| 1 | Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules.a)E.I., Lights/Fans/Plug points/ PowerPoint’s and Street/ Compound lighting arrangements /MCB/MCCB etc.b) Water supply arrangementc) Water coolerd) Air coolersf) Feeder pillars/LT panels maintenanceg) MV/LT OH line maintenance h) Operation of the installed DG Sets, Checking/Refilling of Fuel, Urea etc. (to be provided by Department)i) High mast lighting systemj)Transformer (Preventive Maintenance)k) Maintenance of all other equipment’s as specified in Electrical SOP and any other electrical works directed by JE(EM)/Manager(EM)/ Incharge of Depot (Note: (i)Rates are exclusive of EPF and ESI, which shall be desposited by the contractor as per latest applicable rules. The same shall be reimbursable to the contractor upon submission of relevant supporting documents.(ii) Wages paid shall not be less than Minimum Wage fixed by Central labour commission as amended from time to time.) |
| 2 | BG Sirsa+ FSD Sirsa(2 wireman + 1 Khallasi for All workingdays ) |
| 3 | FSD Hisar + DO Hisar( 1 wireman + 1 Khallasi for All working days ) |
| 4 | FSD Dabwali ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 5 | FSD Kalanwali ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 6 | FSD Fatehabad ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 7 | FSD Bhattu ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 8 | FSD Ellenabad ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 9 | FSD Bhiwani ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 10 | FSD Barwala ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 11 | FSD Tohana ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 12 | FSD Bawani Khera ( 1 wireman + 1 Khallasi for 3 days a week ) |
| 13 | Supplying of following sizes of steel conduit along with following accessories (As Per DSR 2022): 1) 25 mm inspection/solid bends : 4 Nos. per 50 metre2) 25 mm sockets : 15 Nos per 50 metre3) 25 mm iron staples/saddles/screws : 85 Nos. per 50 metre 4) PVC fastener 40mm long: 85 Nos. per 50 metre |
| 14 | 25 mm |
| 15 | Supply of FRLS PVC Insulated copper conductor single core cable of following sizes (with necessary color coding for phase, neutral and earth wire) |
| 16 | 1.5 sqmm |
| 17 | 2.5 sqmm |
| 18 | 6 sqmm |
| 19 | Supplying of 20 mm Dia size of PVC conduit along with following accessories : 1) 20 mm PVC Bends : 4 Nos. per 50 metre2) 20 mm PVC Couplers : 15 Nos per 50 metre 3) 20 mm iron staples/saddles/screws : 85 Nos. per 50 metre 4) PVC fastener 40mm long: 85 Nos. per 50 metre |
| 20 | Supplying of 25 mm Dia size of PVC conduit along with following accessories : 1) 25 mm PVC Bends : 4 Nos. per 50 metre2) 25 mm PVC Couplers : 15 Nos per 50 metre3) 25 mm iron staples/saddles/screws : 85 Nos. per 50 metre 4) PVC fastener 40mm long: 85 Nos. per 50 metre |
| 21 | Supplying of 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles. |
| 22 | Single Pole |
| 23 | Doble Pole |
| 24 | Supplying following rating, TPN, 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles (Conforms to IS/IEC 60898 or IEC 60947 - 2 )(Confirming to relevant BIS Standards/Codes) |
| 25 | 63 A |
| 26 | Supplying of 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA .(As per std . Specification IS:12640 & as per scope of work) |
| 27 | Supplying following piano type switch / socket (ISI marked) |
| 28 | 5/6 amps switch |
| 29 | Rewinding & repairing of ceiling fan upto 48\" and above. |
| 30 | LED Batten light (System lumen efficacy ≥120 <135lm/Watt)Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 31 | Supply of LED driver with the same driving power & current, suitable for an existing 60 W street light/ 60 W Flood light fitting. |
| 32 | Supply of LED driver with the same driving power & current, suitable for an existing 70-watt well glass fitting. |
| 33 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 72 Watts |
| 34 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, rating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 70 Watts |
| 35 | Supplying of XLPE insulated and PVC tape innersheated aluminiumaluminium conductor armoured cable of 1.1 KV grade of following sizes confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.(Confirming to relevant BIS Standards/Codes) |
| 36 | CABLE SIZE 2 X 10 SQ.MM |
| 37 | CABLE SIZE 4 X 16 SQ.MM |
| 38 | CABLE SIZE 4 X 25 SQ.MM |
| 39 | Supply of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders |
| 40 | 100 A ,30 KA FPMCCB |
| 41 | Supply of 200 Amp Kit Kat fuse of make with ISI mark for main board in switch room. |
| 42 | Supply of 500 Amp Kit Kat fuseof make with ISI mark for main board in switch room. |
| 43 | Rewinding of submersible pump set motor at workshop (upto 5HP capacity) |
| 44 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE powercable of 1.1 KV grade of following size on wall surface as required. |
| 45 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 46 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. |
| 47 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 48 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 49 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and<135 lm/Watt).Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be ofrelevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junctiontemperature shall not rise above 90°C).8.16.1 50 watt |