| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 4 | Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level withCement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand |
| 8 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Half Brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | Extra for providing and placing in position 02 nos 6mm dia m.s bars at every third course of half brick masonry (with F.P.S bricks) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) |
| 13 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement: 3 fine sand). |
| 14 | Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete. |
| 15 | Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. |
| 16 | Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 17 | Centring and shuttering including strutting,ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Hot rolled twisted bars |
| 19 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 20 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and nuts as required including fixing of necessary butt hinges and screws and applyinFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 21 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes. |
| 22 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 23 | 12 mm cement plaster of mix1:6 (1 cement : 6 fine sand |
| 24 | 15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand) |
| 25 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 27 | Providing and fixing ISI marked oxidised M.S.sliding door bolts250x16mm |
| 28 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm |
| 29 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm |
| 30 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 31 | Brick edging 7cm wide 11.4 cm deep to plinth protection with commonburnt clay F.P.S. (non modular) bricks of class designation 7.5 includinggrouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 32 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 33 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS :15622 (thickness to be specified by the manufacturer) of approvedmake in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall |
| 35 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm |
| 36 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 37 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 38 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 39 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 40 | Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 41 | Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work. |
| 42 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 43 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 44 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall15 mm dia. nominal bore |
| 45 | Providing and fixing brass stop cock of approved quality15 mm nominal bore |
| 46 | Providing and fixing ball valve (brass) of approved quality completeHigh or low pressure with plastic floats15 mm nominal bore |
| 47 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 48 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms15mm nominal bore.. |
| 49 | roviding and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing Compound, laid over a bed of 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) and finished neat complete. : |
| 50 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes75 mm diameter |
| 51 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes110 mm diameter |
| 52 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories coupler 75mm diameter |
| 53 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories coupler110mm diameter |
| 54 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories single tee 110x110x110mm diameter |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 75mm diameter |
| 56 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 110mm diameter |
| 57 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 |
| 58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 59 | Providing&laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface prepration, first layer of slurry of cement@ o.488kg/sqm mixed with waterproofing compound &.0.253kg/sqm (b) laying second layer of fiber glass cloth when the first layer is still green. overlaps of joints of fiber glass cloth should not be less than 10 cm.(c)third layer of 1.5mm thickness consisting of slurru of [email protected]/sqm mixed with waterproofing [email protected]/sqm and course [email protected]/sqm thish will be allowed to air cure for 4 huors followed by wter curring for 48 hours. the entire treatment will be taken up to 30cm on parapit wall and tucked into groove in parapit all around(d) fourth &final layer of brick tiling with cement morter (which will be paid seprately .for purpose of measurement the entire treated surface will be measured. |
| 60 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick. |
| 61 | Excavation in foundation for retaining & breast walls in all types of soils and rocks including lead, lift and disposal of surplus material as per direction of engineer - in - charge |
| 62 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWD Uttarakhand specifications) |
| 63 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand pecifications) Please Enable Macros to View BoQ information |