| 1 | Taking down unserviceable aluminium /copper point wiring (fan, power) complete including fittings and fixtures such as switches, ceiling roses, regulators, etc removing materials (credit for above items should be made as per conditions seperately)and making good the disturbed surface all as directed. |
| 2 | M&L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etcfixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor and connected to earth dolly etc,complete all as specified and directed. |
| 3 | One point controlled by one switch / regulator complete. |
| 4 | All as per item No 2 above but complete with 1100volt grade PVC insulated unsheathed multistranded wire with 2.5 sqmm coppercablethrough casing and cappingof suitable size and one run of 2.5 sqmm copper cable as earth continuity conductor including connecting withearth dollyfor Geyser complete all as specified and as directed. |
| 5 | S&F in repair switch piano, flush type single pole, one way 5 Amp for ceiling fan complete all as specified and directed. |
| 6 | Supply and fix in repair switch socket combination 2 in one 3 pin 5 A and 2 pincombined flush type complete all as specified and directed |
| 7 | Supply and fix in repair switch socket combination 2 in one 3 pin 5 A and 3 pin 15 A combined flush type complete all as specified and directed |
| 8 | Supply and fix in repairs PVC ceiling rose 3 terminal 230 V isolatedtype, complete all as sspecified and directed. |
| 9 | S & F in repairs Ceiling fan regulator electronic step switch type/socket type(Matching to existing location), suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as specified and directed. |
| 10 | S & F in repair step type modular electronic fan regulator flush type 2 module for 1200 / 1400 mm sweep ceiling fan including taking down existing regulatorcomplete all as specified and directed. Make: Matching to existing location. |
| 11 | S & F in repair SP 5 To 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 12 | Checking and dismantling of ceiling fan of any make and sweep 1200 mmfrom its installed location servicing the fan by cleaning, greasing, oiling, painting with two coat of existing colour including replacement of worm out nut bolts with rubber reel, split pins, quarter pin, push bearing, ball bearing, Fan blade, Fan motor, Rewinding, Down rod, Capacitor and check nutsand installing back to its original position complete all as specified and directed.Note:- M&L for painting, nut bolts with rubber reel, split pins/quarter pin, push bearing, ball bearing, Fan blade, Fan motor, Rewinding, Down rod, Capacitors and check nuts etc shall be measured and paid seperatly. |
| 13 | S & F in repair Fan motorComplete suitable for 1200mmsweep ceiling FanNote : As per specification of manufacturer\"s make obtained from site. |
| 14 | Supply and fix in repair Fan Blade suitable for 1200 mm Sweep ceiling FanNote : As per specification of manufacturer\"s make obtained from site. |
| 15 | S & F in repairsrubber reel with MS nut Bolt,split/quarter pin for hanging ceiling fan suitable for Ceiling fan complete all as specified and directed . |
| 16 | S & F in repairs ball bearing suitable for size of Ceiling fan any type and any make complete all as specified and directed. |
| 17 | S & F in repair ceiling fan down rod for hanging ceiling fan of suitable length matching to the existing location complete all as specified and directed. |
| 18 | M&L for Painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filter, two coats after cleaning att dust etc complete all as specified and directed. |
| 19 | S & F in repairs capacitor of capacity 2.5mfd, 230 V for ceiling fan including removing old one complete all as specified and directed. |
| 20 | Checking and dismantling of Exhaust fan of any make (Plastic/Metal) and sweep up to 300 mm from its installed location servicing the exhaust fan by cleaning, greasing, oiling, painting with two coat of existing colour, Fan blade, Fan Motor, ball bearing, anchor fastner bolt, Rewinding, capacitorsand installing back to its original position complete all as specified and directed. Note:- painting, Fan blade, Fan Motor, ball bearing, anchor fastner bolt, Rewiring, Capacitor andcheck nuts shall be measured and paid seperatly |
| 21 | S & F in repair Fan motor complete suitable any make and sweep up to 300 mm Sweep exhasut Fan (Metal body) matching to existing locationNote : As per specification of manufacturer\"s make obtained from site. |
| 22 | S & F in repair Fan Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan (Metal body) matching to existing location |
| 23 | S & F in repairs Exhaust fan body/frame suitable any make and sweep up to 300 mm exhaust fan(Metal body) Matching to existing location complete all as specified and directed. |
| 24 | S & F in repairs capacitor for Exhaust fan (Metal) of capacity Matching to existing location, 230 V for Exhaust fan including removing old one complete all as specified and directed. |
| 25 | M&L for Painting of Exhaust fan(Metal body) complete, in situ with synthetic enamel paint by spraying including filling cavities with filter, two coats after cleaning att dust etc. |
| 26 | S & F in repair Fan motor complete suitable any make and sweep up to 300 mm Sweep exhasut Fan (Plastic body) matching to existing locationNote : As per specification of manufacturer\"s make obtained from site. |
| 27 | S & F in repair Fan Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan (Plastic body) matching to existing location. |
| 28 | S & F in repairs Exhaust fan body/frame suitable any make and sweep up to 300 mm exhaust fan(Plastic) Matching to existing location complete all as specified and directed. |
| 29 | S & F in repairs capacitor for Exhaust fan (Plastic) of capacity Matching to existing location, 230 V for Exhaust fan including removing old one complete all as specified and directed. |
| 30 | S & F in repairs anchor fastner bolt suitable any make and sweep up to 100 mm for Exhaust fan or Geyser complete all as specified and directed. |
| 31 | M&L for Rewinding of u/s ceiling / exhaust fan and opening the body cover of ceiling fan, exhaust fan, any type, any make and cutting the existing winding without damaging the stator removing the coil insulation and rewinding with new wire of suitable gauge with correct number of turns of auxiliary and main winding , varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing, refixing and commissioning complete including transportation from area of AGE E/M II to workshop complete all as specified and directed for the following sizes here in after Sl No 30.01 to 30.02 :- |
| 32 | Ceiling Fan 1200mm sweep |
| 33 | Exhaust fan up to 300 mm sweep (Plastic/Metal) |
| 34 | Removing inlet and outlet waterconnection, taking down existing Geysers storage type10/15/25/50 Ltr capacity and then checking of thermostate , heating element, 15 Amp Plug Top and socket, PVC connection pipe hot and cold, NRV and safety devices inner control valves, cables etc including cleaning of inner storage tank complete and fixing back testing complete all as directed.Note :- Unserviceable items to be replaced shall be measured and paid separately. |
| 35 | S & F in repairsthermostat BI- metal thermal relay suitable for 10/15/25 ltrs geyser complete all as specified and directed. |
| 36 | Supply & Fix in repairs indicator lamp for geysers complete all as specified and directed. |
| 37 | S & F in repairs heating element threaded/ push type1500 watts / 2000 watts for 10/15/25 Ltr geysers of any make complete all as specified and directed. |
| 38 | S & F in repairs PVCconnection heavy duty 15mm size with PTMT nut of length 450 mm for hot /cold water connection |
| 39 | S&F in repairs PVC three core cable 2.5 sqmm 1100volt sheathed cable copper conductor complete all as specified and directed. |
| 40 | S & F in repairs 15 Amps plug Top for geysers complete all as specified and directed. |
| 41 | S & F in repair suitable non return valve for any type of Geyser complete all as specified and directed. |
| 42 | S & F in repair MCB protected socket of 20 Amps with plastic enclosure for surface mounting including plug top of 20 Amps complete with one single pole 20 Amps MCB including disconnecting and removal of old one complete all as specified and directed. |
| 43 | Checking and attending electrical complaints of single phase/three phase for continuing electric supply (like No light / Short circuit / non working fittings / fixtures etc) for Ceiling Fan/ Exhaust Fan, Gyser and faulty Energy meterwith connecting calibration testincluding replacement & carrying out theminor repair likefixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.50 mtr length etc maintenance work on all working days complete all as specified and as directed.Note:(i) Rates inclusive of all small items like screws, wire etc.(ii) Contractors are advised to visit the sites before quoting their rates.(iii) Rep of the contractor shall receive complaintsin morning 0900 hrandgive feedback on daily basis to concerned JEE/M.(iv) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and paid in respective items of CA and adequate stock shall be held all the time by contractor. |
| 44 | (v) Anynature of electrical complaint, the entire responsibilty of rectification lies with the contractor. (vi) Contractor shall be penalised @ Rs. 500/- per day per complaint, if he/she fails to attend the complaint within 12 hours.(vii) All serially numbered complaint docket will be provided by contractor and cost of docket included in the rate quoted for the items.(viii)All T&P, safety gadgets shall be provided by the contractor.(ix) Contractor shall maintain the maintinance register showing all daily complaints recieved and shall maintain job cards for attending complaints. The signature of the user shall be obtained on the job card showing the material incorporated in the work after completion of the job with date.(x) Payment to contractor released after submission of these complaints duly rectified within time and duly signed by contractor, JE, and Engineer-in-Charge in RAR/Final bill. |
| 45 | S & F in repair meter box made out of 2 mm thick CRCA Sheet with suitable lockingarrangement including necessary fixing arrangement for one number single phase energy meter all as directed by Engineer-in-Charge. |
| 46 | S & F in repairs for louvers of any make up to 300 mm exhaust fan (metallic/Plastic), at any Bldg and at any Floor complete all as specified and as directed. |