| 1 | Taking down the Carefully unserviceable any type security lights /Hanger light/wall lights of any capaciy/size from pole/ bldgs/ walls lightand refixing after repair unsv items such as choke/lamps/ignitors/ Surge protection, drivers complete all, as specified and directed by Engineer in Charge.(Note:- (i) After completion of contract, contractor shall hand over all the security/perimeter lights conventional type\" in perfect running/functioning condition to the department.(ii)Contractor shall provide his authorised Cell/mobile No.and local address to contact and communicate the message for any break down and contractor\"s rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to daycomplaints of any nature/type. (iii) Penalty for not rectifying the defect in time(within 72 hrs)will be charged to contractor and the amount of penalty @ Rs 500/- per complaint will deducted from the due payment of contract.(iv) Complaints will be treated as rectified only after user\"s \"Satisfactory slip \"will be produced by contractor to concerned JE E/M.(iv) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made.(v) Old material obtained from spares replacedunder this item shall be contractor\"s property and will be measured as per credit schedule.(vi) Cost of minor spares i.e, wirnig inside light fittng, connecting wire upto terminal box, nut bolts washers or accessories as required for fixing light on pole, connector blocks are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately under respective item of work,(vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates(viii) Area cleaning if required within vicininty of lighing poles is to be done by contractor only and rate for area cleaning is deemed to be included in quoted rates . (X) Contractor will be take proper shutdown before repaire with communation of IPSS team / Security section for repair of perimeter lights complete all as specified and directed by Engineer-in-Charge.Note:-Items 2 to 13 supply only and fixing against Item 1 |
| 2 | Supply for repair/replacement of LED outdoor driver for 45/60 W LED light complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply for repair/replacement ofLED outdoor driver for 70 to 75 W LED light complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply for repair/replacement of driver for 90 W LED flood/ street light complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply for repair/replacement ofLED outdoor driver for 120 to150 W LED flood light complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply for repair/replacement of voltage surge protection device for LED lights of wattage upto 75 W complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply for repair/replacement of voltage surge protection device for LED lights of wattage 75W to 150 W complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply for repair/replacement of street lights cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required, drawn into existing conduit/GI pipe of wall or pole complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply for repair/replacement ofmultifunctional digital Astro Rex3 D-21 including connecting electrically using copper conductor cable of appropriate size complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply for repair/replacement ofair break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 50 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply for repair/replacement ofair break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 70 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply for repair/replacement ofair break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 100 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply for repair/replacement ofAC coilsuitable for Power contactor50 to 100 Amp exciting voltage 240/415 Volt complete all as specified and directed by Engineer-in-Charge. |
| 14 | S&F in replacement offlame proof flood LED light fitting 80 watts FLP with necessary braket, clamps duly painted with two coats of aluminium paint over a coat of red oxide primer, including bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. |
| 15 | S&F in replacement offlame proof flood LED light fitting 100 watts FLP with necessary braket, clamps duly painted with two coats of aluminium paint over a coat of red oxide primer, including bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. |
| 16 | S&F in replacement offlame proof flood LED light fitting 120 watts FLP with necessary braket, clamps duly painted with two coats of aluminium paint over a coat of red oxide primer, including bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. |
| 17 | S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 35 to 40Watt high power LED withSMD LED aray with efficiency above 100 lm/W with inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. |
| 18 | S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 60Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. |
| 19 | S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 72 Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F in repair pressure die-cast aluminiumIP 65 cool white road way luminaire with high power LED as Light source with 90 Watt high power LEDwith inbuilt surge protection upto 5 kv including with suitable GI Pipe Bracket , double clamps complete with nut boltswith pole and 2.5 sqmm 3 core copper wire multistrandfor connection from DB to Light complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F in replacement of 2 runs of 1.5 Sqmm PVC insulated stranded copper cable including PVC cassing/capping, ceiling rose, switches mounted on PVC boxes andPVC conduit 20 mm external dia medium grade saddling on building with proper clamping all fixing arrangements etc complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F in replacment of 40 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge. |
| 23 | S&F in replacement of 32 mm dia light grade GI pipe bracket 1.2 mtr long bend to shape including clamps made out of 50 x 6 mm flat iron duly painted with two coats of aluminium paint over a coat of red oxide primer, suitable size nuts, bolts and washers etc. complete all as specified and directed by Engineer-in-Charge. |
| 24 | Cutting the tree branches/ stem all around the over head line to mainten clear distance 2 mtr all around the conductor of any size or girth and shifting it to nearest waste depot and cleaning area complete between the span of two poles length of not exc 50 mtrs complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and laying GI tubing light grade galvanised of bore 50 mm bore laid in trenches or fixed on pole/ wall for protection of UG cable complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and laying GI tubing light grade galvanised of bore 40 mm bore laid in trenches or fixed on pole/ wall for protection of UG cable complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply, install, connect & testing cubical outdoor type factory made double door, powder coated LT bus bar feeder pillar box for 200 amps 3ph and neutral arrangement of size 500mmx500mmx200mm with MCB 4 pole 63 to 100 A complete weather proof and verminproof conforming to IP-54 made out of 3.15 mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS.It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping complete all as specified and directed by Engineer-in-Charge. |
| 28 | Scraping of old paint from the street light steel tubular pole with out removing accessories and preparationof surfaces for repainting . Repainting the pole with one coat of alternative yellow and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint . Repainting the remaining pole and clamps GI braket etc above 1.5 mtr height by applying one coat of alumn paint complete all as specified and directed by Engineer-in-Charge. |
| 29 | Painting of street light PCC pole without removing accessories with one coat ofalternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.eclamps GI bracket etc by applying one coat of aluminum paintcomplete all as specified and directed by Engineer-in-Charge. |
| 30 | Writing No of pole with letters/ figures of size not exc 30 mm with black painton a yellow circle of dia 75 mm all as required complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F PVC medium grade 20 mm conduit including complete fitting and fixture i.e. bend, elbow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F steel 20 mm conduit including complete fitting and fixture i.e. bend, elebow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge. |
| 33 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in benching including whethering slightly chamfered angles and finished exposed surfaces even and smooth including necessary form work for concrete eathing pit complete all as specified and directed by Engineer-in-Charge. |
| 34 | Excavation in trenches in any type of soil not exc 1.5 Mtr in width and not exc 1.5Mtr in depth and getting outfor laying of cable complete all as specified and directed by Engineer-in-Charge. |
| 35 | Returning filling in, including spreading leveling,watering and well ramming in layers not exc 1.5cm each layer complete all as specified and directed by Engineer-in-Charge. |
| 36 | Removal of surplus soil to distance not exc 50mtr and depositing where directed at level not exc1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 37 | M&Lfor sand cushioning to underground cable 8cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and directed by Engineer-in-Charge. |
| 38 | Reuse old Sub Class\"B\"brickcovering protectionto the eletric cablelaiddry flat transversallyalongthe lengthof cableon sandcushioningwith widthequal to lengthof brick complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for sub class “B” bricks laid dry flat cover the cablewith width equal to the length of cable, abutting each other for protection of cable complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 80 to 90 Watt high power LED as light source SMD LEDwith inbuilt surge protection upto 5 KVincludingcomplete with nut boltswith pole and connection wire complete all as specified and directed by Engineer-in-Charge. |
| 41 | S&F in repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 120 Watt high power LED as light source SMD LEDwith inbuilt surge protection upto 5 KVincluding with Bracket, double clamps complete with nut boltswith pole and connection wire complete all as specified and directed by Engineer-in-Charge. |
| 42 | Taking down old unserviceable LT cable any size up to185sqmm 2/3.5/4 core retrieved complete all as specified and directed by Engineer-in-Charge. |
| 43 | Relayingonly LT cable taking out aganist item passing through pipe 1100 volts grade heavey dutycable with PVCinsulated multistand alumn conductor of size6 to 185 Sqmm 2/3.5core, armoured with galvanized steel strip or wire complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sq mm, 2 core including cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 16 sq mm, 2 coreincluding cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 10 sq mm, 2 coreincluding cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 6 sq mm, 2 coreincluding cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 50 sq mm, 3.5 coreincluding cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 70 sq mm, 3.5 core including cable lugs, jointing materials ,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 95 sq mm, 3.5 coreincluding cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 120 sq mm, 3.5 coreincluding cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 185 sq mm, 3.5 coreincluding cable lugs, jointing materials, GI pipeetc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply/ Installing testing & commissioning of street Light Pole Box of 63 Amp single phase Two wire having two no Aluminium Bus Bar including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall using MS strip of size 20x3mm and nuts & bolts of required size complete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 16 Sqmmserved with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circularincluding cable lugs, jointing materials ,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 10 Sqmmserved with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circularincluding cable lugs, jointing materials, GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 56 | S&F LT cable jointing kit for 1100 V grade cable forend boxheatshrink type joint complete with jointing material and accessories suitable for XLPE armoured Aluminium conductor cable of size 10-35Sq mm 2/3.5/4 core complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F LT cable jointing kit for 1100 V grade cable forstraight through cable heatshrink type joint complete with jointing material and accessories suitable for XLPE armoured Aluminium conductor cable of size 10-35Sq mm 2/3.5/4 core complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F LT cable jointing kit for 1100 V grade cable forend joint indoor/outdoorheatshrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 95-240Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F in replacement MCB single pole 240 volts any rating from 5 to 30 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix in replacement MCB single pole neutral 240 volts any rating 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F MCCB 4 pole 415 volts with rupturing cap 16 KA , 100 Amps thermal magnetic release complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F MCCB 3 pole 415 volts with rupturing cap 16 KA 63 Amps thermal magnetic release complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&Fin repair pressure die-cast aluminium IP 65 cool white flood Light luminaire with 150 Watt high power LED as light sourcewith inbuilt surge protection upto 5 KV including with bracket , double clamps complete with nut boltswith pole and connection wire complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supplying, installing and commissioning ofLT feeder box, outdoor type of size 0.90mx0.60m x 0.50m, made out of MS sheet 3.15mm thick,legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCB SPN 63 Amps, 230 volts -04 No\"s, complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supplying, installing and commissioning ofLT feeder box, outdoor type of size 0.90m x 0.60m x 0.50m, made out of MS sheet 3.15mm thick,legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCCB 4 pole, 160 Amp, 415 volt, microprocessor release with rupturing capacity 36 KA, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply, installation and erection in true vertical position or to be planted as strut steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing conforming to IS-1161 part-II, type 410 SP -31 (9.0m long) including drilling of holes of required size and Nos for fixing of cross arms/clamps,poles shall be painted internally throughout using anti corrosive black bituminous paint conforming to IS: 158-1968 and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surfaceand two coats ofblack bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge. |