| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation / trenches for laying pipes/ cable and similar work and getting out in soft /loose soil etc complete all as specified and directed |
| 2 | M&L for PCC (1:4:8)type D2 (using 40mm graded stone aggregate)as in foundation filling and mass concrete complete all as specified and directed. |
| 3 | M&L Brick work using old size sub class \"B\" bricks straightor curved on plan exc 6 m mean radius built in cement mortar (1:6)complete all as specified and directed. |
| 4 | M&L Providing, type B0 1:2:4 (12.5 mm graded aggregate) cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 5 | M&L broken stone hard core of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rolled/ rammed to a true surfaces complete all as specified and directed. |
| 6 | M&L for PCC type E-2 (1:5:10) (using 40mm graded stone aggregate) asin sub base of flooring and mass concrete etc. complete all as specified and directed. |
| 7 | M&L for25mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in flooring and finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 8 | M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed. |
| 9 | M & L for preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed. |
| 10 | M&L PCC (1 : 3 : 6)type C2, 75 mm thick ( by using 40mm graded stone aggregate) for plinth pretection finishing even and smooth without using extra cement with necessary expension joints at every three metre or change of directiion complete all as specified & directed. |
| 11 | M&L Non skid mat finished coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of Each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including15mm thick screed bed or bedding layer of cement mortar (1:6 ) for laying floor finishes all as specified and directed . |
| 12 | M&L Glazed coloured ceramic tiles in vertical surfaces 450mm x 300 mm x 7 mm thick (pattern/digital tiles)set and jointed in neat cement slurry and pointed in white or colour cement to match over plastering 10mm thick on fair faces of brickwork or concrete surfaces in CM (1:4)to receive wall finishes as specified and directed .. |
| 13 | S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm palin colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing. |
| 14 | S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M S Frame shall be covered with heat moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock and bottom rail on either side & as gap insert for tip rail & bottorm rails; Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/seated to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site as per specification & drawing. |
| 15 | S&F mild steel butt hinges cold rolled of size 100mm medium weight. |
| 16 | S&F Aluminium anodised barrel tower bolts of extruded section of 125mm size etc complete all as specified and directed. |
| 17 | S&F Aluminium handles, cast type anodised of size 125mm etc complete all as specified and directed. |
| 18 | S&F 300 mm long aluminium anodized, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 19 | M & L PVC (SWR) couplers75 mm complete all as specified and directed. |
| 20 | S & FVitreous China Urinal, Half stall type, white), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) etc complete all as specified and directed. |
| 21 | S& F Gun metal glove or gate valves. With iron wheel head, screwed both ends for 20 mm iron pipe and fixed screws complete all as specified and directed |
| 22 | S&F PVC connection 15mm size with PTMT nuts of length 450mm etc complete all as specified and directed. |
| 23 | S&F vitreous china urinal partition white of size 310 mm X 700 mm complete all as specified and directed. |
| 24 | S & F rotational moulded polyethylene water storage tanks tripple layer white in colour 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT Float valve complete all as specified. |
| 25 | S&F Steel Tubes Medium Grade Bore of tube in 15mm galavanised with all fitting laid in walls, ceiling or laid in floors etc complete all as specified and directed. |
| 26 | ....ditto but 20 mm bore tubing ...ditto.. |
| 27 | M&L of 75 mm dia.PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete.all as specified and directed . |
| 28 | M&L PVC (SWR) gully trap 125/110 mm, setting and jointingto waste pipe fixed in cement concrete type B-1 (1:2:4) complete.all as specified and directed . |
| 29 | Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and directed. |
| 30 | Removal of surplus excavated soil to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point all as specified and directed. |
| 31 | S & F PVC ( SWR )pipe 75 mm dia single socketed in any length with rubber ring joints ,fixed to wall or laid in floor complete all as specified and directed. |
| 32 | S & F PVC ( SWR ) bend75 mmcomplete all as specified and directed. |
| 33 | S & F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 34 | S&F for Welded steel wire fabric supplied and fixed complete to wood or steel members in available size weightnot exc. 4.00 kg per Sqm complete all as specified and directed. |
| 35 | M & L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed. |
| 36 | M&L for preparation new surface of steel surfaces and two coat of synthetic enamel paint over a coat of red oxide primer on Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tintcomplete all as specified and directed |
| 37 | Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed. |
| 38 | M & L for 100mm thick broken stone & boulders hardcore of guage not exc 63mmdeposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 39 | M&L for 100 mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base flooring complete all as specified and directed |
| 40 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed |
| 41 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping & benching etc complete all as specified and directed. |
| 42 | M & L for Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed |
| 43 | Supply and laying Reinforced concrete pipes, 200mm dia, class NP2, laid and jointed complete with collars etc complete all as specified and directed |
| 44 | M & L for Reinforced cement concrete Nominal mix type B1 1:2:4(using 20 mm graded stone agg) in foundation, footings, Plinth beam etc complete all as specified and directed. |
| 45 | M & L for Reinforced cement concrete Nominal mix type B1 1:2:4(using 20 mm graded stone agg) in columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 46 | M & L for Reinforced cement concrete Nominal mix type B1 1:2:4 (using 20 mm graded stone agg) in beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed. |
| 47 | M & L for Reinforced cement concrete Nominal mix type B1 1:2:4 (using 20 mm graded stone agg) in Slabs supported on walls,beams and columns in floors,roofs, landings,balconies,canopies, deck slabs and inshelves etc complete as specified and directed. |
| 48 | M&L of mild steel TMT Bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed . |
| 49 | M&L of mild steel TMT Barsbut 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed . |
| 50 | M&L Brick work using old size sub class \"B\" bricks straightor curved on plan exc 6 m mean radius in half brick thick wallbuilt in cement mortar (1:6) complete all as specified and directed. |
| 51 | M&L for Cement concrete type D- 2, 1:4:8 (40mm gradedaggregate) 75mm thick in sub base in flooring and mass concrete etc. complete all as specified and directed. |
| 52 | M & L Rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement. |
| 53 | M & L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of chalk whitening complete. |
| 54 | M & L Rendering 5mm thick in CM (1:3) on fair faces of brick work ceilling concrete surfaces to be finished even and smooth without using extra cement. |
| 55 | M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceilling complete. |
| 56 | Supply & fixing Steel windows or ventilators, fixed type, with glazing barscomplete all as specified and directed. |
| 57 | M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished susrfaces of concrete complete all as specified and directed. |
| 58 | M&L for Formwork to sides and soffit of floor or roof beams,beam haunching, girders,bressum-mers, lintel, cantilevers, shelves including supports,overhangs,etc.also plays between floors and beams, etcfor rough finished susrfaces of concrete complete all as specified and directed. |
| 59 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor rough finished susrfaces of concrete complete all as specified and directed. |
| 60 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thickfor rough finished susrfaces of concrete complete all as specified and directed.. |
| 61 | S&F Brass chromium plated shower rose 125 mm including fixingwith Swivel shower of PTMT any colour for fixing with 15mm pipe(Minimum weight 40gms) complete all as specified and directed. |
| 62 | S&FBrass CP wall mixer with L bend for mixing hot & cold water screwed down for iron pipe and fixed to 15mm bore pipe complete all as specified and directed. |
| 63 | S & F Brass chromium plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 64 | M & L PVC (SWR) couplers110 mm complete all as specified and directed. |
| 65 | S&F Vitreous China Wash Basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets , 32 mm PVC waste pipe, 32 mm PTMT Waste coupling and 15 mm dia Pillar taps fancy type chromium plated complete all as specified and directed |
| 66 | S&F Low Level Flushing System PVC valveless syphonic action type, 10 ltrs capacity white, with inlet, ball float and handle including brackets complete all as specified and directed. |
| 67 | S&F Chromium plated bib tap Chromium plated fancy type screwed down for iron pipe and fixed to 15mm bore pipe complete all as specified and directed. |
| 68 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 69 | S&F Soap dish, any type, fixed to plugs with chromium plated brass screws |
| 70 | S&F invitreous china squating pan \"Orrisa\" patern size 580 mm x 440 mm white with \"P\" or \"S\" trap front or back inlet with integral foot rest including provision of lime concrete bedding complete all as specified and directed . |
| 71 | S & F PVC ( SWR )pipe 110 mm dia single socketed in any length with rubber ring joints ,fixed to wall or laid in floor complete all as specified and directed. |
| 72 | M & L PVC ( SWR ) vent cowl 75 mm complete all as specified and directed. |
| 73 | S & F PVC ( SWR ) bend110 mm completeall as specified and directed. |
| 74 | S&F sheet glass 3 mm thick ordinary quality and gazing with oil putty in square nexc 0.5 sqm each panel all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2.0 Core incl dismentaling complete all as specified and directed. |
| 76 | S & F in of 25mm bore GI Tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS Clapms and nut and bolts/washer complete all as specified and directed. |
| 77 | M & L Sand cushioning for cables complete all as specified and directed . |
| 78 | M & L for old size brick well burnt, laid flat, for cable protection complete all as specified and directed. |
| 79 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed |
| 80 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed |