| 1 | Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame,complete all as specified and directed. |
| 2 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 3 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge |
| 4 | Butt hinges 100mm long, medium weight, stainless steel, complete all as specified anddirected. |
| 5 | 150 mm size aluminium anodized, barrel tower bolt (ISI Marked) of extruded section complete all as specified and directed. |
| 6 | 150mm size aluminium alloy handle (ISI Marked), fabricated type,complete all as specified & directed. |
| 7 | Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. |
| 8 | 300mm MS ordinary rat tail rod pattern spring incl roller plate complete all as specified and directed. |
| 9 | Factory made steel window box type with side hung shutters including box type hinges and oneshop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete with glazing bars, dovetailed or welded fixed with and including MS flat of suitable size for fixing grills and guards bars etc, fixed as in repair complete all as specified. |
| 10 | Factory made steel window box type with side hung shutters including box type hinges and oneshop coat of red oxide primer, 125mm steel handle-02 Nos mild steel ISI marked tower bolt 125mm size (minimum 2 for each shutter) complete without glazing bars, fixed as in repair dovetailed or welded , complete all as specified. |
| 11 | Factory made box typesteel ventilators including oneshop coat of red oxide primer, hinges, tower bolts 100 mm, steel handles and steel peg stay complete without glazing bars devetailed or welded, fixed as in repaircomplete all as specified and directed. |
| 12 | Factory made steel ventilators top hung shutter including oneshop coat of red oxide primer, hinges, tower bolts 100 mm, steel handles and steel peg stay complete without glazing bars devetailed or welded complete all as specified and directed. |
| 13 | Framed work such as grill guard bars etc welded to steel frame MS round/square bar conforming to Fe 290 Gde-E 165, complete all as specified and directed. |
| 14 | 4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading)in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 15 | 4mm thick figured glass pin head type ordinary quality any size and in any type of frame and glazing with oil putty (or beading)in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 16 | Galvanised mild steel wire cloth 0.56 mm nominal dia of wire & avg width of aperture 1.18 mm in fixed with tinned tacks, complete all as specified and directed. |
| 17 | Preparation of new or previously untreatedsteel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide, zinc chrome complete all as specified and directed. |
| 18 | Preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint complete all as specified and directed. |
| 19 | Applying two coats of synthetic enameled paint on steel and iron surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified & directed. |
| 20 | Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete all as specified and directed. |
| 22 | Glazed coloured ceramic tiles in vertical surface of size 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 23 | Non skid ceramic coloured tiles7 to 8 mm thick square /rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed. |
| 24 | Non skid ceramic coloured tiles7 to 8 mm thick square /rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed. |
| 25 | Non skid ceramic coloured tiles7 to 8 mm thick square /rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in skirting / dado etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick bedding layer in CM 1:4, complete all as specified and directed. |
| 26 | Taking down existing plaster of any description on brick wall/ concrete surface including raking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed. |
| 27 | Rendering 15mm thickin Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. |
| 28 | Rendering 15mm thickin Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. |
| 29 | 5mm thick rendering in Cement and Sand mortar 1:3 on ceiling, chajja surfaces (concrete surfaces) finished even and smooth without using extra cement, complete all as specified and directed. |
| 30 | Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement, including using water proofing compound, including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified.Note : WPC shall be measured and paid separately. |
| 31 | Rendering 15mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement (upto 4 storey building), necessary scaffolding & safety arrangement for plaster upto & including 4 storey building, including taking down cement plastercomplete all as specified. |
| 32 | Rendering 10mm thick in Cement and Sand mortar 1:4 overfair faces of brick / concrete ,finished even and smooth without using extra cement (upto 4 storey building), necessary scaffolding & safety arrangement for plaster upto & including 4 storey building, including taking down cement plastercomplete all as specified. |
| 33 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 34 | Three coats of white wash on plastered or unplastered ceilingsurfaces including preparation of new surfaces complete all as specified and directed |
| 35 | Preparation of new plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and directed. |
| 36 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper overand including a coat of primer complete all as specified and directed. |
| 37 | Preparation of old decorated wall surfaces and applying two coats of oil bound distemper complete all as specified and directed. |
| 38 | Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper overand including a coat of primer complete all as specified and directed. |
