| 1 | CONSTRUCTION OF HIGHMAST ETC |
| 2 | EARTH WORK IN EXCAVATION BY MECHNICAL MEANS (HYDROLIC EXCAVATOR)/NATURAL MEANS OVER AREAS EXCEEDING 30.0 CM IN DEPTH 1.5 INCH WIDTH AS WELL AS 10 SQM ON PLAN ) INCLUDING GETTING OUT AND DISPOSAL OF EXCAVATED EARTH LEAD UPTO 50M AND LIFT UPTO 1.5 M AS DIRECTED BY ENGINEER -INCHARGE ALL KINDS OF SOIL AS PER SOR.....2.8.1 |
| 3 | EXTRA FOR EVERY ADDITIONAL LIFT OF 1.5 M OR PART THEROF IN EXCAVATION/BANKING EXCAVATED OR STACKED MATERIALS. AS PER SOR.....2.26.1 |
| 4 | FILLING AVAIBLE EXCAVATED EARTH EARTH (EXCLUDED ROCK) IN TREANCEH PLINTH SIDES OF FOUNDATIONS ETC. IN LAYER NOT EXCEEDING 20CM IN DEPTH. CONSOLIDATING EACH DEPOSITED LAYER BY RAMMING AND WATCHING LEAD UPTO 50M AND LIFT UP TO 1.5M AS PER SOR.....2.25 |
| 5 | STONE WORK R.C.R. (1 : 4) FOUNDATION AND SUPERSTRUCTURE |
| 6 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING ALL WORK UPTO PLINTH LEVEL 1:4:8 1 CEMENT 4 COARSE SAND (ZONE- III) DERIVED FROM NATURAL SOURCES A GRADED STONE AGGRIGATE 40MM NOMINAL SIZE AS PER SOR....4.1 |
| 7 | REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS ROOFS HAVING SLOPE UPTO 15\" LANDINGS BALCOINES SHELVES, AND SPIRAL STAIR CASES ABOVE PLINTH LEVEL UPTO FLOOR FIVE LEVEL, EXCLUDING THE COST OF CONTERING SHUTTERING FINISHING AND REINFORCEMENT WITH 1:1:5:3 CEMENT 1.5 COARSE SAND (ZONE-III) DERIVED FROM NATURAL SOUCES 3 GRADDED STONE AGGRIGATE 20MM NOMINAL SIZE DERIVED FROM NATURAL SOURCES AS PER SOR.....5.3 |
| 8 | PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING ALL WORK UPTO PLINTH LEVEL 1:1.5:3 1 CEMENT 1.5 COARSE SAND (ZONE- III) DERIVED FROM NATURAL SOURCES 3 GRADED STONE AGGRIGATE 20MM NOMINAL SIZE DREIVED FROM A NATURAL SOURCES AS PER SOR NO. 5.12 PLINTH BEAM AS PER SOR.....5.1.2 |
| 9 | REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS ROOFS HAVING SLOPE UPTO 15\" LANDINGS BALCOINES SHELVES, AND SPIRAL STAIR CASES ABOVE PLINTH LEVEL UPTO FLOOR FIVE LEVEL, EXCLUDING THE COST OF CONTERING SHUTTERING FINISHING AND REINFORCEMENT WITH 1:1:5:3 CEMENT 1.5 COARSE SAND (ZONE-III) DERIVED FROM NATURAL SOUCES 3 GRADDED STONE AGGRIGATE 20MM NOMINAL SIZE DERIVED FROM NATURAL SOURCES BEAM |
| 10 | PROVIDING CORRUGATED G.S. SHEET ROOFING INCLUDING VERTICAL/COVERED SURFACE FIXED WITH POLYMER CONTROL J OR I.G.I. INPUT WASHER OR WITH G.I. INPUT WASHER FIELD WITH WHITE LEAD INCLUDING A COAT OF APRROVED STEEL PRIMER TWO COAT OF APPROVED PAINT ON OVERLAPING OF SHEET COMPLETE (UPTO ANY PATCH IN HORIZONTAL VERTICAL OR CURVED) SURFACESA) EXCLUDING THE COST OF PURLINS REFER AS TREASES AND INCLUDING INTHE SIZE AND SHAPE WHEREAS REQUIRED AS PER SOR.....5.3 |
| 11 | STRUCTURAL STEEL WORK RIVETED BOLTED OR WHEELED IN BUILT UP SECTIONS TRUSES AND FRAMED WORK INCLUDING CUTTING HOISTING FIXING IN POSITION AND APPLYING A PRIMING COAT OF APPROVED STEEL PRIMER ALL COMPLETE. |
