| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 3 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level: |
| 5 | 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 6 | 1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 8 | Suspended floors, roofs, landings, balconies and access platform |
| 9 | Edges of slabs and breaks in floors and walls. |
| 10 | Above 20 cm wide |
| 11 | Reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete. Above Plinth level |
| 12 | Thermo-Mechanically Treated bars |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 15 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 16 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 17 | 20 mm nominal outer dia Pipes |
| 18 | Grassing with \" Doobs\" Grass (Grassing with \"Doobs\" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) |
| 19 | In rows 7.5 cm apart in either direction |
| 20 | Planting of flower |
| 21 | southern side of New OPD |
| 22 | Alternanthera Brasilliana |
| 23 | Marigold flower |
| 24 | Areca Palm |
| 25 | Gynae garden |
| 26 | Fox tail big |
| 27 | Marigold flower |