| 1 | Repair, maint and making the continuity of cooling effect of Split AC / Window AC / cassette AC / Tower AC complete by replacement of defective parts such as PCB, compressor, condenser, capacitor, fan blade, fan motor, Refrigerant topping up, water leakage, leak test, blower motor, blower us, cleaning of indoor and outdoor unit, electric wiring, control wiring, inverter PCB, thermostate, no supply and other similar AC spare parts etc. complete all as specified and directed by Engineer-in-Charge Note :- (i) Any accessories found unserviceable that shall be replaced under respective items of this Sch.(ii) Contractor has to provide sufficient manpower minimum 02 AC Technician and 02 helper alongwith necessary tools for repair of AC daily including sunday / holidays for resolving timely complaints and rates shall be included in the quoted rates.(ii)The replacement of defective / nonfunctional parts except compressors during repair work shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (iii)Necessary transportation arrangement for attending day to day AC complaint and taking down unserviceable ACs from user site to workshop & civil area included in the quoted rates.(iv)Recovery of Rs 500 per day will be recovered for non attending of complaint within 24 hours daily till its serviceability except leak test, compressor replacement, condenser replacement, indoor unit replacement, inverter PCB, shifting of ACs |
| 2 | Supply only following items ofAir conditioning split/windowtype AC of capacity 1.5/2/3TRof any make/model/ capacity including checking of defects and rectified. (a) Supply only in replacement with new Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC supply. Make M/s Asian / M/s Unistar / M/s Epcos / M/s Electro complete all as specified and as directed. |
| 3 | Supply only in replacement with new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply complete all as specified and as directed. |
| 4 | Supply only in replacement with new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ ACsupply complete all as specified and as directed. |
| 5 | Supply only in replacement with new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply complete all as specified and as directed. |
| 6 | Supply only in replacement with new Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC supply.complete all as specified and as directed. |
| 7 | Supply only in replacement with new Running capcitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC supply complete all as specified and as directed. |
| 8 | Supply only in replacement with new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC supply complete all as specified and as directed. |
| 9 | Supply only in replacement with new PVC braded drain pipe of size 15 mm inner dia |
| 10 | Supply only in replacement with new PVC braded drain pipe of size 20 mm inner dia |
| 11 | Supply only in replacement with new PVC braded drain pipe of size 40 mm inner dia |
| 12 | Supply only in replacement with new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unitsuitable for Split AC/Window AC1.5/2.0 TR of capacity, model and make as per existing all as directed. |
| 13 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC/window AC upto3.0 TR inverter type as per existing make and model. |
| 14 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR capacity Non inverter type, model and make as per existing all as directed. |
| 15 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR cassete type of any model and make as per existing all as directed. |
| 16 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing all as directed. |
| 17 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR complete all as specified and directed. |
| 18 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR complete all as specified and directed. |
| 19 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 3TR complete all as specified and directed. |
| 20 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type Cassete AC 3TR including complete all as specified and directed. |
| 21 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase non inverter type complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 22 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR/3 TR split AC Single Phaseinverter type complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 23 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase complete all as specified and directed at site. |
| 24 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 25 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Three Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 26 | Supply only in replacement with new capillary tube of size as per sample suitable for split AC 1.5TR/2TR/3TR and window type AC of any make complete all as specified and directed. |
| 27 | Supply only in replacement with new Liquid line copper filter as per sample suitable for 1.5/2 TR split/window AC. |
| 28 | Supply only in replacement with new Liquid line copper filter as per sample suitable 3 TR split AC. |
| 29 | Supply only in replacement with new Over load Relay as per sample suitable for any type split type 1.5/2 TR Capacity. |
| 30 | Supply only in replacement with new Over load Relay as per sample suitable for any type split type 3 TR Capacity. |
