| 1 | Demolition of cement concrete (un reinforced) in ground floors and paving n exc. 15 cmthickness, below or above ground level complete all as specified and directed. |
| 2 | Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed. |
| 4 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 5 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground posts embedded in concrete complete all as specified and directed. |
| 6 | Dismantling mild steel work of any description complete all as specified and directed. |
| 7 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L for PCC 1:4:8 type D-2 (40mm graded aggts) as in foundation and mass concretewhere required as per direction of Engineer-in- charge complete all as specified and directed. |
| 9 | M & L for Walling of random rubble, brought upto course, built in CM 1:6 complete all as specified and directed. |
| 10 | All as per item No. 9 above but except stone complete all as specified and directed. |
| 11 | M&L for brick workwith sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 12 | M&L for providing precast ce- ment concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling).corbels, brackets, etc. (of any section indicated), landings, cover slabs, shelves etc with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed. |
| 13 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints with max depression 20 mm as specified, of random rubble walling uncoursed or brought upto course, complete all as specified and directed. |
| 14 | M&L for PCC 1:2:4 Type B1(using 20mm graded agg) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 15 | M&L for boulder filling hand packed tightly (any thickness) at back of walls over arches etc, and raising (or lowering) to the required level compete all as specified and directed. |
| 16 | M& L for flush pointing in cement mortar (1:3) to random rubble masonry complete all as specified and directed. |
| 17 | S&F in repair PVC (SWR) pipes 110 mm dia of bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 18 | M&L for rendering 15 mm thick in cement mortar 1: 4 on fair faces ofbrick work or concrete surfaces, chajja and suspended workfinished even and smooth without using extra cement, complete all as specified and directed. |
| 19 | M & L for plain cement concrete 1:2:4 type B-2, using 40mm graded crushed stone aggregates as in surfaces channels and drain complete all as specified and directed. |
| 20 | Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed. |
| 21 | Excavation in post holes each not exceeding 0.5 cum getting out, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, in any type of soil, complete all as specified. |
| 22 | M&L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape , drilling holes and notching for fixing of wires etc confirming to Fe -290 grade, E-165, complete all as specified and directed. |
| 23 | Supply only chain link MS zink coated 60gm/sqm as per IS 4826 fencing of any mesh size and 3mm dia of wire complete all as specified and directed.NOTE: This item shall be measured and paid as per actual weight or standard weight as per SSR which ever is less. |
| 24 | Fixingonly chain link fencing including line wire, any mesh size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed. |
| 25 | S & F in repair galvanised 2 strand, steel barbed wire, 2.20mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, includdigng, securing or tying at crossings with and provisiion of galavnised (Zink coating 60 gsm) mild steel wire, staples or steel pins, etc as directed each line wire to measured,complete all as specified and directed. |
| 26 | S&F mild steel round bars 10mm dia and over Gde Fe-410 W, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt 5 to 10 cmlong and dia of neck not exc 15 mm complete all as specified and directed. |
| 28 | S&F framed work such as grills, gratings,steel gate , purlin etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 290 gde E-165 complete all as specified and directed. |
| 29 | S&F framed work such as portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.and similar work conforming to Fe 290 gde E-165 complete all as specified and directed. |
| 30 | M&L for preparation of new untreated surfaces of steel any description over 10 cms width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. |
| 31 | M&L for applying two coats of cement base paint over a coat of cement primerincluding preparation of new plastered or un-plastered surfaces of wallcomplete all as specified and directed. |
| 32 | M&L for 75mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base in floor etc, finished even and fair complete all as specified and directed. |
| 33 | Cleaning of PVC/ Cemented water tank of capacity not exceeding 1000 ltr including disinfecting with chlorine and finally washing with clean water complete all as specified and directed. |
| 34 | M&L for chequered cement concrete tiles with chemical resistant coating if size 300x300x 25mm thick, set & jointed in neat cement slurryin floors and pointed with grey cement mixed with pigments, laid over and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 35 | M&L for sand filing under floor incl spreading and levelling in layers not exc 25 cm thick complete all as specified and directed. |
| 36 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade,laid jointed pointed with grey cement and no pigments,complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE. |
| 37 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments,complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE. |
| 38 | Cleaning of blockage of Water Closet (Indian or European), trap &pipe line upto first manhole manually by Roding and making it fully functional by flushing with water to entire satisfaction of Enginerr-in-charge including removing the deposited sludge/solid/liquid material, outside MD land and burring in borrow pits including covering with fresh mud, complete all as specified and directed by Engineer-in-charge.Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer. |
| 39 | Opening of cover (of any description and size) of septic tanks and soakage wells/pits, de-sluding / de-watering contaminatedwith fine waste materials ( liquid sludge) alongwith solid waste from septic tank and soakage wells/pits of any capacity/depth by mechanical pumping (Truck mounted mechanical machine) / manually making it fully functional to to entire satisfaction of Engineer-in- charge and and removing & depositing the sludge outside the periphery of defence land at a minimum distance of 50 m from nearby living accn and burring in borrow pits including covering with fresh mud and refixing the cover after cleaning / removing the liquid waste material of septic tanks / soakage wells / pits including cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces complete all as specified and directed by Engr-in-Charge.Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit is deemed to be included in the unit rate to be quoted by tenderer. |
| 40 | M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position and testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch |
| 41 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity complete all as specified and directed. |
| 42 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity complete all as specified and directed. |
| 43 | Supply only Fan/blower electric motor single phase 230 V complete for inner unit complete all as specified and directed. |
| 44 | Supply only Fan/blower electric motor single phase 230 V complete for outerunit complete all as specified and directed. |
| 45 | Supply only Starting capacitor of suitable capacity complete all as specified and directed. |
| 46 | Supply only Running capacitor of suitable capacity complete all as specified and directed. |
| 47 | Supply only Overload protection of suitable capacity complete all as specified and directed. |
| 48 | Supply only Drain pipe for Split unit PVC 20mm dia complete all as specified and directed. |
| 49 | Supply only Fan blade of suitable size for outer unit complete all as specified and directed. |
| 50 | Supply only Remote control kit complete for Split type AC complete all as specified and directed. |
| 51 | Supply only Condencing unit of Split type AC 2 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed. |
| 52 | Supply only Condencing unit of Split type AC 1.5 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed. |
| 53 | M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing andcleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch |
| 54 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity complete all as specified and directed. |
| 55 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity complete all as specified and directed. |
| 56 | Supply only Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity complete all as specified and directed. |
| 57 | Supply only Auto cut thermostate of suitable capacity for window AC 1.5/2 Ton complete all as specified and directed. |
| 58 | Supply only Overload protection for Window type AC 1.5/2 ton capacity complete all as specified and directed. |
| 59 | Supply only Grill for window AC of suitable size/shape /model as required at site complete all as specified and directed. |
| 60 | Supply only Fan blade of suitable size for window type AC unit complete all as specified and directed. |
| 61 | Supply only Fan/blower electric motor single phase 230 V complete all as specified and directed. |
| 62 | M&L for complete servicing and repair of Water Cooler any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items of Sch |
| 63 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 40/80 Ltrs complete all as specified and directed. |
| 64 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 60/120 Ltrs complete all as specified and directed. |
| 65 | Supply only Fan/blower electric motor single phase 230 V complet for water cooler 40/80 or 60/120 Ltrs capacity water cooler complete all as specified and directed. |
| 66 | Supply only Running capacitor of suitable capacity complete all as specified and directed. |
| 67 | Supply only Starting capacitor of suitable capacity complete all as specified and directed. |
| 68 | Supply only Auto cut thermostate switch for water cooler complete all as specified and directed. |
| 69 | Supply only Overload protector for water cooler of any capacity complete all as specified and directed. |
| 70 | Supply only Fan blade of suitable size complete all as specified and directed. |
| 71 | Supply only Push cock/soft closing tap brass chromium plated of size 15 mm complete all as specified and directed. |
| 72 | Supply only PVC connection pipe 600 mm long, both end screwedfor water cooler complete all as specified and directed. |
| 73 | Supply only ball valve PVC 15mm size for water cooler 40/80 ltr capacity complete all as specified and directed. |
| 74 | M&L for complete servicing and repair of refrigerator/deep freezer of any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge.Note:- Unsv accessories will be measured and paid seperately under respective items of Sch |
| 75 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 165 Ltrs capacity complete all as specified and directed. |
| 76 | Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 286/310 Ltrs capacity complete all as specified and directed. |
| 77 | Supply only Auto cut thermostate switch for Refrigerator defrosts type complete all as specified and directed. |
| 78 | Supply only Overload protectors for regrigerations upto 310 Ltrs capacity complete all as specified and directed. |
| 79 | Supply only Copper strainer filter for reftrigerator complete all as specified and directed. |
| 80 | Supply only Relays suitable for refrigerators upto 310 ltr capacity complete all as specified and directed. |
| 81 | Supply only Door switch for refrigerator complete all as specified and directed. |
| 82 | Supply only Door spring for refrigerator complete all as specified and directed. |
| 83 | Supply only Freezer chest door suitable for 286/310 Ltr capacity complete all as specified and directed. |
| 84 | Supply only Magnetised door lock rubber strip \"D\" type for regrigerator 286/310 Ltr cacpacity complete all as specified and directed. |
| 85 | Supply only Evaporator coil assembly 165 ltrs capacity regrigerator with copper pipe complete all as specified and directed. |
| 86 | Supply only Evaporator coil assembly 266/310 ltrs capacity regrigerator with copper pipe complete all as specified and directed. |
| 87 | Supply only Fan motor for chiller unit as per existing make complete all as specified and directed. |
| 88 | Supply and filling gas charging required to the System of suitable type R-34/12/32 /R22 or as per existing at site complete all as specified and directed. |
| 89 | Supply and filling gas charging required to the System of suitable type 134a or as per existing at site complete all as specified and directed. |
| 90 | S&F in repair base tray of window type AC 1.5/2 Ton capacity unit complete all as specified and directed including the following:-(a) Removing of compressor condenser, wiring kit, from base tray(b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted.(c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch |
| 91 | S&F in repair base of water cooler of any capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray(b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. (c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch \"A\" |
| 92 | S&F in repair Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 32 Amps MCB SP complete all as specified and directed. |
| 93 | S&F in repair 6-32 Amps MCB SP, 10 kA, C series, complete all as specified and directed. |
| 94 | S&F swing motor suitable for split AC of capacity 1.5/2 TR, complete all as specified and directed. |
| 95 | Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 2.50 Sqmm complete all as specified and directed. |
| 96 | Supply and fix in repair capillary copper tube for window , split, water cooler, refrigerator complete all as specified and directed. |
| 97 | Taking down of split AC 1.5/2 T capacity from existing location to refixing in another location incl both inner and outer units (filling up gas if necessary ) incl connected accessories in complete all as specified and directed by Engr-in-Charge. |