| 1 | Supply and fix in repairWeather proof hose cabinet of size 750 x 600 x 250 mm fabricated from M.S. angle iron sections and 18 GMS sheet with full glass door and locking arrangement suitable to accommodate - 2Nos 15 M long hoses and 1 No branch pipe and nozzle including stand of exisitng height .The cabinet shall be painted with one coat of primer and two coats of primer and two or more coats of synthetic enamel paint or approved make and shade and shall be suitably mounted. |
| 2 | Supply and fix in repair SS 304 Short Branch Pipe 63 mm with necessary accessories conforming to IS : 903 ISI marked. (Make : Newage / Swati / Shah Bhogilal /. Arihant) |
| 3 | Supply andfix in repairs foam spray nozzle made of stainless steel(SS304) construction with 1/2 \" male BSP threaded inlet. The nozzle shall have K Factor of 30/45 and shall have aeratingarrangement to give foam of expansion 1:3 to 1:6 and suitable pattern for covarage of risk area . |
| 4 | Supply and fix in replacement of 12 Volts 7 Amps maintenance free dry cell battery, complete all as specified and as directed by Engineer-in-Charge. Make : EXIDE / AMCO / TATA GREEN. |
| 5 | Supply & fix in repair15 mm (½\") dia. NBCM Body chrome finishedside wall type sprinkler / Spray nozzal Medium Velocity having rating with deflector disc of conventional construction with all accessories require to install. Make: Kartar / Shah Bhogilal / HD / Newage |
| 6 | Supply & fix in repair ionization smoke detector from shed with base plate complete with base plate complete all as specified and directed byEngr-in-Charge. System Sensor / Honeywell / Fire Light / Notifier |
| 7 | Supply & fix in repair heat detector in shed with base plate complete with base plate complete all as specified and directed byEngr-in-Charge. System Sensor / Honeywell / Fire Light / Notifier |
| 8 | Supply & fix in repairBeam detector with Reflectors range 15 mtr x 15 mtr x 60 mtr Operating voltage 24 VDC with adjustable convex mirror(all required Accessories.) Make : System Sensor / Honeywell / Fire Light / Notifier |
| 9 | Supply and fix in repair of Hydrant Valve Oblique Type 63 mm complete made out of SS 304 fitted with PVC main blank cap and GI Chain IS 5290 with ISI mark incl Hydrant valve wheel cast iron type suitable for 63mm dia hydrant valve complete all as specified and directed.(Make : Newage/Kartar/Shah Bhogilal / Arihant) |
| 10 | Supply and fix in replace RRL hose pipe 63 mm dia& 15 meter long with male and female coupling with ISI mark all asspecified and directed by Engr-in-Charge |
| 11 | Supply and fix in repair Hydrant cap with chain for hydrant valve 63mm dia |
| 12 | Supply and fix Gun metal fire brigade inlet connection(suction collecting head) consisting of four nos 63mm dia instantaneous type male coupling with built in check valvesand 150mm dia flanged outlet complete with all accessories. |
| 13 | Supply and layin replacement of copper conductor armoured cable FRLSH of size3 corex 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed by Engineer-in-Charge. Make : POLYCAB/ PLAZA/ HAVELLS. |
| 14 | Taking down existing pipe of any type (CI, M/S, Niddhi pipe) &supply and laying MS Pipe \"C\" Classby of 200mm bore all as specified and directed by Engr-in-Charge.Make:-Prakash Surya,JindalNote :- Cutting of exisitng pipe, welding works and inserting any type of fittings for above bore pipe deemend to including in quoted rates |
| 15 | All as per item No 14 above…. But for 150 mm bore |
| 16 | All as per item No 14 above…. But for 100 mm bore |
| 17 | All as per item No 14 above…. But for 80 mm bore |
| 18 | All as per item No 14 above…. But for 50 mm bore |
| 19 | Taking down existing sluice valve and supply and fixe sluice valve PN 1.6 of 200mm bore all as specified and directed by Engr-in-ChargeNote :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to including inrates |
| 20 | All as per item No 19 above…. But for 150 mm bore |
| 21 | All as per item No 19 above…. But for 100 mm bore |
| 22 | All as per item No 19 above…. But for 80 mm bore |
| 23 | All as per item No 19 above…. But for 65 mm bore |
| 24 | Taking down existing foot valve and supply and fix CI foot valve of latest modelof 200mm bore all as specified and directed by Engr-in-Charge. Make:- NormexNote :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to including inrates |
| 25 | All as per item No 24 above…. But for 150 mm bore |
| 26 | All as per item No 24 above…. But for 100 mm bore |
| 27 | Material and labour for CI special/fittings suitable for CI flanged/socket ends pipe upto 200mm bore such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch \"Y\" junctin, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint etc complete including taking out old fittings complete all as specified and as directed. |
| 28 | M&L for MS Fabrication work,made out of structural steel sections as in frame work for cable & piping ducts/MS door panels etc at sewage installation ,MS angle /flats/plain sheet of appropriate gauge ,cut to size and made to the existing shape suitable for fixing MS chequred duct cover /door panel including nut and bolts and washers ,welding bracing work bending cold or hot drilling holes for bolts in any shapes or sizes as reqired including one coat of primer and two coat of synthetic enamel paint to the entire steel surface all as specified and directed. |