| 31 | Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeAC\"s of Capacity 1.5/2 TR. |
| 32 | Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeAC\"s of Capacity 3 TR. |
| 33 | Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split AC\"s any make as existing. |
| 34 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5 /2 TR Capacity as per existing make and model. |
| 35 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TR Capacity as per existing make and model. |
| 36 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5/2 TRcapacity inverter type as per existing make and model. |
| 37 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TRcapacity inverter type as per existing make and model. |
| 38 | Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 1.5 / 2 TR Capacity. |
| 39 | Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 3 TR Capacity. |
| 40 | Supply only in replacement with new flapper suitable for Split AC as per sample for capacity 1.5 to 3 TR |
| 41 | Supply only in replacement with new PVC Grills as per sample and for any make window AC. |
| 42 | Supply only in replacement with new Thermostate switch with knob 230 volts for Window AC |
| 43 | Supply only in replacement with new Check valve any dia for upto 3 TR capacity Split AC\"s as per sample. |
| 44 | Supply only in replacement with new Expansion valve complete set as per sample suitable for 1.5 / 2 TR Spllit AC. |
| 45 | Supply only in replacement with new Expansion valve complete set as per sample suitable for 3 TR Spllit AC. |
| 46 | Supply only in replacement with new Ventury as per sample made of thermo-coal insulationsuitable for Window AC . |
| 47 | Supply only in replacement with new Pre-air filter made up of PVC for indoor unit as per sample of split AC suitable for any capacity make and description complete |
| 48 | Supply only in replacement with new Brass service valve of 5/8\" dia with flare unit as per sample for split type AC as per existing model and shape. |
| 49 | Supply only in replacement with new Brass service valve of 3/8\" dia with flare unit as per sample for split type ACas per existing model and shape. |
| 50 | Supply only in replacement with new Brass service valve of 1/2\" dia with flare unit as per sample for split type ACas per existing model and shape. |
| 51 | Supply only in replacement with new Brass service valve of 1/4\" dia with flare unit as per sample for split type ACas per existing model and shape. |
| 52 | Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacityand reassembling, fixing and testing the dismantled AC in new position after making necessary cutting/openingand making good in window frame complete all as specified and directed.Note- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A\". |
| 53 | Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase and reassembling, fixing and testing incl installation of AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing\"s etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid seperatly under appropriate item of schedule A |
| 54 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 3/8\" bore. |
| 55 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 5/8\" bore |
| 56 | Supply and fixing in replacement with new copper tubing of special annealed pressure copperof size 1/4\" bore |
| 57 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/2\" bore |
| 58 | Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 3/8\" bore |
| 59 | Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 5/8\" bore |
| 60 | Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 1/4\" bore |
| 61 | Supply and fixing in replacement with nitrile insulation foam (closed cell elastomeric) suitable for copper pipe of size 1/2\" bore |
| 62 | Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed. |
| 63 | Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 3 TR split AC complete all as specified and directed . |
| 64 | Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per samplecomplete suitable for 1.5 TR Split Acs 230 volts of existing make, vaccumising and pressure testing is inclusive in the quoted rates. |
| 65 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed and suitable for 2 TR Split Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 66 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed and suitable for 3 TR Split AC Single Phase 230 volts of existing make. vaccumising and pressure testing is inclusive in the quoted rates. . |
| 67 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed andsuitable for 3 TR Three Phase Split Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 68 | Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per samplecomplete all as directed andsuitable for 1.5 TR Single Phase Window Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 69 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per sample complete all as directed andsuitable for 2 TR Single Phase Window Acs 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 70 | Supply and fixing in replacement with new Rotary compressor as per sample complete and suitable for 1.5 TR Split AC Single phase 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 71 | Supply and fixing in replacement with newRotary compressor as per sample complete all as directed and suitable for 2 TR Split AC Single phase 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 72 | Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed and suitable for 3 TR Split AC Single phase 230 volts of existing make.vaccumising and pressure testing is inclusive in the quoted rates. |