| 39 | Preparation of old decorated ceiling surfaces and applying two coats of oil bound distemper complete all as specified and directed. |
| 40 | Applying Two or more coats on new plastered surfaces of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paintof required shade (Company Depot Tinted) with silicon additives @ 1.43 liter/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 41 | Demolition of reinforced cement concrete in roofs, floors, beams, staircases, landing, chajjas and similar suspended work, complete all as specified and directed. |
| 42 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed. |
| 43 | 50mm thick average thickenss PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding, roof kerbs rounded or chamfered on edges including using water proofing compound complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 44 | Providing water proofing treatment to sunken floor/ slab :-(a) Making fillet of size as per site requirement at corner of slab and wall with polymer modified cementitious (PMC) mortar consisting of one part of TAPECRETE P-151, two parts of cement and 6 parts of fine sand by weight.(b) Sealing of joints of pipe with Epoxy putty CICI-POXY LC of Epoxy mortar CICO-POXY 2125.(c) Cleaning the concrete surface by brushing and watering and applying a coat of TAPECRETE P-151 Acrylic polymer modified cementitious slurry consisting of one part of TAPECRETE P-151 and two parts of cement by weight. The coating shall be carried out upto 300mm above FFL and shall be allowed to dry 4-6 hours.(d) Applying a coat of TAPECRETE brush topping 1.5mm thick consisting of one part of TAPECRETE P-151, two parts of cement and two parts of silica sand be weight and cured for 2 days.(e) Applying 15mm thick plaster in CM 1:4 mixed with CICO super @ 100ml per Kg on treated surface |
| 45 | Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed brick aggregate as in sunken filling and mass concrete complete all as specified & directed. |
| 46 | 100mm thick plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in sub base complete all as specified & directed. |
| 47 | 75mm thick plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in sub base complete all as specified & directed. |
| 48 | Taking up ordown PVC/GI tubingwith all fittings,connections 15mm bore, complete all as specified and directed. |
| 49 | Taking up ordown PVC/GI tubingwith all fittings, connections 20mm bore, complete all as specified and directed. |
| 50 | 15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors ,complete all as specified and directed. |
| 51 | 20 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 52 | 25 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed. |
| 53 | Cuttingchases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc and cutting chases for concealed water tubing & making good, cutting not exc 10 cm girth, in brick walls complete all as specified and directed. |
| 54 | Vitreous China Wash down water closet (pedestal pattern) , white, (excluding, flushing cistern and flush pipe) with and including,PVC seat cover , fixed as in repair complete all as specified and directed. |
| 55 | Vitreous China Wash down water closet (pedestal pattern) , white, (excluding, flushing cistern and flush pipe) with and including,PVC seat cover ,complete all as specified and directed. |
| 56 | PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia PVC long bend for squat pattern WC , set with concrete and making good to floor, as in repair complete all as specified & directed. |
| 57 | PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia PVC long bend for squat pattern WC , set with concrete and making good to floor, complete all as specified & directed. |
| 58 | Vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests including \"P\" or \"S\" trap, flush pipe(excluding flushing cistern ) including connection to trap and flushing pipe, set with cement concrete, fixed as in repair, complete all as specified & directed. |
| 59 | Toilet paper holder of vitreous china fixed to walls with chromium plated screws, fixed as in repair, complete all as specified & directed. |
| 60 | Toilet paper holder, stainless steel, chromium platedfixed to wall with CP brass screws, complete all as specified and directed. |
| 61 | Bib taps brass, fancy type, long body with wall flange, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 62 | Bib taps brass, fancy type, long body with wall flange, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe,complete all as specified and directed. |
| 63 | Two way Bib tap brass, fancy type, (incl fixing arrangement of health faucet) long body with wall flange, standard chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repairs complete all as specified and directed. |
| 64 | Vitreous China Urinal, half stall type, white,including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screwscomplete all as specified and directed. |
| 65 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. |
| 66 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, complete all as specified and directed. |
| 67 | PVC connections 15 mm size with PTMT nuts of length 450 mm , fixed as in repair complete all as specified and directed. |
| 68 | PVC connections 15 mm size with PTMT nuts of length 450 mm ,complete all as specified and directed. |
| 69 | Wash hand basin, vitreous china, flat back, white of size 550 x 400 mm withstainless steel waste coupling, angle brackets,450mm long PVC waste pipe, fixed as in repair complete all as specified and directed. |
| 70 | Wash hand basin, vitreous china, flat back, white of size 600 x 480mm withstainless steel waste coupling, angle brackets,450mm long PVC waste pipe,complete all as specified and directed. |