| 12 | BRICK WORK WITH COMMON BRUNT CLAY F.PS. (NON MODULAR) BRICK OF CLASS DESIGNATION 7.5 IN SUPERSTRUCTURE ABOVE PLINTH LEVEL UPTO FLOOR V LEVEL IN ALL SHAPE AND SIZE IN CEMENT MORTAR 1:6 (1 CEMENT : 6 COARSE SAND ) |
| 13 | STEEL REINFORCED FOR R.C.C. WORK INCLUDING SHUTERING CUTTING BENDING PLACING IN POSITION AND BINDING ALL COMPLETE UPTO PLINTH LEVEL . THERMO MECHANICALLY TREATED BARS GRADE FE 500D OR MORE |
| 14 | CENTERING AND SHUTTERING INCLUDING STRUTTING PROPPING ETC AND REMOVAL OF FROM FOR - FOUNDATION FOOTINGS BASE OF COLUMNS ETC FRO MASS CONCRETE |
| 15 | FOUNDATION FOOTINGS BASE OF COLOUMN ETC. FOR MASS CONCRETE |
| 16 | COLUMN PILLERS PIERS ABUTMENTS POST AND STRUTS. |
| 17 | PROVIDNG SAL WOOD WORK IN FRAME OF DOORS WINDOW CLERESTORY WINDOW AND OTHER FRAME WROUGHT FRAMED AND FIXED IN POSITION WITH HOLD FAST LUGS OR WITH DASH FASTNER OF REQUIRED DIA AND LENGTH (HOLD FAST LUGS OR WITH DASH FASTNER SHALL BE PAID SEPERATELY) |
| 18 | LINTELS BEAMS, PLINTH BEAMS, GIRDER BRESSUMERS AND CANTILEVELS WITH WATER PROOF PLY 12MM THICK |
| 19 | CEMENT CONCRETE FLOORING 1:2:4 (1 CEMNET: 2 COARSE SAND :4 GRADDED STONE AGGRIGATE) FINISHED WITH A FLOATING COAT OF NEAT CEMENT INCLUDING FIXING CEMENT SHURY BUT EXCLUDING THE COST OF NOISING OF STEP ETC COMPLETE. 25MM WOODEN PLANKING TOUGUED AND GROOVED IN FLOORING INCLUDING FIXING WITH IRON SCREWS COMPLETE WITH SECOND CLASS TEAK WOOD |
| 20 | FINISHING WITH 12MM CEMENT PLASTER 1:3 (1 CEMENT : 3 COARSE SAND0 FINISHED WITH A FLOATING COAT OF NEAT CEMENT |
| 21 | FINISHING WITH 15MM CEMENT PLASTER 1:3 (1 CEMENT : 3 COARSE SAND0 FINISHED WITH A FLOATING COAT OF NEAT CEMENT ON THE ROUGH SIDE OR HALF BRICK WALL |
| 22 | PAINTING AND DISTERMPERING WITH Ist QUALITY ACRYLIE DISTERMPER (REALY MIXED) HAVING VOC CONTENT LESS THAN 50GMS/LTR OF APPROVED MANUFACTURE OF REQUIRED SHADE AND COLOUR COMPLETE AS PER MANUFACTURE SPECIFICATION TWO OR MORE COAT ON NEW WORK |
| 23 | EXTERIOR WALL 100% PRIMIUM ACRYLIE EMULSION PAINT LAYING VOC LESS THAN 50GMS/LTR AND UV REISTANCE DIRT RESISTANCE EXTERIOR PAINT OF REQUIRED SHADE WITH SILICON ADDITIVES TWO RO MORE COAT APPLIED @1.43 LTR/10GMS |
| 24 | PROVIDNG AND LAYING FILTER MATERIALS UNDER EARTH PITCHING AS PER DRAWING AND TECHNICAL SPECIFICATION |
| 25 | 25CM THICK CEMENT CONCRETE CONSISTING OF ONE PART CEMNT 1.5 PARTS APPROVED COARSE SAND AND 3 PART OF APPROVED 13MM GRADED STONE GRITE AND INCLUDING WATER PROFFING MATERIALS. |
| 26 | SUPPLY AND FIXING OF FOLLOWING SIZE OF STEEL CONDUIT ALONG WITH ACCESSORIES IN SURFACE/RECUS PAINTING IN A CASE OF SURFACE SONDUIT OR CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED 20MM DIA 2MM THICK |
| 27 | SUPPLY AND FIXING OF FOLLOWING SIZE OF STEEL CONDUIT ALONG WITH ACCESSORIES IN SURFACE/RECUS PAINTING IN A CASE OF SURFACE SONDUIT OR CUTTING THE WALL AND MAKING GOOD THE SAME IN CASE OF RECESSED CONDUIT AS REQUIRED 25MM DIA 2.5MM THICK |