| 73 | Supply and fixing in replacement with newRotary compressor as per sample and suitable for 3 TR Split AC Three phase 230 volts of existing make. complete all as directed vaccumising and pressure testing is inclusive in the quoted rates. |
| 74 | Supply and fixing in replacement with newRotary compressor as per sample and suitable for 1.5/2.0 TR Inverter Split AC Single phase 230 volts of existing make and model. complete all as directed vaccumising and pressure testing is inclusive in the quoted rates. |
| 75 | Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB. |
| 76 | S & F in replacement with new Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps. |
| 77 | Supply and fixing in replacement with new 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 78 | Supply and fixing in replacement with new SPN 40 to 63 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 79 | Supply and fixing in replacement with new TPN / FP 32 Amp 415V 10KA \"B\" curve miniature circuit breaker (MCB)and current carrying capacity in the DB complete with connection testing and commissioning. |
| 80 | Supply and fixing in replacement with new power contactor single phase, 2 pole, AC 220 Volt, short circuit 5 kA RMS, AC-8a as per existing make and model complete all as specified and directed. |
| 81 | S&F in replacement of terminal plate for 8 incoming and outgoing connection alongwith suitable size copper lugs suitable for outdoor unit of split AC 1.5/2.0/3.0 TR single / three phase AC complete all as specified and directed. |
| 82 | M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed. |
| 83 | M & L for water jet / foam servicing of indoor /outdoor unit of split / window AC any capacity complete including covering with suitable size water proof cover for prevention of water leakage during servicing and necessary C-Sine or equivalent chemical for cleaning of cooling / condenser coil all as specified and directed |
| 84 | Supply of Refrigerant gas (R-22) Monochloro Difluoro Methane (CHCLF2) (Make :- Mafron-22/Refron-22/Floron 22) duly filled in factory sealed cylinder complete all as specified and directed.Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas. |
| 85 | Supply of Refrigerant gas (R-410)(Non CFC) duly filled in factory sealed cylindercomplete all as specified and directed. Make :- Mafron/Floron Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas. |
| 86 | Supply of Refrigerant gas (R-32)(Non CFC) duly filled in factory sealed cylindercomplete all as specified and directed. Make :- Mafron/Floron Note :- The cost of cylinder not to be included in unit rate quoted.The empty cylinder shall be returned back after use of gas. |
| 87 | S & F in repair Voltage Monitor three phase protection device for three phase system having protection against High, Low Voltage , Single Phasing and Reverse phase sequence as per sample |
| 88 | Repair of any type PCB of any type AC (Inverter / Non Inverter) as per Sample suitable for1.5 / 2/ 3 TR split / window / cassette / tower AC complete all as specified and directed by Engr - in - Charge. |
| 89 | Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 5.0 KVAcomplete all as specified and directed |
| 90 | Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed |
| 91 | Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed |
| 92 | S&F PVC insulated & sheathed copper round cable 1100 volts of size 4.0 sqmm 3 core incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. |
| 93 | All as per item No 92 but of Size 4.0 sqmm 4 core |
| 94 | All as per item No 92 but of Size 4.0 sqmm 5 core |
| 95 | All as per item No 92 but of Size 6.0 sqmm 3 core |
| 96 | All as per item No 92 but of Size 10 sqmm 3 core |
| 97 | Supply and fix in replacement Heavy Duty Air Conditioner Outdoor AC Stand for 1.0 to 3.0 TonShelf Bracket(Steel) complete with fixing accessories. |
| 98 | M & L for wirting SM/MES No in indoor unit of Split / Window AC/ Refrigerator / Water cooler/ Deep freezer etc any capacity with approved colour of synthetic enamel paint complete all as specified and directed. |
| 99 | M & L for replacement of outdoor MS wire mesh for protection of fan blade including fixing arrangement in existing AC complete all as specified and directed. |
| 100 | M & L for spray painting of outdoor unit of Split AC any capacity with approved colour including filling of cavity and repair of damaged portion of outdoor unit complete all as specified and directed. |
| 101 | S&F in replacement of wall mounting type AC timer havingDelay Time Facility, Auto & manual switch ,Suitable for window ,split type AC of capacity 1.5/2 TR.Operating on AC input Supply: 230VAC +/- 15 %, 50Hz. Output: 230V, 25 Amp. Separate for 2 A/Cs having Protections for Over voltage (OV): Cutoff 270 V & Cut in 260 V Under voltage (UV): Cutoff 160 V & Cut in 170 V working for 24 Hours timer in 4 to 8 hours time intervals all as specified and directed by Engineer-in-Charge. |