| 71 | 15mm bore pillar tap, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, fancy type, fixed as in repair complete all as specified and directed. |
| 72 | 15mm bore pillar tap, fancy type,cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, fancy type complete all as specified and directed. |
| 73 | Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both ends for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 74 | Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down,screwed both and for iron pipe or for union, suitable for 15mm bore pipe,complete all as specified and directed. |
| 75 | Stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed. |
| 76 | Stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 20mm bore pipe, complete all as specified and directed. |
| 77 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with CP bracket guard and railing 60cm long,fixed as in repair complete all as specified and directed. |
| 78 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with CP bracket guard and railing 60cm long,complete all as specified and directed. |
| 79 | Chromium plated, fancy type shower rose with swivel joints 125mm dia with arm and fixing to steel pipe 15mm bore, fixed as in repair,complete all as specified and directed |
| 80 | Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all as specified and directed. |
| 81 | Towel rail 600mm long ofmild steel, chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats, fixed as in repair complete all as specified and directed. |
| 82 | Towel ring ofmild steel, stainless steel fixed with and including chromium plated brass screws and wooden / plastic cleats, fixed as in repair complete all as specified and directed. |
| 83 | Towel ring ofmild steel, stainless steel fixed with and including chromium plated brass screws and wooden / plastic cleats,complete all as specified and directed. |
| 84 | Looking mirror of size 600mmx450mm of selected quality mounted on PVC frame and back fixed to wall with screw and rawl plugs, fixed as in repairs, complete all as specified and directed. |
| 85 | Looking mirror of size 600mmx450mm of selected quality mounted on PVC frame and back fixed to wall with screw and rawl plugs, complete all as specified and directed. |
| 86 | PVC (SWR) nahani traps 75mm dia with gratingincluding jointing to wastepipe setting/fixedin cement concrete type B-1 1:2:4 fixedas in repair complete all as specified and directed. |
| 87 | PVC (SWR) floor trap 75mm bore, plain with grating including jointing with solvent cement, complete all as specified and directed. |
| 88 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 89 | PVC(SWR) rain water pipe, 75mm bore, single socketed in any length of pressure rating 6 kgf/cm2 with rubber ring joints,laid in floors,trenches, complete all as specified and directed. |
| 90 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length of pressure rating 6 kgf/cm2 with rubber ring joints,laid in floors,trenches, complete all as specified and directed. |
| 91 | PVC(SWR) rain water pipe, 75mm bore, single socketed in any length of pressure rating 6 kgf/cm2 with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc, complete all as specified and directed. |
| 92 | PVC(SWR) rain water pipe, 110mm bore, single socketed in any length of pressure rating 6 kgf/cm2 with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc, complete all as specified and directed. Note of serial item No 89, 90, 91 & 92 :-(i) Joint of pipe with RCC slab(in case of floor trap /\"P\" trap shall be water sealed with crack repair component of Dr Fixit or equivalent |
| 93 | PVC (SWR) bend 110mm bore any radius, of pressure rating 6 kgf/cm2, fixed as in repair complete all as specified and directed |
| 94 | PVC (SWR) bend 75mm bore any radius, of pressure rating 6 kgf/cm2, fixed as in repair complete all as specified and directed |
| 95 | PVC (SWR) bend 75mm bore any radius, of pressure rating 6 kgf/cm2, with access door fixed as in repair complete all as specified and directed |
| 96 | PVC (SWR) bend 110mm bore any radius, of pressure rating 6 kgf/cm2, complete all as specified and directed |
| 97 | PVC (SWR) bend 75mm bore any radius, of pressure rating 6 kgf/cm2,complete all as specified and directed |
| 98 | PVC (SWR) bend 110mm bore any radius, of pressure rating 6 kgf/cm2, with acess door fixed as in repair complete all as specified and directed |
| 99 | PVC (SWR) branch piece, 110mmbore single (single Y) equal or unequal with access door of pressure rating 6 kgf/cm2, fixed as in repair complete all as specified and directed |
| 100 | PVC (SWR) branch piece, 75mmbore single (single Y) equal or unequal with access door of pressure rating 6 kgf/cm2, fixed as in repair complete all as specified and directed |
| 101 | PVC (SWR) junction single, (Single T) equal or unequal 110mm dia of pressure rating 6 kgf/cm2, with access door fixed as in repair complete all as specified and directed |
| 102 | PVC (SWR) junction single, (Single T) equal or unequal 75mm dia of pressure rating 6 kgf/cm2, with access door fixed as in repair complete all as specified and directed |
| 103 | PVC (SWR) junction single, (Single T) equal or unequal 110mm dia of pressure rating 6 kgf/cm2,complete all as specified and directed |
| 104 | PVC (SWR) junction single, (Single T) equal or unequal 75mm dia of pressure rating 6 kgf/cm2, with access door complete all as specified and directed |
| 105 | PVC (SWR) junction single, (Single T) equal or unequal 110mm dia of pressure rating 6 kgf/cm2, with access doorcomplete all as specified and directed |
| 106 | PVC (SWR) junction single, (double Y) equal or unequal 110mm dia of pressure rating 6 kgf/cm2, with access door fixed as in repair complete all as specified and directed |
