (only electrical works)h)Switching (on/off) operations of DG Set(One wireman and One Khallasi for two days in a week) |
| 13 | Material |
| 14 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(for Voltage grade 1100V as per IS:694) |
| 15 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 16 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(for Voltage grade 1100V as per IS:694) |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (for Voltage grade 1100V as per IS:694 and ISI Marked)Group \"C\" |
| 18 | Supplying 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.(Conforms to IEC 60947 Or IS/IEC 60898)(as and when required and directed by engineer in charge as per the site requirement) |
| 19 | Single pole (10A/20A) |
| 20 | Single pole and neutral(25A/32A) |
| 21 | Supplying and fixing following rating four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | 40 A |
| 23 | Supplyingfollowing size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement) |
| 24 | 3 Module (100mmX75mm) |
| 25 | 6 Module (200mmX75mm) |
| 26 | 8 Module (125mmX125mm) |
| 27 | 12 Module (200mmX150mm) |
| 28 | Supplying following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement) |
| 29 | 5/6 A switch |
| 30 | 15/16 A switch |
| 31 | 3 pin 5/6 A socket outlet |
| 32 | 6 pin 15/16 A socket outlet |
| 33 | Supplying two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement) |
| 34 | Supplyingfollowing way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 35 | 8 way SPN double door |
| 36 | Supplyingfollowing way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 37 | 4 way (4+12) way, TPN |
| 38 | Supplying 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(conforms toIS 8623, IEC 61439)(as and when required and directed by engineer in charge as per the site requirement) |
| 39 | Supply of 1200 mm sweep, ISI Marked induction motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 5.0, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374:2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Conforming TO BIS/IS Codes)(as and when required and directed by engineer in charge as per the site requirement) |
| 40 | LED Batten light (System lumen efficacy≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirementwith Driver efficiency >85%, Operating voltage AC140-270 Volt,frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI ≥ 80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), ofminimum 50000BurningHours with70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6500°K (AsperANSIBin),SDCM(Standard Deviation Colour Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete inallrespecti/c externalconnectionswith1.5 sq.mmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test report andalltestingrequired forLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). Powdercoateddiecast/Extruded aluminium Body (Thickness > 1.20 mm) |
| 41 | 18- 22 Watt |
| 42 | Supplying of Pressure Die Cast 70 watt LED well glass with high efficacy of greater than or equal to 100 lumens / watt fitting with control gear housing, SPD 5 KV/10KV,IP 66 Protection with secondaryoptics lenses and IK07/08 Protection with heat resistance glass eye bolt provided for mounting purpose & wire guard 70 Watt etc. as required of confirming to IS and IEC codes on the platform of godown truss/ truss of the clamps wiring with 3 x 1.5 Sq mm PVC insulated / WP flexible copper conductor wire, painting the clamps including connections and dismantling the existing fittings etc. as reqd.(as and when required and directed by engineer in charge as per the site requirement) |
| 43 | Supplying of Pressure Die Cast 40 watt LED well glass with high efficacy of greater than or equal to 100 lumens / watt fitting with control gear housing, SPD 5 KV/10KV,IP 66 Protection with secondaryoptics lenses and IK07/08 Protection with heat resistance glass eye bolt provided for mounting purpose & wire guard 40 Watt etc. as required of confirming to IS and IEC codes on the platform of godown truss/ truss of the clamps wiring with 3 x 1.5 Sq mm PVC insulated / WP flexible copper conductor wire, painting the clamps including connections and dismantling the existing fittings etc. as reqd.(as and when required and directed by engineer in charge as per the site requirement) |
| 44 | LED Streetlight fixture, powdercoatedpressure diecastaluminiumbody (System lumen efficacy ≥105 <120 lm/Watt) Supplying,installation,Testing&Commissioning ofStreetlightLEDfixture powdercoated pressurediecastaluminiumbody withdriver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5KVL,N,EasperIEC61000-4-5, Driverefficiency >85%,THD< 10%asperIEC 61000-3-2,P. F.≥0.95,IP-66,IK-10,CRI≥70, undervoltageandovervoltageprotection,EMI EMCAsper CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry)ofminimum 50000BurningHourswith 70%ofinitial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(Asper ANSIBin),SDCM (Standard Deviation Colour Matching) <5,Maximumpowerconsumption should not more than the specified rating and Fixture shall be of relevant BIS standardcomplete inallrespecti/cexternal connectionswith1.5 sq.mmFRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120lm/Watt output .LM79 & LM80 Test report andalltesting requiredforLED fixtures as per BISshall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkof aluminiumhousing such that LED junction temperature shall not rise above 90°C). |
| 45 | 45 Watt Street Light LED Fixture |
| 46 | LED FloodLight,powdercoatedpressuredie castaluminium (Systemlumenefficacy ≥105 <120 lm/Watt). Supplying,Installation,Testing&Commissioning ofFloodLight, powdercoatedpressuredie cast aluminiumbody withbuilt in or separate driver as per the requirement with Driver efficiency >85%, Input voltage:Input voltage:140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95,IP-66,IK-10,CRI ≥70,undervoltageandovervoltageprotection, EMI-EMCasper CISPR -15,lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <5, Maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be of relevant BIS standardcompleteinallrespecti/c external connectionswith1.5sqmm FRLS/HFFR,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report andalltestingrequiredforLED fixtures as per BISshall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermalmanagement: heatsinkofaluminiumhousing such that LED junction temperature shall not rise above 90°C). |
| 47 | 200 watt LED Flood Light |
| 48 | Supply of the following XLPEpower cable withPVC insulated and PVC Sheathed Armoured aluminiun conductor cableconfirming toIS -70981.1 KVgrade at site of work .(Conforming TO BIS/IS Codes) |
| 49 | 2 X 10 sqmm |
| 50 | 4 X 16 sqmm |
| 51 | 4 X 25 sqmm |
| 52 | Credit item |
| 53 | Dismantled scraped MS conduit pipe of different sizes, DB’s, GI wire and clamps |
| 54 | Dismantled scraped PVC conduit pipe of different sizes, and clamps |
| 55 | Dismantled Lights and Fittings ofall types |
| 56 | Dismantled Old copper wire |