| 29 | Supply install, testing and commissioning indoor type fire fighting control panel for jockey pumpfactory fabricated made out of 2 mm thick CRCA sheetofsuitable size to accommodate all accessories / fittings, such as MCCBs,motor protection circuit breaker,Overload relay,Pressure switch etc,metering eqpt prewired with suitable size of copper conductor and duly powder coated and fixing mounting arrangement to wall duly maked the incomming & all outgoing controls and comprising with the following:- Incoming:MCCB TPN, 63 Amps 415 volts 36 KA - 01 No. (Thermal Setting adjustable type 70 - 100% (Ics-100% Icu)with connection terminals. Outgoing: (i) Power contactor up to 50 Amp,415 Volt,4 pole with 2 NO and 2 NCas per existing capacity of Jockey up to 15 HP-01 No(ii) Thermal Overload relay up to 50 Amp,415 Volt as per existing capacity of Jockey up to 15 HP-01 No(iii)connection for Pressure control switch having range2 bar to 14 bar ,IP 30 -01 No(iv)Auto manual selector switch -01 No (v) RYB indication LED type, 22.5mm dia, 230 volts protected with MCB SP 2 Amp showing 3 phase supply - 1 Sets (vi)Ammeter 0 to 500 Amp digital, 96x96mm, auxillary voltage 230 volts suitable size of CT with built in selector switch -1 No(vii) Digital Volt meter of range 0-500 Volts, 96x96mm, auxillary voltage 230 volts with built in selector switch -1 No (Viii)Internal wiring with single core copper conductor cable FRLS/ PVC Insulated Copper Strip of suitable size -1JobNote:(i) Connection of jockey pump to be done such that its autometically operated below 7 Kg/cm2.(ii)Pressure switch to be measured and paid separatly |
| 30 | Supply and fix pressure control swich having range 2 bar to 14 bar,IP 30 complete all as specifed and directed |
| 31 | Supply, Installation in repairsTesting & Commissioning of 8 Zone Microprocessor based conventional type Fire Alarm Panel incl following items(i) Panel indicator LCD.(ii) Fault Indicator(iii) Short Indicator(iv) Zone Isolate Indicator(v) System Ok Indicator(vi) Fire Indicator(vii) Supply Fault Indicator(viii) Panel fabricated of 16SWG CRCA Sheet Make : spencer / Honeywell / Fire Light / NotiFier |
| 32 | M&L for servicing of 20KLPD water softner quaterly (3 month basis) including replacement of water softner resin up to 25 ltr (for 3 month) ,cleaning/descaling of water softner weekly with non crushed type sea salt required up to 40Kgs per week or as per OEM recommendation for regeneration of water softner for OBRcomplete all as specified and directed. Note: (i) Rate of water softner Resin up to 25 ltr shall be included in quoted rate.(ii) Rate of non crushed sea salt up to 20 kg shall be included in quoted rate . |
| 33 | Supply and fix Addressable fire panel control panel having blue liquid crystal display with backlight illumination ,control keys having Exacute,Silence/Resound,mute,Buzzer,Extend delay,System Reset,Show Alarm zone,Programming keys having independent programmable function keys and LEDs indicators which show various indication such as fire fault ,Disablement,Test Buzzer muted,Delay mode ,Sounders,Disables and power also dedicated fault LEDs for system fault,Addressable fire panel having Electrical operating range110/230VAC +/-15% with PUC Rating 24 V DC 4 A including 2X17 AH standby battery complete all as specified and directedMAke Honeywell model No:DXC2 |
| 34 | M&L for reparingof MS flanged pipe linehaving 150 mm to 200 mm dia bore including ,de-watering trenches of leakage pipe line ,making new weld joint as required at site,replacing old Wurn outnut and bolt incl existing size of gasket ,testing complete all as specified and directed Note: (i) Total excavation and earth work as required at site to carryout the repair work is deemed to be included in quoted rates.(ii) DG set required for welding shall be provided by the contractor and rates to be included in the quoteted rates. (iii) the contractor shall arrange pump set for de-watering of leakage and rate for this are deemed to be included in unit rate quotated by the the contractor. |
| 35 | M&L for repair hydrant boxe installed at Various location in Depot area including replacement of unserviceable/Broken part such as glasses of existing shape and size,rubber gaskit,Painting as per existing couler complete all as specified and directed |
| 36 | Material and labour for PCC 1:3:6 type C 1 (using 20 mm graded stone aggregate) for making pump , motor,hydrant foundation orany size as specified including necessary form work if any for fixing GI pipe/air termination rod complete all as specified and asdirected. |
| 37 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 metre depth for foundation, laying of cables/pipes/poles etc., and getting out in soft/loose soil complete all as specified and directed. |
| 38 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed. |
| 39 | Removing excavated material/soil to a distance not exceeding 50mand depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
| 40 | Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz doublepole 100 Amp all as specified and directed by EIC. |