| 1 | Annual maintenance of 10 Passengers (G+5) lift with OEM (Johnson) installed at SRE building at Air Force Station Gorakhpur by providing routine and preventive maintenance/services and attending breakdown calls for 12 months complete all as specified and as directed.NOTE:- (i). Consumable items and defective spare parts will be measured and paid separately under respective item.(ii) The contractor shall submit a MOU with OEM to GE before commencement of work.(iii) Routine visit shall be as per OEM recommendation and as decided by GE. |
| 2 | Annual maintenance of8 Passengers (G+2) lift with OEM (Johnson) installed atMPR (274 SU) at Air Force Station Gorakhpur by providing routine and preventive maintenance/services and attending breakdown calls for 12 months complete all as specified and as directed.NOTE:- (i). Consumable items and defective spare parts will be measured and paid separately under respective item.(ii) The contractor shall submit a MOU with OEM to GE before commencement of work.(iii) Routine visit shall be as per OEM recommendation and as decided by GE. |
| 3 | Annual maintenance of 8 Passengers (G+4) lift with OEM(OTIS) installed atDWR at Air Force Station Gorakhpur by providing routine and preventive maintenance/services and attending breakdown calls for 12 months complete all as specified and as directed.NOTE:- (i). Consumable items and defective spare parts will be measured and paid separately under respective item.(ii) The contractor shall submit a MOU with OEM to GE before commencement of work.(iii) Routine visit shall be as per OEM recommendation and as decided by GE. |
| 4 | S&F in replacement of ARD battery of capacity 12 Volt 18 AH complete all as specified and as directed. |
| 5 | S&F in replacement ofbattery charger of capacity 12 Volt 2.5 AH complete all as specified and as directed. |
| 6 | S&F in replacement of ARD battery of capacity 12 Volt 7/7.2 AH complete all as specified and as directed. |
| 7 | S&F in replacement of metallic body exhaust fan 300 mm sweep, 230 Volt, AC for fixing in machine room for proper ventilation including necessary electrical connections complete all as specified and as directed.Make :- Havells Cat part No Ventil Air DS/Crompton Greaves/Bajaj as approved |
| 8 | S&F in replacement of power door contact female complete all as specified and as directed. |
| 9 | S&F in replacement of metal roller \"V\" assembly complete all as specified and as directed. |
| 10 | S&F in replacement of nylon roller \"U\" assembly complete all as specified and as directed. |
| 11 | S&F in replacement of high efficient recess mounted LED downlighter 15 W with pressure die cast aluminium heat shrink & PC diffuser in white powder coated finish with integrated driver including necessary electrical connections complete all as specified and as directed. Make:- Bajaj Cat part No BZSLO 15W WH PRO/Havells/Crompton Greaves as approved. |
| 12 | S&FVariable Voltage and Variable frequency (VVVF) drive of capacity 15 KW, 415 Volts, ACforVVVF system including taking out old unserviceable drive complete all as specified and as directed. Make:- OTIS / JOHNSON as approved. |
| 13 | S&F in replacement of car operating panel consists of microstroke luminous push button for all floors, door open, door close, fan, light, emergency light, alarm, stop and auto attendance key, emergency light, 9 segment floor position indicator for automatic lift with SS front facia matching the existing floor cutout after dismantling the existing unit complete all as specified and as directed. Make :- OTIS / JOHNSON as approved. |
| 14 | Supply only PCB, BCB GeN2 w/ARO |
| 15 | Supply only Electronic Hooter |
| 16 | Supply only Emergency Light for GEN2 |
| 17 | Supply only MCB, SPN, 32 Amps, 10 KA |
| 18 | Supply only SP2 car board with finder relay and FCI connector |
| 19 | Supply only Screen Sensor WEC0917B, 220V AC, 212 Beams |
| 20 | Supply only SP2 Mother Board with finder relay and FCI connector |
| 21 | Supply only Battery (12V 2.5AH) |
| 22 | Supply only Cross flow fan Ningbo Brand |
| 23 | Supply only Charger unit |
| 24 | Supply only Rope Anchorage Spring- 150 mm length |
| 25 | Supply only Rope Anchorage spring seat |
| 26 | Supply only Rope Anchorage rubber seat |
| 27 | Supply only Door limit switch wrM 2 NO 2 NC-LH |
| 28 | Supply only Door limit switch with 2 NO 2 NC-RH |
| 29 | Supply only Power door contact male |
| 30 | Supply only Power door contract female |
| 31 | Supply only down light - LED - LED 15 WMake:- Philips/Bajaj/Havells as approved. |
| 32 | Supply only Pit Ladder Assembly |
| 33 | Supply only cable guide wedge yellow colour |
| 34 | Supply only PVC cable hanger wedge type yellow colour |
| 35 | Supply only DOT Matrix with dynamic scrolling |
| 36 | Supply only screen sensor extension cable with 5 Pin connector |
| 37 | Supply only hook assembly - R R (Podavance plate assembly) 26-08-CO-& 02-00-BD |
| 38 | Supply only hook assembly - EH plate assembly - Schmersal switch |
| 39 | Supply only SP2 car board wm-l finder relay and FCI connector |
| 40 | Supply only AC-DC converters with battery charger wmq Din type |
| 41 | Supply only PVC insulated 12 Core copper control cable |
| 42 | Supply only PVC Cable hanger |
| 43 | Supply only Metal lift safety gear |
| 44 | Supply only Metal elevator door rollar |
| 45 | Supply only Elevator divertor pully |
| 46 | Supply only Elevator DBG set |
| 47 | Supply only Stainless steel lift inspection box |
| 48 | Supply only MS steel lift guide rail 70mmX65mmX9 mm |
| 49 | Supply only Three phase hydraulic lift contriller |
| 50 | Supply only Elevator wire rope sencer |
| 51 | Supply only Limit switch 220 Volts, 2NO+2NC |
| 52 | Supply only Contactor 3 Phase, 415 Volts, 32 Amp |
| 53 | Supply only Elevator roller set 20-50 mm |
| 54 | Supply only Lift rail oil tank |