| 1 | Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed by Engr-in-Charge. |
| 2 | Removing of excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the ground. |
| 3 | M&L for hardcore of guage exc 63mm but not exc 100mm deposited spread and levelled in layers n.exc 15cm thick, watered and rolled/rammed to a true surface broken stone or boulders. |
| 4 | M&L 100m thick plain cement concrete Type D-2, 1:4:8 (using 40mm graded aggregate) as in sub-base of floors, path/hardstandings etc finished even and rough to receive topping layer complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for 50 mm thick sand filling under floors or in foundation including watering and consoildation for laying inter locking tiles all as specified and directed by Engr-in-Charge. |
| 6 | M&L for machine pressed precast coloured concrete interlocking paver blockof any shape and size approved by ETC, ISI marked (IS: 15658-2006) of 100mm thick, M-50 grade, in paths and hardstanding, with grey cement and pigment, laid tightly over and joints (Colour and pattern as approved by GE) complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregates as in coping of poles etc including weathring, slightly rounded or chambered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed by Engr-in-Charge. |
| 8 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil.complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for plain cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in foundation and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all asspecified and directed by Engr-in-Charge. |
| 11 | M&L 15mm thick rendering on wall in CM (1:4) of fair faces of brick work and finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for preparation of new/previously untreated plastered/concrete surfaces of wall and applying two coat of synthetic enamel paint over one of cement primer paint complete all as specified and directed by Engr-in-Charge. |
| 13 | Returning and filling under floor including spreading, levelling, watering and well ramming in layers not exc 25cm as in hard/dense soil complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply and fixing steel tubular swaged poles type 410 SP-31 (9 meter long) complete with CI base plate and final taper, plugs, bolts, nuts and screwscomplete all as specified and directed by Engr-in-Charge. |
| 15 | Supply and fixing LED street light fitting 70 watt 230V AC outdoor type with high pressure aluminium hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge. |
| 16 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium comductor, 1100 volts grade, cross sectional area 16 sqmm 4 core complete all as specified and directed by Engr-in-Charge. |
| 17 | Supply and fixing weather proof flate twin core PVC insulated & sheathed aluminium stranded conductor cables 1.5 sqmm drawn through street light pole duly making the hole upper and down both place and connection the street light to DB box complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply and fixing of bracket made out of 40mmx5mm angle iron 1.5 meter long and for fixing of street light including M&L for MS clamps, back plates fabricated from structural steel section 50x6mm, including nuts, bolts, washer, welding cold or hot, drilling of holes for bolts, in any shape of size including two coats of alluminium paint over a red oxide primer after prepration of steel surfaces for holding angle iron complete all as specified and directed by Engr-in-Charge. |
| 19 | Supply and fixing of loop In and loop out box pole mounted out door type hot press moulded SMC junction box of inside diemnsion not less than 300x300x150mm and outer dimension of 400x400x200mm with locking aggangement suitable for 240V, 50 Hz including MCB SP of 6Amp cap, fixing with 4 Nos of Aluminium busbar of 30 Amp rating for three phase with netural, painted with powder coating in siemens grey colour including clamp for fixing with steel pole complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply and fix Gl pipe 40 mm bore light grade for protection of cable including etc complete for fixing along pipe fixed along pole/laid under the road/laid under the floor complete all as specified and directred by Engr-in-Charge |
| 21 | Material and labour for Earthing complete with galvanised steel earth plate electrode600mmX 600mmX 6.3mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers of glavanized iron and steel earth wire protected by provision of GI medium grade pipe 15mm bore including provn of concrete pit made from PCC 1:2:4 type B-1 (using 20mm graded stone aggs) with 17mm thick cover of RCC (1:2:4) re-inforced with XPM (weight not less than 4 Kgs per sq mtr) and frame of angle iron 25x25x6mm with lugs to 02 Nos and with 6mm dia MS bar handle made to safe GI light grade 20mm bore pipe for watering perforated at bottom 1.75mtr long placed on top edge of earth plate, common salt and char coal filing, test point, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr all as per electrical plate No 3 of SSR 2010 Part-I connected to earth test point all as specified or indicated including testing on completion. Note:- (i) Item of earthing includs cost of 7.5 mtr long protection pipe of 15mm bore GI medium grade, any variation in lenght shall be adjusted through deviation order based on SSR rates enchanced by 20%.(ii) The required resistance of earthing shall be less than 3 Ohm, if not found to the required resistance, the contractor has to re-earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of resistance. |
| 22 | Supply, installation, commissioning and testing CPRI approved of single door outdoor type street light timer/control panel board 4 KW, 440 volt, AC 3 phase, 4 wire for outdoor installation \"KIOSK TYPE\" with sloping canopy fabricated out of steel sections i.e CRCA sheet 3.15mm thickness, angle/channel and flat iron sections of suitable size with opening on fron door fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty with door stoppers. The door opening shall not be less that 150 degree. The construction of panel board shall be dust, vermin proof, IP 65 standard with phosphatised powder coating painting externally and Internally to protect against corrosion. The panel shall be mounted on suitable size of channel section having ground clerance 60 cms from grouting bolts, complete fixing with danger notice board with necessary PCC work of 1:2:4 duly incorporated with following accessories:-(i)Main Incomer MCB 63A, FP 10 KA - 01 No(ii) Control MCB SP 5 Amps - 01 No(iii)Contractor 3P 63 Amp with Digital Time Switch for Auto On/Off - 1 Set(iv) LED indicator RYB- 1 Set(v) Selector Switch for bypass arrangement - 1 No |
| 23 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep for foundation of laying cable including getting out in soft/loose soil complete all as specified and as directed by Engineer-In-Charge. |
| 24 | M & L for sand cushioning in trenches including spreading and consolidation in layers of 8cm thick before laying the cable & 15 cm thick after laying the cable and punned down to form a bed complete all as specified and directed. |
| 25 | Supply and laying sub class \"B\" bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid complete all as specified and as directed by Engineer-In-Charge. |
| 26 | M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and as directed by Engineer-In-Charge (Volume of poles/struts embedded in concrete shall be deducted) |