| 28 | SUPPLY AND FIXING OF METAL BOX OF FOLLOWING SIZE (NOMINAL SIZE) ON SURFACE OR IN RECES WITH SUITABLE SIZE OF PHENOLIC LAMINATED SHEET COVER IN FRONT INCLUDING PAINTING ETC AS REQUIRED 200MM X 150MM X 75MM |
| 29 | SUPPLY AND FIXING OF METAL BOX OF FOLLOWING SIZE (NOMINAL SIZE) ON SURFACE OR IN RECES WITH SUITABLE SIZE OF PHENOLIC LAMINATED SHEET COVER IN FRONT INCLUDING PAINTING ETC AS REQUIRED 150MM X 75MM X 60MM |
| 30 | SUPPLY AND FIXING OF FOLLOWING MODULAR SWITCH /SOCKET ON THE EXISTING MODULAR PLATE ETC AS REQUIRED. 2 WAY 5/6 A SWITCH |
| 31 | SUPPLY AND FIXING OF FOLLOWING MODULAR SWITCH /SOCKET ON THE EXISTING MODULAR PLATE ETC AS REQUIRED. 3PIN 5/6 A SOCKET OUTLET |
| 32 | SUPPLY AND FIXING OF FOLLOWING MODULAR SWITCH /SOCKET ON THE EXISTING MODULAR PLATE ETC AS REQUIRED. 6PIN 15/6 A SOCKET OUTLET |
| 33 | SUPPLY AND FIXING OF TWO MODULE STEPPED TYPE OF ELECTRONIC FAN REGULATER ON THE EXISTING MODULAR PLATE ETC AS REQUIRED |
| 34 | SUPPLY AND FIXING OF MODULAR BLANKING PLATE ON THE EXISTING MODULAR PLATE AND SWITCH BOX EXCLUDING MODULAR PLATE AS REQUIRED |
| 35 | SUPPLY AND FIXING OF FOLLOWING SIZE/MODULES GI BOX ALONT WITH MODULAR BASE AND COVER PLATE FOR MDDULAR SWITCHES IN RECESS ETC. AS REQUIRED 6 MODULE (200MM X 75MM) |
| 36 | SUPPLY AND FIXING OF FOLLOWING SIZE/MODULES GI BOX ALONT WITH MODULAR BASE AND COVER PLATE FOR MDDULAR SWITCHES IN RECESS ETC. AS REQUIRED 4 MODULE (125MM X 75MM) |
| 37 | SUPPLYING CAPACITOR TYPE CEILDING FAN COMPLETE WITH DOWN ROADS BLADES SHACKLE CANOPIES ETC FOR OPERATION ON 230V 50 CYCLES, SINGLE PHASE AC SUPPLY CONFIRMING TO ISS 374-1979 AND WITH LATEST AMENDMENT 2 YEAR MANUFACTURE WARANTY 48\" SWEEP (1200MM) REGULAR MODEL |
| 38 | LED MODULAR DOWN LIGHT 2\" X 2\" /1\" X 4\" 42-55 W |
| 39 | WIRING FOR LIGHT POINT/FAN POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE IN SURFACE /RECESES STEEL CONDUIT WITH MODULAR SWITCH MODULAR PLATE SUITABLE GI BOX AND EARTHING THE POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE ETC AS REQUIRED. GROUP A |
| 40 | WIRING FOR LIGHT POINT/FAN POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE IN SURFACE /RECESES STEEL CONDUIT WITH MODULAR SWITCH MODULAR PLATE SUITABLE GI BOX AND EARTHING THE POINT WITH 1.5 SQ. MM FRLS PVC INSULATED COPPER CONDUCTOR SINGLE CORE CABLE ETC AS REQUIRED. GROUP B |
| 41 | 2.5 MM COPPER WIRE POLY / HAVELLS |
| 42 | 4 MM COPPER WIRE POLY / HAVELLS |
| 43 | SUPPLYING AND INSTALATION OF RESIDUAL CURENT CIRCUIT BREAKER (RCCB) 63AMP 2 POLE SENSITIVITY 100MM 415 VOLT AC COMPLETE WITH ALL ACCESSORIES SUTABLE TO FIX ON A DIN-BAR ETC AS REQUIRED |
| 44 | SUPPLY AND FIXING OF HOLONIX SOLAR STREET LIGHT 60 WATT |
| 45 | 1 % Consultancy Charge 1.0 Please Enable Macros to View BoQ information |