| 107 | PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cementfixed as in repairs, complete all as specified and directed. |
| 108 | PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement, complete all as specified and directed. |
| 109 | 110mm bore PVC (SWR) vent cowl any radius complete all as specified and directed. |
| 110 | 75mm thick plain cement concrete type C-1 1:3:6 (Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed.Note : 10mm construction joint will be provided and panel should not be more than 3metre in length and joint filled with filler bitumen and sand in ratio (1:3) |
| 111 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) triple layered, screwable lid, hoisted and fixed in position, including tank nipple, union, PTMT ball valve 20mm bore etc, fixed as in reapircomplete all as specified and directed. |
| 112 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) triple layered, screwable lid, hoisted and fixed in position, including tank nipple, union, PTMT ball valve 20mm bore etc,complete all as specified and directed. |
| 113 | Demolition and breaking up drain pipes of any type and description internal dia of pipe 150mm, set in cement mortar including PCC packing in bed and hunching complete,all as specified and directed. Note:Excavation and earth work shall be measured and paid separately. |
| 114 | Plain cement concrete type D-2, 1:4:8 using 40mm graded crushed stone aggregate as in bed to drain pipes including cradle of 150mm bore pipe after the pipes are laid and tested , complete all as specified and directed. |
| 115 | HDPE double wall corrugated (DWC) pipes (ISI Marked) 150mm SN-8 class as per IS 16098 Part -II for non pressure underground drainage and sewage applications with speials including cost of special \"O\" rubber rings couplers etc, laid in trenches on concred bed to level / gradient, jointing with appropriate class fittings as per manufacturer\"s instructios including jointing accessories and fittings complete all as specified and directed. |
| 116 | Reinforced concrete pipes, 150 mm boreclass NP2, laid in trench and jointed completewith collars , jointed with cement mortarinculding fitting of same grade complete all as specified and directed. |
| 117 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. |
| 118 | Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 119 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished,and reforming benching as required,internal dia of pipe 150mm all as specified and directed. |
| 120 | Pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in manhole cover slabs etc set in cement mortar 1:4,complete all as specified and directed. |
| 121 | PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in surface channels, benching and drains complete all as specified and directed. |
| 122 | Demolition of brick work built in cement mortar including all quoins, arches, pillar etc including disposal of rubbish n.exc 1.5 Km complete all as specified and directed. |
| 123 | Brick work with sub class ‘B’ bricksstraight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 124 | Brick work with sub class ‘B’ bricksstraight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 125 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 126 | Plain cement concrete type B-0 (1:2:4) using 12.5mm graded crushed stone aggregate as inlintel upto 1.5m clear span, cills, steps, seismicand other similar bands, shelves, copings, bed plates, hold fast, plinth courses and the like finished fair & even, including necessary formwork complete all as specified. |
| 127 | Precast factory made RCC manhole covers of size 450 mm x 450 mm x 75mm, as in cover slab of gully trap including MS frame, set in position in cement mortar 1: 4complete all as specified and directed. |
| 128 | Factory made RCC M-35 pre cast man hole covers(Medium duty), of size 600mm x 1200mm x 100mm with plain faces, includingMS ring, MS frame, set in position in cement mortar 1:4, complete all as specified and directed. |
| 129 | Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge |
| 130 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws as specifiedcomplete all as specified & directed by Engineer-in-charge. |
| 131 | Excavation in post holes (or similar hole) each in hard & dense soil n.exc 0.50 cu m getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, complete all as specified and directed. |
| 132 | Excavating in trenches, in any type soil n.exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out, including getting out the excavated soil and disposal of surplus exavated soilcomplete all as specified and directed.NOTE : Returning filling shall be measured and paid separately |
| 133 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soil, complete all as specified and directed. |
| 134 | providing cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed |
| 135 | providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed |
| 136 | Machine pressed Concrete interlocking paver block, with grey cement andpigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Gradecomplete all as specified and directed |
| 137 | Sand filling under floors or in foundations including watering and consolidation , all as specified. |
| 138 | PCC 1:2:4 type B-1 (20 mm graded stone aggs) as in kerb stones,, mud stops, roof kerb etcrounded or chamfered on edgescomplete all as specified and directed. |
| 139 | Applying self adhesive waterproof texture paint with 100% acrylic latex resin (locally known as sand dune paint) over and including wall care putty as per manufacturer\"s instructions to walls/ ceiling/ chajjas/ roof projections in patches including complete removal of existing paint complete all as specified and directed. |
| 140 | Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed |
| 141 | Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 142 | Material and labour for reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 143 | Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 144 | Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 145 | Reinforced cement concrete type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 146 | Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed. |
| 147 | Form work to sides of pillars, coloumns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed. |
| 148 | Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. |
| 149 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) curved/ flat, rough finished surfaces of concrete complete all as specified and directed. |
| 150 | Form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc10cm but n.exc 20cm wide complete all as specified and directed. |
| 151 | Form Work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5cm but n.exc 10cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc10cm but n.exc 20cm wide complete all as specified and directed. |
| 152 | TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed. |
| 153 | TMT bars 8mm dia and over upto and including 10mm dia in stirrups, spacers and binding , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. |
| 154 | Earth filling under floor including watering and consolidation in layers n.exc 25cm thick (Earth shall be obtained from excavation free for vegetation, pebbles, foreigh materials etc) complete all as specified & directed. |
| 155 | Hard core of gauge of broken stone or boulders, exc 63mm but n.exc 100mm, deposited, spread and lavelled in layers n.exc 15 cm thick, watered & rammed to a true surface ,complete all as specified and directed. |
| 156 | Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all asspecified & directed. |
| 157 | Factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design ,solid PVC foam with homogenous fine cellular structure density 750 having smooth outer integral skin,supplying & fixing in frame at site complete all as specified and directed. |
| 158 | Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,including filling of PCC 1:3:6 in hollow frame complete all as specified and directed. |
| 159 | 30mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides all as specified & directed by Engineer-in-charge. |
| 160 | 35 mm thick second class hard wood glazed and skelton shutters open rebated and prepared to received gauge/ glass etc, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc complete all as specified and directed. |
| 161 | Preparing surfaces of steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint treating small articles such as stop, covers, gully gratings, hold fast, ends of posts, baks of chowkhats etc, area n.exc 0.1 sqm each complete all as specified and directed. |
| 162 | 20mm thick rendering in Cement and Sand mortar 1:4 over roof slab and sunken portion finished even and fair mixed with water proofing compound, including dimantling of the existing roof slab / suken portion complete all as specified. (NOTE : WPC will be measrued and paid separately) |
| 163 | Cleaning the roof surface, terracing including flushing and junction of parapets etc and applying 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil bound bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/sqm on top of membrane, complete all as specified & directed. |
| 164 | Removal of excavated material to distance not exc 200 metre but n.exc 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 165 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 166 | Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account.Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 167 | All as per serial item 166 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 168 | All as per serial item 166 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed |
| 169 | All as per serial item 166 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 170 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. |
| 171 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. |
| 172 | Socket outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 173 | Socket outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 174 | Modular white cover plate with frame, suitable for 2 modulecomplete all as specified and directed. |
| 175 | Modular white cover plate with frame, suitable for 3 modulecomplete all as specified and directed. |
| 176 | Modular white cover plate with frame, suitable for 6 modulecomplete all as specified and directed. |
| 177 | Modular white cover plate with frame, suitable for 8 modulecomplete all as specified and directed. |
| 178 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. |
| 179 | Stepped type electronic fan regulator flush type complete all as specfied and directed. |
| 180 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 181 | LED Bulb 12 watt self ballasted Retrofit type lamp with PBT body shell and DC diffuser CCT 6500 K complete all as specified and directed. |
| 182 | Slim LED lights fitting, 4 feet,1x 20W, inverter rechargeable,inbuilt lithium ion battery with chargingtime 8 to 10 hrs & back upt time minimum 8 hrs, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed. |
| 183 | Slim LED lights fitting, 4 feet,1x 20W, inverter rechargeable,inbuilt lithium ion battery with chargingtime 8 to 10 hrs & back upt time minimum 8 hrs, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 184 | Slim LED lights fitting, inverter type LED2 feet,1x 10W,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 185 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including taking down old street light complete all as specified and directed. |
