| 1 | M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site.Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction.(b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.Note rate quoted up to G+3 bldg including scaffolding |
| 2 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete. |
| 3 | M & L for Virified Ceramic tiles dark shed 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match on 15mm thick screed bed in CM 1:6 |
| 4 | M&L for coloured ceramic tiles 350x250x7mm or 450x350x7mmthick on vertical surfaces on skirting dados and risers to steps etc including rendering 10mm thick cement mortar in CM 1:4 ,complete all as specified and directedby Engr-in-Charge. |
| 5 | Dismantling boarding any description (board/plywood) fixed in any position with screw, complete all as specified |
| 6 | S&F WPC board, S&F factory made 18mm thick single extruded WPC (Wood Polymer Composit) Solid Board having density not less than 600 kg/ Cbm one side white and other side of board laminated with PVC Foil including finishing all edges at all level for making edge lipping /beading or .. 50 mm thick PVC sheet lipping at all 4 edgesusing binding tape, Solvent, screws, stainless steel, Piano hinges / self closives box type hinges etc Manufactured by ISO 9001-2008 certified company. |
| 7 | S&F Hasp and staple, 100mm size, safety type, aluminium anodised brass hinge pin including bolt to hinge plate & fixed withscrews, complete all as specified. |
| 8 | S&F continuous (Piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30 mm, complete all as specified. |
| 9 | Taking up or down 15 mm dia GI tubing and connections including cleaning for re-fixing, complete all as specified. |
| 10 | S&F 15mm dia GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors complate all as specifiede and diected. |
| 11 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etccomplete all as specified and directed |
| 12 | M&L for rendering 15mm thick in CM 1:4 on fair facesof brick work or concrete surfaces firnished fair and even without using extra cement up to hieght of four storey ,including scaffolding complete. |
| 13 | Material and labour for preparation of new plastered surfaces as of walls and applying Twocoats of weather proofing exterior acrylic emulsion paint over one coat of primer from the same manufacturerwhite lime wash complete all as specified and directed. |
| 14 | M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type and also taking down cement plaster on brick/concrete surfaces, including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. Make: Asian Paints or equivalent in Sikka, Fosroc and STP Ltd.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas. |
| 15 | M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Notes: (1) The work shall be executed through authorised applicator of manufacturer only.(2) Authrised Applicator shall be approved by GE before starting of work.(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Ten (10) years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor\"s dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer. |
| 16 | Disconnecting existing water tanks, settingaside (or lowering if required) for cleaning,repairing and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes and reconnecting and refixing in position for tanks capacity exc 500 and n.exc 1000 ltr complete all as specified |
| 17 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for |
| 18 | M&L for PCC( 1:3:6) type C-2 using 20mm graded stoneas in padding on roof correction of slope and roof kerbs all as specified and directed. |
| 19 | S & F in repair stainless steeldrapery Rod 25mm dia, including wooden side caps, brackets, and rings @ 120mm c to c, complete all asspecified and directed. |
| 20 | M&L for preparation of old decoreated/undecoreatedexternal wall / Ceilingapplyingtwo coats of cement base paint by spray gun/ spray machine up to 8 storey bldg complete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+4 bldg including scaffolding |
| 21 | M&L for preparation of old decoreatedexternal wall / internal wall/Ceiling surface of existing treatmentby scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc.or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possibleup to 8 storey bldgcomplete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+4 bldg including scaffolding |
| 22 | M&L for preparing the entire surface withapplying2-3 mm thick birla/ JK wall care putty on walls and ceiling surface finished even and smoothcomplete all as specified and directed. |
| 23 | M& L for preparing the entire surface withapplyingpriming surface with alklai resistance priming paint on walls and ceiling surface finished even and smoothcomplete all as specified and directed. |
| 24 | M&L forexternal wall / Ceilingapplyingtwo coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine up to 3 storey bldg complete all asspecified and all as directed by Engr- in-charge.Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes.2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+4 bldg including scaffolding |
| 25 | M&L for Preparation of old painted surfaces of woodsurfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed.Note rate quoted up to G+4 bldg including scaffolding |
| 26 | M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying onecoat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note rate quoted up to G+4 bldg including scaffolding |
| 27 | M & L preparation of surface for Writing building Numbers on building by applying black synthetic enamel paint on white base all as specified and directed by Engr-in-charge |
| 28 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 29 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet coverfor housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge. |
| 30 | One light/fan point controlled by oneway switch |
| 31 | One bell/buzzer point controlled by one bell push |
| 32 | One light point controlled by two Nos two way switches |
| 33 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 34 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board. |
| 35 | All as per item No 29 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 36 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc complete all as specified and directed by Engineer in charge for the followings:- |
| 37 | One light/exhaust fan point controlled by oneway switch |
| 38 | One bell/buzzer point controlled by one bell push. |
| 39 | One light point controlled by two Nos two way switches. |
| 40 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 41 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board. |
| 42 | All as per item No 31 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge |
| 43 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 44 | M&Lin replacement switch modular type 6amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 45 | M&L in replacement Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 46 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 47 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 48 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 49 | M&L in replacement modular stepped type electronic fanregulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 50 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 51 | M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 52 | M&L in replacement switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge . |
| 53 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 54 | M&L in replacement socket outlet5 pin 6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 55 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 56 | M&L in replacement bell electric (ding dong) 230 volt, SPall complete all as specified and directed by Engineer in charge . |
| 57 | M&L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 58 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge . |
| 59 | M&L in replacement sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade20Amps complete with onesingle poleMCB \"C\" series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 60 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2000 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>70, Power Factor > 0.90, THD< 10%, colour temperature-6500K, surge protection 2.5 KV in CM, IP-20 protected, Class-1, Short circuit and over circuit protection, voltage range-180 to 270 Volts AC, temperature range 0 to 45 Degree C minimum andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 61 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI >70, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range-150 to 270 volts AC, temperature range 0 to 45 Degree C minimum, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 62 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.90, driver with Voltage range 180-270V, Temperature range 0 to 45 Deg minimum, Driver efficiency >85%, THD<10%, CRI>70, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 63 | S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge. |
| 64 | Supply and fix surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 100 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >70, Power Factor >0.90, Driver with voltage variation range-150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 65 | S&F 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarieshould more than 110 lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:65 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 170-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 66 | M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out /unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge. |
| 67 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 68 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 69 | Supply and fixin repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 70 | Supply and fixin repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 71 | Supply and fixin repair MCB SPN 32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 72 | Supply and fixin repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 73 | Supply and fixing Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 74 | Supply and fixing exhaust fan 300 mm sweep (steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 75 | Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 76 | S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warranty on product.Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 77 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEEfive star rated voltage range 140 - 280 volts with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge. (Against BLDC converson). Old fan deposited to MES yard. |
| 78 | S&F in replacement sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 79 | Supply and fix in replacement sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 80 | Supply and fix in replacement sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. |
| 81 | Supply and fix in replacement sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 82 | S&F plug top, 3 pin,20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 83 | S&F socket 3 pin20 amp earth metal clad(ISImarked) complete all as specified and directed by Engineer in charge . |
| 84 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 85 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 86 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 87 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 88 | M & Lin replacement foronlysingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 89 | M & Lin replacement foronlysingle core PVC insulated cable4Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 90 | M&L in replacement copper cable flexible 2 corePVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. |
| 91 | Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height not less than 1.0 meterwith IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge. |
| 92 | Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources. |
| 93 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. |
| 94 | Supply only heating element of 2 KW any type with nut bolt washercomplete all as directed. |
| 95 | M&L for fan motor of ventilating fan 250/300mm sweep plastic body operated on single phase 230 volts 50Hz electric supply as per sample complete including making necessary electrical connections and testing on site after replacement all as specified and directed by Engr-in-Charge at site. |
| 96 | S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Wattsnot less than 3600lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy>100 lm/W, CRI>70, color temperature >5700 K, IP 20, Power factor >0.90, THD<10%, 25000 burning hours , Ambient temperature 0 to 45 Deg C minimum, driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangements fixed complete all as specified and directed. |
| 97 | Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge. |
| 98 | Supply and fix white cover plate with frame 3 Module complete all as specified and directed by Engineer in charge. |
| 99 | Supply and fix white cover plate with frame 4 Module complete all as specified and directed by Engineer in charge. |
| 100 | Supply only replacement of capacitor 3.15 Mfd,240 V complete all as specified and directed. |
| 101 | Supply only replacement of capacitor 1.5 Mfd,240 V complete all as specified and directed. |
| 102 | Supply,installation,testing and commissioning of self priming regenerative pump 0.5/0.37 HP/KW, single Phase 220 volt+18%, discharge range 1950-450 LPH, head range 6-21 mtr insulation class ‘F’ of size 25x25mm complete including mounting bracket of angle iron of suitable size with necessary nuts, bolts and washer etc and making electrical connection with suitable size copper multi stranded cable of suitable length and connecting with GI/ uPVC/cPVC water supply line of any dia/size alongwith accessories such as tee,bend, elbow and socket etc including making bypass arrangement for any fault in pump in future to provide uniterrupted water supply to building all as specified and directed at site by Engr-in-Charge. Model No NILE PLUS II of Crompton or equivellent in Kirloskar/Havelles. |
| 103 | S&F in replacement twin core cable 6 Sqmm PVC insulated heavy duty 1100 volts grade, aluminium conductor drawn through and including 25 mm dia non metallic rigid PVC conduit and including conduit accessories such as bend,elbow and tee etc including burial in ground at a depth as required including excavation of earth, returning filling in and including removal of excavated soil to a distance as directed at site. |
| 104 | Schedule of Credit |