| 1 | M&L for strip opening of unserviceable/burnt ceiling fan any make and any sweep dismantling/taking down from its position for overhauling including cleaning, greasing, oiling and minor repair work replace capacitor, including checking nuts and bolts, clamps, fan regulator, fan rod etc complete all as specified and directed.(Note:1. Capacitor,Bearing, Regulators, Rubber bush reel, fan rod and other connected items shall be measered and paid separately under respective items as supply only. 2 Contractor shall employe two nos electrician attending complaint on all working days for camp area 4area and 5 Area each, 3. Complaint slip will submit at 1700 Hrs daily in complaint office. 4. Dismatling /Fixing of repaired fan in any location of camp area, 4 area and 5area shall be contractors responsibility at his own arrangement of transport and T&P. 5. Old burnt wire will be contractors property and necessary credit shall be recovered as per sch of credit attached. 6. rewinding/Overhauling shall be measered & paid seperately under respective items of Sch.) |
| 2 | Description all as per Item No 2 here-in-before but for exhaust fan size 300 to 450 mm sweep complete all as specified and directed. |
| 3 | Description all as per Item No 2 here-in-before but for wall mounted fan/cabin fan/pedastal fan of size up to 450 mm sweep complete all as specified and directed. |
| 4 | M&L for rewinding of ceiling fan motor 1200/1400 mm sweep any make with super enameled copper winding wire ISI marked ofgauge as per existingincluding cutting and getting out old US winding, sleeve work, varnishing , threadingincl. making connections with three core copper flexible wire of suitable sizeand reassembling the same and two coats of synthetic enamel paints with spray painting and writing MES number ind. cleaning the fan with cleaning materials or thimmbles after testing atfull load with blades to the entire satisfaction of Engineer incharge complete all as specified and directed. Note: Rewinding work of ceiling fan/ exhaust fan/ cabin/wall mounted fan shall be carried out inside the office complex location as directed by the Engr in Charge. |
| 5 | Description all as per Item No 4 here-in-before but exhaust fan of size 300 mm sweep, 230 V, AC complete all as specified and directed. |
| 6 | Description all as per Item No 4 here-in-before but exhaust fan of sizeup to 450 mm sweep, 230 V, AC complete all as specified and directed. |
| 7 | Description all as per Item No 4 here-in-before but for wall mounted/cabin fan of size up to 450 mm sweep complete all as specified and directed. |
| 8 | M&L for machining the shaft of ceiling fan to suit the gun metal bushes off sizes complete all as specified and directed. |
| 9 | S&F in repair Ball bearing of ceiling fan of size 6201/6202 complete all as specified and directed. |
| 10 | S&F in repair Ball bearing of exhaust fans of size 6203/6204 complete all as specified and directed. |
| 11 | S&F in repair Gun metal bushes for exhaust fans of suitable sizes complete all as specified and directed. |
| 12 | S&F in repair capacitor 2.5 MFD, 230V, AC complete all as specified and directed. |
| 13 | S&F in repair capacitor 3.15 MFD, 230V, AC complete all as specified and directed. |
| 14 | S&F in repair capacitor 4 MFD, 230V, AC complete all as specified and directed. |
| 15 | S&F in repair shackle rubber bush/rubber reel of suitable sizes for ceiling fan 1200 / 1400 mm sweep complete all as specified and directed. |
| 16 | S&F in repair flexible wire 23/0.0076 size three core, 1100 V, twisted, PVC insulated, copper conductor multistrand for connection complete all as specified and directed. |
| 17 | S&F in repair MS nut & bolt with cut washers 8 mm dia and safety pin of suitable length for hanging of the ceiling fans complete all as specified and directed. |
| 18 | S&F in repair MS clamp including rubber washer, nut, bolt, washer and safety pin for hanging the ceiling fans of suitable size complete all as specified and directed. |
| 19 | S&F in repair Down rod MS 15mm dia, heavy duty of size 300 mm long including making hole for hanging ceiling fan complete all as specified and directed. |
| 20 | S&F in repair Down rod MS 15mm dia, heavy duty of size 450 mm long including making hole for hanging ceiling fan complete all as specified and directed. |
| 21 | S&F in repair ceiling fan regulator electronic switch type 5 stage speed variation ISI marked complete all as specifiedanddirected. |
| 22 | S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specifiedanddirected. |
| 23 | M&L for preparing the surface of ceiling fan, exhaust fan, pedestal fan including cleaning, removing grease, carbon dust and painting with one coat of synthetic enamel paint of approved colour with spray painting and writing MES number complete all as specified and directed. |
| 24 | S&F in replacement15mm bore, GI pipe,\"medium grade; for making down rod of size for hanging ceiling fan including MS clamps of suitable sizeand shape complete all as specified and directed.Make: Tata/Jindal. |
| 25 | S&F inreplacementmild steel louvers/shutters suitable for 300 mm sweep exhaust fan including fixing arrangementcomplete all as specified and directed. |
| 26 | S&F inreplacementmild steel louvers/shutters suitable for 450 mm sweep exhaust fan including fixing arrangement with nuts,bolts and pvc sheet for suitable size of hole complete all as specified and directed. |
| 27 | S&F in replacementPCB Card suitable for existing BLDC ceiling fan 1200mm for existing make , 230V, AC, 26/28 wattscomplete all as specified and directed.Make- Halonix/ Bajaj/Crompton |
| 28 | S&F in replacementmotorsuitable for 250mm PVC exhaust fan for existing make & model , 230V, AC complete all as specified and directed.Make- Havells/ Bajaj/Crompton |
| 29 | S&F inreplacement PVC clamp for capacitor for fans of suitable sizes complete all as specified and directed. |
| 30 | Supply and fixing exhaust fan 300 mm sweep steel body, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed. |
| 31 | Supply and fixing exhaust fan 250 mm sweep PVCbody, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed. |
| 32 | S&F in replacementof 5 Star BLDC Ceiling fan 1200mm sweep suitable to work on single phase AC 230volts 50 Hz complete with connecting electrically to ceiling rose or connector black using PVC insulated and over all sheated 3 core cable of size 0.75Sqmm with flexible copper conductor all as required and direcetd.(Note: Old Ceiling fan and blades are deposit to MES store yard) Make:Havells/Crompton/bajaj |
| 33 | S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 34 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 35 | M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia \"medium grade\" PVC concealed conduits ISI marked and fittings, including anodised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.Note:- Screw used for fixing TW baords, casing and caping ceiling rose, square blocks etc should be nickel cadmium screws.One light/fan point controlled by one 5 Amps one way switch |