| 186 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,complete all as specified and directed. |
| 187 | LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,complete all as specified and directed. |
| 188 | LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, fixed as in repair complete all as specified and directed. |
| 189 | LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size,complete all as specified and directed. |
| 190 | Taking down carefully old unserviceable ceiling fan/wall fan/exhaust fan complete removing its blade and deposit to the MES store yard complete all as specified and directed. |
| 191 | Exhaust fan, steel body AC single Phase. 230V of size 450mm sweep , 1400 rpm, heavy duty with, blades, and frame and louvers including grouting nuts, fastners and provision of flexible coper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. |
| 192 | Taking down carefully old unserviceable Geyser of any capacity complete removingand deposit to the MES store yard complete all as specified and directed. |
| 193 | Electric water heater(vertical type geyser), capacity 50 litre, 2 KW BEE 5 Star rated AC single phase, including MS glass lined inner tank, glass coated heating element, high density PUF insulation, Anode rod protection, heavy duty fastner not less than 100mm with suitable size of nut & washer grouted in wall with complete mason work for proper mounting of geyser fastner bolts with all accessories such as safety valve, thermostat, NRV, connection piece etc. making necessary inlet / outlet water connection, testing on load complete all as specified and directed. |
| 194 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 195 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 196 | Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.NOTE FOR SERIAL ITEM NO 195 & 196:(i)Two runs of cable, one run of earth wireshall be considered as one running metre(ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 197 | Disconnecting the power supplyand taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB\"s ,MCB\"s etcand removing from site, Complete all as specified and directed . |
| 198 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240V completed all as specified and directed. |
| 199 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting,12 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 200 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting,8 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 201 | MCB, SPN , 240 volt,40 to 63Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 202 | MCB, SPN , 240 volt,32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 203 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , \"C\" series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 204 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 andpresast RCC1:2:4 type B-1 pit cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8mm dia bar, watering pipe of 20mm dia GI light grade and 15mm dia light grade for earth lead protection and testing, including dismantling of old earthing completionall as specified and directed. |
| 205 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mmburried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 andpresast RCC1:2:4 type B-1 pit cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8mm dia bar, watering pipe of 20mm dia GI light grade and 15mm dia light grade for earth lead protection and testing on completionall as specified and directed. |
| 206 | Chemical earthling with Copper strips as per details specified below :-(a) The earth pit shall be of size 1.2m x 1.2m and depth 3.6(minimum)(b) Copper plate 900mm x 600mm x 5mm(c) Copper strip 50mm x 6mm (Cross section)(d) Chemical ofquantity (i) Charcoal -250 Kg, salt crystal 200 Kg, Magnesium sulphate - 100 Kg(e) 25mm dia GI pipe medium grade above copper plate filled with funnel wire alongwith cap.(f) Copper strip shall be provided with GI protection pipe of 50mm light grade up to test point.NOTE :-(i)Test result of earth resistance of chemical earth pits shall be less than 1 Ohm.(ii) Alternate layers of charcoal and salt, five layer each up to top of copper plate after which a 2 inch layer of magnesium sulphate to be laid at top and balance volume to be filled with soft soil.(iii)The chemical salt and magnesium suphate shall never be mixed but are to be laid in layers only.(iv) Tenders quoted rate is deemed to include the cost of excavation and earth works, removal of surplus soil to a distance not exc 50m construction ofPCC pit in (1:3:6) type C2 cement concrete using 20mm graded stone aggregates RCC (1:2:4) type B-1 pit cover with MS handle testing complete all as specified and directed. |
| 207 | Test point terminal block made of gun metal or phosphorus bronze ofsize 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw compelte all as specified and directed. |
| 208 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size copper strip 20x 3mm compelte all as specified and directed. |
| 209 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including connecting with two core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 210 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm including cutting openings, through brick walls in round shape , for 300mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge. |
| 211 | Venti Air exhaust fan strong air suction, rust proof body classic type and dust protection shutters 200mm sweep, voltage 230V, 50 Hz, RPM 2100, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including cutting openings, through brick walls in round shape , for 300mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge. |
| 212 | 32mm dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed |
| 213 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail